1.
JAMA Netw Open ; 6(9): e2334069, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37713196

ABSTRACT

Importance: Prenatal cardiac screening of the first and second trimesters has had a major impact on postnatal prevalence of congenital heart defects (CHDs), rates of termination of pregnancy (TOP), and outcomes among children born alive with CHDs. Objective: To examine the prenatal and postnatal incidence of major CHDs (ie, necessitating intervention within the first year of life), detection rate trends, rates of TOP, and the association of cardiac screening with postnatal outcomes. Design, Settings, and Participants: In this cross-sectional study, 3827 fetuses with antenatally diagnosed major CHDs in the Czech Republic (population 10.7 million) between 1991 and 2021 were prospectively evaluated with known outcomes and associated comorbidities. Prenatal and postnatal prevalence of CHD in an unselected population was assessed by comparison with a retrospective analysis of all children born alive with major CHDs in the same period (5454 children), using national data registry. Data analysis was conducted from January 1991 to December 2021. Main Outcomes and Measures: Prenatal detection and postnatal prevalence of major CHDs and rate of TOPs in a setting with a centralized health care system over 31 years. Results: A total of 3 300 068 children were born alive during the study period. Major CHD was diagnosed in 3827 fetuses, of whom 1646 (43.0%) were born, 2069 (54.1%) resulted in TOP, and 112 (2.9%) died prenatally. The prenatal detection rate increased from 6.2% in 1991 to 82.8% in 2021 (P < .001). Termination of pregnancy decreased from 70% in 1991 to 43% (P < .001) in 2021. Of 627 fetuses diagnosed in the first trimester (introduced in 2007), 460 were terminated (73.3%). Since 2007, of 2066 fetuses diagnosed in the second trimester, 880 (42.6%) were terminated, resulting in an odds ratio of 3.6 (95% CI, 2.8-4.6; P < .001) for TOP in the first trimester compared with the second trimester. Postnatal prevalence of major CHDs declined from 0.21% to 0.14% (P < .001). The total incidence (combining prenatal detection of terminated fetuses with postnatal prevalence) of major CHD remained at 0.23% during the study period. Conclusions and Relevance: In this cross-sectional study, the total incidence of major CHD did not change significantly during the 31-year study period. The prenatal detection of major CHD approached 83% in the current era. Postnatal prevalence of major CHD decreased significantly due to early TOPs and intrauterine deaths. The introduction of first trimester screening resulted in a higher termination rate in the first trimester but did not revert the overall decreasing trend of termination for CHDs in general.


Subject(s)
Abortion, Induced , Heart Defects, Congenital , Child , Female , Pregnancy , Humans , Cross-Sectional Studies , Prevalence , Retrospective Studies , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/epidemiology
2.
Front Genet ; 11: 561054, 2020.
Article in English | MEDLINE | ID: mdl-33133147

ABSTRACT

Congenital disorders of glycosylation (CDG) are a rapidly growing family of genetic diseases with the phosphomannomutase 2 (PMM2)-CDG being the most common form of CDG. Most of these monogenic diseases are autosomal recessive and have multi-systemic manifestations, mainly psychomotor retardation, facial dysmorphisms, characteristic distribution of the fat pads, and variable coagulation abnormalities. The association of fetal hydrops with CDG has been reported, and pericardial effusion was also rarely observed in patients with PMM2-CDG. Here we describe an infant boy with PMM2-CDG. The diagnosis was suspected based on inverted nipples, fat pads, and combined coagulopathy. However, the primary symptom was progressive pericardial effusion leading to patient death at the age of 3 months. Screening for CDG performed by the use of isoelectric focusing of serum transferrin showed a typical PMM2-CDG pattern. Exome sequencing revealed one common pathogenic variant (c.691G > A/p.Val231Met) and one novel variant (c.447 + 3dupA) in the PMM2 gene. Both PMM2 variants were further confirmed by Sanger sequencing in both the proband and the parents' DNA. The novel variant was predicted to result in loss of donor splice site, and the analysis at mRNA level confirmed that it leads to exon five skipping (r.348_447del) and causes premature termination of translation to the protein (p.G117Kfs∗4), therefore is classified as likely pathogenic. Although there is no curative therapy for the PMM2-CDG at the moment, the other supportive care options are available to be offered. The definite diagnosis of PMM2-CDG can also assist in the process of genetic counseling, family planning, and preimplantation genetic diagnosis.

4.
Circulation ; 135(11): 1045-1055, 2017 Mar 14.
Article in English | MEDLINE | ID: mdl-28143885

ABSTRACT

BACKGROUND: The study analyzed the impact of first-trimester screening on the spectrum of congenital heart defects (CHDs) later in pregnancy and on the outcome of fetuses and children born alive with a CHD. METHODS: The spectrum of CHDs, associated comorbidities, and outcome of fetuses, either diagnosed with a CHD in the first trimester (Group I, 127 fetuses) or only in the second-trimester screening (Group II, 344 fetuses), were analyzed retrospectively between 2007 and 2013. Second-trimester fetuses diagnosed with a CHD between 2007 and 2013 were also compared with Group III (532 fetuses diagnosed with a CHD in the second trimester from 1996 to 2001, the period before first-trimester screening was introduced). RESULTS: The spectrum of CHDs diagnosed in the first and second trimesters in the same time period differed significantly, with a greater number of comorbidities (P<0.0001), CHDs with univentricular outcome (P<0.0001), intrauterine deaths (P=0.01), and terminations of pregnancy (P<0.0001) in Group I compared with Group II. In Group III, significantly more cases of CHDs with univentricular outcome (P<0.0001), intrauterine demise (P=0.036), and early termination (P<0.0001) were identified compared with fetuses diagnosed with CHDs in the second trimester between 2007 and 2013. The spectrum of CHDs seen in the second-trimester groups differed after first-trimester screening was implemented. CONCLUSIONS: First-trimester screening had a significant impact on the spectrum of CHDs and the outcomes of pregnancies with CHDs diagnosed in the second trimester. Early detection of severe forms of CHDs and significant comorbidities resulted in an increased pregnancy termination rate in the first trimester.


Subject(s)
Heart Defects, Congenital/diagnosis , Chromosome Aberrations , Comorbidity , Czech Republic , Echocardiography , Female , Fetus/diagnostic imaging , Heart Defects, Congenital/epidemiology , Heart Defects, Congenital/genetics , Humans , Pregnancy , Pregnancy Trimester, First , Pregnancy Trimester, Second , Retrospective Studies , Ultrasonography, Prenatal
5.
Int Arch Allergy Immunol ; 170(4): 251-256, 2016.
Article in English | MEDLINE | ID: mdl-27685423

ABSTRACT

The Fontan operation or total cavopulmonal connection (TCPC) is a palliative surgical correction of rare and complex inborn cardiac malformations that are characterized by univentricular circulation. Protein-losing enteropathy (PLE) develops in 4-13% of patients after the Fontan procedure. Fontan-related PLE leads to secondary combined immunodeficiency marked by hypogammaglobulinemia and predominantly CD4+ lymphocytopenia. Here, we present 3 case reports of patients with secondary immunodeficiency after the Fontan operation. The severity of hypogammaglobulinemia correlated with the nature of the infectious complications; however, clinical manifestations of T cell deficiency such as severe viral or opportunistic infections were not observed. The clinical consequences of the secondary combined immunodeficiency were modified by immunoglobulin replacement treatment and antibiotic prophylaxis. Heart transplantation led to the resolution of PLE signs and the restitution of IgG levels in 1 transplanted patient. Our experience shows that the immunological follow-up was delayed in all 3 patients. We suggest that all patients should be followed regularly by a clinical immunologist after the Fontan surgery.


Subject(s)
Fontan Procedure/adverse effects , Severe Combined Immunodeficiency/diagnosis , Severe Combined Immunodeficiency/etiology , Agammaglobulinemia/blood , Agammaglobulinemia/immunology , Child , Child, Preschool , Female , Humans , Immunoglobulin Isotypes/blood , Immunophenotyping , Lymphocyte Count , Lymphopenia/blood , Lymphopenia/immunology , Male
6.
Circulation ; 124(18): 1919-26, 2011 Nov 01.
Article in English | MEDLINE | ID: mdl-21986286

ABSTRACT

BACKGROUND: Isolated complete atrioventricular block in the fetus is a rare but potentially lethal condition in which the effect of steroid treatment on outcome is unclear. The objective of this work was to study risk factors associated with death and the influence of steroid treatment on outcome. METHODS AND RESULTS: We studied 175 fetuses diagnosed with second- or third-degree atrioventricular block (2000-2007) retrospectively in a multinational, multicenter setting. In 80% of 162 pregnancies with documented antibody status, atrioventricular block was associated with maternal anti-Ro/SSA antibodies. Sixty-seven cases (38%) were treated with fluorinated corticosteroids for a median of 10 weeks (1-21 weeks). Ninety-one percent were alive at birth, and survival in the neonatal period was 93%, similar in steroid-treated and untreated fetuses, regardless of degree of block and/or presence of anti-Ro/SSA. Variables associated with death were gestational age < 20 weeks, ventricular rate ≤ 50 bpm, fetal hydrops, and impaired left ventricular function at diagnosis. The presence of ≥ 1 of these variables was associated with a 10-fold increase in mortality before birth and a 6-fold increase in the neonatal period independently of treatment. Except for a lower gestational age at diagnosis in treated than untreated (23.4 ± 2.9 versus 24.9 ± 4.9 weeks; P=0.02), risk factors were distributed equally between treatment groups. Two-thirds of survivors had a pacemaker by 1 year of age; 8 children developed cardiomyopathy. CONCLUSIONS: Risk factors associated with a poor outcome were gestation < 20 weeks, ventricular rate ≤ 50 bpm, hydrops, and impaired left ventricular function. No significant effect of treatment with fluorinated corticosteroids was seen.


Subject(s)
Atrioventricular Block/mortality , Fetal Death/epidemiology , Fetal Diseases/mortality , Adult , Antibodies, Antinuclear/blood , Atrioventricular Block/drug therapy , Atrioventricular Block/immunology , Female , Fetal Diseases/drug therapy , Fetal Diseases/immunology , Gestational Age , Humans , Infant, Newborn , Plasmapheresis , Pregnancy , Pregnancy Outcome/epidemiology , Retrospective Studies , Risk Factors , Steroids/therapeutic use , Young Adult
7.
Circulation ; 118(18): 1793-801, 2008 Oct 28.
Article in English | MEDLINE | ID: mdl-18852365

ABSTRACT

BACKGROUND: Prenatal diagnosis of aortic coarctation suffers from high false-negative rates at screening and poor specificity. METHODS AND RESULTS: This retrospective study tested the applicability of published aortic arch and ductal Z scores (measured just before the descending aorta in the 3-vessel and tracheal view) and their ratio on 200 consecutive normal controls at a median of 22+/-0 gestational weeks (range, 15+/-4 to 38+/-4 weeks). Second, this study tested the ability of serial Z scores to distinguish fetuses with coarctation within a cohort with ventricular and/or great arterial disproportion detected at screening or fetal echocardiography. Third, it evaluated the diagnostic significance of associated cardiac lesions, coarctation shelf, and isthmal flow disturbance. We studied 44 fetuses with suspected coarctation at 24+/-0 weeks (range, 17+/-3 to 37+/-4 weeks). Receiver-operating characteristic curves were created. Logistic regression tested the association between z scores, additional cardiac diagnoses, and coarctation. Good separation was found of isthmal Z scores for cases requiring surgery from controls and false-positive cases, and receiver-operating characteristic curves showed an excellent area under the curve for isthmal Z score (0.963) and isthmal-to-ductal ratio (0.969). Serial isthmal Z scores improved to >-2 in suspected cases with normal outcomes; those requiring surveillance or surgery remained <-2. Minor lesions did not increase the diagnostic specificity of coarctation, but isthmal flow disturbance increased the odds ratio of true coarctation versus arch hypoplasia 16-fold. CONCLUSIONS: Isthmal Z scores and isthmal-to-ductal ratio are sensitive indicators of fetal coarctation. Serial measurements and abnormal isthmal flow patterns improve diagnostic specificity and may reduce false positives.


Subject(s)
Aortic Coarctation/diagnostic imaging , Aortic Coarctation/physiopathology , Echocardiography/standards , Ultrasonography, Prenatal/standards , Coronary Circulation , False Negative Reactions , Female , Gestational Age , Humans , Predictive Value of Tests , Pregnancy , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...