1.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Article in English | MEDLINE | ID: mdl-37725906

ABSTRACT

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Subject(s)
Clinical Laboratory Services , Laboratory Proficiency Testing , Humans , Reference Standards , Reagent Kits, Diagnostic
2.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37566391

ABSTRACT

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

4.
Clin Chem ; 69(3): 228-238, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36660772

ABSTRACT

Equivalent results for the same measurand in clinical samples (CSs), measured using different end-user in-vitro diagnostic medical devices (IVD-MDs), are essential for the application of clinical practice guidelines for diagnosis, treatment, monitoring, or risk assessment. The International Organization for Standardization (ISO) document 17511:2020 specifies how to establish metrological traceability to the highest available reference system component to enable equivalent results among IVD-MDs. Commutability with CSs is an essential property of a reference material used as a calibrator in a calibration hierarchy. However, not all calibrators in a calibration hierarchy are required to be commutable; different calibration hierarchies have different requirements for which calibrators must be commutable with CSs. Because assessment of commutability is a substantial effort, it is therefore important to determine which calibrators need to be commutable when implementing a calibration hierarchy. We provide guidance on which calibrators must be commutable with CSs, when a correction for any noncommutability bias is appropriate, and when commutability of a calibrator with CSs is not required for various types of calibration hierarchies described in ISO 17511:2020.


Subject(s)
Calibration , Humans , Reference Standards