Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Cardiovasc Intervent Radiol ; 44(3): 452-459, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33145701

ABSTRACT

PURPOSE: The presence of metal implants may reduce angiographic image quality due to automated beam adjustments. Digital variance angiography (DVA) is reported to be superior to digital subtraction angiography (DSA) with increased contrast-to-noise ratio (CNR) and better image quality. The aim of the study was to evaluate whether DVA could counterbalance the image quality impairment of lower-limb angiographies with metal implants. MATERIALS AND METHODS: From November 2019 to January 2020, 85 raw lower-limb iodine contrast angiograms of 12 patients with metal implants were processed retrospectively with DVA analyses. For objective comparison, CNR of DSA and DVA images was calculated and the ratio CNRDVA/CNRDSA was determined. Visual image quality was evaluated in a paired comparison and by a five-grade Likert scale by three experienced radiologists. RESULTS: The CNR was calculated and compared in 1252 regions of interest in 37 image pairs containing metal implants. The median ratio of CNRDVA/CNRDSA was 1.84 with an interquartile range of 1.35-2.32. Paired comparison resulted in 84.5% in favour of DVA with an interrater agreement of 83.2% (Fleiss κ 0.454, p < 0.001). The overall image quality scores for DSA and DVA were 3.64 ± 0.08 and 4.43 ± 0.06, respectively (p < 0.001, Wilcoxon signed-rank test) with consistently higher individual ratings for DVA. CONCLUSION: Our small-sample pilot study shows that DVA provides significantly improved image quality in lower-limb angiography with metal implants, compared to DSA imaging. The improved CNR suggest that this approach could reduce radiation exposure for lower-limb angiography with metal implants. LEVEL OF EVIDENCE: Level 4, case studies.


Subject(s)
Angiography, Digital Subtraction/methods , Image Processing, Computer-Assisted/methods , Leg/blood supply , Leg/diagnostic imaging , Prostheses and Implants , Aged , Aged, 80 and over , Artifacts , Contrast Media , Female , Humans , Male , Metals , Pilot Projects , Retrospective Studies
2.
Eur J Radiol ; 131: 109244, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32905956

ABSTRACT

PURPOSE: To ensure that patients survive cardiac arrest, cardiopulmonary resuscitation (CPR) is needed. However, the procedure itself can lead to severe injuries. This study aims to examine both possibilities of resuscitation - mechanical or manual - with regard to their risk of injury. To this end, we compare the injuries patterns in both groups of patients after successful resuscitation based on computer tomography (CT). METHODS: This single-centre retrospective study included 32 patients (female: 21.87 %, male: 78.12 %, Mean age: 60.22 ± 13.93 years) with cardiac arrest followed by successful mechanical CPR, who underwent an early whole-body CT. A control group of 32 patients (female: 21.87 %, male: 78.12 %, mean age: 60.75 ± 13.34 years) that had been resuscitated successfully with manual CPR was matched according to gender and age for a better statistical comparison. Patients with cardiac arrest due to trauma were excluded from the study population. RESULTS: Mechanically resuscitated patients showed significantly more CPR-related injuries than those who were resuscitated manually (100 % vs. 84.37 %; p = 0.02). In particular, dislocated rib fractures (40.47 vs. 23.80 mean rank, p < 0.01), sternal fractures (74.19 % vs. 25 %; p < 0,01), bleeding complications (29.03 % vs. 3.12 %; p = 0.01), pneumothorax (38.71 % vs. 9.37 %; p = 0.01), mediastinal haematomas (58.01 % vs. 25 %, p = 0.01) and liver lacerations (29.03 % vs. 0 %, p = 0.04) were observed significantly more in patients after mechanical CPR compared to those with manual resuscitation. CONCLUSIONS: The guideline-based use of mechanical CPR results in a significant increase of internal and musculoskeletal injuries compared to manual CPR.


Subject(s)
Cardiopulmonary Resuscitation/adverse effects , Cardiopulmonary Resuscitation/methods , Heart Arrest/therapy , Thoracic Injuries/diagnostic imaging , Thoracic Injuries/etiology , Tomography, X-Ray Computed/methods , Cardiopulmonary Resuscitation/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies , Rib Fractures/diagnostic imaging , Rib Fractures/etiology , Survivors
3.
Emerg Radiol ; 27(1): 23-29, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31468207

ABSTRACT

PURPOSE: Non-traumatic cardiac arrest (CA) and return of spontaneous circulation (ROSC) after cardiopulmonary resuscitation (CPR) are often associated with multiple pathologies. Expecting a high prevalence of important findings, a whole-body CT (WBCT) could be of relevance for therapy. The aim of this study is to investigate the feasibility and diagnostic yield of an early WBCT in this setting. METHODS: This single-center retrospective study included 100 consecutive patients (27 female; 73 male; mean age 68.5± 12.57 years) with non-traumatic, in- and out-of-hospital CA and ROSC following CPR, who underwent a contrast-enhanced WBCT within 6 h after ROSC over 12 months. CT findings were determined corresponding to anatomical region. RESULTS: Early WBCT was successfully carried out in 100% of the patients with CA and ROSC after CPR. Acute pathologies were found not only in the chest but also in the head (15%) and the abdomen (6%). Early global brain edema (n = 12), acute stroke (n = 3), pulmonary embolism (n = 10), pneumothorax (26%), acute abdominal pathologies (n = 6), iatrogenic bleeding (4%), and CPR-related injuries (93%) were detected by CT right from the beginning of the post-cardiac arrest care. CONCLUSIONS: An early WBCT is feasible and provides added diagnostic value for patients with ROSC after non-traumatic CA.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest/complications , Heart Arrest/therapy , Tomography, X-Ray Computed/methods , Whole Body Imaging , Aged , Contrast Media , Female , Humans , Male , Retrospective Studies
4.
Clin Otolaryngol ; 41(5): 467-71, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26434600

ABSTRACT

BACKGROUND: Robin Sequence (RS) is usually defined as the combination of micrognathia, glossoptosis and upper airway obstruction. No objective criteria to diagnose RS exist. To compare management strategy results, a single RS definition using objective criteria is needed. The most frequently used primary diagnostic tool for glossoptosis is awake Flexible Fiberoptic Laryngoscopy (aFFL). OBJECTIVES: To determine the reliability of the aFFL videos as an independent diagnostic tool itself, rather than on the complete evaluation of a patient. DESIGN, SETTING, PARTICIPANTS: All RS individuals from an existing cohort with an available aFFL video were included retrospectively. Thirty age-matched patients without pathologic findings on aFFL were used as controls. aFFL videos were scored by six otolaryngologists as: a. Marked glossoptosis, b. Mild glossoptosis, c. Severity unknown, d. No glossoptosis, e. Insufficient video quality. Videos were anonymised and rated twice, in altered sequences, after a washout period of minimally 2 weeks. MAIN OUTCOME MEASURES: Inter-rater and intrarater agreement. RESULTS: Twenty-six videos of 16 RS patients and 30 videos of controls were included. Inter-rater agreement was fair in the whole group (κ: 0.320) and RS group (κ: 0.226), and fair to moderate in determining presence of glossoptosis (total group κ: 0.430; RS κ: 0.302; controls κ: 0.212). The intrarater agreement for the presence of glossoptosis in RS was moderate (κ: 0.541). CONCLUSIONS: aFFL offers fair to moderate inter-rater agreement, with moderate intrarater agreement, in evaluating glossoptosis in RS. Using aFFL as the single tool in choosing management strategies in RS seems insufficient. There is need for a more reliable, patient friendly diagnostic tool or an internationally accepted aFFL scoring system, to diagnose glossoptosis in RS.


Subject(s)
Glossoptosis/diagnosis , Laryngoscopy/methods , Pierre Robin Syndrome/complications , Adolescent , Adult , Child , Child, Preschool , Female , Fiber Optic Technology , Glossoptosis/etiology , Humans , Infant , Infant, Newborn , Male , Reproducibility of Results , Retrospective Studies , Video Recording
5.
Mol Psychiatry ; 21(9): 1309-20, 2016 09.
Article in English | MEDLINE | ID: mdl-26643538

ABSTRACT

It is still controversial which mediators regulate energy provision to activated neural cells, as insulin does in peripheral tissues. Interleukin-1ß (IL-1ß) may mediate this effect as it can affect glucoregulation, it is overexpressed in the 'healthy' brain during increased neuronal activity, and it supports high-energy demanding processes such as long-term potentiation, memory and learning. Furthermore, the absence of sustained neuroendocrine and behavioral counterregulation suggests that brain glucose-sensing neurons do not perceive IL-1ß-induced hypoglycemia. Here, we show that IL-1ß adjusts glucoregulation by inducing its own production in the brain, and that IL-1ß-induced hypoglycemia is myeloid differentiation primary response 88 protein (MyD88)-dependent and only partially counteracted by Kir6.2-mediated sensing signaling. Furthermore, we found that, opposite to insulin, IL-1ß stimulates brain metabolism. This effect is absent in MyD88-deficient mice, which have neurobehavioral alterations associated to disorders in glucose homeostasis, as during several psychiatric diseases. IL-1ß effects on brain metabolism are most likely maintained by IL-1ß auto-induction and may reflect a compensatory increase in fuel supply to neural cells. We explore this possibility by directly blocking IL-1 receptors in neural cells. The results showed that, in an activity-dependent and paracrine/autocrine manner, endogenous IL-1 produced by neurons and astrocytes facilitates glucose uptake by these cells. This effect is exacerbated following glutamatergic stimulation and can be passively transferred between cell types. We conclude that the capacity of IL-1ß to provide fuel to neural cells underlies its physiological effects on glucoregulation, synaptic plasticity, learning and memory. However, deregulation of IL-1ß production could contribute to the alterations in brain glucose metabolism that are detected in several neurologic and psychiatric diseases.


Subject(s)
Interleukin-1beta/metabolism , Neurons/metabolism , Animals , Astrocytes/immunology , Astrocytes/metabolism , Autocrine Communication/physiology , Brain/immunology , Brain/metabolism , Cells, Cultured , Glucose/metabolism , Humans , Interleukin-1beta/immunology , Learning/drug effects , Long-Term Potentiation/drug effects , Mice , Myeloid Differentiation Factor 88/metabolism , Neuronal Plasticity/drug effects , Neurons/immunology , Paracrine Communication/physiology , Signal Transduction/drug effects
6.
Ann Oncol ; 24(5): 1282-90, 2013 May.
Article in English | MEDLINE | ID: mdl-23293110

ABSTRACT

BACKGROUND: Hypoxic environment of pancreatic cancer (PC) implicates high vascular in-growth, which may be influenced by angiogenesis-related germline polymorphisms. Our purpose was to evaluate polymorphisms of vascular endothelial growth factor receptor 2 (VEGFR-2), CXC chemokine receptor 2 (CXCR-2), proteinase-activated receptor 1 (PAR-1) and endostatin (ES) as prognostic markers for disease-free (DFS) and overall survival (OS) in PC. PATIENTS AND METHODS: Genotyping of 173 patients, surgically treated for PC between 2004 and 2011, was carried out by TaqMan(®) genotyping assays or polymerase chain reaction. Chi-square test, Kaplan-Meier estimator and Cox regression hazard model were used to assess the prognostic value of selected polymorphisms. RESULTS: VEGFR-2 -906 T/T and PAR-1 -506 Del/Del genotypes predicted longer DFS (P = 0.003, P = 0.014) and OS (VEGFR-2 -906, P = 0.011). CXCR-2 +1208 T/T genotype was a negative predictor for DFS (P < 0.0001). Combined analysis for DFS and OS indicated that patients with the fewest number of favorable genotypes simultaneously present (VEGFR-2 -906 T/T, CXCR-2 +1208 C/T or C/C and PAR-1 -506 Del/Del) were at the highest risk for recurrence or death (P < 0.0001). CONCLUSION: VEGFR-2 -906 C>T, CXCR-2 +1208 C>T and PAR-1 -506 Ins/Del polymorphisms are potential predictors for survival in PC.


Subject(s)
Pancreatic Neoplasms/genetics , Pancreatic Neoplasms/mortality , Receptor, PAR-1/genetics , Receptors, Interleukin-8B/genetics , Vascular Endothelial Growth Factor Receptor-2/genetics , Adult , Aged , Aged, 80 and over , Biomarkers, Tumor/genetics , Disease-Free Survival , Female , Genotype , Humans , Male , Middle Aged , Neovascularization, Pathologic/genetics , Pancreatic Neoplasms/surgery , Polymorphism, Single Nucleotide , Survival , Pancreatic Neoplasms
7.
Chirurg ; 83(8): 719, 722-5, 2012 Aug.
Article in German | MEDLINE | ID: mdl-22878577

ABSTRACT

Bleeding and perforation in esophageal cancer patients are rare but associated with a high morbidity and mortality. Because of disappointing results after primary surgical exploration and resection endoscopic intervention was introduced as the primary treatment option with an improved outcome. Aortoesophageal and esophagobronchial fistulas may occur spontaneously or secondary to stenting of the esophagus. They are uncommon but fatal if untreated. The first option is prompt placement of a stent graft as a bridging solution followed by surgical treatment.


Subject(s)
Adenocarcinoma/surgery , Emergencies , Esophageal Fistula/surgery , Esophageal Neoplasms/surgery , Esophageal Perforation/surgery , Gastrointestinal Hemorrhage/surgery , Adenocarcinoma/diagnosis , Adenocarcinoma/mortality , Aortic Diseases/diagnosis , Aortic Diseases/mortality , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/mortality , Bronchial Fistula/diagnosis , Bronchial Fistula/mortality , Bronchial Fistula/surgery , Esophageal Fistula/diagnosis , Esophageal Fistula/mortality , Esophageal Neoplasms/diagnosis , Esophageal Neoplasms/mortality , Esophageal Perforation/diagnosis , Esophageal Perforation/mortality , Esophagoscopy/methods , Esophagoscopy/mortality , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/mortality , Humans , Prognosis , Reoperation/methods , Reoperation/mortality , Stents , Survival Rate , Vascular Fistula/diagnosis , Vascular Fistula/mortality , Vascular Fistula/surgery
8.
HNO ; 60(7): 581-9, 2012 Jul.
Article in German | MEDLINE | ID: mdl-22622357

ABSTRACT

Tracheotomies are increasingly performed in the pediatric population in the context of long-term treatment. There are specific pediatric aspects that require attention: differences in the pediatric compared to adult anatomy, the necessity for later reconstruction and the negative impact on oral feeding and speech development. Caring for pediatric tracheostomy patients is more challenging compared to adult patients. This needs to be addressed by a dedicated team during both in- and outpatient treatment.


Subject(s)
Deglutition Disorders/rehabilitation , Deglutition Disorders/surgery , Speech Disorders/surgery , Tracheal Diseases/surgery , Tracheostomy/trends , Tracheotomy/trends , Child , Humans
9.
Rev Sci Instrum ; 78(7): 074903, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17672786

ABSTRACT

A quartz crystal microbalance (QCM) is described, which is based on a torsional resonator, rather than a conventional thickness-shear resonator. Typical applications are measurements of film thickness in the coating industry and monitoring of biofouling. The torsional QCM is about a factor of 100 less sensitive than the conventional QCM. On the other hand, it can probe film thicknesses in the range of hundreds of microns, which is impossible with the conventional QCM due to viscoelastic artifacts. Data acquisition and data analysis proceed in analogy to the conventional QCM. An indicator of the material's softness can be extracted from the bandwidth of the resonance. Within the small-load approximation, the frequency shift is independent of whether the sample is applied to the face or to the side of the cylinder. Details of the geometry matter if the viscoelastic properties of the sample are of interest.


Subject(s)
Acoustics/instrumentation , Computer-Aided Design , Electrochemistry/instrumentation , Models, Theoretical , Quartz/chemistry , Transducers , Computer Simulation , Equipment Design , Equipment Failure Analysis , Miniaturization , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL