Article in German | MEDLINE | ID: mdl-36323292

ABSTRACT

The first part of this case report describes the surgical treatment of a unilateral mandibular fracture in the standing horse by using a fixateur type I. By the time of implant removal, the fracture had completely healed. However, during implant removal, an implant failure of 2 of the 4 implants occurred with fragments remaining in the bone. The second part of the report focuses on the development of a special surgical instrument that was designed for removal of the implant fragments. Furthermore, the surgical method allowing the entire extirpation of the fragments within a second surgery is described.According to the authors' knowledge, this is the first case report showing the use of the presented surgical technique for the treatment of a mandibular fracture in the standing horse. Additionally, this report also provides an approach for removing implant fragments from the depth of the bone which may occur in case of implant breakage as a potential complication of the described surgery.


Subject(s)
Device Removal , Mandibular Fractures , Animals , Device Removal/adverse effects , Device Removal/instrumentation , Device Removal/veterinary , Equipment Failure/veterinary , Horses , Mandibular Fractures/surgery , Mandibular Fractures/veterinary
2.
Article in English | MEDLINE | ID: mdl-32059234

ABSTRACT

OBJECTIVE: This study compares the mechanical stability and surgical usability of 2 locking plate systems (Kyon ALPS-20 and Synthes PIP-LCP system) for arthrodesis of the equine proximal interphalangeal joint (PIJ). MATERIAL AND METHODS: The experimental ex vivo study included 6 pairs of cadaver distal limbs (n = 12). All specimens were derived from Warmblood horses of various ages that were euthanized for non-orthopedic reasons. Of the 12 limbs collected, 3 left and 3 right distal limb specimens were randomly assigned to each system for implantation. Two abaxial 4.5-mm cortical screws were inserted transarticularly in all cases. Both systems were implanted according to the manufacturer's instructions with the plates placed centrally between the 2 transarticular screws. The ALPS-20 systems were implanted using Kyon B-6.4-mm monocortical locking screws in all positions. The LCP systems were implanted axially using 2 Synthes 5-mm locking screws in the proximal and distal positions, with a standard 4.5-mm cortical screw inserted in the middle position. All constructs underwent CT-scans after implantation and biomechanical testing to detect implant deformation. Uniaxial mechanical loading was applied via a servo-hydraulic test system at a test speed of 50 mm/s, up to a maximum displacement of 80 mm. The resulting load-displacement curves were used to calculate yield point, stiffness, and maximum force for each construct. The measured values were evaluated for statistical significance (p < 0.05) between the 2 plate systems via one-factor ANOVA (Tukey test). The statistical power was verified for yield force, stiffness, and maximum load. RESULTS: No statistically significant differences between the 2 preparation groups were calculated across all of the measured parameters (p > 0.05). The ALPS system implants showed no signs of deformation, either in the plates or the screws. In contrast, the LCP demonstrated visible deformation, which had already occurred at the time of implantation from the tightening of the middle screw, as well as during the subsequent testing of the implants. After biomechanical testing, deformations ranging between 3.1° and 7.0° were measured in 4 LCPs. A total implant failure was observed for 2 LCPs. CONCLUSION AND CLINICAL RELEVANCE: Both systems demonstrated comparable mechanical properties in the present study's ex vivo test model for equine PIJ arthrodesis. As such, the Kyon ALPS-20 may be a good alternative to the Synthes LCP for equine PIJ arthrodesis.


Subject(s)
Arthrodesis/veterinary , Bone Plates/veterinary , Horses/surgery , Joints/diagnostic imaging , Joints/surgery , Analysis of Variance , Animals , Arthrodesis/instrumentation , Arthrodesis/methods , Arthrodesis/standards , Biomechanical Phenomena , Bone Plates/classification , Bone Screws/veterinary , Cadaver , Normal Distribution , Tomography, X-Ray Computed/veterinary
3.
Article in German | MEDLINE | ID: mdl-30808031

ABSTRACT

A 2-year-old Arabian horse was presented with severe colic symptoms. During explorative laparotomy, a jejuno-jejunal invagination secondary to a submucosal intestinal mass was detected. The involved jejunal segment was surgically removed and an end-to-end anastomosis was created. Opening the specimen demonstrated the presence of a nodular mass on the head of the intussusceptum, measuring 10 cm in diameter, and almost completely obliterating the intestinal lumen. Additionally, a severe hyperemia of the jejunal mucosa was visible. Histological examination, which revealed a well-demarcated mass in the submucosa of the jejunum consisting of well-differentiated adipocytes, led to the diagnosis of an intramural lipoma. The small intestinal mucosa displayed mild to moderate signs of congestion. Pedunculated lipomas in the mesentery of horses causing intestinal volvulus and obstruction are a frequent cause of small-intestine strangulation in aged horses. To the authors' knowledge, intramural intestinal lipomas to date have not been described in the horse. The mare recovered without complications and was free of colic symptoms after 6 months.


Subject(s)
Horse Diseases/surgery , Jejunal Neoplasms/veterinary , Jejunum/surgery , Animals , Colic/etiology , Horse Diseases/etiology , Horses , Intussusception/etiology , Intussusception/surgery , Intussusception/veterinary , Jejunal Neoplasms/complications , Jejunal Neoplasms/surgery , Lipoma/complications , Lipoma/surgery , Lipoma/veterinary