1.
J Forensic Sci ; 69(2): 669-677, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38263807

ABSTRACT

Latent fingerprints were successfully visualized using fluorescence lifetime imaging (FLIM) on paper which emits strong fluorescence with a lifetime close to that of fingerprints and thus from which it is difficult for time-resolved spectroscopy to visualize fingerprints. Latent fingerprint samples on paper were excited using a 450 nm or 532 nm nanosecond pulsed-laser, and time-resolved fluorescence images were obtained at a delay time of 6-16 ns in intervals of 1 ns, to the excitation pulse. The excitation beam was expanded using a lens, and the fluorescence from the fingerprints was captured using an intensified CCD camera. Because of the large fluorescence intensity of the background paper of approximately two to four orders of magnitude larger than that of the fingerprint, the fingerprint was not visualized on each fluorescence image by time-resolved spectroscopy. However, the fingerprint was visualized in a FLIM image constructed using a series of the fluorescence images for the case with the fluorescence intensity of the background paper being four orders of magnitude larger than that of the fingerprint. The difference in fluorescence lifetime in the FLIM image of the visualized fingerprint and background paper was in the order of 0.1 ns, which was an order of magnitude smaller than the inherent fluorescence lifetime of a few nanoseconds for the fingerprints and paper. It was demonstrated that, at a background fluorescence intensity with a certain order of magnitude larger than that of fingerprints, FLIM has the potential to visualize latent fingerprints which cannot be visualized by time-resolved spectroscopy.

2.
Forensic Sci Int ; 343: 111549, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36634431

ABSTRACT

Overlapping fingermark images are sometimes discarded because fingermark collation for the individual fingermarks is difficult. Fluorescence hyperspectral data (HSD) measured using the models of double overlapping fingermarks obtained under the excitation of a high-power, continuous wave, green laser is suitable for obtaining individual fingermark images. However, there are limitations such as the problems on each spectrum of the individual fingermark and the forensic value of the obtained images. In this study, independent component analysis (ICA) was applied to the fluorescence HSD obtained from the models of doubly overlapping fingermarks, to obtain independent component (IC) spectra and the corresponding IC images. Forensic value of the obtained IC images was examined, considering the possibility of fingermark collation in masked fashion to the model sample information. The IC images obtained from the HSD had enough potential to enable extracting twelve minutiae required for fingermark collation if the image quality was good.

3.
J Forensic Sci ; 67(3): 1208-1214, 2022 May.
Article in English | MEDLINE | ID: mdl-34985132

ABSTRACT

Overlapping fingerprints are often found at crime scenes, but only individual fingerprints separated from each other are admissible as evidence in court. Fingerprint components differ slightly among individuals, and thus their fluorescence spectra also differ from each other. Therefore, the separation of overlapping fingerprints using the difference of the fluorescence spectrum was performed with a hyperspectral imager. Hyperspectral data (HSD) of overlapping fingerprints were recorded under UV LED excitation. Principal component analysis (PCA) and multivariate curve resolution-alternating least squares (MCR-ALS) were applied to the HSD to determine the optimal method for obtaining high-contrast images of individual fingerprints. The results suggested that MCR-ALS combined with PCA-based initialization is capable of separating overlapping fingerprints into individual fingerprints. In this study, a method for separating overlapping fingerprints without initial parameters was proposed.


Subject(s)
Hyperspectral Imaging , Humans , Least-Squares Analysis , Multivariate Analysis , Principal Component Analysis
4.
Phys Rev Lett ; 104(24): 245002, 2010 Jun 18.
Article in English | MEDLINE | ID: mdl-20867308

ABSTRACT

We present an observation of beat oscillation generation by coupled modes associated with parametric decay instability (PDI) during radio frequency (rf) wave heating experiments on the Tokyo Spherical Tokamak-2. Nearly identical PDI spectra, which are characterized by the coexistence of the rf pump wave, the lower-sideband wave, and the low-frequency oscillation in the ion-cyclotron range of frequency, are observed at various locations in the edge plasma. A bispectral power analysis was used to experimentally discriminate beat oscillation from the resonant mode for the first time. The pump and lower-sideband waves have resonant mode components, while the low-frequency oscillation is exclusively excited by nonlinear coupling of the pump and lower-sideband waves. Newly discovered nonlocal transport channels in spectral space and in real space via PDI are described.