Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 65
Filter
1.
Materials (Basel) ; 17(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38730851

ABSTRACT

AIM: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses. MATERIALS AND METHODS: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.5, 0.75, 1.0, 1.50 and 2.0 mm). All specimens were polished with a polishing system for lithium disilicate restorations following recommendations from the manufacturer. Light transmission was evaluated with a radiometer. The statistical analysis between e.max CAD and LiSi GC Block was performed using a Mann-Whitney test for each thickness at a significance level of 0.05 (p < 0.05), followed by a Kruskal-Wallis test to compare the light transmission between the thicknesses of e.max CAD and LiSi GC Block. RESULTS: Light transmittance was significantly affected by ceramic thickness. The 0.5 mm thick specimens exhibited the highest transmittance values compared to all other groups, while a light transmittance of 0.00 was observed in the 2.0 mm thick specimens for both e.max CAD and LiSi GC Block. In the comparison between e.max CAD and LiSi GC Block according to thickness, there was a statistically significant difference exclusively between groups with a thickness of 1.50 mm (p = 0.002). CONCLUSIONS: Light transmission for pre- and fully crystallized CAD/CAM lithium disilicate ceramics only showed a statistical difference at the thickness of 1.50 mm (p = 0.002). E.max CAD demonstrated acceptable light transmission up to a thickness of 1.5 mm. CLINICAL SIGNIFICANCE: A thickness of 2 mm for chairside CAD/CAM lithium disilicate ceramics, whether pre-crystallized or fully crystallized, necessitates the use of dual-cure resin luting cement due to reduced light transmission.

2.
J Prosthet Dent ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38729791

ABSTRACT

STATEMENT OF PROBLEM: Minimally invasive treatments have gained popularity in recent years. However, research comparing the fracture resistance of lithium disilicate partial coverage veneer restorations with that of ceramic crowns is lacking. PURPOSE: The purpose of this in vitro study was to evaluate and compare the fracture resistance of lithium disilicate restorations fabricated for preparations of various designs. The designs included veneer preparations with finish lines in the upper, middle, and lower third of the facial surface and ceramic crown preparations with margins in the lower third of the facial surface. All restorations were designed and fabricated using a chairside digital workflow. MATERIAL AND METHODS: Four maxillary right central incisor typodont teeth were prepared for partial coverage veneer preparation with the margin in the upper middle third of the facial surface (PU1/3); partial coverage veneer preparation with margin in lower middle third of the facial surface (PL1/3); complete coverage veneer preparation (CV) with margin in the cervical region; and ceramic crown (CC) preparation. Each preparation was scanned, and 15 casts were 3D printed from each scan. A total of 60 lithium disilicate restorations were fabricated (n=15 per group) using a chairside computer-aided design and computer-aided manufacturing (CAD-CAM) system (Primescan and MCXL). The different restorations were cemented to the 3D printed testing dies with a photopolymerizable resin cement. The specimens were artificially aged with 10 000 thermal cycles between 5 and 55 °C with a dwell time of 30 seconds and were loaded to failure using a universal testing machine. The maximum load to fracture was analyzed using a 1-way ANOVA and post hoc Tukey honestly significant difference (HSD) test (α=.05). Additionally, the fracture patterns of the specimens were evaluated with a stereomicroscope for descriptive purposes. RESULTS: The mean fracture resistance of the chairside CAD-CAM lithium disilicate veneers and ceramic crowns was statistically different depending on the design of the restoration (P<.05). Group CC demonstrated the highest fracture resistance values (1440.66 N), followed by CV (929.8 N) and PU1/3 (756.13 N). The lowest value was for PL1/3 (532.4 N). CONCLUSIONS: The fracture resistance measured for the maxillary central incisor partial coverage veneers with margins in the middle third of the facial surface appear capable of resisting average occlusal forces. However, these veneers demonstrated lower fracture resistance values when compared with complete coverage veneers. Further, lithium disilicate crowns demonstrated higher fracture resistance than veneers, irrespective of their design.

3.
J Prosthodont ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734932

ABSTRACT

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

4.
Dent Mater J ; 2024 May 01.
Article in English | MEDLINE | ID: mdl-38692907

ABSTRACT

To evaluate the degree of conversion (DC), surface hardness (SH), and flexural strength (FS) of resin-based core build-up materials. Core build-up materials used were: MultiCore Flow (MCF); Activa (ACT); Core-X Flow (CXF); and everX flow (EVX), and DC, SH and FS were measured. An increase of DC was identified for all materials post-cure, except for EVX. The DC change percentage ranged from 5%-33%, and EVX was displayed the greatest DC rate. All materials displayed an SH increase after 30 days and the greatest increase was observed in ACT. At 1 h, the SH of EVX and CXF was different from the other materials. At 30 days, MCF displayed the greatest SH. All materials displayed an increase in their FS after 30 days except for EVX, and ranging 3%-36% were noticed. Differences observed between materials, thus clinician should be acquainted mechanical properties of these materials to ensure the success of the restorations.

5.
J Prosthodont ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715352

ABSTRACT

PURPOSE: To evaluate the fracture load of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) veneers fabricated with two conventional pre-crystallized and two fully crystallized lithium disilicate ceramic materials. MATERIALS AND METHODS: Seventy-five chairside CAD-CAM veneers (15 specimens/group) for maxillary right central incisors were fabricated with different lithium disilicate brands: (1) IPS e.max CAD; (2) Amber Mill; (3) Cerec Tessera; (4) n!ce Straumann; and (5) GC Initial LiSi Block. Restorations were cemented with resin luting cement (Variolink Esthetic, Ivoclar) to 3D-printed resin dies. Bonded restorations received 5000 thermal cycles and then were loaded until fracture. Statistical analysis included One-Way ANOVA. RESULTS: Conventional pre-crystallized e.max CAD displayed the highest fracture load value (640 N), followed by fully-crystallized n!ce Straumann (547 N), pre-crystallized Cerec Tessera (503 N), pre-crystallized Amber Mill (476 N), respectively; fully-crystallized GC Initial LiSi Block (431 N) displayed the lowest values. When comparing the fracture load of recent lithium disilicate ceramic material to the e.max group, which acted as the control, significant differences were noted. The LiSi Block GC group, in particular, had considerably higher mean difference values (208.867, p < 0.001, 95% CI [89.63, 328.10]), as did the Amber Mill group (164.200, p = 0.002, 95% CI [44.96, 283.44]) and CEREC Tessera group (137.533, p = 0.016, 95% CI [18.30, 256.77]). The e.max and n!ce Straumann groups had no statistically significant differences in mean scores (92.933, p = 0.198, 95% CI [-26.30, 212.17]). These findings imply that the clinical performance of recent lithium disilicate veneers varies when compared to the e.max CAD group. CONCLUSIONS: The fracture load of chairside CAD-CAM lithium disilicate veneers for maxillary central incisors varies according to the type of ceramic brands. Conventional pre-crystallized e.max CAD displayed higher fracture load than the recent pre- and fully-crystallized lithium disilicate materials, emphasizing the significance of choosing the right product based on the desired clinical outcome.

6.
J Prosthodont ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38706398

ABSTRACT

PURPOSE: This study evaluated the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate crown, onlay, and non-anatomical occlusal veneer (A-OV) with and without margin fabricated. MATERIALS AND METHODS: Sixty-four CAD-CAM lithium disilicate restorations were designed as (1) complete coverage crown (CCC); (2) A-OV with margin; (3) non-A-OV with margin (NA-OV-M); and (4) non-A-OV without margin (NA-OV-NM), 16 of each. Restorations were crystallized and adhesively luted to resin dies using resin cement. Specimens were then subjected to 400,000 cycles of chewing in a mastication simulator. A universal testing machine was used to apply a compressive load at a crosshead speed of 1 mm/min to the long axis of the tooth with a stainless-steel sphere until fracture occurred. One-way ANOVA followed by post hoc tests were used to assess the impact of preparation design on the fracture load of CAD-CAM lithium disilicate restorations. RESULTS: The highest fracture load was recorded for CAD-CAM lithium disilicate indirect restorations for non-A-OVs preparation with margin (2549 ± 428 N) and onlay (2549 ± 293 N) and the lowest fracture load was recorded for CCCs (2389 ± 428 N); however, there was no significant (p = 0.640) between groups. CONCLUSIONS: CAD-CAM lithium disilicate restorations fabricated for anatomical and non-A-OV preparation display a fracture resistance similar to CCCs. Conservative partial coverage restorations may be considered an acceptable approach for posterior teeth.

7.
Evid Based Dent ; 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38570647

ABSTRACT

DESIGN: This study was an extension of a randomized crossover clinical trial approved by the institutional ethics committee (approval number: D2014-148) and adhered to the CONSORT guidelines. The original study juxtaposed patient contentment with single-implant overdentures (1-IODs) against conventional complete dentures (CCDs), with patient satisfaction being the primary focus. In this follow-up study, the cognitive function of edentulous patients receiving 1-IODs was assessed, specifically monitoring for the emergence of mild cognitive impairment (MCI) throughout a three-year period. Patient outcomes were systematically recorded at predetermined intervals: initially, two months post-1-IOD placement, after one year (with groups alternated between denture types at eight-month marks), then after two and three years. A prosthodontist with a decade of expertise performed all denture-related procedures. This follow-up emphasized the cognitive outcomes using the Montreal Cognitive Assessment (MoCA-J), considering it alongside previously documented results on masticatory function, bone resorption, survival rates, and patient-reported outcomes. CASE SELECTION: Between 2015 and 2016, a follow-up study enrolled edentulous patients over 50 years of age who were proficient in Japanese, had sufficient mandibular bone for implants, and were free of systemic health issues and habits that could impact oral health. The participants were randomly divided into two groups after receiving a central mandibular implant. Group 1 initially used 1-IODs, and Group 2 used unloaded CCDs. After two months and subsequent periods, they swapped denture types. Eventually, all patients chose 1-IODs for continued use. Implant success was monitored over three years. The design featured block randomization and accounted for a sample size of 22, determined to be sufficient for evaluating the primary outcome of patient satisfaction. All patients underwent careful allocation and received customized dental interventions, with detailed radiographic planning and surgical precision guiding the implantation process. DATA ANALYSIS: Multivariable linear mixed models were used to assess within-group changes in both overall and specific cognitive function scores across five timepoints. Age, assessment interval, and upper jaw denture status were incorporated as consistent variables, while individual participants were considered variable elements in the analysis. SPSS software version 22.0 was utilized to conduct the statistical tests, and a p value threshold of 0.05 was predetermined to establish statistical significance. RESULTS: Twenty-two patients with edentulous mandibles received 1-IODs. Memory and executive functions saw significant score increases at multiple timepoints over the three-year period, with statistical significance. Though one participant dropped out and another passed away, and two did not complete the 3-year follow-up, the remaining 18 participants provided comprehensive data. Age and type of maxillary denture were significant factors, influencing MoCA-J scores with older participants and those with fixed dentures showing lower scores in certain domains. Overall, the findings illustrated the positive correlation between 1-IODs and cognitive function in older adults. CONCLUSIONS: Older adults with no natural teeth left in their mandible showed improved cognitive function after one and three years of using 1-IODs, as reflected by their total and specific cognitive domain scores. The study suggests that such implant therapy may offer protective benefits against cognitive decline, demonstrating clinical relevance for patient care, regardless of the maxillary arch (antagonist) condition.

8.
Dent J (Basel) ; 12(3)2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38534286

ABSTRACT

BACKGROUND: We compared the repeatability of the shade determination of resin composite restorations and acrylic teeth in light and darker shades at baseline and after an aging process through two digital tooth color-matching methods: using a Trios 3Shape intraoral scanner and using a Vita Easyshade Compact spectrophotometer. MATERIAL AND METHODS: Forty upper central incisor acrylic teeth in the shade A1 (n = 10) and A3 (n = 10) were randomly assigned to be restored with Filtek Bulk Fill in the shade A1 (n = 10) or A3 (n = 10). Subsequently, 20 Class V cavities were prepared in a standardized manner (mesio-distal = 3.0 mm, cervical-occlusal = 2.0 mm, depth = 1.5 mm). Cavities were restored using an universal adhesive system and resin composite in two increments and were light-cured. The shade difference between the resin composite Class V restorations in acrylic teeth of the A1 and A3 shades was evaluated at baseline and after aging. Aging was simulated using ultraviolet light for 120 h. An Easyshade device and an intraoral scanner were used under D65 illumination. Measurements were taken five times, on top of the restoration and on the acrylic teeth, in a randomized manner. RESULTS: Data analysis was on the calculation of the arithmetic mean for the percentage of repeatability conducted by the Trios scanner and the Easyshade device. There was no statistically significant comparison between the shade measurement devices (p > 0.05). At baseline, the repeatability for both the Trios intraoral scanner and the Vita Easyshade Compact device for artificial teeth in the shades A1 and A3 was 100%. After aging, the trueness recorded by the intraoral scanner and the Easyshade device for artificial teeth in the shade A1 was 80%. For Class V restoration with shade A1, the intraoral scanner recorded 80% trueness and the Easyshade device recorded 60% trueness at baseline. For shade A3, the intraoral scanner recorded 60% trueness and the Easyshade device recorded 60% trueness. CONCLUSIONS: The intraoral scanner and Easyshade device are reliable for baseline shade selection, but their accuracy decreases after aging, particularly for darker shades.

9.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38399547

ABSTRACT

With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient's existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients' quality of life.


Subject(s)
Mouth, Edentulous , Quality of Life , Humans , Denture, Complete , Mouth, Edentulous/rehabilitation , Computer-Aided Design
10.
Saudi Dent J ; 36(1): 140-145, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38375383

ABSTRACT

Purpose: Our in vitro comparative study aimed to investigate the impact of thickness and tooth shade background on the translucency of highly translucent zirconia veneers. Materials and Methods: A total of 75 5Y-TZP zirconia veneers of shade A1 were fabricated with thicknesses of 0.50 mm (n = 25), 0.75 mm (n = 25), and 1.0 mm (n = 25). The translucencies were measured on composite resin teeth with shades A1, A2, A3, A3.5, and A4 using a digital color imaging spectrophotometer. Data were analyzed using ANOVA and post hoc Tukey's test (p < 0.05). Results: The translucency values were optimal for the veneers placed over the substrate teeth with shades A1 and A2, regardless of the veneer thickness. Additionally, veneers with a thickness of 0.50 mm exhibited significantly higher translucency than those with thicknesses of 0.75 mm and 1.0 mm. Conclusions: Our study demonstrated that the translucency of the highly translucent zirconia veneers was influenced by both veneer thickness and tooth shade background. The optimal veneer thickness for achieving the highest translucency was 0.50 for the veneers with A1 and A2 shades placed over the substrate teeth. Clinical Relevance: The optimal thickness for achieving the highest translucency of the highly translucent zirconia laminate veneers was 0.50 mm for the veneers with A1 and A2 shades placed over the substrate teeth. Clinicians and dental technicians could consider this when selecting materials for aesthetic restorations.

11.
J Prosthodont ; 33(3): 281-287, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37014263

ABSTRACT

PURPOSE: This study aimed to assess the fracture resistance of monolithic zirconia-reinforced lithium silicate laminate veneers (LVs) fabricated on various incisal preparation designs. MATERIALS AND METHODS: Sixty maxillary central incisors with various preparation designs were 3D-printed, 15 each, including preparation for: (1) LV with feathered-edge design; (2) LV with butt-joint design; (3) LV with palatal chamfer; and (4) full-coverage crown. Restorations were then designed and manufactured from zirconia-reinforced lithium silicate (ZLS) following the contour of a pre-operation scan. Restorations were bonded to the assigned preparation using resin cement and following the manufacturer's instructions. Specimens were then subjected to 10,000 thermocycles at 5 to 55°C with a dwell time of 30 s. The fracture strength of specimens was then assessed using a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA and Bonferroni correction multiple comparisons were used to assess the fracture strength differences between the test groups (α = 0.001). Descriptive fractographic analysis of specimens was carried out with scanning electron microscopy images. RESULTS: Complete coverage crown and LV with palatal chamfer design had the highest fracture resistance values (781.4 ± 151.4 and 618.2 ± 112.6 N, respectively). Single crown and LV with palatal chamfer had no significant difference in fracture strength (p > 05). LV with feathered-edge and butt-joint designs provided significantly (p < 05) lower fracture resistance than complete coverage crown and LV with palatal chamfer design. CONCLUSION: The fracture resistance of chairside milled ZLS veneers was significantly influenced by the incisal preparation designs tested. Within the limitation of this study, when excessive occlusal forces are expected, LV with palatal chamfer display is the most conservative method of fabricating an indirect restoration.


Subject(s)
Ceramics , Dental Porcelain , Dental Porcelain/therapeutic use , Flexural Strength , Lithium , Materials Testing , Dental Stress Analysis , Crowns , Zirconium/therapeutic use , Silicates , Computer-Aided Design , Dental Prosthesis Design
12.
Biomimetics (Basel) ; 8(8)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38132514

ABSTRACT

Chitosan, a natural polysaccharide sourced from crustaceans and insects, is often used with hydrogels in wound care. Evaluating its cytotoxicity and antimicrobial properties is crucial for its potential use in dentistry. OBJECTIVE: To investigate the mechanical properties of gelatin hydrogels based on decaethylated chitosan and antimicrobial activity against Streptococcus mutans and their biological effects with stem cells from apical papilla (SCAPs). MATERIAL AND METHODS: Gelatin-chitosan hydrogels were synthesized at concentrations of 0%, 0.2% and 0.5%. Enzymatic and hydrolytic degradation, along with swelling capacity, was assessed. Fourier transform infrared spectroscopy (FTIR) analysis was employed to characterize the hydrogels. The interaction between hydrogels and SCAPs was examined through initial adhesion and cell proliferation at 24 and 48 h, using the Thiazolyl Blue Tetrazolium Bromide (MTT assay). The antimicrobial effect was evaluated using agar diffusion and a microdilution test against S. mutans. Uniaxial tensile strength (UTS) was also measured to assess the mechanical properties of the hydrogels. RESULTS: The hydrogels underwent hydrolytic and enzymatic degradation at 30, 220, 300 min and 15, 25, 30 min, respectively. Significantly, (p < 0.01) swelling capacity occurred at 20, 40, 30 min, respectively. Gelatin-chitosan hydrogels' functional groups were confirmed using vibrational pattern analysis. SCAPs proliferation corresponded to 24 h = 73 ± 2%, 82 ± 2%, 61 ± 6% and 48 h = 83 ± 11%, 86 ± 2%, 44 ± 2%, respectively. The bacterial survival of hydrogel interaction was found to be 96 ± 1%, 17 ± 1.5% (p < 0.01) and 1 ± 0.5% (p < 0.01), respectively. UTS showed enhanced (p < 0.05) mechanical properties with chitosan presence. CONCLUSION: Gelatin-chitosan hydrogels displayed favorable degradation, swelling capacity, mild dose-dependent cytotoxicity, significant proliferation with stem cells from apical papilla (SCAPs), substantial antimicrobial effects against S. mutans and enhanced mechanical properties. These findings highlight their potential applications as postoperative care dressings.

13.
Biomimetics (Basel) ; 8(7)2023 Oct 29.
Article in English | MEDLINE | ID: mdl-37999155

ABSTRACT

Assessing the biocompatibility of endodontic root-end filling materials through cell line responses is both essential and of utmost importance. This study aimed to the cytotoxicity of the type of cell death through apoptosis and autophagy, and odontoblast cell-like differentiation effects of MTA, zinc oxide-eugenol, and two experimental Portland cements modified with bismuth (Portland Bi) and barium (Portland Ba) on primary cell cultures. Material and methods: The cells corresponded to human periodontal ligament and gingival fibroblasts (HPLF, HGF), human pulp cells (HPC), and human squamous carcinoma cells from three different patients (HSC-2, -3, -4). The cements were inoculcated in different concentrations for cytotoxicity evaluation, DNA fragmentation in electrophoresis, apoptosis caspase activation, and autophagy antigen reaction, odontoblast-like cells were differentiated and tested for mineral deposition. The data were subject to a non-parametric test. Results: All cements caused a dose-dependent reduction in cell viability. Contact with zinc oxide-eugenol induced neither DNA fragmentation nor apoptotic caspase-3 activation and autophagy inhibitors (3-methyladenine, bafilomycin). Portland Bi accelerated significantly (p < 0.05) the differentiation of odontoblast-like cells. Within the limitation of this study, it was concluded that Portland cement with bismuth exhibits cytocompatibility and promotes odontoblast-like cell differentiation. This research contributes valuable insights into biocompatibility, suggesting its potential use in endodontic repair and biomimetic remineralization.

14.
Int J Oral Implantol (Berl) ; 16(4): 339-348, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37994821

ABSTRACT

Incomplete orthodontic therapy can lead to severe root resorption, resulting in mobile and non-restorable teeth. This clinical report presents the diagnosis, treatment planning and oral rehabilitation of a young woman with failing dentition in the anterior maxilla due to orthodontically induced root resorption. The patient's chief complaint was mobile maxillary anterior teeth 2 years after discontinuing orthodontic treatment. Radiographic and clinical evaluations revealed a missing right first premolar and left premolars and grade III mobility from the right canine to the left lateral incisor. Due to a hopeless prognosis, extraction of the maxillary anterior teeth was planned, followed by grafting procedures. Four implants were immediately placed in the fresh sockets of the canine and central sites, and a removable provisional appliance was delivered to contour the soft tissues involved. The final restorations consisted of two three-unit layered zirconia implant-supported fixed dental prostheses. Well-planned immediate implant therapy and zirconia restorations can successfully replace mobile teeth with severe root resorption caused by external surface resorption from incomplete orthodontic treatment. Combining grafting procedures during implant placement can replace hard tissue lost due to extractions, whereas provisional restorations can re-establish optimal tissue architecture in the aesthetic zone. The present case offers insight into effective strategies for treating non-compliant or uncooperative patients with failing dentition due to orthodontically induced root resorption.


Subject(s)
Dental Implants, Single-Tooth , Dental Implants , Root Resorption , Female , Humans , Dental Implants/adverse effects , Root Resorption/diagnostic imaging , Root Resorption/etiology , Root Resorption/surgery , Maxilla/diagnostic imaging , Maxilla/surgery , Dentition , Esthetics, Dental
15.
Cureus ; 15(9): e45299, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37846271

ABSTRACT

The present report describes a technique in which the maxillary bone was molded to the desired location using a series of instruments for ridge-splitting procedures. This technique aims to improve bone quality all around the implants at both the crest and apex locations. In some clinical scenarios, insufficient horizontal bone with less than 3 mm prevents implant placement. Thus, ridge splitting is a treatment of choice, and this technique creates bone expansion to form a better receptor site for endosteal implants. A case report is presented involving a completely edentulous 52-year-old male patient presented to the clinic with a horizontal bone defect. The patient complained of having difficulty eating and wants to improve his smile. In this clinical case, a modified ridge-splitting technique was employed, differing from the conventional procedure that uses mallets, chisels, or osteotomes. A lancet and spatula were used for precise ridge splitting, followed by the placement of four endosseous tapered implants-two on each side (Dentis USA, La Palma, USA). Each implant had a diameter of 3.7 mm and a length of 10 mm. These implants were clinically placed in a single visit, with a torque of 30 N/cm² applied to ensure secure fixation. To accommodate the patient's unique maxillary bone anatomy, 25-degree angulated abutments were chosen for the four implants, ensuring a common path of insertion, and optimal angulation for long-term stability and aesthetics. Subsequently, a cemented provisional dental prosthesis restoration was fitted, and the patient reported satisfaction with both function and aesthetics. After a period of five months of osseointegration, the stability of the implants was assessed using a resonance frequency analyzer, yielding positive results. The average resonance frequency values for the maxillary left (canine and premolar) were ISQ 68 and ISQ 71, respectively, while for the maxillary right (lateral incisor and premolar), the values were ISQ 69 and ISQ 73. These readings indicate satisfactory implant stability following the osseointegration process. The postoperative cone-beam computed tomography (CBCT) showed gain to the bone width besides better function and good results concerning the esthetics. This report describes a modified ridge-splitting technique with a predictable and satisfactory outcome that fulfilled the patient's demands. The presented approach overcomes the disadvantages of two-staged implant placement bone grafting procedures and is also a more affordable option for the patient. CBCT evaluation confirmed bone gain with minimal morbidity after the procedure.

16.
Int J Esthet Dent ; 18(4): 390-404, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37819566

ABSTRACT

Tooth-reduction guides offer a more controlled and conservative tooth preparation. Many types of tooth-reduction guides are available such as those with horizontal or vertical reduction grooves. A transparent cross-shaped tooth-reduction guide allows the clinician to make vertical and horizontal depth grooves to evaluate tooth reduction in all directions. The reference grooves on the guide enable the clinician to use a periodontal probe to measure the reduction accurately, and the transparent material provides a clear view of the entire tooth. Controlled tooth reduction offers a more conservative approach that is key for long-term bonded ceramic restorations. The multiaxial rigid transparent tooth-reduction guide could facilitate the provision of ultrathin handcrafted porcelain veneers to predictably fulfill patients' esthetic demands while preserving more tooth structure. The use of technically sound and artistically documented photographic evidence further underscores the effectiveness of this approach, particularly when intra-enamel preparations and adhesive luting under rubber dam isolation are employed. The present article describes a novel 3D-printed guide design that allows the clinician to perform the reduction grooves and evaluate the preparation in the horizontal and vertical directions within the same guide.


Subject(s)
Dental Porcelain , Dental Veneers , Humans , Esthetics, Dental , Ceramics , Printing, Three-Dimensional
17.
J Prosthet Dent ; 2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37739880

ABSTRACT

STATEMENT OF PROBLEM: Studies on the fracture performance of a recently introduced computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate ceramic containing virgilite with different cements are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the fracture resistance of crowns made of a recently introduced chairside CAD-CAM lithium disilicate containing virgilite cemented with different types of adhesive luting cement. MATERIAL AND METHODS: Sixty complete coverage crowns for a maxillary right central incisor were milled out of a lithium disilicate with virgilite (CEREC Tessera) (n=48) and a traditional lithium disilicate (e.max CAD) (n=12) using a chairside CAD-CAM system (Primescan). The central incisor tooth preparation included a 1.5-mm incisal reduction, a 1.0-mm axial reduction, and a 1.0-mm chamfer finish line. The restorations were bonded with different types of resin cement to 3D printed dies of the tooth preparation and were divided into 5 groups (n=12 per group): e.max CAD with Multilink Automix (E.Mu); Tessera with Multilink Automix (T.Mu); Tessera with Calibra (T.Ca); Tessera with Unicem (T.Un); and Tessera with Speedcem (T.Sp). The cemented restorations were stored in water for 30 days and then loaded until they were fractured in compression. The load at fracture was analyzed with a 1-way analysis of variance (ANOVA) and the honestly significant difference (HSD) Tukey test (α=.05). RESULTS: The mean fracture resistance of traditional lithium disilicate and virgilite lithium disilicate anterior crowns significantly differed depending on the type of resin cement used (P<.05). Group E.Mu displayed the highest values (946.35 ±155 N), followed by group T.Un (819.59 ±232 N), group T.Sp (675.52 ±153 N), and group T.Mu (656.95 ±193 N). The lowest values were displayed by group T.Ca (567.94 ±184 N). CONCLUSIONS: The fracture resistance of lithium disilicate containing virgilite and traditional lithium disilicate crowns cemented with the same cement displayed statistically similar values. However, significant differences were observed when the virgilite lithium disilicate crowns were cemented with different types of adhesive luting cement. The crowns in the T.Ca group displayed the lowest fracture resistance.

18.
J Evid Based Dent Pract ; 23(3): 101886, 2023 09.
Article in English | MEDLINE | ID: mdl-37689455

ABSTRACT

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Moro JDS, Soares JP, Massignan C, Oliveira LB, Ribeiro DM, Cardoso M, Canto GL, Bolan M. Burnout syndrome among dentists: a systematic review and meta-analysis. J Evid Based Dent Pract. 2022 Sep;22(3):101,724. doi: 10.1016/j.jebdp.2022.101724. Epub 2022 Apr 2. PMID: 36162888 SOURCE OF FUNDING: University funds. TYPE OF STUDY/DESIGN: Systematic review with meta-analysis.


Subject(s)
Burnout, Psychological , Dentistry , Humans , Prevalence
19.
J Evid Based Dent Pract ; 23(3): 101915, 2023 09.
Article in English | MEDLINE | ID: mdl-37689457

ABSTRACT

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Yang S, Chen J, Li A, Deng K, Li P, Xu S. Accuracy of autonomous robotic surgery for single-tooth implant placement: a case series. J Dent. 2023;132:104451. doi:10.1016/j.jdent.2023.104451. Epub 2023 Feb 11. PMID: 36781099. SOURCE OF FUNDING: This case series study was supported by grants from the Guangdong Basic and Applied Basic Research Foundation, Science and Technology Projects in Guangzhou, Science Research Cultivation Program, and Clinical Research Initiation Plan of the Stomatological Hospital, Southern Medical University, China. TYPE OF STUDY/DESIGN: Case series. No a priori power calculation or pilot data. Nonconsecutive participant recruitment.


Subject(s)
Dental Implants, Single-Tooth , Robotic Surgical Procedures , Humans , Esthetics, Dental , China , Technology
20.
J Prosthet Dent ; 2023 Sep 21.
Article in English | MEDLINE | ID: mdl-37741726

ABSTRACT

Removable partial dentures have been used to rehabilitate partially edentulous patients for decades. A challenging but commonly encountered procedure is retrofitting a crown to an existing removable partial denture. Several techniques have been proposed for fabricating these complex prostheses, some involving the intraoral application of polymers to the abutment tooth or making impressions of the preparation with the removable prosthesis seated. The present technique presents an approach that simplifies the design and fabrication of retrofitted crowns for fractured abutment teeth needing foundation restorations. This approach involves the implementation of computer-aided design and computer-aided manufacturing technology to record and utilize the contours of the foundation restoration established intraorally as a blueprint for the retrofitted crown.

SELECTION OF CITATIONS
SEARCH DETAIL
...