Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
2.
Endosc Ultrasound ; 12(2): 251-258, 2023.
Article in English | MEDLINE | ID: mdl-37148137

ABSTRACT

Background and Objectives: EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability. Materials and Methods: The following six major FNA and FNB needles were evaluated: SonoTip® ProControl, EZ Shot 3 Plus, Expect™ Standard Handle, SonoTip® TopGain, Acquire™, and SharkCore™. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope. Results: The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore™ had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip® TopGain were all similar to that of Acquire™. Conclusion: SonoTip® TopGain had similar puncturability to Acquire™ in all tested situations. Regarding the puncturability, SharkCore™ is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.

3.
J Hepatobiliary Pancreat Sci ; 30(4): e20-e21, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36048175

ABSTRACT

This paper discusses a novel tube placement technique; the "spinning lasso method", in EUS-guided drainage for small pancreatic pseudocysts (PC) with video. In general, the placement of a drainage tube can be difficult in a small PC and the tube often deviates during attempted insertions into the cavity. The technique helps to mitigate this problem.


Subject(s)
Pancreatic Pseudocyst , Humans , Pancreatic Pseudocyst/diagnostic imaging , Pancreatic Pseudocyst/surgery , Endosonography/methods , Drainage/methods , Stents
4.
J Hepatobiliary Pancreat Sci ; 29(6): e57-e58, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35302713

ABSTRACT

Highlight Interventional endoscopic ultrasound has become widely used although it remains challenging. Nagai and colleagues present the first case of single-session endoscopic ultrasound-guided hepaticogastrostomy and endoscopic ultrasound-guided pancreatic duct drainage, and demonstrate that it is feasible for the management of biliary and pancreatic duct stones in patients with surgically altered anatomy.


Subject(s)
Pancreatic Diseases , Stents , Drainage , Endosonography , Humans , Pancreatic Diseases/complications , Pancreatic Diseases/diagnostic imaging , Pancreatic Diseases/surgery , Pancreatic Ducts/diagnostic imaging , Pancreatic Ducts/surgery , Ultrasonography, Interventional
5.
J Hepatobiliary Pancreat Sci ; 29(7): 817-824, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35030302

ABSTRACT

BACKGROUND/PURPOSE: Although the lumen-apposing metal stent (LAMS) is useful for interventional endoscopic ultrasound (EUS) procedures, there has been some concern about the potential for stent-induced adverse events because of the high lumen-apposing force. A newly designed LAMS with less lumen-apposing force has been developed for use with a physician-controlled electrocautery-enhanced delivery system. The aim of this animal study was to evaluate the feasibility of performing interventional EUS using this newly designed LAMS system. METHODS: Endoscopic ultrasound-guided cystogastrostomy was performed using the novel LAMS three times in a wet simulation model. EUS-guided gastroenterostomy and EUS-guided gallbladder drainage were then performed using the system in four pigs. RESULTS: The LAMS was successfully placed in all three EUS-guided cystogastrostomy procedures using the wet simulation model and in all four EUS-guided gastroenterostomy and gallbladder drainage procedures in the animal model. In the 3 weeks following the procedure, eating behavior was normal in all animals and there were no adverse events. The stents remained patent during this time and were removed without difficulty. The fistula was mature in all cases and a standard upper gastrointestinal endoscope was easily advanced via the fistula to observe the afferent and efferent loops or the lumen of the gallbladder. Necropsy confirmed complete adhesion between the stomach and the wall of the jejunum or gallbladder. CONCLUSIONS: Our study findings demonstrate the feasibility of this new LAMS system and its potential clinical value for interventional EUS.


Subject(s)
Anastomosis, Surgical , Electrocoagulation , Endosonography , Prosthesis Implantation , Stents , Ultrasonography, Interventional , Anastomosis, Surgical/instrumentation , Anastomosis, Surgical/methods , Animals , Digestive System Fistula/etiology , Digestive System Fistula/surgery , Drainage/instrumentation , Drainage/methods , Electrocoagulation/instrumentation , Electrocoagulation/methods , Endosonography/instrumentation , Endosonography/methods , Gallbladder/surgery , Jejunum/surgery , Models, Animal , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Stomach/surgery , Swine , Ultrasonography, Interventional/instrumentation , Ultrasonography, Interventional/methods
6.
Endosc Ultrasound ; 10(4): 294-304, 2021.
Article in English | MEDLINE | ID: mdl-34259218

ABSTRACT

BACKGROUND AND OBJECTIVES: EUS-guided biliary drainage (EUS-BD) has recently been used for the treatment of not only malignant pancreaticobiliary diseases, but also for benign diseases. In most previous studies, EUS-BD was performed using a fully covered self-expandable metallic stent (SEMS), and data focusing on the usability of plastic stents for benign diseases are limited. We previously developed a plastic stent dedicated to EUS-guided hepaticoenterostomy (EUS-HES), and achieved favorable results in a feasibility study, although most of the patients had malignant diseases. Therefore, the aim of the present study was to evaluate the usability of dedicated plastic stents for EUS-HES in patients with benign pancreaticobiliary diseases. PATIENTS AND METHODS: A total of 57 consecutive patients (28 men, median age: 68 years; range: 7-90 years) of normal and surgically altered anatomy with benign pancreaticobiliary diseases who underwent EUS-HES using the dedicated plastic stent between Jan. 2015 and Jun. 2020 were retrospectively analyzed. Results: The overall technical success rate of EUS-HES was 92.9% (53/57). Among the 4 cases of technical failure of plastic stent placement, a SEMS was placed in 1; percutaneous transhepatic biliary drainage was performed in 1; EUS-HES was reperformed 1 week later in 1; and observational management was selected in 1 patient. Adverse events associated with the procedure were seen in 15.7% (9/57) of the patients, namely, biliary peritonitis in 4, bleeding in 2, cholecystitis in 2, and pneumoperitoneum in 1 patient. Except for 1 patient who required blood transfusion owing to bleeding and 1 patient with cholecystitis who required percutaneous transhepatic gallbladder drainage, the other 7 patients were treated by conservative therapy. There were no intervention-associated deaths. CONCLUSION: Our results demonstrated that for patients with benign pancreaticobiliary diseases in whom conventional ERCP was unsuccessful, EUS-HES using a dedicated plastic stent was safe and feasible.

7.
Sci Rep ; 11(1): 600, 2021 01 12.
Article in English | MEDLINE | ID: mdl-33436750

ABSTRACT

This study aimed to determine the clinicopathological features of the subtypes of ampullary carcinoma (AC) to explore the indications for endoscopic papillectomy (EP) in early AC. Fifty-seven patients with AC who underwent curative resection were retrospectively reviewed. The 0/IA stages were significantly more common in the intestinal type (I-type) than in the mixed and pancreatobiliary type (M&PB-type) (90.7% vs 35.7%, P < 0.001). Tis/T1a tumors limited to the ampulla [Tis/T1a(ampulla)] were significantly more likely to be I-type than M&PB-type (74.4% vs 14.3%, P = 0.002). The tub1 rate was significantly higher in the I-type than in the M&PB-type (81.4% vs 35.7%, P = 0.001). In the I-type, the tub1 rate was significantly higher for Tis/T1a(ampulla) than for T1a tumors limited to the sphincter of Oddi (100% vs 42.9%, P = 0.004). These observations suggest that I-type AC with tub1 is an indication for EP. The concordance rate of pathological subtypes between endoscopic biopsy and resected specimens was high (κ = 0.8053, P < 0.001). Tis/T1a(ampulla) showed no lymphovascular or perineural invasion. An endoscopic imaging finding of early AC with I-type and tub1 on biopsy could be an indication for EP. Identifying the pathological subtype of AC by endoscopic biopsy could be a novel preoperative approach for evaluating the indications for EP.


Subject(s)
Adenocarcinoma/pathology , Ampulla of Vater/pathology , Common Bile Duct Neoplasms/pathology , Sphincterotomy, Endoscopic/methods , Adenocarcinoma/classification , Adenocarcinoma/surgery , Adult , Aged , Aged, 80 and over , Ampulla of Vater/surgery , Common Bile Duct Neoplasms/classification , Common Bile Duct Neoplasms/surgery , Female , Humans , Male , Middle Aged , Prognosis , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL