Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Food Chem X ; 22: 101345, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38623501

ABSTRACT

This study investigated the effect of plasma treatment on reused water and evaluated the interactions of the plasma-treated water (PTW) with plants or microbes to determine the optimal PTW for reuse. The repeated treatment gradually accumulated nitrate (NO3-) in the PTW and lowered its pH; afterward, it led to the sprouted soybeans accumulating other inorganic ions in the PTW. The biomass of soybean sprouts was enhanced by the accumulated NO3- but decreased due to the pH effect. Meanwhile, the acidic pH reduced the microbial counts, but they increased after sprinkling the PTW over the sprouts. The optimal PTW in our study, which had a gradual increase of NO3- (≤321.8 mg·L-1) with an acceptable pH (≥pH 3), significantly enhanced the biomass by 4.2% compared to the untreated control. Additionally, it increased the total content of amino acids and isoflavones by 9% and 18% in the growing part, respectively.

2.
Int Neurourol J ; 27(Suppl 1): S40-48, 2023 May.
Article in English | MEDLINE | ID: mdl-37280759

ABSTRACT

PURPOSE: This clinical study sought to evaluate the possible clinical effectiveness and practicality of URINO, an innovative, incisionless, and disposable intravaginal device, designed for patients suffering from stress urinary incontinence. METHODS: A prospective, multicenter, single-arm clinical trial was carried out, involving women diagnosed with stress urinary incontinence who used a self-inserted, disposable intravaginal pessary device. Comparisons were made between the results of the 20-minute pad-weight gain (PWG) test at baseline and visit 3, where the device was applied. After 1 week of device usage, compliance, satisfaction, the sensation of a foreign body, and adverse events were assessed. RESULTS: Out of 45 participants, 39 completed the trial and expressed satisfaction within the modified intention-to-treat group. The average 20-minute PWG of participants was 17.2±33.6 g at baseline and significantly dropped to 5.3±16.2 g at visit 3 with device application. A total of 87.2% of participants exhibited a reduction ratio of PWG by 50% or more, surpassing the clinical trial success benchmark of 76%. The mean compliance was recorded as 76.6%±26.6%, the average visual analogue scale score for patient satisfaction was 6.4±2.6, and the sensation of a foreign body, measured on a 5-point Likert scale, was 3.1±1.2 after 1 week of device use. No serious adverse events were reported; there was 1 instance of microscopic hematuria and 2 cases of pyuria, all of which recovered. CONCLUSION: The investigated device demonstrated significant clinical effectiveness and safety for patients with stress urinary incontinence. It was easy to use, showing favorable patient compliance. We propose that these disposable intravaginal pessaries could potentially be an alternative treatment for patients with stress urinary incontinence who are seeking nonsurgical options or are unable to undergo surgery. Trial Registration: The study was registered as a clinical trial (KCT0008369).

3.
Life (Basel) ; 12(1)2022 Jan 04.
Article in English | MEDLINE | ID: mdl-35054463

ABSTRACT

Severe acute respiratory syndrome coronavirus (SARS-CoV-2) is highly contagious and causes coronavirus disease 2019 (COVID-19). Reverse transcription quantitative polymerase chain reaction (RT-qPCR) is the most accurate and reliable molecular assay to detect active SARS-CoV-2 infection. However, a rapid increase in test subjects has created a global bottleneck in testing capacity. Given that efficient nucleic acid extraction greatly affects reliable and accurate testing results, we compared three extraction platforms: MagNA Pure 96 DNA and Viral NA Small Volume kit on MagNA Pure 96 (Roche, Basel, Switzerland), careGENETM Viral/Pathogen HiFi Nucleic Acid Isolation kit (WELLS BIO Inc., Seoul, Korea) on KingFisher Flex (Thermo Fisher Scientific, Rocklin, CA, USA), and SGRespiTM Pure kit (Seegene Inc., Seoul, Korea) on Maelstrom 9600 (Taiwan Advanced Nanotech Inc., Taoyuan, Taiwan). RNA was extracted from 245 residual respiratory specimens from the different types of samples (i.e., NPS, sputum, and saliva) using three different kits. The 95% limits of detection of median tissue culture infectious dose per milliliter (TCID50/mL) for the MagNA Pure 96, KingFisher Flex, and Maelstrom 9600 were 0.37-3.15 × 101, 0.41-3.62 × 101, and 0.33-1.98 × 101, respectively. The KingFisher Flex platform exhibited 99.2% sensitivity and 100% specificity, whereas Maelstrom 9600 exhibited 98.3-100% sensitivity and 100% specificity. Bland-Altman analysis revealed a 95.2% concordance between MagNA Pure 96 and KingFisher Flex and 95.4% concordance between MagNA Pure 96 and Maelstrom 9600, indicating that all three platforms provided statistically reliable results. This suggests that two modifying platforms, KingFisher Flex and Maelstrom 9600, are accurate and scalable extraction platforms for large-scale SARS-CoV-2 clinical detection and could help the management of COVID-19 patients.

4.
Diagnostics (Basel) ; 11(6)2021 Jun 13.
Article in English | MEDLINE | ID: mdl-34199257

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) triggers disease with nonspecific symptoms that overlap those of infections caused by other seasonal respiratory viruses (RVs), such as the influenza virus (Flu) or respiratory syncytial virus (RSV). A molecular assay for accurate and rapid detection of RV and SARS-CoV-2 is crucial to manage these infections. Here, we compared the analytical performance and clinical reliability of Allplex™ SARS-CoV-2/FluA/FluB/RSV (SC2FabR; Seegene Inc., Seoul, South Korea) kit with those of four commercially available RV detection kits. Upon testing five target viral strains (SARS-CoV-2, FluA, FluB, RSV A, and RSV B), the analytical performance of SC2FabR was similar to that of the other kits, with no significant difference (p ≥ 0.78) in z-scores. The efficiency of SC2FabR (E-value, 81-104%) enabled reliable SARS-CoV-2 and seasonal RV detection in 888 nasopharyngeal swab specimens processed using a fully automated nucleic acid extraction platform. Bland-Altman analyses revealed an agreement value of 95.4% (SD ± 1.96) for the kits, indicating statistically similar results for all five. In conclusion, SC2FabR is a rapid and accurate diagnostic tool for both SARS-CoV-2 and seasonal RV detection, allowing for high-throughput RV analysis with efficiency comparable to that of commercially available kits. This can be used to help manage respiratory infections in patients during and after the coronavirus disease 2019 pandemic.

5.
PLoS One ; 16(6): e0253402, 2021.
Article in English | MEDLINE | ID: mdl-34138947

ABSTRACT

Classification of clinical symptoms and diagnostic microbiology are essential to effectively employ antimicrobial therapy for lower respiratory tract infections (LRTIs) in a timely manner. Empirical antibiotic treatment without microbial identification hinders the selective use of narrow-spectrum antibiotics and effective patient treatment. Thus, the development of rapid and accurate diagnostic procedures that can be readily adopted by the clinic is necessary to minimize non-essential or excessive use of antibiotics and accelerate patient recovery from LRTI-induced damage. We developed and validated a multiplex real-time polymerase chain reaction (mRT-PCR) assay with good analytical performance and high specificity to simultaneously detect four bacterial pathogens causing pneumonia: Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, and Moraxella catarrhalis. The analytical performance of mRT-PCR against target pathogens was evaluated by the limit of detection (LOD), specificity, and repeatability. Two hundred and ten clinical specimens from pneumonia patients were processed using an automatic nucleic acid extraction system for the "respiratory bacteria four" (RB4) mRT-PCR assay, and the results were directly compared to references from bacterial culture and/or Sanger sequencing. The RB4 mRT-PCR assay detected all target pathogens from sputum specimens with a coefficient of variation ranging from 0.29 to 1.71 and conservative LOD of DNA corresponding to 5 × 102 copies/reaction. The concordance of the assay with reference-positive specimens was 100%, and additional bacterial infections were detected from reference-negative specimens. Overall, the RB4 mRT-PCR assay showed a more rapid turnaround time and higher performance that those of reference assays. The RB4 mRT-PCR assay is a high-throughput and reliable tool that assists decision-making assessment and outperforms other standard methods. This tool supports patient management by considerably reducing the inappropriate use of antibiotics.


Subject(s)
Klebsiella pneumoniae/isolation & purification , Moraxella catarrhalis/isolation & purification , Pneumonia/diagnosis , Pseudomonas aeruginosa/isolation & purification , Staphylococcus aureus/isolation & purification , Humans , Multiplex Polymerase Chain Reaction/methods , Pneumonia/microbiology , Sensitivity and Specificity
6.
Can J Infect Dis Med Microbiol ; 2021: 6651045, 2021.
Article in English | MEDLINE | ID: mdl-34055116

ABSTRACT

The detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in upper and lower respiratory specimens and coinfection with other respiratory pathogens in patients with coronavirus disease 2019 (COVID-19) was investigated. Study subjects (N = 342) were retrospectively enrolled after being confirmed as SARS-CoV-2 positive, and their nasopharyngeal swab (NPS), oropharyngeal swab (OPS), and sputum specimens were restored for SARS-CoV-2 retesting and respiratory pathogen detection. The majority of the subjects (96.5%, N = 330) were confirmed as SARS-CoV-2 positive using NPS/OPS specimens. Among the COVID-19 patients (N = 342), 7.9% (N = 27) and 0.9% (N = 3) were coinfected with respiratory viruses and Mycoplasma pneumoniae, respectively, yielding an 8.8% (N = 30) overall respiratory pathogen coinfection rate. Of the respiratory virus coinfection cases (N = 27), 92.6% (N = 25) were coinfected with a single respiratory virus and 7.4% (N = 2) with two viruses (metapneumovirus/adenovirus and rhinovirus/bocavirus). No triple coinfections of other respiratory viruses or bacteria with SARS-CoV-2 were detected. Respiratory viruses coinfected in the patients with COVID-19 were as follows: rhinovirus (N = 7, 2.1%), respiratory syncytial virus A and B (N = 6, 1.8%), non-SARS-CoV-2 coronaviruses (229E, NL63, and OC43, N = 5, 1.5%), metapneumovirus (N = 4, 1.2%), influenza A (N = 3, 0.9%), adenovirus (N = 3, 0.9%), and bocavirus (N = 1, 0.3%). In conclusion, the diagnostic value of utilizing NPS/OPS specimens is excellent, and, as the first report in Korea, coinfection with respiratory pathogens was detected at a rate of 8.8% in patients with COVID-19.

7.
Sci Rep ; 11(1): 2924, 2021 02 03.
Article in English | MEDLINE | ID: mdl-33536557

ABSTRACT

Ginseng (Panax ginseng Meyer) sprouts are grown to whole plants in 20 to 25 days in a soil-less cultivation system and then used as a medicinal vegetable. As a nitrogen (N) source, plasma-treated water (PTW) has been used to enhance the seed germination and seedling growth of many crops but has not been investigated for its effects on ginseng sprouts. This study established an in-situ system for N-containing water production using plasma technology and evaluated the effects of the PTW on ginseng growth and its bioactive phytochemicals compared with those of an untreated control. The PTW became weakly acidic 30 min after the air discharge at the electrodes because of the formation of nitrate (NO3‒) and nitrite (NO2‒) in the water. The NO3‒ and NO2‒ in the PTW, together with potassium ions (K+), enhanced the shoot biomass of the ginseng sprout by 26.5% compared to the untreated control. The ginseng sprout grown in the PTW had accumulated more free amino acids and ginsenosides in the sprout at 25 days after planting. Therefore, PTW can be used as a liquid N fertilizer for P. ginseng growth and phytochemical accumulation during sprouting under aeroponic conditions.


Subject(s)
Ginsenosides/analysis , Panax/chemistry , Seedlings/growth & development , Water/chemistry , Agriculture/methods , Nitrogen/chemistry , Nitrogen/metabolism , Panax/growth & development , Panax/metabolism , Plasma Gases , Seedlings/chemistry , Seedlings/metabolism
8.
Int J Infect Dis ; 99: 279-285, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32763446

ABSTRACT

OBJECTIVES: The aim of this study was to elucidate patterns of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) clearance in the natural course of asymptomatic coronavirus disease 2019 (COVID-19). METHODS: Consecutive patients with non-severe COVID-19 were included retrospectively. Asymptomatic patients with a normal body temperature and no evidence of pneumonia throughout the disease course were assigned to the asymptomatic group. The reverse transcription PCR (RT-PCR) assay was repeated every two to five days after the first follow-up RT-PCR assay. Negative conversion was defined as two consecutive negative RT-PCR assay results within a 24-h interval. Rebound of the cycle threshold (Ct) value was defined as negative from the single RT-PCR assay and positive from the following assay. RESULTS: Among a total of 396 patients identified (median age 42.5 years (interquartile range (IQR) 25.0-55.0 years), 35.6% male), 68 (17.2%) were assigned to the asymptomatic group and 328 (82.8%) to the symptomatic group. The time until negative conversion was significantly shorter in the asymptomatic group than in the symptomatic group: median 14.5 days (IQR 11.0-21.0 days) and 18.0 days (IQR 15.0-22.0 days), respectively (p = 0.001). Rebound of Ct values was observed in 78 patients (19.7%). CONCLUSIONS: Time until negative conversion is shorter in asymptomatic COVID-19 than in symptomatic COVID-19. Rebound of Ct values is not uncommon.


Subject(s)
Betacoronavirus/genetics , Coronavirus Infections/epidemiology , Pandemics , Pneumonia, Viral/epidemiology , Adult , Asymptomatic Diseases , COVID-19 , Cohort Studies , Coronavirus Infections/diagnosis , Coronavirus Infections/virology , Disease Progression , Female , Humans , Male , Middle Aged , Pneumonia, Viral/diagnosis , Pneumonia, Viral/virology , Republic of Korea/epidemiology , Retrospective Studies , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Viral Load
9.
Arch Pathol Lab Med ; 140(3): 276-80, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26927723

ABSTRACT

CONTEXT: The Anyplex II HPV HR detection kit (Seegene Inc, Seoul, Korea) is a new, multiplex, real-time polymerase chain reaction assay to detect individual 14 high-risk (HR) human papillomavirus (HPV) types in a single tube. OBJECTIVE: To evaluate the clinical performance of the HPV HR kit in predicting high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse in cervical cancer screening. DESIGN: We analyzed 1137 cervical samples in Huro Path medium (CelltraZone, Seoul, Korea) from Korean women. The clinical performance of the HPV HR kit was compared with Hybrid Capture 2 (Qiagen, Valencia, California) using the noninferiority score test in a routine cervical cancer screening setting. The intralaboratory and interlaboratory agreements of HPV HR were also evaluated. RESULTS: Overall agreement between the 2 assays was 92.4% (1051 of 1137) with a κ value of 0.787. Clinical sensitivity of HPV HR for high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse was 94.4% (95% confidence interval [CI], 89.2-99.7) and 92.5% (95% CI, 84.3-100.0), respectively. The respective values for Hybrid Capture 2 were 93.1% (95% CI, 87.2-98.9) and 87.5% (95% CI, 77.3-99.7). Clinical sensitivity and specificity of HPV HR were not inferior to those of Hybrid Capture 2 (P = .005 and P = .04, respectively). The HPV HR showed good intralaboratory and interlaboratory reproducibility at 98.0% (κ = 0.953) and 97.4% (κ = 0.940), respectively. CONCLUSIONS: The HPV HR demonstrates comparable performance to the Hybrid Capture 2 test and can be useful for HPV-based cervical cancer screening testing.


Subject(s)
Alphapapillomavirus/isolation & purification , Cervix Uteri/virology , DNA, Viral/analysis , Early Detection of Cancer , Papillomavirus Infections/diagnosis , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Neoplasms/diagnosis , Adult , Alphapapillomavirus/classification , Atypical Squamous Cells of the Cervix/classification , Atypical Squamous Cells of the Cervix/pathology , Atypical Squamous Cells of the Cervix/virology , Cervix Uteri/pathology , Early Detection of Cancer/standards , Female , Human Papillomavirus DNA Tests , Humans , Multiplex Polymerase Chain Reaction , Neoplasm Grading , Papillomavirus Infections/epidemiology , Papillomavirus Infections/pathology , Papillomavirus Infections/virology , Practice Guidelines as Topic , Reagent Kits, Diagnostic , Real-Time Polymerase Chain Reaction , Republic of Korea/epidemiology , Risk Factors , Sensitivity and Specificity , Squamous Intraepithelial Lesions of the Cervix/diagnosis , Squamous Intraepithelial Lesions of the Cervix/epidemiology , Squamous Intraepithelial Lesions of the Cervix/pathology , Squamous Intraepithelial Lesions of the Cervix/virology , Uterine Cervical Neoplasms/epidemiology , Uterine Cervical Neoplasms/pathology , Uterine Cervical Neoplasms/virology , Uterine Cervical Dysplasia/epidemiology , Uterine Cervical Dysplasia/pathology , Uterine Cervical Dysplasia/virology
10.
J Clin Apher ; 26(3): 162-5, 2011.
Article in English | MEDLINE | ID: mdl-21322001

ABSTRACT

Atypical hemolytic uremic syndrome (aHUS) is a rare form of complement dysregulation disease, and recently various reports have shown that it is associated with one or more mutations in the complement regulatory genes including complement factor H (CFH). Plasma exchange is a therapeutic option for adult patients, but not for a very young infant because of a potential side effect of therapeutic plasma exchange (TPE) itself. Herein, we describe a case of successful treatment of early onset aHUS associated with a novel CFH mutation with total 21 sessions of TPE over a period of 46 days in 3.2 kg 23-day-old neonate.


Subject(s)
Hemolytic-Uremic Syndrome/therapy , Plasma Exchange , Atypical Hemolytic Uremic Syndrome , Body Weight , Complement Factor H/genetics , Female , Humans , Infant, Newborn , Mutation , Treatment Outcome
11.
Ann Clin Lab Sci ; 40(2): 167-71, 2010.
Article in English | MEDLINE | ID: mdl-20421629

ABSTRACT

Amikacin (AN) is the most active aminoglycoside for the treatment of infections caused by Acinetobacter baumannii. The VITEK 2 automated system showed false susceptibility to AN for the A. baumannii isolate harboring armA. This phenomenon was not observed in the Serratia marcescens isolate harboring armA, but was detected in its transconjugant E. coli J53.


Subject(s)
Acinetobacter baumannii/drug effects , Acinetobacter baumannii/enzymology , Amikacin/pharmacology , Drug Resistance, Bacterial/drug effects , Genes, Bacterial/genetics , Microbial Sensitivity Tests/methods , Acinetobacter baumannii/genetics , Acinetobacter baumannii/isolation & purification , Carbonyl Cyanide m-Chlorophenyl Hydrazone/pharmacology , Disk Diffusion Antimicrobial Tests , Electrophoresis, Gel, Pulsed-Field
12.
Biol Pharm Bull ; 29(3): 547-9, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16508164

ABSTRACT

Vesicular glutamate transporter (VGLUT) plays an essential role in L-glutamate signaling in neurons and some peripheral tissues through vesicular storage of L-glutamate in secretory vesicles. To investigate the topology of VGLUT in membranes, we prepared site-directed antibodies against the amino-terminal (anti-N), 1st putative loop (anti-L), and carboxyl terminal (anti-C) regions. None of the antibodies reacted with VGLUT2 expressed in COS cells because they could not gain access to the antigen. However, both the anti-N and anti-C antibodies recognized VGLUT2 when the cells were permeabilized with digitonin, while the anti-L antibodies did not. Immunological reactivity to anti-L-antibodies appeared when the cells were permeabilized with Triton X-100. These results suggest that both the amino-terminal and carboxyl-terminal regions of VGLUT2 in membranes face the cytoplasm while the 1st loop faces the lumen.


Subject(s)
Vesicular Glutamate Transport Protein 2/metabolism , Animals , Antibodies/chemistry , Antibodies/immunology , COS Cells , Chlorocebus aethiops , DNA/chemistry , DNA/immunology , Glutamic Acid/metabolism , Immunohistochemistry , Membranes/metabolism , Vesicular Glutamate Transport Protein 2/genetics
13.
J Neurochem ; 96(2): 550-60, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16336630

ABSTRACT

Vesicular glutamate transporter (VGLUT) is responsible for the vesicular storage of l-glutamate, and plays an essential role in glutamate-mediated intercellular signal transmission in the CNS and in some neuroendocrine cells. Intestinal L cells are the glucose-responsive neuroendocrine cells responsible for the secretion of glucagon-like peptide 1 (GLP-1). We have shown that intestinal L cells express VGLUT2, a VGLUT isoform, which suggests that L cells secrete L-glutamate. In the present study, we investigated this possibility using GLUTag mouse clonal L cells. RT-PCR and northern blot analyses revealed expression of the VGLUT1 and VGLUT2 genes, but not of the VGLUT3 gene. Western blot analysis revealed immunological counterparts for VGLUT2, whereas an immunological counterpart of VGLUT1 was not detected. Indirect immunofluorescence microscopy revealed a punctate distribution of VGLUT2 immunoreactivity throughout the cells, which co-localized with GLP-1. Double-labeling immunoelectronmicroscopy confirmed the association of VGLUT2 with GLP-1-containing secretory granules. The membrane fraction exhibited ATP-dependent L-glutamate uptake, which was sensitive to bafilomycin A1 (a vacuolar proton ATPase inhibitor) and Evans blue (a VGLUT inhibitor) but insensitive to D,L-aspartate. Upon depolarization with KCl, GLUTag cells secreted appreciable amounts of L-glutamate and GLP-1. D-Glucose and methyl-alpha-D-glucopyranoside, stimulators of exocytosis of GLP-1, also triggered the secretion of L-glutamate. The L-glutamate secretion was partially dependent on Ca2+ and sensitive to bafilomycin A1. These results demonstrated that GLUTag cells stored L-glutamate in secretory granules and secreted it with GLP-1 by exocytosis. As GLUTag cells and intestinal L cells express kainate receptors and plasma membrane glutamate transporters, these results support the concept of L-glutamate-mediated intercellular signaling in the vicinity of intestinal L cells.


Subject(s)
Glucagon-Like Peptide 1/metabolism , Glutamic Acid/metabolism , Intestine, Small/metabolism , Secretory Vesicles/metabolism , Animals , Clone Cells , Exocytosis , Glutamic Acid/pharmacokinetics , Intestine, Small/cytology , Mice , Signal Transduction , Vesicular Glutamate Transport Protein 2/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...