Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Vasc Surg ; 60: 76-84.e1, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31220590

ABSTRACT

BACKGROUND: Treatment of common and internal iliac aneurysms is usually done by open surgery. A novel iliac branch endoprosthesis (IBE) is commercially available with encouraging initial results. Our objective is to compare perioperative outcomes of patients with iliac aneurysms treated by open surgery (OS) versus endovascular repair with IBE. METHODS: The study was a retrospective, single-center review of patients who were treated for aortoiliac or isolated common and/or internal iliac artery aneurysms from 2014 to 2017. Patients with connective tissue disorders, infected grafts, or thoracoabdominal aneurysms were excluded. Primary outcomes were perioperative mortality, length of hospital (LOS) and intensive care unit (ICU) stay, estimated blood loss, need for red blood cell transfusion (RBC), and perioperative reinterventions. RESULTS: Sixty-seven patients (96% male) were treated with OS (n = 25, mean age 68 ± 8 years) or IBE (n = 42, mean age 73 ± 8 years; P = 0.02) with 1 symptomatic patient in each group. Perioperative mortality occurred in 1 patient in the OS group (4%), with no mortality in the IBE group (P = 0.37) Total LOS and ICU stay was higher for OS compared to IBE (total stay 7.5 ± 3.4 vs. 1.7 ± 1.4 days for IBE, P < 0.0001 and ICU LOS 3.3 ± 2.1 vs. 0.1 ± 0.4 days, P < 0.0001). Estimated blood loss was higher for patients undergoing OS (4,732 ± 2,540 mL) compared to patients treated with IBE (263 ± 451 mL, P < 0.0001), resulting in higher RBC transfusion requirements (1.5 ± 2.4 vs. 0.2 ± 0.8 units, P = 0.001). Five patients in the OS group had early procedure-related reinterventions, while 2 patients in the IBE group required reintervention for access site complications (20% vs. 4.7%, P = 0.09). CONCLUSIONS: Endovascular repair of iliac aneurysms with IBE is feasible and is associated with lower blood loss, LOS and ICU stay, and had lower RBC transfusion requirements. Cost analysis and long-term follow-up will be needed to define the value of this modality for iliac artery aneurysm repair.


Subject(s)
Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Iliac Aneurysm/surgery , Stents , Aged , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/mortality , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
2.
J Vasc Surg ; 70(2): 497-508.e1, 2019 08.
Article in English | MEDLINE | ID: mdl-30583905

ABSTRACT

OBJECTIVE: Type IB endoleak after endovascular aneurysm repair may be treated by an iliac branch endoprosthesis (IBE) through brachial access for internal iliac artery (IIA) stenting. The aim of this study was to evaluate outcomes of the IBE using an "up-and-over" transfemoral technique in patients with prior aortic repair compared with the standard technique in patients with de novo iliac aneurysms. METHODS: We reviewed the clinical data of patients treated for aortoiliac aneurysms using Gore IBE (W. L. Gore & Associates, Flagstaff, Ariz) between 2014 and 2017. The up-and-over technique was indicated in patients with type IB endoleak or common iliac aneurysms after prior aortic repair with bifurcated endografts or surgical grafts. End points were technical success, mortality, major adverse events, IIA patency, freedom from IIA branch instability (composite end point of any IIA branch-related complication leading to aneurysm rupture, death, occlusion, component separation, or reintervention to maintain branch patency or to treat a branch-related separation or endoleak), and freedom from secondary interventions or new-onset buttock claudication. RESULTS: There were 53 patients (51 male; 74 ± 8 years old) treated by 62 IBEs (9 bilateral). Standard technique was used in 36 patients (43 IBEs) and up-and-over technique in 17 (19 IBEs). Three patients had contralateral IIA embolization. Total procedure time, contrast material volume, and radiation dose averaged 168 ± 98 minutes, 140 ± 50 mL, and 1096 ± 1009 mGy, with no difference between techniques. Technical success was achieved in 98% of patients. Eleven patients had extension of IIA bridging stent into the posterior branch (eight standard, three up-and-over). Four patients (8%) had major adverse events due to estimated blood loss >1000 mL in all patients. There was no 30-day mortality after a median follow-up of 7 months (interquartile range, 3-12 months). There were two IIA stent occlusions (all standard), three iliac-related type I endoleaks (one standard, two up-and-over), and four secondary interventions (three standard, one up-and-over). At 1 year, patients treated by standard or up-and-over technique had similar primary patency (94% ± 4% vs 100%; P = .38) and secondary patency (97% ± 3% vs 100%; P = .54) and freedom from IIA branch instability (90% ± 6% vs 93% ± 7%; P = .48), secondary intervention (84% ± 8% vs 90% ± 9%; P = .63), and new-onset buttock claudication (90% ± 6% vs 100%; P = .35). CONCLUSIONS: Endovascular repair using IBE was associated with high technical success, no mortality, and low rate of complications using either the standard technique for de novo aneurysms or an up-and-over technique for patients with failed bifurcated endografts or grafts. The up-and-over technique should be considered a suitable alternative to brachial access in patients who require distal extension using IBEs.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Iliac Aneurysm/surgery , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Female , Humans , Iliac Aneurysm/diagnostic imaging , Male , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Time Factors , Treatment Outcome
3.
J Vasc Surg ; 70(1): 53-59, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30591296

ABSTRACT

OBJECTIVE: To describe index visits for acute aortic dissection (AD) to an academic center and validate the prevailing claims-based methodology to identify and stratify them. METHODS: Inpatient hospitalizations at a single center assigned an International Classification of Diseases, Ninth Revision (ICD-9) diagnosis code for AD from January 2005 to September 2015 were identified. Diagnoses were verified by review of medical records and imaging studies. All visits were secondarily stratified with the algorithm based on ICD-9 codes. Sensitivity and specificity analyses were conducted to evaluate the ability of the algorithm to correctly identify acute AD by Stanford class and treatment modality (type A open repair [TAOR], type B open repair [TBOR], thoracic endovascular repair [TEVAR], medical management [MM]). RESULTS: In the study interval, there were 1245 visits coded for AD attributed to 968 unique patients. Chart review verification demonstrated that the majority of visits were for AD (79%; n = 981), of which 32% (n = 310) were for an index acute AD event. The true distribution of acute AD visit classifications was TAOR (46.1%; n = 143), TBOR (5.2%; n = 16), TEVAR (7.7%; n = 24), and MM (39.4%; n = 122). The algorithm, which used ICD-9 codes, identified 631 acute visits and stratified them as TAOR (27.1%; n = 171), TBOR (4.1%; n = 26), TEVAR (4.9%; n = 31), and MM (63.9%; n = 403). Analyses demonstrated high specificities, but generally low sensitivities of the algorithm (TAOR: sensitivity, 58%, specificity, 92%; TBOR: sensitivity, 13%, specificity, 98%; TEVAR: sensitivity, 17%, specificity, 98%; MM: sensitivity, 73%, specificity, 72%). CONCLUSIONS: The prevalent claims-based strategy to identify hospitalizations with acute AD is specific, but lacks sensitivity. Caution should be exercised when studying AD with ICD-9 codes and improvements to existing claims-based methodologies are necessary to support future study of acute AD.


Subject(s)
Administrative Claims, Healthcare , Algorithms , Aortic Aneurysm, Abdominal/therapy , Aortic Aneurysm, Thoracic/therapy , Aortic Dissection/therapy , Blood Vessel Prosthesis Implantation , Cardiovascular Agents/therapeutic use , Data Mining/methods , Endovascular Procedures , International Classification of Diseases , Patient Admission , Aged , Aortic Dissection/classification , Aortic Dissection/diagnosis , Aortic Aneurysm, Abdominal/classification , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Thoracic/classification , Aortic Aneurysm, Thoracic/diagnosis , Blood Vessel Prosthesis Implantation/classification , Cardiovascular Agents/classification , Databases, Factual , Endovascular Procedures/classification , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies
4.
J Vasc Surg ; 68(4): 1071-1078, 2018 10.
Article in English | MEDLINE | ID: mdl-29685508

ABSTRACT

OBJECTIVE: The objective of the study was to report the feasibility and results of superior mesenteric artery (SMA) stenting using embolic protection devices (EPDs) to treat acute mesenteric ischemia (AMI) and chronic mesenteric ischemia (CMI). METHODS: A retrospective review was conducted of consecutive patients who underwent SMA stenting with EPDs from 2007 to 2016. EPDs were used selectively in patients with occlusions, severe calcification, or acute thrombus. A two-wire technique with SpiderFX 0.014-inch filter wire (Medtronic, Minneapolis, Minn) combined with a 0.018-inch wire was used to provide support and to facilitate stenting and EPD retrieval. Presence of macroscopic debris in the EPD was recorded and graded as minor (minimal debris) or major (large thrombus or plaque). End points were technical success, presence of EPD debris, embolization, early morbidity, and mortality. RESULTS: SMA stenting was performed in 179 patients, of whom 65 (36%) had EPDs. The mean age was 73 ± 11 years, and 49 were female (75%). Clinical presentation was CMI in 48 patients (74%) and AMI or acute-on-CMI in 17 (26%). Indications for EPD were severe calcification in 22 patients (34%), acute thrombus in 18 (28%), and total occlusion in 16 (25%). Bare-metal stents were used in 33 patients, covered stents in 26, and both types in 6. Adjunctive therapy included thrombolysis in seven patients, thrombectomy in four, and atherectomy in three. Technical success was 100%. There were no instances of filter retention or arterial trauma due to filter manipulation. Distal embolization was noted in four patients (6%), of whom two had AMI. All large emboli were retrieved using catheter aspiration devices, but one small distal embolus was left untreated with no clinical consequences. Two patients had vessel spasm treated by nitroglycerin. Macroscopic debris was noted in 43 patients (66%) and was major in 21 (49%) or minor in 22 (51%). Of the patients with AMI, five (29%) required exploratory laparotomy and four (23%) had bowel resection. Eight additional patients (12%) had early complications (five CMI, three AMI), including cardiac complications, brachial hematoma, acute cholecystitis, and acute respiratory distress syndrome in two patients each. There were no deaths among CMI patients and two early deaths (12%) among those who had AMI. CONCLUSIONS: Use of EPDs during SMA stenting is safe and feasible with a two-wire technique. Large macroscopic debris was noted in one-third of the patients when the filter was applied selectively in patients with acute symptoms, occlusions, or severely calcified lesions. Despite the use of EPD, distal embolization occurred in 6% of patients and was successfully treated using catheter aspiration devices.


Subject(s)
Embolic Protection Devices , Endovascular Procedures/instrumentation , Mesenteric Artery, Superior , Mesenteric Ischemia/therapy , Mesenteric Vascular Occlusion/therapy , Stents , Aged , Aged, 80 and over , Chronic Disease , Computed Tomography Angiography , Embolism/etiology , Embolism/prevention & control , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Feasibility Studies , Female , Humans , Male , Mesenteric Artery, Superior/diagnostic imaging , Mesenteric Artery, Superior/physiopathology , Mesenteric Ischemia/diagnostic imaging , Mesenteric Ischemia/mortality , Mesenteric Ischemia/physiopathology , Mesenteric Vascular Occlusion/diagnostic imaging , Mesenteric Vascular Occlusion/mortality , Mesenteric Vascular Occlusion/physiopathology , Middle Aged , Retrospective Studies , Risk Factors , Splanchnic Circulation , Time Factors , Treatment Outcome
5.
Ann Vasc Surg ; 29(6): 1084-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26009475

ABSTRACT

BACKGROUND: Popliteal venous aneurysms (PVAs) are rare; however, they can lead to pulmonary emboli (PEs) and death. The purpose of this study was to review our institutional management of PVA. METHODS: All patients with PVA undergoing intervention in our institution were identified over a 15-year period (1998-2013). A retrospective review including clinical presentation, modality of diagnosis, surgical treatment, 30-day morbidity and mortality, and follow-up are reported. RESULTS: Five male and 3 female patients with PVA were identified. Mean age was 38.6 years (range, 14-65). Five patients presented with PE; 1 developed PE while on anticoagulation. Two presented with lower extremity pain. Two patients had PVA found incidentally. Diagnosis of PVA was made by duplex ultrasound (US) in 6 patients, physical examination confirmed with duplex US in 1 patient, and magnetic resonance imaging in 1 patient. Mean aneurysm size was 26 mm (range, 20-37). Four were saccular and 4 fusiform. Three PVAs contained thrombus, including 2 patients presenting with PE and 1 with calf pain. Five patients underwent aneurysmectomy with lateral venorrhaphy, and 3 patients had resection of the aneurysm with interposition vein graft. There were no operative or 30-day mortalities. Two patients with vein grafts had early postoperative complications; one developed a hematoma that required operative evacuation and one had thrombosis of the vein graft requiring thrombolysis. Mean follow-up was 26 months with 87.5% primary patency, 100% secondary patency, and no recurrences. CONCLUSIONS: PVAs are rare, but can lead to significant morbidity and death. Based on this small group, aneurysmectomy with lateral venorrhaphy appears to have fewer complications compared with those treated with vein grafts. Overall, operative repair of PVA is safe and recommended in select patients with PVA.


Subject(s)
Aneurysm/surgery , Popliteal Vein/surgery , Saphenous Vein/transplantation , Vascular Grafting , Adolescent , Adult , Aged , Aneurysm/diagnosis , Aneurysm/mortality , Aneurysm/physiopathology , Female , Humans , Male , Middle Aged , Physical Examination , Popliteal Vein/diagnostic imaging , Popliteal Vein/physiopathology , Postoperative Complications/surgery , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex , Vascular Grafting/adverse effects , Vascular Grafting/mortality , Vascular Patency , Young Adult
6.
Ann Vasc Surg ; 27(1): 23-8, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23084733

ABSTRACT

BACKGROUND: Mycotic thoracic aortic aneurysms (MTAAs) are a rare yet life-threatening disease. The current standard of care consists of surgical resection, in situ or extra-anatomic revascularization, and antibiotic therapy. Despite this treatment, mortality remains high (range, 5-40%). The endovascular repair of degenerative thoracic aortic aneurysms has been shown to be safe and effective, but its use in the treatment of MTAAs is still controversial. The purpose of this study is to review the use of endovascular repair for MTAAs. METHODS: A 10-year retrospective chart review was conducted of patients who underwent endovascular repair of MTAAs between March 2001 and March 2011. The surgical results of this single-institution review are reported. RESULTS: Seven patients underwent endovascular repair of MTAAs. One patient died 2 days postoperatively, which gave an in-hospital survival rate of 85.7%. The 1-year survival rate was 71.4%. The mean follow-up time was 25 months (range, 0-72 months), with a survival rate at that time of 57.1%. All patients were free of infection during their follow-up period. CONCLUSIONS: In this single-center case series, endovascular repair of MTAAs was associated with favorable perioperative and short-term mortality and morbidity.


Subject(s)
Aneurysm, Infected/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Adult , Aged , Aged, 80 and over , Aneurysm, Infected/diagnostic imaging , Aneurysm, Infected/microbiology , Aneurysm, Infected/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/microbiology , Aortic Aneurysm, Thoracic/mortality , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Hospital Mortality , Humans , Male , Middle Aged , Retrospective Studies , Rhode Island , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
7.
Perspect Vasc Surg Endovasc Ther ; 24(4): 198-201, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23820181

ABSTRACT

Inferior vena cava (IVC) filters are used to treat thromboembolic disease when there is a contraindication to anticoagulation or failure of therapeutic anticoagulation therapy. Although there are retrievable IVC filters available, permanent IVC filters remain the most commonly placed IVC filters worldwide. Permanent IVC filters have been associated with long-term complications such as IVC thrombosis and obstruction, migration, and erosion into surrounding structures. Such complications may require removal of permanent IVC filters, which has been previously described with open surgery involving venotomy of the IVC. We report a case of a Bard Simon Nitinol permanent IVC filter that was removed by using percutaneous endovascular techniques.


Subject(s)
Alloys , Arthroplasty/adverse effects , Device Removal/methods , Endovascular Procedures , Pulmonary Embolism/therapy , Vena Cava Filters , Venous Thrombosis/therapy , Adult , Anticoagulants/therapeutic use , Humans , Male , Phlebography/methods , Prosthesis Design , Pulmonary Embolism/diagnosis , Pulmonary Embolism/etiology , Tomography, X-Ray Computed , Treatment Outcome , Venous Thrombosis/diagnosis , Venous Thrombosis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...