Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Front Pediatr ; 11: 1244704, 2023.
Article in English | MEDLINE | ID: mdl-37691775

ABSTRACT

Background: The distal radial metaphyseal-diaphysis junction fractures (DRMDJ) have various treatment methods and are easily lead to complications. This study aims to compare the anterograde elastic stable intramedullary nailing (ESIN-A), retrograde K-wire fixation (KW-R), and retrograde precision-shaping elastic intramedullary nailing (ESIN-RPS) for the treatment of pediatric DRMDJ fractures. Materials and methods: A total of 113 patients with DRMDJ fractures (36 in the ESIN-A group, 52 in the KW-R group, and 25 in the ESIN-RPS group) from two centres were retrospectively analysed. Perioperative operation time, intraoperative bleeding, fluoroscopy times, alignment rate and angulation on radiography were compared among the three groups. Forearm rotation, healing, wrist function, and complications were compared at the last follow-up. Results: The mean operation times of the three groups were as follows: KW-R (72 ± 13 min) > ESIN-A (65 ± 18 min) > ESIN-RPS (52 ± 11 min), with a significant difference (P < 0.01). The incision length and intraoperative blood loss of ESIN-A (1.8 ± 0.2 cm; 8.3 ± 3.7 ml) were significantly higher than ESIN-RPS (1.4 ± 0.8 cm; 5.5 ± 2.7 ml) (P < 0.05), respectively. The postoperative alignment rate on the anteroposterior (AP) and the lateral plane of ESIN-RPS (93.1 ± 4.4%; 95.01 ± 2.8%) was significantly greater than that of KW-R (82.1 ± 6.8%; 88.5 ± 4.5%) and ESIN-A (79.2 ± 5.2%; 83.2 ± 2.5%) (P < 0.01). The residual angulation of ESIN-RPS (3.3 ± 1.2°; 2.9 ± 0.8°) was significantly greater than that for ESIN-A (5.1 ± 1.7°; 4.9 ± 2.1°) and KW-R (6.6 ± 2.8°; 7.5 ± 1.6°) (P < 0.05). The excellent and good ratio of ESIN-RPS (95.8%) was significantly higher than that of ESIN-A (86.5%) and KW-R (86.1%) according to the Gartland-Werley standard. There was a significant difference in delayed union between the KW-R and ESIN-A (P < 0.05). Additionally, there were two cases of radial nerve injury in the ESIN-A group, one case of tendon rupture in the ESIN-RPS group, and one case of tendon rupture in the KW-R group. The ESIN-RPS group had significantly fewer complications than the KW-R group (P < 0.05). The ESIN-A group also had significantly fewer complications than the KW-R group (P < 0.05). Conclusion: Compared with ESIN-A and KW-R, ESIN-RPS has the advantages of a shorter operation time, less intraoperative blood loss, less radiation, better alignment, and fewer complications. The ESIN-RPS was suggested as an optimal choice for paediatric DRMDJ fractures.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-992763

ABSTRACT

Objective:To compare the effects of anterograde elastic stable intramedullary nailing (ESIN-A), retrograde K-wires fixation (KW-R) and retrograde precision shaping of elastic stable intramedullary nailing (ESIN-RPS) in the treatment of fractures of distal radial metaphyseal diaphyseal junction (DRMDJ) in children.Methods:A retrospective study was conducted to analyze the data of 112 eligible children with DRMDJ fracture who had been treated at Department of Orthopedics, Children's Hospital, Anhui Medical University and Department of Orthopedics, The People's Hospital of Fuyang City,Anhui Medical University, from January 2016 to May 2022. There were 64 males and 48 females, with an age of (8.4±2.3) years. The children were divided into 3 groups according to different surgical fixation methods: group ESIN-A of 36 cases, group KW-R of 52 cases, and group ESIN-RPS of 24 cases. The operation time, intraoperative bleeding, fluoroscopy times, alignment rates and residual angulations by the anteroposterior and lateral X-ray films immediately after reduction were compared among the 3 groups. The Gartland-Werley evaluation of wrist function and complications were compared at the last follow-up.Results:There was no statistically significant difference in the preoperative general data among the 3 groups, indicating comparability ( P>0.05). In the operation time, group KW-R [(71.2±9.2) min] > group ESIN-A [(65.1±13.1) min] > group ESIN-RPS [(51.7±17.1) min]; in the fluoroscopy times, group KW-R [(13.9±6.3) times] > group ESIN-A [(9.0±2.8) times] > group ESIN-RPS [(6.4±2.0) times]; in the alignment rates by the anteroposterior and lateral X-ray films immediately after reduction, group ESIN-RPS (93.1%±4.6% and 95.2%±3.3%) > group KW-R (82.1%±11.0% and 88.1%±7.4%) > group ESIN-A (80.4%±9.9% and 86.7%±6.9%); in the residual angulations by the anteroposterior and lateral X-ray films immediately after reduction, group ESIN-RPS (3.3°±1.8° and 2.9°±2.1°) < group ESIN-A (5.2°±1.0° and 5.0°±3.2°) < group KW-R (6.6°±1.6°and 7.5°±2.7°). Pairwise comparisons in the above items were statistically significant ( P<0.05). In group ESIN-A, the incision length [(1.8±0.3) cm] was significantlylonger than that in group ESIN-RPS [(1.4±0.2) cm], and the intraoperative blood loss [(8.3±2.2) mL] significantly larger than that in group ESIN-RPS [(5.5±1.6) mL] ( P<0.05). One year after operation, the excellent and good rate by the Gartland-Werley evaluation of wrist function in groups ESIN-RPS, ESIN-A and KW-R, respectively, were 95.8% (23/24), 86.5% (31/36) and 86.1% (46/52), showing no statistically significant difference between the 3 group ( P>0.05), and the major incidence of complications in group KW-R (25.0%, 13/52) and in group ESIN-A (25.0%, 9/36) were significantly higher than that in group ESIN-RPS (4.2%, 1/24) ( P<0.05). Conclusion:In the treatment of DRMDJ fractures in children, compared with ESIN-A and KW-R, ESIN-RPS is an effective choice due to its advantages of shorter operation time, less intraoperative blood loss, less radiation, better alignment, and fewer complications.

3.
Chinese Journal of Orthopaedics ; (12): 1084-1092, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-957102

ABSTRACT

Methods:Two thousand standard sections images werre collected from 2 000 clinical retrospective pediatric hip ultrasound videos from January 2019 to January 2021. All standard sections were annotated by the annotation team through the self-designed software based on Python 3.6 environment for image cross-media data annotation and manual review standardization process with unified standards. Among them, 1 753 were randomly selected for training the deep learning system, and the remaining 247 were used for testing the system. Further, 200 standard sections were randomly selected from the test set, and 8 clinicians independently completed the film reading annotation. The 8 independent results were then compared with the AI results.Results:The testing set consists of 247 patients. Compared with the clinician's measurements, the area under the receiver operating characteristic curve (AUC) of diagnosing hip joint maturity was 0.865, the sensitivity was 76.19%, and the specificity was 96.9%. The AUC of AI system interpretation under Graf detailed typing was 0.575, the sensitivity was 25.90%, the specificity was 89.10%. The 95% LoA of α-angle determined by Bland-Altman method, of -4.7051° to 6.5948° ( Bias -0.94, P<0.001), compared with clinicians' measurements. The 95% LoA of β-angle, of -7.7191 to 6.8777 ( Bias -0.42, P=0.077). Compared with those from 8 clinicians, the results of AI system interpretation were more stable, and the β-angle effect was more prominent. Conclusion:The AI system can quickly and accurately measure the Graf correlation index of standard DDH ultrasonic standard diagnosis plane.

4.
Front Bioeng Biotechnol ; 9: 696166, 2021.
Article in English | MEDLINE | ID: mdl-34277590

ABSTRACT

With the development of modern chemical synthesis technology, toxic and harmful compounds increase sharply. In order to improve the removal efficiency of refractory organic matter in waste water, the method of adding powdered activated carbon (PAC) to the system for adsorption was adopted. Through the analysis of organic matter removal rule before and after waste water treatment, it can be found that PAC is easy to adsorb hydrophobic organic matter, while activated sludge is easy to remove hydrophilic and weakly hydrophobic neutral organic matter. Powdered activated carbon-activated sludge SBR system (PAC-AS) system is obviously superior to AS and PAC system in removing organic matter of hydrophilic and hydrophobic components, that is, biodegradation and PAC adsorption are additive. Compared with the control system, the Chemical Oxygen Demand (COD) removal rate of refractory substances increased by 8.36%, and PAC had a good adsorption effect on small molecular weight organic compounds, but with the increase of molecular weight of organic compounds, the adsorption effect of PAC gradually weakened, and it had no adsorption effect on macromolecular organic compounds. Based on the research of fuzzy control theory, an Agent control system for ozone oxidation process of industrial waste water based on Mobile Agent Server (MAS) theory was established, which was realized by fuzzy control method. The simulation results showed strong stability and verified the feasibility and adaptability of the distributed intelligent waste water treatment system based on MAS theory in the actual control process.

SELECTION OF CITATIONS
SEARCH DETAIL