Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 384, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38172504

ABSTRACT

The multi-scale characterization of building materials is necessary to understand complex mechanical processes, with the goal of developing new more sustainable materials. To that end, imaging methods are often used in materials science to characterize the microscale. However, these methods compromise the volume of interest to achieve a higher resolution. Dark-field (DF) contrast imaging is being investigated to characterize building materials in length scales smaller than the resolution of the imaging system, allowing a direct comparison of features in the nano-scale range and overcoming the scale limitations of the established characterization methods. This work extends the implementation of a dual-phase X-ray grating interferometer (DP-XGI) for DF imaging in a lab-based setup. The interferometer was developed to operate at two different design energies of 22.0 keV and 40.8 keV and was designed to characterize nanoscale-size features in millimeter-sized material samples. The good performance of the interferometer in the low energy range (LER) is demonstrated by the DF retrieval of natural wood samples. In addition, a high energy range (HER) configuration is proposed, resulting in higher mean visibility and good sensitivity over a wider range of correlation lengths in the nanoscale range. Its potential for the characterization of mineral building materials is illustrated by the DF imaging of a Ketton limestone. Additionally, the capability of the DP-XGI to differentiate features in the nanoscale range is proven with the dark-field of Silica nanoparticles at different correlation lengths of calibrated sizes of 106 nm, 261 nm, and 507 nm.

2.
Micromachines (Basel) ; 14(8)2023 Aug 18.
Article in English | MEDLINE | ID: mdl-37630166

ABSTRACT

Reactive ion etching (RIE) is the dominating technology for micromachining semiconductors with a high aspect ratio (HAR) [...].

3.
Sci Rep ; 13(1): 2731, 2023 02 15.
Article in English | MEDLINE | ID: mdl-36792717

ABSTRACT

Respiratory diseases are one of the most common causes of death, and their early detection is crucial for prompt treatment. X-ray dark-field radiography (XDFR) is a promising tool to image objects with unresolved micro-structures such as lungs. Using Talbot-Lau XDFR, we imaged inflated porcine lungs together with Polymethylmethacrylat (PMMA) microspheres (in air) of diameter sizes between 20 and 500 [Formula: see text] over an autocorrelation range of 0.8-5.2 [Formula: see text]. The results indicate that the dark-field extinction coefficient of porcine lungs is similar to that of densely-packed PMMA spheres with diameter of [Formula: see text], which is approximately the mean alveolar structure size. We evaluated that, in our case, the autocorrelation length would have to be limited to [Formula: see text] in order to image [Formula: see text]-thick lung tissue without critical visibility reduction (signal saturation). We identify the autocorrelation length to be the critical parameter of an interferometer that allows to avoid signal saturation in clinical lung dark-field imaging.


Subject(s)
Lung , Polymethyl Methacrylate , Animals , Swine , Lung/diagnostic imaging , Radiography , X-Rays
4.
Appl Opt ; 61(13): 3850-3854, 2022 May 01.
Article in English | MEDLINE | ID: mdl-36256429

ABSTRACT

Precisely aligned optical components are crucial prerequisites for X-ray tomography at high resolution. We propose a device with a fractal pattern for precise automatic focusing. The device is etched in a Si substrate by deep reactive ion etching and then filled by a self-terminating bottom-up Au electroplating process. The fractal nature of the device produces an X-ray transmission image with globally homogeneous macroscopic visibility and high local contrast for pixel sizes in the range of 0.165 µm to 11 µm, while the high absorption contrast provided between Au and Si enables its use for X-ray energies ranging from 12 keV to 40 keV.

5.
Opt Lett ; 46(15): 3693-3696, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-34329258

ABSTRACT

The orientation mismatch between the cone beam of an X-ray tube and the grating lines in a flat substrate remains a big challenge for laboratory grating-based X-ray interferometry, since it severely limits the imaging field of view. Here, we fabricated fan-shaped G0 source gratings by modulating the electric field during the deep reactive ion etching of silicon. The gold electroplated fan-shaped G0 grating (3.0 µm pitch) in a 20 keV interferometer improves the uniformity of the field of view with an increase of average visibility from 16.2% to 18.5% and a better angular sensitivity (by a factor 5.8) at the edges.

6.
Micromachines (Basel) ; 12(5)2021 May 07.
Article in English | MEDLINE | ID: mdl-34066906

ABSTRACT

We present a method to produce small pitch gratings for X-ray interferometric imaging applications, allowing the phase sensitivity to be increased and/or the length of the laboratory setup to be minimized. The method is based on fabrication of high aspect ratio silicon microstructures using deep reactive ion etching (Bosch technique) of dense grating arrays and followed by conformal electroplating of Au. We demonstrated that low resistivity Si substrates (<0.01 Ohm·cm) enable the metal seeding layer deposition step to be avoided, which is normally required to initiate the electroplating process. Etching conditions were optimized to realize Si recess structures with a slight bottom tapering, which ensured the void-free Au filling of the trenches. Vapor HF was used to remove the native oxide layer from the Si grating surface prior to electroplating in the cyanide-based Au electrolyte. Fabrication of Au gratings with pitch in the range 1.2-3.0 µm was successfully realized. A substantial improved aspect ratio of 45:1 for a pitch size of 1.2 µm was achieved with respect to the prior art on 4-inch wafer-based technology. The fabricated Au gratings were tested with X-ray interferometers in Talbot-Laue configuration with measured visibility of 13% at an X-ray design energy of 26 keV.

7.
Opt Express ; 29(2): 2049-2064, 2021 Jan 18.
Article in English | MEDLINE | ID: mdl-33726406

ABSTRACT

X-ray phase contrast imaging is a powerful analysis technique for materials science and biomedicine. Here, we report on laboratory grating-based X-ray interferometry employing a microfocus X-ray source and a high Talbot order (35th) asymmetric geometry to achieve high angular sensitivity and high spatial resolution X-ray phase contrast imaging in a compact system (total length <1 m). The detection of very small refractive angles (∼50 nrad) at an interferometer design energy of 19 keV was enabled by combining small period X-ray gratings (1.0, 1.5 and 3.0 µm) and a single-photon counting X-ray detector (75 µm pixel size). The performance of the X-ray interferometer was fully characterized in terms of angular sensitivity and spatial resolution. Finally, the potential of laboratory X-ray phase contrast for biomedical imaging is demonstrated by obtaining high resolution X-ray phase tomographies of a mouse embryo embedded in solid paraffin and a formalin-fixed full-thickness sample of human left ventricle in water with a spatial resolution of 21.5 µm.


Subject(s)
Embryo, Mammalian/diagnostic imaging , Heart Ventricles/diagnostic imaging , Interferometry/instrumentation , Microscopy, Phase-Contrast/instrumentation , Tomography, X-Ray Computed/methods , Animals , Equipment Design , Humans , Image Processing, Computer-Assisted/methods , Mice , Paraffin Embedding
8.
Micromachines (Basel) ; 11(9)2020 Sep 18.
Article in English | MEDLINE | ID: mdl-32961900

ABSTRACT

The key optical components of X-ray grating interferometry are gratings, whose profile requirements play the most critical role in acquiring high quality images. The difficulty of etching grating lines with high aspect ratios when the pitch is in the range of a few micrometers has greatly limited imaging applications based on X-ray grating interferometry. A high etching rate with low aspect ratio dependence is crucial for higher X-ray energy applications and good profile control by deep reactive ion etching of grating patterns. To achieve this goal, a modified Coburn-Winters model was applied in order to study the influence of key etching parameters, such as chamber pressure and etching power. The recipe for deep reactive ion etching was carefully fine-tuned based on the experimental results. Silicon gratings with an area of 70 × 70 mm2, pitch size of 1.2 and 2 µm were fabricated using the optimized process with aspect ratio α of ~67 and 77, respectively.

9.
Nanoscale Horiz ; 5(5): 869-879, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32100775

ABSTRACT

High aspect ratio nanostructuring requires high precision pattern transfer with highly directional etching. In this work, we demonstrate the fabrication of structures with ultra-high aspect ratios (up to 10 000 : 1) in the nanoscale regime (down to 10 nm) by platinum assisted chemical etching of silicon in the gas phase. The etching gas is created by a vapour of water diluted hydrofluoric acid and a continuous air flow, which works both as an oxidizer and as a gas carrier for reactive species. The high reactivity of platinum as a catalyst and the formation of platinum silicide to improve the stability of the catalyst pattern allow a controlled etching. The method has been successfully applied to produce straight nanowires with section size in the range of 10-100 nm and length of hundreds of micrometres, and X-ray optical elements with feature sizes down to 10 nm and etching depth in the range of tens of micrometres. This work opens the possibility of a low cost etching method for stiction-sensitive nanostructures and a large range of applications where silicon high aspect ratio nanostructures and high precision of pattern transfer are required.

10.
Eur Radiol ; 30(3): 1823, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31897597

ABSTRACT

The article Towards clinical grating-interferometry mammography, written by Carolina Arboleda, Zhentian Wang, Konstantins Jefimovs, Thomas Koehler, Udo Van Stevendaal, Norbert Kuhn, Bernd David, Sven Prevrhal, Kristina Lång, Serafino Forte, Rahel Antonia Kubik-Huch, Cornelia Leo.

11.
Eur Radiol ; 30(3): 1419-1425, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31440834

ABSTRACT

OBJECTIVES: Grating-interferometry-based mammography (GIM) might facilitate breast cancer detection, as several research works have demonstrated in a pre-clinical setting, since it is able to provide attenuation, differential phase contrast, and scattering images simultaneously. In order to translate this technique to the clinics, it has to be adapted to cover a large field-of-view within a clinically acceptable exposure time and radiation dose. METHODS: We set up a grating interferometer that fits into a standard mammography system and fulfilled the aforementioned conditions. Here, we present the first mastectomy images acquired with this experimental device. RESULTS AND CONCLUSION: Our system performs at a mean glandular dose of 1.6 mGy for a 5-cm-thick, 18%-dense breast, and a field-of-view of 26 × 21 cm2. It seems to be well-suited as basis for a clinical-environment device. Further, dark-field signals seem to support an improved lesion visualization. Evidently, the effective impact of such indications must be evaluated and quantified within the context of a proper reader study. KEY POINTS: • Grating-interferometry-based mammography (GIM) might facilitate breast cancer detection, since it is sensitive to refraction and scattering and thus provides additional tissue information. • The most straightforward way to do grating-interferometry in the clinics is to modify a standard mammography device. • In a first approximation, the doses given with this technique seem to be similar to those of conventional mammography.


Subject(s)
Breast Neoplasms/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Mammography/methods , Neoplasms, Multiple Primary/diagnostic imaging , Breast Density , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/pathology , Carcinoma, Ductal, Breast/surgery , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Intraductal, Noninfiltrating/surgery , Female , Humans , Interferometry/methods , Mastectomy , Neoplasms, Multiple Primary/pathology , Neoplasms, Multiple Primary/surgery , Radiation Dosage , Tumor Burden
12.
Nat Commun ; 10(1): 5130, 2019 11 12.
Article in English | MEDLINE | ID: mdl-31719528

ABSTRACT

Insights into the micro- and nano-architecture of materials is crucial for understanding and predicting their macroscopic behaviour. In particular, for emerging applications such as meta-materials, the micrometer scale becomes highly relevant. The micro-architecture of such materials can be tailored to exhibit specific mechanical, optical or electromagnetic behaviours. Consequently, quality control at micrometer scale must be guaranteed over extended areas. Mesoscale investigations over millimetre sized areas can be performed by scanning small angle X-ray scattering methods (SAXS). However, due to their long measurement times, real time or operando investigations are hindered. Here we present a method based on X-ray diffractive optics that enables the acquisition of SAXS signals in a single shot (few milliseconds) over extended areas. This method is applicable to a wide range of X-ray sources with varying levels of spatial coherence and monochromaticity, as demonstrated from the experimental results. This enables a scalable solution of spatially resolved SAXS.

13.
Eur Radiol Exp ; 3(1): 19, 2019 05 21.
Article in English | MEDLINE | ID: mdl-31115796

ABSTRACT

Grating interferometry mammography (GIM) is an experimental breast imaging method at the edge of being clinically implemented. Besides attenuation, GIM can measure the refraction and scattering of x-rays resulting in differential phase contrast (DPC) and dark-field (DF) images. In this exploratory study, we assessed the feasibility of using microbubbles as a contrast agent in GIM. Two millilitres of microbubbles and iodine were respectively injected into ex vivo breast phantoms, consisting of fresh chicken breasts. Native and postcontrast images were acquired with a clinically compatible GIM setup, operated at 38 kVp, 14-s acquisition time, and with a dose of 1.3 mGy. The visibility of the contrast agents was analysed in a side-by-side comparison by three radiologists. The contrast-to-noise-ratio (CNR) was calculated for each contrast agent. We found that both contrast agents were judged to be visible by the readers. The mean CNR was 3.1 ± 1.9 for microbubbles in DF and 24.2 ± 6.5 for iodine in attenuation. In conclusion, this is a first proof-of-mechanism study that microbubbles could be used as a contrast agent in clinically compatible GIM, due to their scattering properties, which implies the potential use of a contrast agent with a high safety profile in x-ray-based breast imaging.


Subject(s)
Contrast Media , Interferometry , Mammography/methods , Microbubbles , Animals , Chickens , Feasibility Studies , Iodine
14.
Phys Rev Lett ; 118(26): 265501, 2017 Jun 30.
Article in English | MEDLINE | ID: mdl-28707948

ABSTRACT

Small angle x-ray scattering has been proven to be a valuable method for accessing structural information below the spatial resolution limit implied by direct imaging. Here, we theoretically derive the relation that links the subpixel differential phase signal provided by the sample to the moments of scattering distributions accessible by refraction sensitive x-ray imaging techniques. As an important special case we explain the scatter or dark-field contrast in terms of the sample's phase signal. Further, we establish that, for binary phase objects, the nth moment scales with the difference of the refractive index decrement to the power of n. Finally, we experimentally demonstrate the utility of the moments by quantitatively determining the particle sizes of a range of powders with a laboratory-based setup.

15.
Phys Rev E ; 95(6-1): 062601, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28709299

ABSTRACT

Dense colloidal dispersions exhibit complex wave-vector-dependent diffusion, which is controlled by both direct particle interactions and indirect nonadditive hydrodynamic interactions mediated by the solvent. In bulk the hydrodynamic interactions are probed routinely, but in confined geometries their studies have been hitherto hindered by additional complications due to confining walls. Here we solve this issue by combining high-energy x-ray photon correlation spectroscopy and small-angle x-ray-scattering experiments on colloid-filled microfluidic channels to yield the confined fluid's hydrodynamic function in the short-time limit. Most importantly, we find the confined fluid to exhibit a strongly anisotropic hydrodynamic function, similar to its anisotropic structure factor. This observation is important in order to guide future theoretical research.

16.
Sci Rep ; 7: 44588, 2017 03 17.
Article in English | MEDLINE | ID: mdl-28303923

ABSTRACT

Neutron imaging and scattering give data of significantly different nature and traditional methods leave a gap of accessible structure sizes at around 10 micrometers. Only in recent years overlap in the probed size ranges could be achieved by independent application of high resolution scattering and imaging methods, however without providing full structural information when microstructures vary on a macroscopic scale. In this study we show how quantitative neutron dark-field imaging with a novel experimental approach provides both sub-pixel resolution with respect to microscopic correlation lengths and imaging of macroscopic variations of the microstructure. Thus it provides combined information on multiple length scales. A dispersion of micrometer sized polystyrene colloids was chosen as a model system to study gravity induced crystallisation of microspheres on a macro scale, including the identification of ordered as well as unordered phases. Our results pave the way to study heterogeneous systems locally in a previously impossible manner.

17.
Opt Express ; 25(2): 1019-1029, 2017 Jan 23.
Article in English | MEDLINE | ID: mdl-28157983

ABSTRACT

The performance of X-ray and neutron grating interferometers is characterised by their visibility, which is a measure for the maximum achievable contrast. In this study we show how the real grating geometry in a grating interferometer with three gratings impacts the interference and self projection that leads to visibility in the first place. We quantify the individual contributions of wavelength distributions and grating shapes in terms of visibility reduction by determining the absolute as well as relative effect of each contribution. The understanding of the impact of changed geometry and wavelength distributions on the interference of neutrons/X-rays allows us to present the first fully quantitative model of a grating interferometer setup. We demonstrate the capability of the simulation framework by building a model of the neutron grating interferometer at the ICON beamline and directly comparing simulated and measured visibility values. The general nature of the model makes it possible to extend it to any given grating interferometer for both X-rays and neutrons.

18.
Phys Rev Lett ; 116(16): 167801, 2016 Apr 22.
Article in English | MEDLINE | ID: mdl-27152823

ABSTRACT

The collective diffusion of dense fluids in spatial confinement is studied by combining high-energy (21 keV) x-ray photon correlation spectroscopy and small-angle x-ray scattering from colloid-filled microfluidic channels. We find the structural relaxation in confinement to be slower compared to the bulk. The collective dynamics is wave vector dependent, akin to the de Gennes narrowing typically observed in bulk fluids. However, in stark contrast to the bulk, the structure factor and de Gennes narrowing in confinement are anisotropic. These experimental observations are essential in order to develop a microscopic theoretical description of collective diffusion of dense fluids in confined geometries.

19.
Phys Rev Lett ; 116(9): 093902, 2016 Mar 04.
Article in English | MEDLINE | ID: mdl-26991177

ABSTRACT

X-ray scattering imaging can provide complementary information to conventional absorption based radiographic imaging about the unresolved microstructures of a sample. The scattering signal can be accessed with various methods based on coherent illumination, which span from self-imaging to speckle scanning. The directional sensitivity of the existing real space imaging methods is limited to a few directions on the imaging plane and requires scanning of the optical components, or the rotation of either the sample or the imaging setup, in order to cover the full range of possible scattering directions. In this Letter the authors propose a new method that allows the simultaneous acquisition of scattering images in all possible directions in a single shot. This is achieved by a specialized phase grating and a detector with sufficient spatial resolution to record the generated interference fringe. The structural length scale sensitivity of the system can be tuned by varying its geometry for a fixed grating design. Taking into account ongoing developments in the field of compact x-ray sources that allow high brightness and sufficient spatial coherence, the applicability of omnidirectional scattering imaging in industrial and medical settings is boosted significantly.

20.
Rapid Commun Mass Spectrom ; 29(11): 1019-24, 2015 Jun 15.
Article in English | MEDLINE | ID: mdl-26044268

ABSTRACT

RATIONALE: Up to now, there is no 'gold standard' for determining the resolution of a mass spectrometry imaging (MSI) setup (comprising the instrument, the sample preparation, the sample and the instrument settings). A standard sample in combination with a standard protocol to define the MSI resolution would be desirable in order to compare the setups of different laboratories, and as a regular quality control/performance check. METHODS: Microstructured resolution patterns were fabricated that can be used to determine the spatial resolution in MSI experiments, down to the range of a few µm. Two different strategies were employed, one where the resolution pattern is laser machined into a thin metal foil, which can be placed over a sample to be imaged, and a second one where hydrophilic grooves are machined into an omniphobic coating covering the surface of an indium tin oxide covered glass slide. When dragging a sample solution over the slide's surface, the sample is automatically retained in the hydrophilic grooves, but repelled by the omniphobic coating. RESULTS: The technology was tested on a commercial matrix-assisted laser desorption/ionization (MALDI) imaging instrument, and a spatial resolution in the vicinity of 50 µm was determined. The finest features of the microstructured resolution patterns are compatible with the best spatial resolution of MALDI imaging systems available to date. CONCLUSIONS: The use of metal resolution grids or glass slides with hydrophilic/hydrophobic structures is suitable for the convenient determination of the resolution limit of the MALDI imaging instrument as determined by its hardware. These structures are straightforward both to produce and to use.


Subject(s)
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation , Angiotensin II/chemistry , Photography , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Tungsten/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...