Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Ophthalmol ; 34(2): NP118-NP120, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37491821

ABSTRACT

AIM: To report silicone oil tamponade induced vasculitis in the early post operative period - a rare manifestation of 'Toxic Posterior Segment Syndrome' after pars plana vitrectomy for rhegmatogenous retinal detachment. CASE DESCRIPTION: A 50-year-old gentleman presented with vasculitis after a pars plana vitrectomy with silicone oil tamponade on the first post-operative day. He was started on oral steroids (1 mg/ kg) tapered sequentially every week. All signs of vasculitis resolved over a period of one month after which the silicone oil was removed. The patient maintained a visual acuity of 20/90 even after 3 months. There was no recurrence of vasculitis observed thereafter. CONCLUSION: Silicone oil induced vasculitis is a rarely described entity, especially as a manifestation of toxic posterior segment syndrome. This differential must be kept in mind even on the first post-operative day in cases where silicone oil has been used for tamponade.


Subject(s)
Retinal Detachment , Vasculitis , Male , Humans , Middle Aged , Silicone Oils/adverse effects , Retinal Detachment/chemically induced , Retinal Detachment/diagnosis , Vitrectomy , Visual Acuity , Vasculitis/surgery , Retrospective Studies
2.
Eur J Ophthalmol ; 34(1): NP41-NP43, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37345304

ABSTRACT

INTRODUCTION: Tuberculosis can involve any organ in the body including ocular tissue of which the uveal tissue is most commonly infected. Choroidal involvement ranges from choroidal tubercles to granulomas. This is one of the few cases of a solitary choroidal granuloma with no other systemic symptoms in an immunocompetent child. METHOD: A case report. RESULTS: A 12-year-old female, presented with diminution of vision in the left eye for a month. The anterior segment of her left eye was normal. A fundus examination revealed an isolated orangish-yellow choroidal mass, 4 DD in size, involving the posterior pole with overlying subretinal exudation. CT scan of the thorax showed large pulmonary, cervical and pancreatic lymph nodes, along with lytic lesions of the thoracic vertebrae. Excision biopsy of the cervical lymph nodes showed caseating granulomas with no e/o malignancies on histopathology. The patient was started on anti-tubercular therapy. Six months after the treatment, the lesion had reduced in size and her vision had improved. CONCLUSION: Isolated choroidal tuberculomas can be present in eyes with little associated ocular inflammation and no other symptoms of systemic tuberculosis. High suspicion, early diagnosis and rapid initiation of medication are important for the treatment of ocular and systemic tuberculosis.


Subject(s)
Choroid Diseases , Tuberculoma , Tuberculosis, Ocular , Humans , Female , Child , Tuberculosis, Ocular/diagnosis , Tuberculosis, Ocular/drug therapy , Tuberculoma/diagnostic imaging , Tuberculoma/drug therapy , Granuloma/diagnosis , Granuloma/drug therapy , Granuloma/etiology , Choroid , Choroid Diseases/diagnosis , Choroid Diseases/drug therapy , Choroid Diseases/etiology
3.
IEEE Trans Neural Syst Rehabil Eng ; 28(6): 1317-1324, 2020 06.
Article in English | MEDLINE | ID: mdl-32310776

ABSTRACT

The sit-to-stand test (STS) is a simple test of function in older people that can identify people at risk of falls. The aim of this study was to develop two novel methods of evaluating performance in the STS using a low-cost RGB camera and another an instrumented chair containing load cells in the seat of the chair to detect center of pressure movements and ground reaction forces. The two systems were compared to a Kinect and a force plate. Twenty-one younger subjects were tested when performing two 5STS movements at self-selected slow and normal speeds while 16 older fallers were tested when performing one 5STS at a self-selected pace. All methods had acceptable limits of agreement with an expert for total STS time for younger subjects and older fallers, with smaller errors observed for the chair (-0.18 ± 0.17 s) and force plate (-0.19 ± 0.79 s) than for the RGB camera (-0.30 ± 0.51 s) and the Kinect (-0.38 ± 0.50 s) for older fallers. The chair had the smallest limits of agreement compared to the expert for both younger and older participants. The new device was also able to estimate movement velocity, which could be used to estimate muscle power during the STS movement. Subsequent studies will test the device against opto-electronic systems, incorporate additional sensors, and then develop predictive equations for measures of physical function.


Subject(s)
Accidental Falls , Movement , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL
...