1.
Clin Chem Lab Med ; 62(7): 1352-1361, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38205847

ABSTRACT

OBJECTIVES: Correct interpretation of thyroid function tests relies on correct reference intervals (RIs) for thyroid-stimulating hormone (TSH) and free thyroxine (FT4). ISO15189 mandates periodic verification of RIs, but laboratories struggle with cost-effective approaches. We investigated whether indirect methods (utilizing historical laboratory data) could replace the direct approach (utilizing healthy reference individuals) and compared results with manufacturer-provided RIs for TSH and FT4. METHODS: We collected historical data (2008-2022) from 13 Dutch laboratories to re-establish RIs by employing indirect methods, TMC (for TSH) and refineR (for FT4). Laboratories used common automated platforms (Roche, Abbott, Beckman or Siemens). Indirect RIs (IRIs) were determined per laboratory per year and clustered per manufacturer (>1.000.000 data points per manufacturer). Direct RIs (DRIs) were established in 125 healthy individuals per platform. RESULTS: TSH IRIs remained robust over the years for all manufacturers. FT4 IRIs proved robust for three manufacturers (Roche, Beckman and Siemens), but the IRI upper reference limit (URL) of Abbott showed a decrease of 2 pmol/L from 2015. Comparison of the IRIs and DRIs for TSH and FT4 showed close agreement using adequate age-stratification. Manufacturer-provided RIs, notably Abbott, Roche and Beckman exhibited inappropriate URLs (overall difference of 0.5-1.0 µIU/mL) for TSH. For FT4, the URLs provided by Roche, Abbott and Siemens were overestimated by 1.5-3.5 pmol/L. CONCLUSIONS: These results underscore the importance of RI verification as manufacturer-provided RIs are often incorrect and RIs may not be robust. Indirect methods offer cost-effective alternatives for laboratory-specific or platform-specific verification of RIs.


Subject(s)
Thyrotropin , Thyroxine , Humans , Thyroxine/blood , Thyroxine/analysis , Thyrotropin/blood , Thyrotropin/analysis , Thyrotropin/standards , Reference Values , Thyroid Function Tests/standards , Thyroid Function Tests/methods , Adult , Female , Male , Middle Aged , Product Labeling/standards
2.
Eur Thyroid J ; 12(6)2023 12 01.
Article in English | MEDLINE | ID: mdl-37855424

ABSTRACT

Objective: Congenital hypothyroidism (CH) is an inborn thyroid hormone (TH) deficiency mostly caused by thyroidal (primary CH) or hypothalamic/pituitary (central CH) disturbances. Most CH newborn screening (NBS) programs are thyroid-stimulating-hormone (TSH) based, thereby only detecting primary CH. The Dutch NBS is based on measuring total thyroxine (T4) from dried blood spots, aiming to detect primary and central CH at the cost of more false-positive referrals (FPRs) (positive predictive value (PPV) of 21% in 2007-2017). An artificial PPV of 26% was yielded when using a machine learning-based model on the adjusted dataset described based on the Dutch CH NBS. Recently, amino acids (AAs) and acylcarnitines (ACs) have been shown to be associated with TH concentration. We therefore aimed to investigate whether AAs and ACs measured during NBS can contribute to better performance of the CH screening in the Netherlands by using a revised machine learning-based model. Methods: Dutch NBS data between 2007 and 2017 (CH screening results, AAs and ACs) from 1079 FPRs, 515 newborns with primary (431) and central CH (84) and data from 1842 healthy controls were used. A random forest model including these data was developed. Results: The random forest model with an artificial sensitivity of 100% yielded a PPV of 48% and AUROC of 0.99. Besides T4 and TSH, tyrosine, and succinylacetone were the main parameters contributing to the model's performance. Conclusions: The PPV improved significantly (26-48%) by adding several AAs and ACs to our machine learning-based model, suggesting that adding these parameters benefits the current algorithm.


Subject(s)
Congenital Hypothyroidism , Infant, Newborn , Humans , Congenital Hypothyroidism/diagnosis , Neonatal Screening/methods , Amino Acids , Thyrotropin
3.
Clin Chim Acta ; 548: 117505, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37543354

ABSTRACT

BACKGROUND AND AIMS: Graves' Disease (GD) is an autoimmune form of hyperthyroidism where autoantibodies are directed against the TSH-receptor (TSH-receptor antibodies; TRAb). GD is suspected if TRAb concentrations are above a pre-specified cut-off value. TRAb concentrations are measured using immunoassays. This study aimed to compare the performance of the recently implemented Alinity immunoassay to the KRYPTOR and Cobas TRAb immunoassays. MATERIALS AND METHODS: Left-over serum samples in which TRAb concentrations were measured (KRYPTOR) were used. First, TRAb stability at -20 °C for four to six years and up to five freeze-thaw cycles were assessed. Second, TRAb measurements (n = 436) were repeated using the Alinity and Cobas immunoassay and results (scored as positive/negative based on cut-off value) were compared. RESULTS: TRAb results were stable over five years and up to five freeze-thaw cycles. When comparing immunoassays, 86.2% of the results were similar. Total discrepancy differed between the immunoassays (5.4% Cobas vs Alinity, 8.8% Alinity vs KRYPTOR, 13.3 % Cobas vs KRYPTOR). The KRYPTOR immunoassay showed more negative TRAb results than Cobas and Alinity. CONCLUSION: The Alinity immunoassay showed comparable TRAb results, even though slightly more positive results compared to the KRYPTORand slightly more negative results compared to the Cobas immunoassay were seen.


Subject(s)
Graves Disease , Receptors, Thyrotropin , Humans , Immunoglobulins, Thyroid-Stimulating , Immunoassay/methods , Autoantibodies , Graves Disease/diagnosis
4.
Clin Chem Lab Med ; 61(8): 1436-1445, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36877870

ABSTRACT

OBJECTIVES: Hormone measurements using automated immunoassays (IAs) can be affected by the sample matrix. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is less affected by these matrix effects. In clinical laboratories, testosterone, cortisol and, free thyroxine (FT4) are often measured using IAs. Renal failure alters serum composition in blood samples from people undergoing hemodialysis (HDp) and have, therefore, a complex serum constitution compared to healthy controls (HC). The goal of this study was to investigate the accuracy of testosterone, cortisol, and FT4 measurements in samples of HDp and to get more insight in the interfering factors. METHODS: Thirty serum samples from HDp and HC were collected to measure testosterone, cortisol, and FT4 using a well standardized isotope dilution (ID)-LC-MS/MS method and 5 commercially available automated IAs (Alinity, Atellica, Cobas, Lumipulse, UniCel DXI). Method comparisons between LC-MS/MS and IAs were performed using both HDp and HC samples. RESULTS: Average bias from the LC-MS/MS was for testosterone, cortisol, and FT4 immunoassays respectively up to 92, 7-47 and 16-27% more in HDp than in HC samples and was IA dependent. FT4 IA results were falsely decreased in HDp samples, whereas cortisol and testosterone concentrations in females were predominantly falsely increased. Correlation coefficients between LC-MS/MS and IA results were lower in HDp compared to HC samples. CONCLUSIONS: Several IAs for testosterone (in women), cortisol, and FT4 are less reliable in the altered serum matrix of samples of HDp than in HC. Medical and laboratory specialists should be aware of these pitfalls in this specific population.


Subject(s)
Hydrocortisone , Testosterone , Humans , Female , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Immunoassay/methods , Renal Dialysis
5.
Clin Chem Lab Med ; 61(9): 1605-1611, 2023 08 28.
Article in English | MEDLINE | ID: mdl-36994743

ABSTRACT

OBJECTIVES: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. METHODS: This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. RESULTS: It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. CONCLUSIONS: Our candidate cRMP measures FT4 accurately and performs well in serum matrix.


Subject(s)
Tandem Mass Spectrometry , Thyroxine , Humans , Chromatography, Liquid/methods , Reproducibility of Results , Tandem Mass Spectrometry/methods , Renal Dialysis , Isotopes , Reference Standards
6.
Front Endocrinol (Lausanne) ; 14: 1130661, 2023.
Article in English | MEDLINE | ID: mdl-36814580

ABSTRACT

Common symptoms of overt hypothyroidism are non-specific and include fatigue, lethargy, and dry skin. Although the diagnosis is considered to be straightforward, no single symptom can be used to identify patients with overt hypothyroidism, while many patients with subclinical hypothyroidism are asymptomatic. A large population-based study on the spectrum of symptoms in subclinical hypothyroidism showed similar rates of thyroid disease-related symptoms compared with euthyroid subjects, while the TSH concentration had no impact on symptom score. Together, these findings make it challenging to attribute symptoms to their underlying cause. This is also true in the case of unexplained persistent symptoms in levothyroxine-treated patients. Although generally considered a life-long replacement therapy, successful thyroid hormone discontinuation resulting in euthyroidism has been reported in approximately one third of patients. Thus, we overtreat patients with (subclinical) hypothyroidism, highlighting the importance of reliable diagnostic criteria. The diagnostic process, including the implementation of robust TSH and FT4 reference intervals, is especially challenging in specific situations including aging, pregnancy, non-thyroidal illness, and central hypothyroidism. There is a clear need for improved adherence to current guidelines from scientific societies and for willingness to manage symptoms without a clear pathological correlate, especially in the case of mild TSH elevations. This review will highlight recent literature on this topic and offers some practice points.


Subject(s)
Hypothyroidism , Thyroid Diseases , Humans , Hypothyroidism/drug therapy , Thyroid Diseases/complications , Thyroid Hormones/therapeutic use , Thyrotropin , Thyroxine/therapeutic use
7.
Endocr Connect ; 12(4)2023 Apr 01.
Article in English | MEDLINE | ID: mdl-36762702

ABSTRACT

Introduction: In our hospital, physicians noticed high free thyroxine (fT4) concentrations without complete suppression of thyroid-stimulating hormone (TSH) in blood samples of patients at the outpatient clinic, which appeared to occur more often following the introduction of a new fT4 immunoassay. This discordance may be explained by incorrect reference intervals, analytical issues, or patient-related factors. We aimed to establish the contribution of the possible factors involved. Methods: Reference intervals of both fT4 immunoassays were re-evaluated using blood samples of healthy volunteers and the new immunoassay's performance was assessed using internal quality controls and external quality rounds. The frequency of discordant fT4 and TSH pairings obtained from laboratory requests were retrospectively analysed using a Delfia (n = 3174) and Cobas cohort (n = 3408). Last, a literature search assessed whether the time of blood draw and the time of levothyroxine (L-T4) ingestion may contribute to higher fT4 concentrations in L-T4 users. Results: The original reference intervals of both fT4 immunoassays were confirmed and no evidence for analytical problems was found. The Delfia (n = 176, 5.5%) and Cobas cohorts (n = 295, 8.7%) showed comparable frequencies of discordance. Interestingly, 72-81% of the discordant results belonged to L-T4 users. Literature indicated the time of blood withdrawal of L-T4 users and, therefore, the time of L-T4 intake as possible explanations. Conclusions: High fT4 without suppressed TSH concentrations can mainly be explained by L-T4 intake. Physicians and laboratory specialists should be aware of this phenomenon to avoid questioning the assay's performance or unnecessarily adapting the L-T4 dose in patients.

9.
Eur Thyroid J ; 11(6)2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36219545

ABSTRACT

Objective: Thyroid hormone measurements are often performed in pregnant women, as hypo- and hyperthyroidism during pregnancy can severely affect the fetus. Serum free thyroxine (fT4) measurements are well known for their analytical challenges, due to low serum concentrations and the subtle equilibrium between free and bound T4 (to thyroid-binding globulin (TBG), transthyretin and albumin). Pregnant women have high TBG concentrations due to an increase in human chorionic gonadotropin (hCG) and estrogen and lower albumin concentrations which change the equilibrium and may affect the validity of fT4 measurements in their samples. As accurate serum fT4 measurements in pregnant women are important for the long-term health of the fetus, we aimed to evaluate the accuracy of several fT4 immunoassays in the serum of pregnant women. Methods: FT4 was measured in healthy controls and pregnant women using a candidate-reference method (LC-MS/MS) and five commercially available automated immunoassays (Alinity (Abbott), Atellica (Siemens), Cobas (Roche), Lumipulse (Fujirebio) and UniCel DXI (Beckman Coulter)). Method comparisons (Bland Altman plots and Passing and Bablok analyses) were performed. Results: Serum samples from both healthy controls (n = 30) and pregnant women (n = 30; mean gestational age, 24.8 weeks) were collected. The fT4 immunoassays deviated +7 to +29% more from the LC-MS/MS in serum samples of pregnant women than healthy controls (falsely high). Conclusions: Our results indicate that immunoassays overestimate fT4 in pregnant women, which might lead to an overestimation of thyroid status. Physicians and laboratory specialists should be aware of this phenomenon to avoid drawing false conclusions about thyroid function in pregnant women.

10.
J Endocrinol ; 253(2): R21-R45, 2022 03 31.
Article in English | MEDLINE | ID: mdl-35256536

ABSTRACT

Currently, thyroid hormone status is predominantly determined by the measurement of serum thyroid-stimulating hormone and free thyroxine. Although it is assumed that serum thyroid hormone (TH) concentrations within the reference range represent euthyroidism, it is unknown whether this reflects euthyroidism in all tissues (e.g. brain, muscle, bone and liver). To date, no serum marker has been established for clinical use that represents TH status within tissues accurately. However, several biomarkers have been investigated and innovative techniques have been used to unravel new biomarkers. This review provides an overview of proposed serum biomarkers that reflect tissue TH status in humans. Furthermore, we discuss the feasibility of these serum markers in clinical practice.


Subject(s)
Thyroxine , Triiodothyronine , Biomarkers , Humans , Thyroid Hormones , Thyrotropin