Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 16(3): e56954, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38665736

ABSTRACT

Glutaraldehyde (GA), a potent disinfectant and sterilizing agent extensively used in healthcare settings, has garnered attention for its association with contact dermatitis. This occupational skin condition, often induced by repeated exposure to GA, poses significant challenges to the well-being of healthcare professionals and patients alike. Understanding the causes, symptoms, and preventive measures against GA-induced contact dermatitis is essential for promoting a safe and healthy working environment in healthcare facilities. A 28-year-old female presented with a severe burning sensation and dark brown patches in the lower chin region, one day following root canal treatment. Based on the characteristic appearance of patches and the typical burning sensation associated with an allergic reaction, a diagnosis of acute contact dermatitis was made. Patch testing by an expert dermatologist confirmed that the patient was allergic to GA. GA, a popular commercial germicidal product, is widely used as a cold sterilizing agent for operative dental instruments. The patient developed a reaction as the endodontic files used during the root canal procedure were cold sterilized with 2% GA. The lesion experienced significant improvement and ultimately healed following the administration of corticosteroids and antihistamines. This report concerns a case of GA-induced contact dermatitis. As GA is being used more widely, particularly in dental clinics, this case was of interest and is reported in the safety interest of patients and clinicians.

2.
Eur J Oral Sci ; 132(2): e12971, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38235853

ABSTRACT

The current study evaluated the stress distribution in a maxillary central incisor with mid-root fracture after splinting with different intra-radicular posts using 3D-finite element analysis (FEA). Five 3D-FEA models were constructed. Model 1 was an intact tooth with no fracture, Model 2: A tooth with a horizontal mid-root fracture, with no treatment. Model 3: Same as model 2, and intraradicular splinting using fiber post. Model 4: Same as model 2 and intra-radicular splinting using Protaper Gold file F3. Model 5: Same as model 2, and with intraradicular splinting with Ribbond. The FEA of all models was done to obtain the maximum Von-Mises stress in the root canal space, the dentin, the periodontal ligament, and the bone. The highest Von Mises stresses for the root canal space and the dentin were found in Model 3, followed by models 4, 5, and 2, and least in Model 1. The Von Mises stress of the periodontal ligament was the least in model 1. The Von Mises stress of bone was higher in all experimental models than in the baseline model. The results suggest that in cases where intra-radicular splinting is indicated, fiber posts and Ribbond are better alternatives to endodontic files due to the lower stresses exerted.


Subject(s)
Polyethylenes , Post and Core Technique , Finite Element Analysis , Dentin , Incisor , Stress, Mechanical
3.
J Oral Biol Craniofac Res ; 13(4): 495-499, 2023.
Article in English | MEDLINE | ID: mdl-37293581

ABSTRACT

Aim: The aim of the study was to determine the porosity, dissolution and apical extrusion of AH Plus, MTA Fillapex and EndoSequence BC sealer after immersion in phosphate buffered saline (PBS) using microcomputed tomography (micro-CT). Methodology: Forty-eight single-rooted teeth were selected. Gutta percha and one of the aforementioned root canal sealers was used for obturation using continuous wave technique. The specimens were scanned after obturation and after seven days of immersion in PBS, by using micro-computed tomography. Porosity, sealer dissolution and apical extrusion were calculated. Statistical analysis was done by using paired t-test, post hoc tukey test and Fischer exact test. Results: Significantly higher percentage of porosity and dissolution of sealer in the apical 4 mm was found for MTA Fillapex and EndoSequence BC sealer than for AH Plus. The incidence of apical extrusion was significantly more in MTA Fillapex (56.25%), followed by EndoSequence BC (31.25%) and AH Plus (0%). Conclusions: None of the three root canal sealers exhibited perfect three-dimensional obturation. The sealers manifested porosity, dissolution and apical extrusion to varying degrees both after obturation and after storage in PBS for 7 days.

4.
J Clin Exp Dent ; 15(2): e135-e141, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36911156

ABSTRACT

Background: To evaluate bilateral symmetry and anatomical variations of root morphology of permanent mandibular second molar using systematic evaluation of CBCT scans. Material and Methods: This cross-sectional study involved the mandible which were imaged using serial axial cone-beam computed tomography (CBCT) from 680 North Indian patients who visited dental hospital for various reasons unrelated to the study. CBCT Records with presence of bilateral fully erupted permanent mandibular second molars with fully formed apexes were selected. Results: Bilaterally present two root and three canal configurations were most consistently seen (75.88 % and 59.11 %, respectively). The occurrence of two roots with two canals and four canals was 15.14% and 1.61% respectively. Mandibular second molar present with one extra root, radix entomolaris with three canals and four canals was 0.44% and 3.53% while radix paramolaris present with three canals and four canals 1.32% and 1.03% respectively. The occurrence of C-shaped root bilaterally with C shaped canal was 15.88% whereas the presence of one fused root bilaterally was 0.44%. The presence of four roots bilaterally with four canals was identified in only one CBCT scanned image (0.14%). The frequency distribution of root morphology on bilateral symmetrical analysis revealed 98.58 % bilateral symmetry. Conclusions: In 402 CBCT scans, bilateral presence of two roots with three canals was the most typical root structure seen in mandibular second molars (59.11%). A rare variation found was the presence of four roots occurring bilaterally, seen in only 1 CBCT scan. Bilateral symmetrical analysis of root morphology revealed 98.58 % bilateral symmetry. Key words:Anatomic root variations, mandibular second molar, Cone Beam Computed Tomography scans, bilateral symmetry.

5.
Cureus ; 15(1): e33256, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36741615

ABSTRACT

Background and aim The major barrier to oral health care for geriatrics is access to dental care. Teledentistry is the field of dentistry that uses telecommunication with digital imaging for the exchange of valid information for diagnosis, treatment, and continuing dental education, enabling some means of approach to oral health care. This study aimed to assess the accuracy of diagnosing dental caries in the older age group by examining intraoral photographs taken by smartphone camera compared with standard clinical dental examination. Methods and material A calibrated dentist examined 18 patients aged 60-75 for six variables: sound tooth, decayed tooth, filled tooth with and without caries, missing tooth, and the presence of prosthesis. Intraoral photographs of each patient were taken using a smartphone. The photographs were then sent to six different examiners through WhatsApp. The accuracy of the diagnosis was measured by applying Cohen's kappa, sensitivity, and specificity. Fleiss' kappa was used to measure the agreement index using the software R (R Foundation for Statistical Computing, Vienna, Austria) version 4.2.1. Results The overall agreement between the tele-examiners and the control was measured, with the kappa scores ranging from 0.897 to 0.921, and the mean kappa score was 0.909. There was high specificity and sensitivity in the value observed. The agreement index, measured through Fleiss' kappa for six teeth conditions, reported the perfect agreement (0.867) among six examiners. Conclusions Under the limitations of the study, teledentistry using a mobile phone has acceptable accuracy for diagnosing caries in the older age group compared to a standard clinical dental examination.

SELECTION OF CITATIONS
SEARCH DETAIL
...