Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 219
Filter
1.
Rev Sci Instrum ; 95(10)2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39360876

ABSTRACT

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1-20 MeV energy range, with a particular focus on the low-energy (1-6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

2.
Rev Sci Instrum ; 95(10)2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39356191

ABSTRACT

This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.

3.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39315911

ABSTRACT

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

4.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39315912

ABSTRACT

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

5.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39302171

ABSTRACT

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

6.
Rev Sci Instrum ; 95(6)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38912911

ABSTRACT

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference's uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

7.
Phys Rev Lett ; 132(3): 035101, 2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38307081

ABSTRACT

Magnetic reconnection is a ubiquitous and fundamental process in plasmas by which magnetic fields change their topology and release magnetic energy. Despite decades of research, the physics governing the reconnection process in many parameter regimes remains controversial. Contemporary reconnection theories predict that long, narrow current sheets are susceptible to the tearing instability and split into isolated magnetic islands (or plasmoids), resulting in an enhanced reconnection rate. While several experimental observations of plasmoids in the regime of low-to-intermediate ß (where ß is the ratio of plasma thermal pressure to magnetic pressure) have been made, there is a relative lack of experimental evidence for plasmoids in the high-ß reconnection environments which are typical in many space and astrophysical contexts. Here, we report strong experimental evidence for plasmoid formation in laser-driven high-ß reconnection experiments.

8.
Rev Sci Instrum ; 93(11): 113534, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461490

ABSTRACT

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241Am and 226Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

9.
Rev Sci Instrum ; 93(8): 083513, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050054

ABSTRACT

Recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 × 1017, places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (Tion), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 × 1017, and yield and Tion up to 2 × 1018 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 × 1019 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10× but also improve signal-to-background by 5×.

10.
Rev Sci Instrum ; 93(8): 083511, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050092

ABSTRACT

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately-namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 1017. The PDDT will be used for optimal efficiency and resolution in phase 3.

11.
Phys Rev E ; 105(6): L063202, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35854613

ABSTRACT

In laser-produced high-energy-density plasmas, large-scale strong magnetic fields are spontaneously generated by the Biermann battery effects when temperature and density gradients are misaligned. Saturation of the magnetic field takes place when convection and dissipation balance field generation. While theoretical and numerical modeling provide useful insight into the saturation mechanisms, experimental demonstration remains elusive. In this letter, we report an experiment on the saturation dynamics and scaling of Biermann battery magnetic field in the regime where plasma convection dominates. With time-gated charged-particle radiography and time-resolved Thomson scattering, the field structure and evolution as well as corresponding plasma conditions are measured. In these conditions, the spatially resolved magnetic fields are reconstructed, leading to a picture of field saturation with a scaling of B∼1/L_{T} for a convectively dominated plasma, a regime where the temperature gradient scale (L_{T}) exceeds the ion skin depth.

12.
Rev Sci Instrum ; 92(8): 083506, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-34470381

ABSTRACT

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 106. Three different designs are provided optimized for the measurement of DD protons, T3He deuterons, and 3He3He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector's response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

13.
Rev Sci Instrum ; 92(4): 043551, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243410

ABSTRACT

Mono-energetic proton radiography is a vital diagnostic for numerous high-energy-density-physics, inertial-confinement-fusion, and laboratory-astrophysics experiments at OMEGA. With a large number of campaigns executing hundreds of shots, general trends in D3He backlighter performance are statistically observed. Each experimental configuration uses a different number of beams and drive symmetry, causing the backlighter to perform differently. Here, we analyze the impact of these variables on the overall performance of the D3He backlighter for proton-radiography studies. This study finds that increasing laser drive asymmetry can degrade the performance of the D3He backlighter. The results of this study can be used to help experimental designs that use proton radiography.

14.
Rev Sci Instrum ; 92(6): 063502, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34243553

ABSTRACT

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

15.
Rev Sci Instrum ; 92(1): 013504, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33514215

ABSTRACT

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV-2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter-energy relation can be fit with the existing models at angles up to 30°. The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

17.
Environ Sci Technol ; 50(22): 12232-12240, 2016 11 15.
Article in English | MEDLINE | ID: mdl-27758097

ABSTRACT

Uranium groundwater contamination due to U mining and processing affects numerous sites globally. Bioreduction of soluble, mobile U(VI) to U(IV)-bearing solids is potentially a very effective remediation strategy. Uranium isotopes (238U/235U) have been utilized to track the progress of microbial reduction, with laboratory and field studies finding a ∼1‰ isotopic fractionation, with the U(IV) product enriched in 238U. However, the isotopic fractionation produced by adsorption may complicate the use of 238U/235U to trace microbial reduction. A previous study found that adsorption of U(VI) onto Mn oxides produced a -0.2‰ fractionation with the adsorbed U(VI) depleted in 238U. In this study, adsorption to quartz, goethite, birnessite, illite, and aquifer sediments induced an average isotopic fractionation of -0.15‰ with the adsorbed U(VI) isotopically lighter than coexisting aqueous U(VI). In bicarbonate-bearing matrices, the fractionation depended little on the nature of the sorbent, with only birnessite producing an atypically large fractionation. In the case of solutions with ionic strengths much lower than those of typical groundwater, less isotopic fractionation was produced than U(VI) solutions with greater ionic strength. Studies using U isotope data to assess U(VI) reduction must consider adsorption as a lesser, but significant isotope fractionation process.


Subject(s)
Uranium , Water Pollutants, Radioactive , Adsorption , Geologic Sediments , Groundwater , Minerals
19.
J Anim Sci ; 94(4): 1738-54, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27136031

ABSTRACT

In 2 experiments, dark-cutting (DC) beef strip loins were used to test the effects of citric acid-enhancement pH on visual and instrumental color of fresh and cooked steaks. In Exp. 1 and 2, each DC (mean pH = 6.57 and 6.65, respectively) and normal-pH, low USDA Choice (CH; mean pH = 5.48 and 5.51, respectively) strip loin was cut into 2 equal-length sections, and DC sections were injected to 111% of raw section weight with pH 3.5 to 5.0 (Exp. 1) or pH 2.0 to 3.5 (Exp. 2) solutions made by mixing citric acid in either 0.05% orthophosphate (PO) solution or tap water (HO) base solutions (Exp. 1) and 0.5% PO or 0.5% tripolyphosphate solution base solutions (Exp. 2). After enhancement, sections were cut into steaks, which were assigned to either 5 d of simulated retail display or cooked to 71°C for cooked color measurement. Postenhancement pH of DC steaks enhanced with pH 3.5 to 5.0 solutions did not ( ≥ 0.180) differ from that of nonenhanced DC steaks (Exp. 1) but linearly decreased ( < 0.001) as solution pH decreased from 3.5 to 2.0 (Exp. 2). Even though fresh color scores were increased ( < 0.001) by citric acid enhancement over untreated DC steaks during the first 3 d of display, fresh steak color never ( < 0.001) approached that of nonenhanced CH steaks. When compared with nonenhanced DC steaks, enhancement with pH 3.5 to 5.0 solutions received lower cooked color scores, whereas enhancing DC sections with pH 2.5 solutions produced cooked color and degree-of-doneness scores similar ( ≥ 0.113) to those of nonenhanced CH steaks (Exp. 2). Results indicated that the pH of citric acid enhancement solutions, regardless of base solution, were insufficient to improve the fresh color of DC beef; however, enhancement with pH 2.5 citric acid solutions effectively eliminated the persistent red cooked color typically associated with DC beef comparable with that of normal-pH beef.


Subject(s)
Citric Acid , Cooking , Red Meat/standards , Animals , Cattle , Polyphosphates , Water
20.
Oncogene ; 35(33): 4414-21, 2016 08 18.
Article in English | MEDLINE | ID: mdl-26725325

ABSTRACT

The p53 tumor suppressor is a stress sensor, driving cell cycle arrest or apoptosis in response to DNA damage or oncogenic signals. p53 activation by oncogenic signals relies on the p19(Arf) tumor suppressor, while p53 activation downstream of acute DNA damage is reported to be p19(Arf)-independent. Accordingly, p19(Arf)-deficient mouse embryo fibroblasts (MEFs) arrest in response to acute DNA damage. However, p19(Arf) is required for replicative senescence, a condition associated with an activated DNA damage response, as p19(Arf)-/- MEFs do not senesce after serial passage. A possible explanation for these seemingly disparate roles for p19(Arf) is that acute and chronic DNA damage responses are mechanistically distinct. Replicative senescence may result from chronic, low-dose DNA damage responses in which p19(Arf) has a specific role. We therefore examined the role of p19(Arf) in cellular responses to chronic, low-dose DNA-damaging agent treatment by maintaining MEFs in low oxygen and administering 0.5 G y γ-irradiation daily or 150 µM hydroxyurea, a replication stress inducer. In contrast to their response to acute DNA damage, p19(Arf)-/- MEFs exposed to chronic DNA damage do not senesce, revealing a selective role for p19(Arf) in senescence upon low-level, chronic DNA damage. We show further that p53 pathway activation in p19(Arf)-/- MEFs exposed to chronic DNA damage is attenuated relative to wild-type MEFs, suggesting a role for p19(Arf) in fine-tuning p53 activity. However, combined Nutlin3a and chronic DNA-damaging agent treatment is insufficient to promote senescence in p19(Arf)-/- MEFs, suggesting that the role of p19(Arf) in the chronic DNA damage response may be partially p53-independent. These data suggest the importance of p19(Arf) for the cellular response to the low-level DNA damage incurred in culture or upon oncogene expression, providing new insight into how p19(Arf) serves as a tumor suppressor. Moreover, our study helps reconcile reports suggesting crucial roles for both p19(Arf) and DNA damage-signaling pathways in tumor suppression.


Subject(s)
Cyclin-Dependent Kinase Inhibitor p16/physiology , DNA Damage , Animals , Cell Cycle Checkpoints , Gamma Rays , Genes, Tumor Suppressor , Mice , Tumor Suppressor Protein p53/physiology
SELECTION OF CITATIONS
SEARCH DETAIL