Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Aliment Pharmacol Ther ; 52(6): 1031-1041, 2020 09.
Article in English | MEDLINE | ID: mdl-32677733

ABSTRACT

BACKGROUND: Faecal immunochemical testing (FIT) is recommended by the National Institute for Health and Care Excellence (NICE) to triage symptomatic primary care patients for further investigation of colorectal cancer. AIM: To ascertain the diagnostic performance of FIT in symptomatic adult primary care patients. METHODS: Faecal samples from routine primary care practice in Oxfordshire, UK were analysed using the HM-JACKarc FIT method between March 2017 and March 2020. Clinical details were recorded. Patients were followed for up to 36 months in linked hospital records for evidence of benign and serious (colorectal cancer, high-risk adenomas and bowel inflammation) colorectal disease. The diagnostic accuracy of FIT is reported by gender, age group and FIT threshold. RESULTS: In 9896 adult patients with at least 6-month follow-up, a FIT result ≥10 µg Hb/g faeces had a sensitivity for colorectal cancer of 90.5% (95% CI 84.9%-96.1%), specificity 91.3% (90.8%-91.9%), positive predictive value (PPV) 10.1% (8.15%-12.0%) and negative predictive value (NPV) 99.9% (99.8%-100.0%). The PPV and specificity for serious colorectal disease were higher and the sensitivity and NPV lower than for colorectal cancer alone. The area under the curve for all adults did not change substantially by gender or by increasing the minimum age of testing. Using ≥10 µg Hb/g faeces, 10% of adults would be investigated to detect 91% of cancers, a number needed to scope of ten to detect one cancer. Using ≥7, ≥50 and ≥150 µg Hb/g faeces, 11%, 4% and 3% of adults would be investigated, and 91%, 74% and 54% cancers detected, respectively. CONCLUSION: A FIT threshold of ≥10 µg Hb/g faeces would be appropriate to triage adult patients presenting to primary care with symptoms of serious colorectal disease. FIT may be used to reprioritise patients referred with colorectal cancer symptoms whose investigations have been delayed by the COVID-19 pandemic.


Subject(s)
Colorectal Neoplasms/diagnosis , Feces/cytology , Occult Blood , Primary Health Care/organization & administration , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Young Adult
2.
Frontline Gastroenterol ; 10(4): 347-355, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31656559

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of guaiac faecal occult blood (gFOB) testing with faecal immunochemical test (FIT) in a low-risk symptomatic primary care population to provide objective data on which to base local referral guidelines. DESIGN: Stool samples from routine primary care practice sent for faecal occult blood testing were analysed by a standard gFOB method and the HM-JACKarc FIT between January and March 2016. Symptoms described on the test request were recorded. Patients were followed up over 21 months for evidence of serious gastrointestinal pathology including colorectal adenocarcinoma. RESULTS: In 238 patients, the sensitivity and specificity for colorectal adenocarcinoma detection using gFOB were 85.7% and 65.8%, respectively, compared with 85.7% and 89.2% for FIT. The positive predictive value (PPV) for gFOB was 7.1% and negative predictive value (NPV) was 99.3%. Comparatively, the PPV for FIT was 19.4% and NPV 99.5%. The improved performance of FIT over gFOB was due to a lower false positive rate (10.8 vs 34.2, p≤0.01) with no increase in the false negatives rate. For any significant colorectal disease, the PPV for FIT increased to 35.5% with a reduction in NPV to 95.7%. CONCLUSION: In this low-risk symptomatic patient group, the proportion of samples considered positive by FIT was considerably lower than gFOB with the same rate of colorectal adenocarcinoma detection. One in three of those with positive FIT had a significant colorectal disease. This supports National Institute of Health and Care Excellence recommendation that FIT can be reliably used as a triage test in primary care without overburdening endoscopy resources.

SELECTION OF CITATIONS
SEARCH DETAIL
...