JACC Clin Electrophysiol ; 10(7 Pt 2): 1689-1699, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39084743

ABSTRACT

BACKGROUND: Nonrandomized data suggest that longer diagnosis-to-ablation time (DAT) is associated with poorer outcomes; however, a recent randomized trial found no difference in recurrences when ablation was delayed by 12 months. OBJECTIVES: This study sought to assess the impact of DAT on atrial fibrillation (AF) recurrence in patients undergoing catheter ablation for persistent AF. METHODS: CAPLA (Effect of Catheter Ablation Using Pulmonary Vein Isolation With vs Without Posterior Left Atrial Wall Isolation on Atrial Arrhythmia Recurrence in Patients With Persistent Atrial Fibrillation: The CAPLA randomized clinical trial) was a multicenter trial that randomized patients with persistent AF to pulmonary vein isolation + posterior wall isolation or pulmonary vein isolation alone. Follow-up was 12 months. Outcomes were assessed after a 3-month blanking period. RESULTS: Median DAT in the 334 patients was 28 months (Q1-Q3: 12-66 months). Patients were divided into quartile groups: Q1 was DAT 0 to 12 months (n = 84, median DAT 7 months), Q2 was DAT 13 to 28 months (n = 85, median DAT 20 months), Q3 was DAT 29 to 66 months (n = 84, median DAT 41 months), and Q4 was DAT ≥67 months (n = 81, median DAT 119 months). AF recurrence rate was 36.9% for Q1, 44.7% for Q2, 47.6% for Q3, and 56.8% for Q4 (P = 0.082). On multivariable analysis, DAT Q4 was the only factor significantly associated with risk of recurrence (HR: 1.607; 95% CI: 1.005-2.570; P = 0.048). Median AF burden was 0% (Q1-Q3: 0%-0.47%) in Q1 and 0.33% (Q1-Q3: 0%-4.6%) in Q4 (P = 0.002). Quality of life (assessed by the Atrial Fibrillation Effect on Quality-of-Life questionnaire) improved markedly in all quartiles (Q1: Δ28.8 ± 24, Q2: Δ24.4 ± 23.4, Q3: Δ21.7 ± 26.6, Q4: Δ24.6 ± 21.4; P = 0.331). CONCLUSIONS: In a cohort of patients with persistent AF undergoing ablation in a prospective trial with standardized entry criteria and intensive electrocardiogram monitoring, those with shorter DAT had lower rates of AF recurrence. However, differences were modest, and all quartiles demonstrated very low AF burden and improvements in quality of life.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Male , Female , Middle Aged , Aged , Pulmonary Veins/surgery , Treatment Outcome , Time Factors , Time-to-Treatment/statistics & numerical data
2.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1711-1719, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39084745

ABSTRACT

BACKGROUND: Although postoperative atrial fibrillation (POAF) frequently occurs early after cardiac surgery, there is a paucity of data evaluating predictors and timing of late atrial fibrillation (AF) recurrence. OBJECTIVES: The authors sought to evaluate predictors of late AF recurrence in patients undergoing cardiac surgery. METHODS: We retrospectively reviewed cardiac surgery patients from 2010 to 2018 with no preoperative diagnosis of AF or atrial flutter. We recorded incidence and timing of late AF recurrence, defined as occurring ≥12 months following surgery. RESULTS: 1,031 patients were included (mean age at surgery 64 ± 12 years, 74% male). Early POAF was recorded in 445 patients (43%). POAF was usually transient, with total AF duration <48 hours in 72% and reversion to sinus rhythm at discharge in 91%. At 4.7 ± 2.4 years follow-up, late AF occurred in 139 patients (14%). Median time to AF recurrence was 4.4 years post-surgery (Q1-Q3: 2.6-6.2 years). Late AF was significantly more likely among patients with early POAF than those without (23% vs 6%; P < 0.001), with highest incidence (38%) in those with POAF duration >48 hours. In a multivariable analysis, early POAF duration >48 hours was a significant predictor of late AF recurrence (HR: 5.9). Surgery type and CHA2DS2-VASc score were not predictive of late AF events. CONCLUSIONS: Post-operative AF episodes of duration ≥48 hours predict recurrent AF episodes over long-term follow-up after cardiac surgery. Implications for arrhythmia surveillance and anticoagulation in patients with longer duration POAF episodes require further study.


Subject(s)
Atrial Fibrillation , Cardiac Surgical Procedures , Postoperative Complications , Recurrence , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Male , Female , Middle Aged , Cardiac Surgical Procedures/adverse effects , Retrospective Studies , Aged , Postoperative Complications/epidemiology , Risk Factors , Incidence , Time Factors
4.
J Electrocardiol ; 85: 50-57, 2024.
Article in English | MEDLINE | ID: mdl-38852223

ABSTRACT

BACKGROUND: Differentiation between ventricular tachycardia (VT) and supraventricular tachycardia (SVT) with aberrancy based on the 12­lead ECG alone can be imprecise. Implantable cardiac defibrillators (ICD) may be inserted for presumed VT, particularly in patients with syncopal presentation or atypical aberrancy patterns. Accurate diagnosis of these patients facilitated by an electrophysiology study (EPS) may alter diagnosis and management. METHODS: We present a prospective collection of cases across 3 cardiac centers of consecutive patients with WCT presumed to be VT who were referred for consideration of an ICD, and in whom further evaluation including an EPS ultimately demonstrated SVT with aberrancy as the culprit arrhythmia. RESULTS: 22 patients were identified (17 male, mean age 50±13 years. Available rhythm data at the time of referral was presumptively diagnosed as monomorphic VT in 16 patients and polymorphic VT in 6 patients. Underlying structural heart disease was present in 20 (91%). EPS resulted in a diagnosis of SVT with aberrancy in all cases: comprising AV nodal re-entry tachycardia (n=10), orthodromic reciprocating tachycardia (n=3), focal atrial tachycardia (n=3), AF/AFL (n=3) and 'double fire' tachycardia (n=2). 21 (95%) patients underwent successful ablation. All patients remained free of arrhythmia recurrence at a median of 3.4 years of follow-up. ICD insertion was obviated in 18 (82%) patients, with 1 patient proceeding to ICD extraction. CONCLUSION: SVT with atypical aberrancy may mimic monomorphic or polymorphic VT. Careful examination of all available rhythm data and consideration of an EPS can confirm SVT and obviate the need for ICD therapy.


Subject(s)
Electrocardiography , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular , Humans , Male , Middle Aged , Female , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Diagnosis, Differential , Prospective Studies , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology
5.
J Mol Cell Cardiol ; 193: 91-99, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38838814

ABSTRACT

Atrial fibrillation (AF), with its significant associated morbidity and mortality contributes to significant healthcare utilisation and expenditure. Given its progressively rising incidence, strategies to limit AF development and progression are urgently needed. Lifestyle modification is a potentially potent but underutilised weapon against the AF epidemic. The purpose of this article is to review the role of lifestyle factors as risk factors for AF, outline potential mechanisms of pathogenesis and examine the available evidence for lifestyle intervention in primary and secondary AF prevention. It will also highlight the need for investment by physicians, researchers, health services and governments in order to facilitate delivery of the comprehensive, multidisciplinary AF care that is required to manage this complex and multifactorial disease.


Subject(s)
Atrial Fibrillation , Life Style , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Atrial Fibrillation/therapy , Humans , Risk Factors
6.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38701222

ABSTRACT

AIMS: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS: The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION: The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Feasibility Studies , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Catheter Ablation/methods , Catheter Ablation/instrumentation , Aged , Equipment Design , Phrenic Nerve/injuries , Time Factors
7.
Eur Heart J ; 45(29): 2604-2616, 2024 Aug 03.
Article in English | MEDLINE | ID: mdl-38759110

ABSTRACT

BACKGROUND AND AIMS: Patterns of atrial fibrillation (AF) recurrence post-catheter ablation for persistent AF (PsAF) are not well described. This study aimed to describe the pattern of AF recurrence seen following catheter ablation for PsAF and the implications for healthcare utilization and quality of life (QoL). METHODS: This was a post-hoc analysis of the CAPLA study, an international, multicentre study that randomized patients with symptomatic PsAF to pulmonary vein isolation plus posterior wall isolation or pulmonary vein isolation alone. Patients underwent twice daily single lead ECG, implantable device monitoring or three monthly Holter monitoring. RESULTS: 154 of 333 (46.2%) patients (median age 67.3 years, 28% female) experienced AF recurrence at 12-month follow-up. Recurrence was paroxysmal in 97 (63%) patients and persistent in 57 (37%). Recurrence type did not differ between randomization groups (P = .508). Median AF burden was 27.4% in PsAF recurrence and .9% in paroxysmal AF (PAF) recurrence (P < .001). Patients with PsAF recurrence had lower baseline left ventricular ejection fraction (PsAF 50% vs. PAF 60%, P < .001) and larger left atrial volume (PsAF 54.2 ± 19.3 mL/m² vs. PAF 44.8 ± 11.6 mL/m², P = .008). Healthcare utilization was significantly higher in PsAF (45 patients [78.9%]) vs. PAF recurrence (45 patients [46.4%], P < .001) and lowest in those without recurrence (17 patients [9.5%], P < .001). Patients without AF recurrence had greater improvements in QoL as assessed by the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire (Δ33.3 ± 25.2 points) compared to those with PAF (Δ24.0 ± 25.0 points, P = .012) or PsAF (Δ13.4 ± 22.9 points, P < .001) recurrence. CONCLUSIONS: AF recurrence is more often paroxysmal after catheter ablation for PsAF irrespective of ablation strategy. Recurrent PsAF was associated with higher AF burden, increased healthcare utilization and antiarrhythmic drug use. The type of AF recurrence and AF burden may be considered important endpoints in clinical trials investigating ablation of PsAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Quality of Life , Recurrence , Humans , Atrial Fibrillation/surgery , Female , Male , Catheter Ablation/methods , Aged , Middle Aged , Pulmonary Veins/surgery , Electrocardiography, Ambulatory , Patient Acceptance of Health Care/statistics & numerical data , Treatment Outcome
8.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1313-1325, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38752958

ABSTRACT

BACKGROUND: Although the substrate in persistent atrial fibrillation (PeAF) is not limited to the pulmonary veins (PVs), PV isolation (PVI) remains the cornerstone ablation strategy. OBJECTIVES: The aim of this study was to describe the mechanism of outgoing wavefronts (WFs) originating in the PV sleeves during PeAF. METHODS: Eleven patients presenting for first-time PeAF ablation were recruited (mean age 63.1 ± 10.9 years, 91% men). A 64-electrode catheter (Constellation; 38 mm) was positioned within the PV under fluoroscopic guidance. An inverse mapping technique was used to reconstruct unipolar atrial electrograms on the PV surface, and the resulting phase maps were used to identify incoming and outgoing WFs at the PV junction and to classify focal and re-entrant activity within the PV sleeves. RESULTS: During PeAF, the PVs gave rise to outgoing WFs with a frequency of 3.7 s-1 (Q1-Q3: 3.4-5.4 s-1) compared with 3.6 s-1 (Q1-Q3: 2.8-4.2 s-1) for incoming WFs. Circuitous macroscopic re-entry was the dominant mechanism driving outgoing WFs (frequency of re-entry 2.7 s-1 [Q1-Q3: 2.0-3.3 s-1] compared with focal activity 1.4 s-1 [Q1-Q3: 1.1-1.5 s-1]; P < 0.006). This was initiated by incoming WFs in 80% of cases. Consecutive focal activation from the same location was infrequent (10.0% ± 6.6%, n = 10). Rotors ≥360° were never observed. The median ratio (R) of outgoing to incoming WF frequency was 1.14 (Q1-Q3: 0.84-1.75), with R > 1 in 6 of 11 PVs. CONCLUSIONS: Electric activity generated by PV sleeves during PeAF is due mainly to circuitous re-entry initiated by incoming waves, frequently with R > 1. That is, the PVs act less as drivers of atrial fibrillation than as "echo chambers" that sustain and amplify fibrillatory activity.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Middle Aged , Female , Male , Catheter Ablation/methods , Aged , Electrophysiologic Techniques, Cardiac/methods
9.
Heart Lung Circ ; 33(6): 828-881, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38702234

ABSTRACT

Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Australia , Cardiology/standards , Catheter Ablation/methods , Catheter Ablation/standards , New Zealand , Societies, Medical
10.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1620-1630, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38752960

ABSTRACT

BACKGROUND: Linear and complex electrogram ablation (LCEA) beyond pulmonary vein isolation (PVI) is associated with an increase in left atrial macro-re-entrant tachycardias (LAMTs). Posterior wall isolation (PWI) is increasingly performed to improve AF ablation outcomes. However, the impact of PWI on the incidence of LAMT is unknown. OBJECTIVES: The purpose of this study was to establish the incidence of LAMT following PVI alone vs PVI + PWI vs PVI + PWI + LCEA. METHODS: Consecutive patients undergoing catheter ablation for AF or LAMT post-AF ablation between 2008 and 2022 from 4 electrophysiology centers were reviewed with a minimum follow-up of 12 months. RESULTS: In total, 5,619 (4,419 index, 1,100 redo) AF ablation procedures were performed in 4,783 patients (mean age 60.9 ± 10.6 years, 70.7% men). Over a mean follow-up of 6.4 ± 3.8 years, 246 procedures for LAMT were performed in 214 patients at a mean of 2.6 ± 0.6 years post-AF ablation. Perimitral (52.8% of patients), roof-dependent (27.1%), PV gap-related (17.3%), and anterior circuits (8.9%) were most common, with 16.4% demonstrating multiple circuits. The incidence of LAMT was significantly higher following PVI + PWI (6.2%) vs PVI alone (3.0%; P < 0.0001) and following PVI + PWI + LCEA vs PVI + PWI (12.5%; P = 0.019). Conduction gaps in previous ablation lines were responsible for LAMT in 28.4% post-PVI alone, 35.3% post-PVI + PWI (P = 0.386), and 81.8% post-PVI + PWI + LCEA (P < 0.005). CONCLUSIONS: The incidence of LAMT following PVI + PWI is higher than with PVI alone but significantly lower than with more extensive atrial substrate modification. Given a low frequency of LAMT following PWI, empiric mitral isthmus ablation is not justified and may be proarrhythmic.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Humans , Catheter Ablation/methods , Catheter Ablation/adverse effects , Female , Male , Atrial Flutter/surgery , Atrial Flutter/epidemiology , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Incidence , Aged , Pulmonary Veins/surgery , Electrophysiologic Techniques, Cardiac , Retrospective Studies , Treatment Outcome
11.
Heart Rhythm ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38597857

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

12.
J Interv Card Electrophysiol ; 67(5): 921-1072, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Consensus , Societies, Medical , Atrial Fibrillation/surgery , Catheter Ablation/methods , Humans , Europe , Latin America , Asia
14.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
15.
Heart Rhythm ; 21(6): 762-770, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38336190

ABSTRACT

BACKGROUND: Sex-specific outcomes after catheter ablation (CA) for atrial fibrillation (AF) have reported conflicting findings. OBJECTIVE: We examined the impact of female sex on outcomes in patients with persistent AF (PsAF) from the Catheter Ablation for Persistent Atrial Fibrillation: A Multicentre Randomized Trial of Pulmonary Vein Isolation vs PVI with Posterior Left Atrial Wall Isolation (CAPLA) randomized trial. METHODS: A total of 338 patients with PsAF were randomized to pulmonary vein isolation (PVI) or PVI with posterior wall isolation (PWI). The primary outcome was arrhythmia recurrence at 12 months. Clinical and electroanatomical characteristics, arrhythmia recurrence, and quality of life were compared between women and men. RESULTS: Seventy-nine women (23.4%; PVI 37; PVI + PWI 42) and 259 men (76.6%; PVI 131; PVI + PWI 128) underwent AF ablation. Women were older {median age 70.4 (interquartile range [IQR] 64.8-74.6) years vs 64.0 (IQR 56.7-69.7) years; P < .001} and had more advanced left atrial electroanatomical remodeling. At 12 months, arrhythmia-free survival was lower in women (44.3% vs 56.8% in men; hazard ratio 1.44; 95% confidence interval 1.02-2.04; log-rank, P = .036). PWI did not improve arrhythmia-free survival at 12 months (hazard ratio 1.02; 95% confidence interval 0.74-1.40; log-rank, P = .711). The median AF burden was 0% in both groups (women: IQR 0.0%-2.2% vs men: IQR 0.0%-2.8%; P = .804). Health care utilization was comparable between women (36.7%) and men (30.1%) (P = .241); however, women were more likely to undergo a repeat procedure (17.7% vs 6.9%; P = .007). Women reported more severe baseline anxiety (average Hospital Anxiety and Depression Scale [HADS] anxiety score 7.5 ± 4.9 vs 6.3 ± 4.3 in men; P = .035) and AF-related symptoms (baseline Atrial Fibrillation Effect on Quality-of-Life Questionnaire [AFEQT] score 46.7 ± 20.7 vs 55.9 ± 23.0 in men; P = .002), with comparable improvements in psychological symptoms (change in HADS anxiety score -3.8 ± 4.6 vs -3.0 ± 4.5; P = .152 (change in HADS depression score -2.9 ± 5.0 vs -2.6 ± 4.0; P = .542) and greater improvement in AFEQT score compared with men at 12 months (change in AFEQT score +45.9 ± 23.1 vs +39.2 ± 24.8; P = .048). CONCLUSION: Women undergoing CA for PsAF report more significant symptoms and poorer quality of life at baseline than men. Despite higher arrhythmia recurrence and repeat procedures in women, the AF burden was comparably low, resulting in significant improvements in quality of life and psychological well-being after CA in both sexes.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Quality of Life , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Catheter Ablation/methods , Female , Male , Middle Aged , Aged , Sex Factors , Pulmonary Veins/surgery , Treatment Outcome , Recurrence , Heart Atria/physiopathology , Follow-Up Studies
16.
J Interv Card Electrophysiol ; 67(4): 887-900, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38289561

ABSTRACT

Ebstein's anomaly of the tricuspid valve (EA) is an uncommon congenital cardiac malformation. It can present with atrioventricular tachycardia (AVRT), atrioventricular nodal re-entrant tachycardia (AVNRT), atrial arrhythmias, and rarely with ventricular tachycardia. The 12-lead electrocardiogram (ECG) is critically important and often diagnostic even prior to an electrophysiology study (EPS). Due to its complex anatomy, it poses particular challenges for mapping and ablation, even for an experienced electrophysiologist. In this review, we aim to provide insight into the electrophysiological perspective of EA and an in-depth analysis of the various arrhythmias encountered in diverse clinical scenarios.


Subject(s)
Ebstein Anomaly , Electrocardiography , Ebstein Anomaly/surgery , Ebstein Anomaly/physiopathology , Ebstein Anomaly/diagnostic imaging , Humans , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac/methods , Catheter Ablation/methods , Female , Male , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/diagnosis
18.
JACC Clin Electrophysiol ; 10(3): 527-536, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38180432

ABSTRACT

BACKGROUND: Non-pulmonary vein (PV) triggers are increasingly targeted during atrial fibrillation (AF) ablation. P-wave morphology (PWM) can be useful because point mapping of AF triggers is challenging. The impact of prior ablation on PWM is yet to be determined. OBJECTIVES: This study sought to report PWM before and after left atrial (LA) ablation and construct a P-wave algorithm of common non-PV trigger locations. METHODS: This multicenter, prospective, observational study analyzed the paced PWM of 30 patients with persistent AF undergoing pulmonary vein isolation (PVI) and posterior wall isolation (PWI). Pace mapping was performed at the SVC, crista terminalis, inferior tricuspid annulus, coronary sinus ostium, left septum, left atrial appendage, Ligament of Marshall, and inferoposterior LA. The PWM was reported before PVI, then blinded comparisons were made post-PVI and post-PVI + PWI. A P-wave algorithm was constructed. RESULTS: A total of 8,352 paced P waves were prospectively recorded. No significant changes in the PWM were seen post-PVI alone in 2,775 of 2,784 (99.7%) and post-PWI in 2,715 of 2,784 (97.5%). Changes in PWM were predominantly at the IPLA (53 P waves) with a positive P-wave in leads V2 to V6 before biphasic post-PWI, LA appendage (9 P waves), coronary sinus ostium (6 P waves), and ligament of Marshall (3 P waves). A PWM algorithm was created before PVI and accurately predicted the location in 93% post-PVI + PWI. CONCLUSIONS: Minimal change was observed in PWM post-PV and PWI aside from the IPLA location. A P-wave algorithm created before and applied after PVI + PWI provided an accuracy of 93%. PWM provides a reliable tool to guide the localization of common non-PV trigger sites even after PV and PWI.


Subject(s)
Atrial Fibrillation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Prospective Studies , Treatment Outcome , Atrial Fibrillation/surgery , Heart Atria
19.
Circulation ; 149(18): 1405-1415, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38109351

ABSTRACT

BACKGROUND: Exercise-induced cardiac remodeling can be profound, resulting in clinical overlap with dilated cardiomyopathy, yet the significance of reduced ejection fraction (EF) in athletes is unclear. The aim is to assess the prevalence, clinical consequences, and genetic predisposition of reduced EF in athletes. METHODS: Young endurance athletes were recruited from elite training programs and underwent comprehensive cardiac phenotyping and genetic testing. Those with reduced EF using cardiac magnetic resonance imaging (defined as left ventricular EF <50%, or right ventricular EF <45%, or both) were compared with athletes with normal EF. A validated polygenic risk score for indexed left ventricular end-systolic volume (LVESVi-PRS), previously associated with dilated cardiomyopathy, was assessed. Clinical events were recorded over a mean of 4.4 years. RESULTS: Of the 281 elite endurance athletes (22±8 years, 79.7% male) undergoing comprehensive assessment, 44 of 281 (15.7%) had reduced left ventricular EF (N=12; 4.3%), right ventricular EF (N=14; 5.0%), or both (N=18; 6.4%). Reduced EF was associated with a higher burden of ventricular premature beats (13.6% versus 3.8% with >100 ventricular premature beats/24 h; P=0.008) and lower left ventricular global longitudinal strain (-17%±2% versus -19%±2%; P<0.001). Athletes with reduced EF had a higher mean LVESVi-PRS (0.57±0.13 versus 0.51±0.14; P=0.009) with athletes in the top decile of LVESVi-PRS having an 11-fold increase in the likelihood of reduced EF compared with those in the bottom decile (P=0.034). Male sex and higher LVESVi-PRS were the only significant predictors of reduced EF in a multivariate analysis that included age and fitness. During follow-up, no athletes developed symptomatic heart failure or arrhythmias. Two athletes died, 1 from trauma and 1 from sudden cardiac death, the latter having a reduced right ventricular EF and a LVESVi-PRS >95%. CONCLUSIONS: Reduced EF occurs in approximately 1 in 6 elite endurance athletes and is related to genetic predisposition in addition to exercise training. Genetic and imaging markers may help identify endurance athletes in whom scrutiny about long-term clinical outcomes may be appropriate. REGISTRATION: URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=374976&isReview=true; Unique identifier: ACTRN12618000716268.


Subject(s)
Athletes , Cardiomyopathy, Dilated , Stroke Volume , Humans , Male , Cardiomyopathy, Dilated/genetics , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/diagnostic imaging , Female , Adult , Young Adult , Physical Endurance/genetics , Adolescent , Genetic Predisposition to Disease , Ventricular Remodeling , Ventricular Function, Left
20.
JACC Clin Electrophysiol ; 10(2): 206-218, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38099880

ABSTRACT

BACKGROUND: Accurate annotation of electrogram local activation time (LAT) is critical to the functional assessment of ventricular tachycardia (VT) substrate. Contemporary methods of annotation include: 1) earliest bipolar electrogram (LATearliest); 2) peak bipolar electrogram (LATpeak); 3) latest bipolar electrogram (LATlatest); and 4) steepest unipolar -dV/dt (LAT-dV/dt). However, no direct comparison of these methods has been performed in a large dataset, and it is unclear which provides the optimal functional analysis of the VT substrate. OBJECTIVES: This study sought to investigate the optimal method of LAT annotation during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined critical site for VT re-entry were included. All electrograms were annotated using 5 different methods: LATearliest, LATpeak, LATlatest, LAT-dV/dt, and the novel steepest unipolar -dV/dt using a dynamic window of interest (LATDWOI). Electrograms were also tagged as either late potentials and/or fractionated signals. Maps, utilizing each annotation method, were then compared in their ability to identify critical sites using deceleration zones. RESULTS: Fifty cases were identified with 1,.813 ± 811 points per map. Using LATlatest, a deceleration zone was present at the critical site in 100% of cases. There was no significant difference with LATearliest (100%) or LATpeak (100%). However, this number decreased to 54% using LAT-dV/dt and 76% for LATDWOI. Using LAT-dV/dt, only 33% of late potentials were correctly annotated, with the larger far field signals often annotated preferentially. CONCLUSIONS: Annotation with LAT-dV/dt and LATDWOI are suboptimal in VT substrate mapping. We propose that LATlatest should be the gold standard annotation method, as this allows identification of critical sites and is most suited to automation.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac , Electrocardiography/methods
SELECTION OF CITATIONS