1.
Appl Opt ; 60(8): 2288-2303, 2021 Mar 10.
Article in English | MEDLINE | ID: mdl-33690328

ABSTRACT

The advanced radiographic capability (ARC) laser system, part of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory, is a short-pulse laser capability integrated into the NIF. The ARC is designed to provide adjustable pulse lengths of ∼1-38ps in four independent beamlets, each with energies up to 1 kJ (depending on pulse duration). A detailed model of the ARC lasers has been developed that predicts the time- and space-resolved focal spots on target for each shot. Measurements made to characterize static and dynamic wavefront characteristics of the ARC are important inputs to the code. Modeling has been validated with measurements of the time-integrated focal spot at the target chamber center (TCC) at low power, and the space-integrated pulse duration at high power, using currently available diagnostics. These simulations indicate that each of the four ARC beamlets achieves a peak intensity on target of up to a few 1018W/cm2.

2.
Appl Opt ; 58(31): 8501-8510, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31873335

ABSTRACT

We report on the design, performance, and qualification of the injection laser system designed to deliver joule-level chirped pulse beamlets arranged in dual rectangular beam formats into two main laser amplifier beamlines of the National Ignition Facility. The system is designed to meet the requirements of the Advanced Radiographic Capability upgrade with features that deliver performance, adjustability, and long-term reliability.

3.
Rev Sci Instrum ; 79(10): 10F546, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044688

ABSTRACT

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility. To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.