Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 92(3): 033511, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820108

ABSTRACT

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm-352 nm), stimulated Raman scattering (430 nm-760 nm), and ω/2 (695 nm-745 nm). SLTD measures scattered light with a time resolution of ∼1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

2.
Rev Sci Instrum ; 87(11): 11D504, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910626

ABSTRACT

A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu Kα1 line. To demonstrate the performance of the spectrometer under high-power conditions, Kα1,2 emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 1018 W/cm2. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

3.
Rev Sci Instrum ; 85(11): 11E501, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430343

ABSTRACT

A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si Heα line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 µm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.

4.
Rev Sci Instrum ; 83(10): 10E501, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23127008

ABSTRACT

Using a spherically bent quartz crystal for the Si He(α) line at ~1.865 keV, a narrowband x-ray imager has been deployed at the Omega Laser Facility to record backlit images of direct-drive laser implosions. The crystal was cut along the 1011 planes for a 2d spacing of 0.687 nm, resulting in a Bragg angle of 83.9°. Apertures in front of the crystal were used to control the astigmatism of the imaging system. The backlit images show a high signal-to-background ratio of >10:1 with backlighter laser energies ≥1.5 kJ at a 10-ps pulse duration and a spatial resolution of better than 20 µm.

5.
Phys Rev Lett ; 108(8): 085002, 2012 Feb 24.
Article in English | MEDLINE | ID: mdl-22463537

ABSTRACT

Time-resolved K(α) spectroscopy has been used to infer the hot-electron equilibration dynamics in high-intensity laser interactions with picosecond pulses and thin-foil solid targets. The measured K(α)-emission pulse width increases from ~3 to 6 ps for laser intensities from ~10(18) to 10(19) W/cm(2). Collisional energy-transfer model calculations suggest that hot electrons with mean energies from ~0.8 to 2 MeV are contained inside the target. The inferred mean hot-electron energies are broadly consistent with ponderomotive scaling over the relevant intensity range.

6.
Opt Lett ; 14(6): 323-5, 1989 Mar 15.
Article in English | MEDLINE | ID: mdl-19749908

ABSTRACT

We describe a phase-conjugate interferometer that consists of a partially transmitting conventional mirror placed in front of and in close proximity to a phase-conjugate mirror. The interferometer is self-referencing, compact, and insensitive to environmental disturbances, provides twice the sensitivity of conventional (nonphase-conjugate) interferometers, and produces a direct representation of an incident wave front. We have constructed such a device using internally self-pumped phase conjugation in barium titanate and have used the device to characterize the wave front produced by an aberrated optical system.

SELECTION OF CITATIONS
SEARCH DETAIL
...