Opt Express ; 20(5): 5622-8, 2012 Feb 27.
Article in English | MEDLINE | ID: mdl-22418369

ABSTRACT

We characterize the performance of a quantum well infrared photodetector (QWIP), which is fabricated as a photonic crystal slab (PCS) resonator. The strongest resonance of the PCS is designed to coincide with the absorption peak frequency at 7.6 µm of the QWIP. To accurately characterize the detector performance, it is illuminated by using single mode mid-infrared lasers. The strong resonant absorption enhancement yields a detectivity increase of up to 20 times. This enhancement is a combined effect of increased responsivity and noise current reduction. With increasing temperature, we observe a red shift of the PCS-QWIP resonance peak of -0.055 cm(-1)/K. We attribute this effect to a refractive index change and present a model based on the revised plane wave method.


Subject(s)
Lasers , Photometry/instrumentation , Transducers , Equipment Design , Equipment Failure Analysis , Infrared Rays , Quantum Theory , Signal-To-Noise Ratio