ABSTRACT
OBJECTIVE: Although American and European consensus statements advocate using the ratio of the transmitral E velocity and tissue Doppler early diastolic mitral annular velocity (E/e') in the assessment of left-sided heart filling pressures, recent reports have questioned the reliability of this ratio to predict left atrial pressures in a variety of disease states. The authors hypothesized that there is a clinically significant correlation between E/e' and pulmonary capillary wedge pressure (PCWP) in patients with severe aortic stenosis. DESIGN: Retrospective cohort study. PARTICIPANTS: The study comprised 733 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve replacement for severe aortic stenosis. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: PCWP and E/e'ave (average of the lateral and medial annulus tissue Doppler velocities) were measured with a pulmonary artery catheter and transthoracic echocardiography during preprocedural evaluation. Patients were grouped by left ventricular ejection fraction (LVEF) ≥50% and LVEF <50%. Spearman rank correlation, analysis of variance, and t and chi-square tests were used to analyze the data. Seventy-nine patients met the inclusion criteria. There was no significant correlation between E/e'ave and PCWP (nâ¯=â¯79, Spearman râ¯=â¯0.096; pâ¯=â¯0.3994). This correlation did not improve when ventricular function was considered (LVEF <50%: nâ¯=â¯11, Spearman râ¯=â¯-0.097; pâ¯=â¯0.776 and LVEF ≥50%: nâ¯=â¯68, Spearman râ¯=â¯0.116; pâ¯=â¯0.345). There was no statistically significant difference in mean PCWP between each range of E/e'ave. CONCLUSION: A clinically relevant relationship between E/e' and PCWP was not observed in patients with severe aortic stenosis.
Subject(s)
Aortic Valve Stenosis , Ventricular Function, Left , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography, Doppler , Humans , Pulmonary Wedge Pressure , Reproducibility of Results , Retrospective Studies , Stroke VolumeABSTRACT
Prosthesis-patient mismatch (PPM) is relatively common after aortic valve replacement (AVR) and generally is associated with reduced regression of left ventricular (LV) mass. PPM after valve-in-valve transcatheter aortic valve replacement (TAVR) was reported to be 38%. PPM generally is manifested clinically by dyspnea and echocardiographically by high transvalvular gradients. In this E-Challenge, the authors will review a case of a late clinical presentation of PPM 1-year following a valve-in-valve TAVR.
Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Cardiac Catheterization , Echocardiography , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Risk Factors , Time FactorsABSTRACT
According to the Chinese historical books, Records of the Three Kingdoms () and Book of the Later Han (), Hua Tuo (, 140 - 208), a Traditional Chinese medicine (TCM) physician invented Mafeisan, an oral herbal general anesthetic, more than 1800 years ago during Eastern Han Dynasty. However, no written record of ingredients of the original Mafeisan has been found anywhere so far although there have been several similar anesthetic prescriptions published in TCM books later. There has been controversy over the existence of Mafeisan and even Hua Tuo in Chinese literature. We did extensive literature search and analysis, and believe that there indeed was Mafeisan in Hua Tuo's time.