Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
2.
Klin Monbl Augenheilkd ; 240(2): 158-162, 2023 Feb.
Article in English, German | MEDLINE | ID: mdl-36634688

ABSTRACT

BACKGROUND: In recent years, an increasing number of surgical microscopes fitted with an OCT module (intraoperative OCT, iOCT) have become available, providing high-resolution images of the surgical site in real time. While a 2018 survey at our hospital showed that iOCT delivered an additional intraoperative benefit in only 2.4% of all operations, considering that the manufacturer had since revised the hardware and software, we conducted a second user evaluation of this technology. MATERIAL AND METHODS: Prospective monocentric analysis of the application and user-friendliness of an EnFocus Ultra-Deep OCT (Leica Microsystems) over a period of 25 (2018) and 20 working days (2021). A standardized questionnaire was used to assess the surgeons' use of iOCT and its influence on the surgical course. RESULTS: 118 operations were performed over a 25-day period in 2018 and 92 operations were performed over a 20-day period in 2021. In 2018, iOCT was used in 24.6% and in 2021 in 48.9% of all surgeries, with iOCT proving to be "critical" to the surgical course in 2.4% and 3.3% of cases, respectively, as assessed by the surgeons in both years. These were operations in which the intraocular view was limited, e.g., with decompensated cornea, vitreous hemorrhage, or after previous surgery, e.g., after penetrating keratoplasty. CONCLUSION: Further development of the user interface led to an improvement in usability, and the iOCT was used significantly more often. In both years, the iOCT proved to be critical for the course of the surgery in a comparably small number of operations, especially those involving complex situations.


Subject(s)
Cornea , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Prospective Studies , Keratoplasty, Penetrating , Microscopy
3.
Semin Cell Dev Biol ; 137: 74-86, 2023 03 15.
Article in English | MEDLINE | ID: mdl-35144861

ABSTRACT

The organ of Corti, located in the cochlea within the inner ear is the receptor organ for hearing. It converts auditory signals into neuronal action potentials that are transmitted to the brain for further processing. The mature organ of Corti consists of a variety of highly differentiated sensory cells that fulfil unique tasks in the processing of auditory signals. The actin and microtubule cytoskeleton play essential function in hearing, however so far, more attention has been paid to the role of actin. Microtubules play important roles in maintaining cellular structure and intracellular transport in virtually all eukaryotic cells. Their functions are controlled by interactions with a large variety of microtubule-associated proteins (MAPs) and molecular motors. Current advances show that tubulin posttranslational modifications, as well as tubulin isotypes could play key roles in modulating microtubule properties and functions in cells. These mechanisms could have various effects on the stability and functions of microtubules in the highly specialised cells of the cochlea. Here, we review the current understanding of the role of microtubule-regulating mechanisms in the function of the cochlea and their implications for hearing, which highlights the importance of microtubules in the field of hearing research.


Subject(s)
Actins , Tubulin , Tubulin/metabolism , Actins/metabolism , Microtubules/metabolism , Microtubule-Associated Proteins , Protein Processing, Post-Translational , Hearing
4.
Klin Monbl Augenheilkd ; 240(9): 1077-1083, 2023 Sep.
Article in English, German | MEDLINE | ID: mdl-35609814

ABSTRACT

BACKGROUND: Ocular involvement in mucous membrane pemphigoid (MMP) is relatively rare, with a prevalence of 25 cases per million population, equating to approx. 2,100 patients throughout Germany. Diagnosis can be difficult - especially in cases of isolated ocular involvement - and treatment can be complex and lengthy. Immunosuppressants or immunomodulatory drugs are often used. Due to the complexity of diagnosis and treatment, MMP patients are usually referred to specialized centers. The aim of this project was to evaluate the current care situation of patients with ocular MMP in Germany. METHODS: A paper-based survey was designed and sent to all university eye clinics and other specialized centers in Germany in April 2020. The survey asked about the existence of a specialized outpatient service, the total annual number of patients with MMP, the annual number of newly diagnosed patients, any interdisciplinary collaboration for diagnostic or therapeutic purposes, as well as the local and systemic therapy used. RESULTS: Of a total of 44 clinics, 28 (64%) responded, reporting a total average of 27 ± 42 (0 - 200) patients and 3.6 ± 2.2 (0 - 10) new cases per year. This corresponds to a total of 741 patients. Only nine (32%) of the responding clinics offer specialized MMP clinics. 93% of the centers collaborate with the local dermatology department. 79% perform serological and histological diagnostics in-house. About half of the centers (n = 16) apply a standardized treatment regime. Systemic glucocorticoids (66.7%) are most commonly used, followed by mycophenolate mofetil and dapsone (57.1%), rituximab (33.3%), azathioprine and cyclophosphamide (28.6%), as well as methotrexate (19.0%). The least frequently used treatment is intravenous immunoglobulin (14.3%). CONCLUSION: This survey of German ophthalmology departments obtained data from about one third of the estimated total cohort of all patients with MMP in Germany. These are presumed to be exclusively patients with at least one ocular involvement. The complex care of these patients is usually provided in collaboration with a dermatologist and with the use of systemic anti-inflammatory medication. Currently, an ophthalmological MMP register is being established to better record the epidemiology and care situation of this rare disease in Germany and to improve it in the long term.


Subject(s)
Pemphigoid, Benign Mucous Membrane , Pemphigoid, Bullous , Humans , Pemphigoid, Bullous/chemically induced , Pemphigoid, Bullous/drug therapy , Immunosuppressive Agents/therapeutic use , Pemphigoid, Benign Mucous Membrane/diagnosis , Pemphigoid, Benign Mucous Membrane/drug therapy , Pemphigoid, Benign Mucous Membrane/epidemiology , Azathioprine/therapeutic use , Mucous Membrane
5.
Klin Monbl Augenheilkd ; 238(6): 693-699, 2021 Jun.
Article in English, German | MEDLINE | ID: mdl-34015834

ABSTRACT

BACKGROUND: In recent years, great progress has been made in intraoperative imaging using optical coherence tomography (iOCT). There are now several commercially available iOCT systems that allow high-resolution imaging of all structures of the eye without interrupting surgery. This real-time visualisation can provide additional information to conventional surgical microscopy, but is relatively expensive. The aim of our study was to find out how often OCT integrated into the surgical microscope is used by trained surgeons, or to what extent they consider that iOCT is relevant for intraoperative procedures. PATIENTS AND METHODS: A prospective monocentric analysis was conducted of the field of application and user-friendliness of the EnFocus Ultra-Deep OCT (Leica Microsystems), a mobile device combination of surgical microscope and OCT. The use and benefit were investigated of iOCT, which was not mandatory. Standardised documentation and evaluation using a questionnaire was performed by the respective surgeon (n = 5) immediately after surgery. RESULTS: Over a period of 25 working days, 118 procedures were performed in the operating theatre equipped with the microscope-OCT combination. The iOCT was used in 24.6% of the 118 procedures performed. iOCT was regarded as crucial to the intraoperative procedure in 3 of the 29 patients. In one patient, it was possible to check graft orientation during a DMEK operation in a very opaque cornea and, in the second patient, to visualise the correct positioning of an iris diaphragm in the capsular bag. In the third patient, the risk of developing a pseudoforamen was assessed, and this led to the decision not to perform a full gliosis peel. CONCLUSION: Experienced surgeons in a university eye hospital with a full surgical spectrum considered that intraoperative OCT was decisive for the course of surgery in only a few selected surgical situations, e.g. in case of limited corneal transparency. The impact of the use of iOCT on post-operative outcome quality still needs to be evaluated by larger prospective studies. On the basis of this survey, the cost-benefit ratio is still unclear.


Subject(s)
Monitoring, Intraoperative , Tomography, Optical Coherence , Cornea , Humans , Microscopy , Prospective Studies
6.
Histochem Cell Biol ; 154(6): 671-681, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32712744

ABSTRACT

The five tubulin-binding cofactors (TBC) are involved in tubulin synthesis and the formation of microtubules. Their importance is highlighted by various diseases and syndromes caused by dysfunction or mutation of these proteins. Posttranslational modifications (PTMs) of tubulin promote different characteristics, including stability-creating subpopulations of tubulin. Cell- and time-specific distribution of PTMs has only been investigated in the organ of Corti in gerbils. The aim of the presented study was to investigate the cell type-specific and time-specific expression patterns of TBC proteins and PTMs for the first time in murine cochleae over several developmental stages. For this, murine cochleae were investigated at the postnatal (P) age P1, P7 and P14 by immunofluorescence analysis. The investigations revealed several profound interspecies differences in the distribution of PTMs between gerbil and mouse. Furthermore, this is the first study to describe the spatio-temporal distribution of TBCs in any tissue ever showing a volatile pattern of expression. The expression analysis of TBC proteins and PTMs of tubulin reveals that these proteins play a role in the physiological development of the cochlea and might be essential for hearing.


Subject(s)
Cochlea/metabolism , Molecular Chaperones/analysis , Tubulin/metabolism , Animals , Cochlea/cytology , Mice , Microtubules/chemistry , Microtubules/metabolism , Molecular Chaperones/metabolism , Protein Processing, Post-Translational , Tubulin/biosynthesis , Tubulin/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...