Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 93(5): 053303, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35649771

ABSTRACT

Image plates (IPs) are a popular detector in the field of laser driven ion acceleration, owing to their high dynamic range and reusability. An absolute calibration of these detectors to laser-driven protons in the routinely produced tens of MeV energy range is, therefore, essential. In this paper, the response of Fujifilm BAS-TR IPs to 1-40 MeV protons is calibrated by employing the detectors in high resolution Thomson parabola spectrometers in conjunction with a CR-39 nuclear track detector to determine absolute proton numbers. While CR-39 was placed in front of the image plate for lower energy protons, it was placed behind the image plate for energies above 10 MeV using suitable metal filters sandwiched between the image plate and CR-39 to select specific energies. The measured response agrees well with previously reported calibrations as well as standard models of IP response, providing, for the first time, an absolute calibration over a large range of proton energies of relevance to current experiments.

2.
Sci Rep ; 7(1): 2152, 2017 05 19.
Article in English | MEDLINE | ID: mdl-28526837

ABSTRACT

We present the characteristics of track formation on the front and rear surfaces of CR-39 produced by laser-driven protons and carbon ions. A methodological approach, based on bulk etch length, is proposed to uniquely characterize the particle tracks in CR-39, enabling comparative description of the track characteristics in different experiments. The response of CR-39 to ions is studied based on the energy dependent growth rate of the track diameter to understand the intrinsic particle stopping process within the material. A large non-uniformity in the track diameter is observed for CR-39 with thickness matching with the stopping range of particles. Simulation and experimental results show the imprint of longitudinal range straggling for energetic protons. Moreover, by exploiting the energy dependence of the track diameter, the energy resolution (δE/E) of CR-39 for few MeV protons and Carbon ion is found to be about 3%.

3.
Opt Express ; 24(24): 28104-28112, 2016 Nov 28.
Article in English | MEDLINE | ID: mdl-27906375

ABSTRACT

A significant level of back reflected laser energy was measured during the interaction of ultra-short, high contrast PW laser pulses with solid targets at 30° incidence. 2D PIC simulations carried out for the experimental conditions show that at the laser-target interface a dynamic regular structure is generated during the interaction, which acts as a grating (quasi-grating) and reflects back a significant amount of incident laser energy. With increasing laser intensity above 1018 W/cm2 the back reflected fraction increases due to the growth of the surface modulation to larger amplitudes. Above 1020 W/cm2 this increase results in the partial destruction of the quasi-grating structure and, hence, in the saturation of the back reflection efficiency. The PIC simulation results are in good agreement with the experimental findings, and, additionally, demonstrate that in presence of a small amount of pre-plasma this regular structure will be smeared out and the back reflection reduced.

4.
Rev Sci Instrum ; 87(8): 083301, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27587107

ABSTRACT

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

5.
Phys Rev Lett ; 109(18): 185006, 2012 Nov 02.
Article in English | MEDLINE | ID: mdl-23215290

ABSTRACT

The acceleration of ions from ultrathin foils has been investigated by using 250 TW, subpicosecond laser pulses, focused to intensities of up to 3 × 10(20) W cm(-2). The ion spectra show the appearance of narrow-band features for protons and carbon ions peaked at higher energies (in the 5-10 MeV/nucleon range) and with significantly higher flux than previously reported. The spectral features and their scaling with laser and target parameters provide evidence of a multispecies scenario of radiation pressure acceleration in the light sail mode, as confirmed by analytical estimates and 2D particle-in-cell simulations. The scaling indicates that monoenergetic peaks with more than 100 MeV/nucleon are obtainable with moderate improvements of the target and laser characteristics, which are within reach of ongoing technical developments.


Subject(s)
Lasers , Models, Theoretical , Carbon/chemistry , Computer Simulation , Protons , Thermodynamics
6.
Phys Med Biol ; 56(21): 6969-82, 2011 Nov 07.
Article in English | MEDLINE | ID: mdl-22008825

ABSTRACT

Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen's University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 109 Gy s−1 and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.


Subject(s)
Lasers , Protons , Radiobiology/methods , Radiometry/methods , Spectrum Analysis/methods , Algorithms , Animals , Cricetinae , Cricetulus , Fibroblasts/cytology , Fibroblasts/radiation effects , Radiation Dosage , Radiobiology/instrumentation , Radiobiology/standards , Radiometry/instrumentation , Radiometry/standards , Signal Processing, Computer-Assisted/instrumentation , Spectrum Analysis/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...