Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Circ Cardiovasc Interv ; 10(7)2017 Jul.
Article in English | MEDLINE | ID: mdl-28701488

ABSTRACT

BACKGROUND: Mechanical strength of bioresorbable scaffolds (BRS) is highly dependent on strut dimensions and polymer features. To date, the successful development of thin-walled BRS has been challenging. We compared the biomechanical behavior and vascular healing profile of a novel thin-walled (115 µm) sirolimus-eluting ultrahigh molecular weight amorphous poly-l-lactic acid-based BRS (APTITUDE, Amaranth Medical [AMA]) to Absorb (bioresorbable vascular scaffold [BVS]) using different experimental models. METHODS AND RESULTS: In vitro biomechanical testing showed no fractures in the AMA-BRS when overexpanded 1.3 mm above nominal dilatation values (≈48%) and lower number of fractures on accelerated cycle testing over time (at 21 K cycles=20.0 [19.5-20.5] in BVS versus 4.0 [3.0-4.3] in AMA-BRS). In the healing response study, 35 AMA-BRS and 23 BVS were implanted in 58 coronary arteries of 23 swine and followed-up to 180 days. Scaffold strut healing was evaluated in vivo using weekly optical coherence tomography analysis. At 14 days, the AMA-BRS demonstrated a higher percentage of embedded struts (71.0% [47.6, 89.1] compared with BVS 40.3% [20.5, 63.2]; P=0.01). At 21 days, uncovered struts were still present in the BVS group (3.8% [2.1, 10.2]). Histopathology revealed lower area stenosis (AMA-BRS, 21.0±6.1% versus BVS 31.0±4.5%; P=0.002) in the AMA-BRS at 28 days. Neointimal thickness and inflammatory scores were comparable between both devices at 180 days. CONCLUSIONS: A new generation thinned wall BRS displayed a more favorable biomechanical behavior and strut healing profile compared with BVS in normal porcine coronary arteries. This novel BRS concept has the potential to improve the clinical outcomes of current generation BRS.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Vessels/pathology , Percutaneous Coronary Intervention/instrumentation , Polyesters/chemistry , Sirolimus/administration & dosage , Wound Healing , Animals , Biopsy , Coronary Angiography , Coronary Vessels/drug effects , Coronary Vessels/physiopathology , Materials Testing , Models, Animal , Molecular Weight , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Prosthesis Failure , Sus scrofa , Time Factors , Tomography, Optical Coherence
2.
EuroIntervention ; 12(12): 1510-1518, 2016 12 20.
Article in English | MEDLINE | ID: mdl-27998842

ABSTRACT

AIMS: The vascular healing profile of polymers used in bioresorbable vascular scaffolds (BRS) has not been fully characterised in the absence of antiproliferative drugs. In this study, we aimed to compare the polymer biocompatibility profile and vascular healing response of a novel ultrahigh molecular weight amorphous PLLA BRS (FORTITUDE®; Amaranth Medical, Mountain View, CA, USA) against bare metal stent (BMS) controls in porcine coronary arteries. METHODS AND RESULTS: Following device implantation, optical coherence tomography (OCT) evaluation was performed at 0 and 28 days, and at one, two, three and four years. A second group of animals underwent histomorphometric evaluation at 28 and 90 days. At four years, both lumen (BRS 13.19±1.50 mm2 vs. BMS 7.69±2.41 mm2) and scaffold areas (BRS 15.62±1.95 mm2 vs. BMS 8.65±2.37 mm2) were significantly greater for BRS than BMS controls. The degree of neointimal proliferation was comparable between groups. Histology up to 90 days showed comparable healing and inflammation profiles for both devices. CONCLUSIONS: At four years, the novel PLLA BRS elicited a vascular healing response comparable to BMS in healthy pigs. Expansive vascular remodelling was evident only in the BRS group, a biological phenomenon that appears to be independent of the presence of antiproliferative drugs.


Subject(s)
Absorbable Implants , Coronary Vessels/surgery , Drug-Eluting Stents , Neointima/pathology , Polymers , Absorbable Implants/adverse effects , Animals , Coronary Angiography/methods , Coronary Vessels/pathology , Drug-Eluting Stents/adverse effects , Models, Animal , Molecular Weight , Polymers/adverse effects , Swine , Tomography, Optical Coherence/methods
3.
EuroIntervention ; 12(9): 1164-1173, 2016 Oct 20.
Article in English | MEDLINE | ID: mdl-27753601

ABSTRACT

AIMS: The aim of this study was to evaluate the biological efficacy of a novel lower-dose (2.5 µg/mm2) encapsulated paclitaxel nanocrystal-coated balloon (Nano-PCB) in the familial hypercholesterolaemic swine (FHS) model of iliofemoral in-stent restenosis. METHODS AND RESULTS: Nano-PCB pharmacokinetics were assessed in 20 femoral arteries (domestic swine). Biological efficacy was evaluated in ten FHS: 14 days following bare metal stent implantation each stent segment was randomised to a clinically available PCB (IN.PACT, n=14), the Nano-PCB (n=14) or an uncoated balloon (n=12). Angiographic, optical coherence tomography and histological evaluation was performed at 28 days after treatment. Arterial paclitaxel concentration was 120.7 ng/mg at one hour and 7.65 ng/mg of tissue at 28 days with the Nano-PCB. Compared to the control uncoated group, both PCBs significantly reduced percent area stenosis (Nano-PCB: 36.0±14.2%, IN.PACT: 29.3±9.2% vs control: 67.9±15.1%, p<0.001). Neointimal distribution in the entire stent length was more homogenous in the Nano-PCB. Histological evaluation showed comparable degrees of neointimal proliferation in both PCBs; however, the Nano-PCB showed slightly higher levels of neointimal maturity and endothelialisation. CONCLUSIONS: Lower-dose encapsulated paclitaxel nanocrystals delivered via a coated balloon displayed comparable biological efficacy with superior healing features compared to a clinically validated PCB technology.


Subject(s)
Antineoplastic Agents/pharmacology , Femoral Artery/drug effects , Graft Occlusion, Vascular , Hyperlipoproteinemia Type II , Iliac Artery/drug effects , Paclitaxel/pharmacology , Stents , Wound Healing/drug effects , Angiography , Angioplasty, Balloon, Coronary/instrumentation , Animals , Antineoplastic Agents/administration & dosage , Disease Models, Animal , Femoral Artery/diagnostic imaging , Femoral Artery/pathology , Femoral Artery/surgery , Iliac Artery/diagnostic imaging , Iliac Artery/pathology , Iliac Artery/surgery , Metals , Nanoparticles/administration & dosage , Neointima , Paclitaxel/administration & dosage , Peripheral Vascular Diseases , Sus scrofa , Swine , Tomography, Optical Coherence
4.
Circ Cardiovasc Interv ; 9(10)2016 10.
Article in English | MEDLINE | ID: mdl-27694138

ABSTRACT

BACKGROUND: Clinically available bioresorbable scaffolds (BRS) rely on polymer crystallinity to achieve mechanical strength resulting in limited overexpansion capabilities and structural integrity when exposed to high-loading conditions. We aimed to evaluate the biomechanical behavior and vascular healing profile of a novel, sirolimus-eluting, high-molecular-weight, amorphous poly-l-lactic acid-based BRS (Amaranth BRS). METHODS AND RESULTS: In vitro biomechanical testing was performed under static and cyclic conditions. A total of 99 devices (65 Amaranth BRS versus 34 Absorb bioresorbable vascular scaffold [BVS]) were implanted in 99 coronary arteries of 37 swine for pharmacokinetics and healing evaluation at various time points. In the Absorb BVS, the number of fractures per scaffold seen on light microscopy was 6.0 (5.0-10.5) when overexpanded 1.0 mm above nominal values (≈34%). No fractures were observed in the Amaranth BRS group at 1.3 mm above nominal values (≈48% overexpansion). The number of fractures was higher in the Absorb BVS on accelerated cycle testing over time (at 24K cycles=5.0 [5.0-9.0] Absorb BVS versus 0.0 [0.0-0.5] Amaranth BRS). Approximately 90% of sirolimus was found to be eluted by 90 days. Optical coherence tomography analysis demonstrated lower percentages of late scaffold recoil in the Amaranth BRS at 3 months (Amaranth BRS=-10±16.1% versus Absorb BVS=10.7±13.2%; P=0.004). Histopathology analysis revealed comparable levels of vascular healing and inflammatory responses between both BRSs up to 6 months. CONCLUSIONS: New-generation high-molecular-weight amorphous poly-l-lactic acid scaffolds have the potential to improve the clinical performance of BRS and provide the ideal platform for the future miniaturization of the technology.


Subject(s)
Absorbable Implants , Cardiovascular Agents/pharmacokinetics , Coated Materials, Biocompatible , Coronary Vessels/drug effects , Percutaneous Coronary Intervention/instrumentation , Polyesters/chemistry , Sirolimus/pharmacokinetics , Wound Healing/drug effects , Animals , Biopsy , Cardiovascular Agents/administration & dosage , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Materials Testing , Models, Animal , Molecular Weight , Neointima , Percutaneous Coronary Intervention/adverse effects , Prosthesis Failure , Sirolimus/administration & dosage , Swine , Swine, Miniature , Tomography, Optical Coherence
5.
EuroIntervention ; 12(6): 740-7, 2016 08 20.
Article in English | MEDLINE | ID: mdl-26428893

ABSTRACT

AIMS: Among antirestenotic compounds, sirolimus displays a superior safety profile compared to paclitaxel, but its pharmacokinetic properties make it a challenging therapeutic candidate for single-time delivery. Herein we evaluate the feasibility of delivery, long-term retention and vascular effects of sirolimus nanoparticles delivered through a novel porous angioplasty balloon in normal porcine arteries and in a swine model of in-stent restenosis (ISR). METHODS AND RESULTS: Sirolimus nanoparticle formulation was delivered via porous balloon angioplasty to 753 coronary artery segments for pharmacokinetic studies and 26 segments for biological effect of sirolimus delivery in different clinical scenarios (de novo [n=8], ISR [n=6] and following stent implantation [n=12]). Sirolimus coronary artery concentrations were above the target therapeutic level of 1 ng/mg after 26 days, and were >100-fold higher in coronary artery treatment sites than in distal myocardium and remote tissues at all time points. At 28 days, reduction in percent stenosis in formulation-treated sites compared to balloon angioplasty treatment was noted in all three clinical scenarios, with the largest effect seen in the de novo study. CONCLUSIONS: Local coronary delivery of sirolimus nanoparticles in the porcine model using a novel porous balloon delivery system achieved therapeutic long-term intra-arterial drug levels without significant systemic residual exposure.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Antibiotics, Antineoplastic/administration & dosage , Coronary Restenosis/prevention & control , Sirolimus/administration & dosage , Animals , Antibiotics, Antineoplastic/pharmacokinetics , Coronary Vessels/drug effects , Female , Male , Nanoparticles , Sirolimus/pharmacokinetics , Swine
6.
JACC Cardiovasc Interv ; 8(8): 1115-1123, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26117470

ABSTRACT

OBJECTIVES: This study sought to compare the effect of paclitaxel-coated balloon (PCB) concentration on tissue levels and vascular healing using 3 different PCB technologies (In.Pact Pacific = 3 µg/mm(2), Lutonix = 2 µg/mm(2) and Ranger = 2 µg/mm(2)) in the experimental setting. BACKGROUND: The optimal therapeutic dose for PCB use has not been determined yet. METHODS: Paclitaxel tissue levels were measured up to 60 days following PCB inflation (Ranger and In.Pact Pacific) in the superficial femoral artery of healthy swine (18 swine, 36 vessels). The familial hypercholesterolemic swine model of superficial femoral artery in-stent restenosis (6 swine, 24 vessels) was used in the efficacy study. Two weeks following bare-metal stent implantation, each in-stent restenosis site was randomly treated with a PCB or an uncoated control balloon (Sterling). Quantitative vascular analysis and histology evaluation was performed 28 days following PCB treatment. RESULTS: All PCB technologies displayed comparable paclitaxel tissue levels 4 h following balloon inflation. At 28 days, all PCB had achieved therapeutic tissue levels; however, the In.Pact PCB resulted in higher tissue concentrations than did the other PCB groups at all time points. Neointimal inhibition by histology was decreased in all PCB groups compared with the control group, with a greater decrease in the In.Pact group. However, the neointima was more mature and contained less peri-strut fibrin deposits in both 2-µg/mm(2) PCB groups. CONCLUSIONS: Compared with the clinically established PCB dose, lower-dose PCB technologies achieve lower long-term tissue levels but comparable degrees of neointimal inhibition and fewer fibrin deposits. The impact of these findings in restenosis reduction and clinical outcomes needs to be further investigated.


Subject(s)
Cardiovascular Agents/pharmacokinetics , Coated Materials, Biocompatible , Endovascular Procedures/instrumentation , Femoral Artery/drug effects , Hyperlipoproteinemia Type II/complications , Paclitaxel/pharmacokinetics , Peripheral Arterial Disease/therapy , Stents , Vascular Access Devices , Wound Healing/drug effects , Animals , Cardiovascular Agents/administration & dosage , Constriction, Pathologic , Disease Models, Animal , Endovascular Procedures/adverse effects , Femoral Artery/diagnostic imaging , Femoral Artery/metabolism , Femoral Artery/pathology , Fibrin/metabolism , Metals , Neointima , Paclitaxel/administration & dosage , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/etiology , Peripheral Arterial Disease/metabolism , Radiography , Swine , Tissue Distribution
7.
EuroIntervention ; 10(12): 1480-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25912393

ABSTRACT

AIMS: To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. METHODS AND RESULTS: Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). CONCLUSIONS: TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.


Subject(s)
Cardiac Catheterization/methods , Heart Aneurysm/surgery , Heart Failure/surgery , Heart Ventricles/surgery , Plastic Surgery Procedures/methods , Thoracoscopy/methods , Ventricular Function, Left , Animals , Anterior Wall Myocardial Infarction/complications , Disease Models, Animal , Feasibility Studies , Heart Aneurysm/etiology , Heart Failure/etiology , Sheep , Treatment Outcome
8.
Int J Cardiovasc Imaging ; 31(6): 1097-106, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25922149

ABSTRACT

Intracoronary optical frequency domain imaging (OFDI), requires the displacement of blood for clear visualization of the artery wall. Radiographic contrast agents are highly effective at displacing blood however, may increase the risk of contrast-induced nephropathy. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. The aim of this work was to determine the optimal flushing parameters necessary to reliably perform intracoronary OFDI while reducing the volume of administered radiographic contrast, and assess the influence of flushing media choice on vessel wall measurements. 144 OFDI pullbacks were acquired together with synchronized EKG and intracoronary pressure wire recordings in three swine. OFDI images were graded on diagnostic quality and quantitative comparisons of flushing efficiency and intracoronary cross-sectional area with and without precise refractive index calibration were performed. Flushing media with higher viscosities resulted in rapid and efficient blood displacement. Media with lower viscosities resulted in increased blood-media transition zones, reducing the pullback length of diagnostic quality images obtained. Flushing efficiency was found to increase with increases in flow rate and duration. Calculations of lumen area using different flushing media were significantly different, varying up to 23% (p < 0.0001). This error was eliminated with careful refractive index calibration. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. For patients with sensitivity to contrast, to reduce the risk of contrast induced nephrotoxicity we recommend that intracoronary OFDI be conducted with flushing solutions containing little or no radiographic contrast. In addition, our findings show that careful refractive index compensation should be performed, taking into account the specific contrast agent used, in order to obtain accurate intravascular OFDI measurements.


Subject(s)
Cardiac Catheterization , Contrast Media/administration & dosage , Coronary Vessels/pathology , Therapeutic Irrigation/methods , Tomography, Optical Coherence , Animals , Coronary Circulation , Coronary Vessels/physiopathology , Electrocardiography , Female , Models, Animal , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Reproducibility of Results , Stents , Swine , Time Factors , Viscosity
10.
Catheter Cardiovasc Interv ; 86(1): 173-81, 2015 Jul.
Article in English | MEDLINE | ID: mdl-24130158

ABSTRACT

OBJECTIVES: Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model BACKGROUND: LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients METHODS: Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation RESULTS: Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder CONCLUSION: The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/instrumentation , Stroke/prevention & control , Sutures , Animals , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Cardiac Catheterization , Disease Models, Animal , Dogs , Echocardiography, Transesophageal , Fluoroscopy , Ligation/instrumentation , Stroke/etiology
11.
Catheter Cardiovasc Interv ; 83(3): 397-404, 2014 Feb 15.
Article in English | MEDLINE | ID: mdl-25295313

ABSTRACT

Background: Self-expanding stents (SES) are reemerging as therapeutic alternatives to treat coronary artery disease. It has been proposed that SES can improve clinical outcomes by inducing less injury at implantation and achieving better vessel wall apposition.To date, little data exists comparing the vascular response to both methods of deployment in a controlled experimental setting. Objective: To quantify differences in vascular injury and healing between second-generation SES and balloon-expandable stents (BES) and the effects of balloon post-dilatation in a porcine coronary model. Methods: Seventy-five bare SES (AXXESS or vProtect) and 42 BES (Vision) were implanted in porcine coronaries. A subset of these received balloon post-dilatation(SES 1 D 5 22, BES 1 D 5 20). Follow-up was scheduled at 30 (BES 5 10, BES 1 D 56, SES 5 19, SES 1 D 5 8), 90 (BES 5 6, BES 1 D 5 8, SES 5 19, SES 1 D 5 8), and 180 days (BES 5 6, BES 1 D 5 6, SES 5 15, SES 1 D 5 6). Results: In vivo imaging and histological analysis showed that neointimal formation peaks early (30 days) in BES. Conversely, for SES, the peak occurred later (90 days). However, the neointimal formation achieved in either group equalized at 180 days. For SES, post-dilatation shortened the peak of neointimal formation to 30 days. Conversely, for BES, post-dilatation delayed the peak of neointimal formation to 90 days. At 30 days, histology showed that SES had significantly less injury. However, at 90 days, injury scores tended to be higher for SES. By 180 days, injury scores were comparable between both groups. Conclusions: The mechanism of stent expansion influences the degree of vascular injury and healing. The synergistic use of balloon post dilatation changes the dynamics of healing and may impact the potential beneficial effects inherent to SES technologies.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/surgery , Stents , Tunica Intima/physiopathology , Vascular System Injuries/prevention & control , Wound Healing , Angioplasty, Balloon, Coronary/methods , Animals , Coronary Artery Disease/pathology , Coronary Artery Disease/physiopathology , Disease Models, Animal , Equipment Design , Injury Severity Score , Stents/adverse effects , Stents/standards , Swine , Time Factors , Tunica Intima/injuries , Vascular Patency , Vascular System Injuries/etiology
12.
EuroIntervention ; 10(8): 1002-8, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25308298

ABSTRACT

AIMS: The efficacy of paclitaxel-coated balloons (PCB) for the treatment of superficial femoral artery (SFA) disease has been demonstrated in the clinical setting. Due to the high frequency of arterial calcification found in this vascular territory, the adjunctive use of atherectomy plus PCB has been proposed. In this study, we aimed to evaluate the biological effect on vascular healing and drug retention of this combination approach in the familial hypercholesterolaemic swine (FHS) model of femoral artery stenosis. METHODS AND RESULTS: Eleven femoral arteries (six superficial and five profunda arteries) were included. Vessels were injured (x2) over a 28-day period and all animals were maintained on a high cholesterol diet for 60 days following initial injury. Vessels were randomised to PCB (n=5) or orbital atherectomy system (OAS) plus PCB (n=6). At 28 days following therapy, vessels were followed with angiography, intravascular ultrasound (IVUS) and optical coherence tomography (OCT). Vessels were harvested for histological and pharmacokinetic analysis. Angiographic findings were comparable at termination between both groups. The OCT findings were comparable at termination. There were no differences in the vascular healing profile between both groups. The paclitaxel levels at termination were comparable between both groups (PCB=5.16 vs. OAS+PCB=3.03 ng/mg). CONCLUSIONS: In the experimental setting, the combination of OAS+PCB appears to be safe by demonstrating a vascular healing profile and drug tissue levels comparable to PCB only. The vascular effect of PCB may be enhanced by the use of OAS by decreasing plaque burden and cholesterol crystals.


Subject(s)
Angioplasty, Balloon/methods , Antineoplastic Agents, Phytogenic/pharmacokinetics , Atherectomy/methods , Femoral Artery/surgery , Paclitaxel/pharmacokinetics , Peripheral Arterial Disease/surgery , Wound Healing/drug effects , Animals , Antineoplastic Agents, Phytogenic/pharmacology , Combined Modality Therapy , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Disease Models, Animal , Femoral Artery/diagnostic imaging , Femoral Artery/drug effects , Hyperlipoproteinemia Type II/complications , Paclitaxel/pharmacology , Peripheral Arterial Disease/etiology , Swine , Tomography, Optical Coherence , Ultrasonography, Interventional
13.
Open Heart ; 1(1): e000117, 2014.
Article in English | MEDLINE | ID: mdl-25332821

ABSTRACT

BACKGROUND: The efficacy of paclitaxel-coated balloons (PCB) for restenosis prevention has been demonstrated in humans. However, the mechanism of action for sustained drug retention and biological efficacy following single-time drug delivery is still unknown. METHODS AND RESULTS: The pharmacokinetic profile and differences in drug concentration (vessel surface vs arterial wall) of two different paclitaxel coating formulations (3 µg/mm(2)) displaying opposite solubility characteristics (CC=crystalline vs AC=amorphous) were tested in vivo and compared with paclitaxel-eluting stents (PES). Also, the biological effect of both PCB formulations on vascular healing was tested in the porcine coronary injury model. One hour following balloon inflation, both formulations achieved similar arterial paclitaxel levels (CC=310 vs AC=245 ng/mg; p=NS). At 24 h, the CC maintained similar tissue concentrations, whereas the AC tissue levels declined by 99% (p<0.01). At this time point, arterial levels were 20-fold (CC) and 5-fold (AC) times higher compared to the PES group (p<0.05). At 28 days, arterial levels retained were 9.2% (CC) and 0.04% (AC, p<0.01) of the baseline levels. Paclitaxel concentration on the vessel surface was higher in the CC at 1 (CC=36.7% vs AC=13.1%, p<0.05) and 7 days (CC=38.4% vs AC=11%, p<0.05). In addition, the CC induced higher levels of neointimal inhibition, fibrin deposition and delayed healing compared with the AC group. CONCLUSIONS: The presence of paclitaxel deposits on the vessel surface driving diffusion into the arterial tissue in a time-dependent fashion supports the mechanism of action of PCB. This specific pharmacokinetic behaviour influences the patterns of neointimal formation and healing.

14.
Coron Artery Dis ; 25(7): 595-601, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25013949

ABSTRACT

BACKGROUND: Peri-strut low-intensity area (PLI) is a common imaging finding during the evaluation of in-stent neointima using optical coherence tomography (OCT). We aimed to determine the biological significance of PLI by comparing in-vivo OCT images with the corresponding histological sections obtained from the familial hypercholesterolemic swine model of coronary stenosis. METHODS: A total of 26 coronary vessels of nine familial hypercholesterolemic swine were injured with 30% balloon overstretch and then immediately followed by everolimus eluting or bare metal stent placement at 20% overstretch. At 30 days, all stented vessels were subjected to in-vivo OCT analysis and were harvested for histological evaluation. For OCT analysis, stent cross-sections (three per stent) were categorized into presence (PLI+) or absence (PLI-) of PLI. In histology, inflammation and fibrin deposition were scored semiquantitatively from 0 (none) to 3 (severe). RESULTS: PLI was found in 64.9% of stent sections. Peri-strut inflammation was more frequently observed in OCT sections PLI (+) compared with PLI (-) (56.0 vs. 7.4%, P=0.01). In contrast, peri-strut fibrin deposits was similar in both groups (PLI+=58.0% vs. PLI-=59.3%, P=0.94). Histological neointimal thickness was significantly higher in PLI (+) sections (mean±SE: 0.68±0.06 vs. 0.34±0.02 mm; P<0.01), yielding a higher percent area stenosis compared with PLI (-) (mean±SE: 59.0±4.4 vs. 34.1±2.2%, P<0.01). The PLI diagnostic sensitivity and specificity for inflammation were 80 and 76.1%, respectively (>56% PLI, area under the curve=0.86, P<0.01), whereas for fibrin deposition, the sensitivity and specificity were 42.2 and 76.1%, respectively (area under the curve=0.56, P=NS). Area under the receiver operating characteristic curve was significantly higher for identifying inflammation than fibrin (0.86 vs. 0.56, P<0.01). The severity of PLI correlated with the neointimal thickness when assessed by OCT (R=0.79, P<0.001). CONCLUSION: The presence of PLI in OCT correlates with neointimal thickness and appears to have a diagnostic value in the recognition of peri-strut inflammation, therefore possibly serving as a surrogate for in-vivo assessment of stent efficacy.


Subject(s)
Coronary Artery Disease , Coronary Restenosis/pathology , Coronary Vessels/pathology , Graft Occlusion, Vascular/pathology , Hyperlipoproteinemia Type II , Inflammation/pathology , Neointima/pathology , Tomography, Optical Coherence , Animals , Coronary Restenosis/metabolism , Coronary Vessels/metabolism , Disease Models, Animal , Drug-Eluting Stents , Fibrin/metabolism , Graft Occlusion, Vascular/metabolism , Hyperplasia , Inflammation/metabolism , Male , Neointima/metabolism , Stents , Swine
15.
Coron Artery Dis ; 25(3): 198-207, 2014 May.
Article in English | MEDLINE | ID: mdl-24642807

ABSTRACT

BACKGROUND: The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS. METHODS: A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology. RESULTS: At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group. CONCLUSION: The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower levels of inflammation and slightly higher fibrin deposits compared with BMS controls.


Subject(s)
Coronary Vessels/pathology , Disease Models, Animal , Drug-Eluting Stents , Hyperlipoproteinemia Type II , Neointima , Sirolimus/analogs & derivatives , Animals , Blood Vessel Prosthesis Implantation/methods , Coronary Angiography/methods , Drug-Eluting Stents/adverse effects , Drug-Eluting Stents/standards , Everolimus , Humans , Hyperlipoproteinemia Type II/diagnosis , Hyperlipoproteinemia Type II/therapy , Immunosuppressive Agents/pharmacology , Male , Models, Cardiovascular , Neointima/diagnosis , Neointima/etiology , Polymers/pharmacology , Sirolimus/pharmacology , Swine , Tomography, Optical Coherence/methods , Treatment Outcome , Ultrasonography, Interventional/methods
16.
Eur Heart J Cardiovasc Imaging ; 15(3): 292-8, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24022066

ABSTRACT

AIMS: Although optical coherence tomography (OCT) is capable to detect microscopic peri-strut changes that seem to be related to neointimal inhibition and healing, its ability to characterize these components is still limited. In this study, we aimed to compare different OCT morphological characteristics with different in-stent neointimal tissue types analysed by histology. METHODS: A total of 69 stents (39 drug eluting and 30 bare metal stents) were implanted in coronary arteries of 27 swine. By OCT, neointimal type was classified as homogeneous, heterogeneous, or layered according to its pattern of backscatter and optical intensity. The resulting optical patterns were correlated with several histological findings [external elastic lamina (EEL) disruption, fibrin deposition, circumferential rim of peri-strut inflammatory cell infiltration, and fibrous connective deposition] in every single cross-section (CS) analysed. RESULTS: A total of 197 matched OCT and histological CS were analysed. The heterogeneous (0.44 ± 0.21 mm) and layered (0.65 ± 0.16 mm) patterns had a significantly higher degree of neointimal thickness compared with the homogeneous pattern (0.25 ± 0.16 mm, P < 0.001). Fibrous connective tissue deposition was more frequently present in the homogeneous pattern (71.6%, P < 0.001), whereas significant fibrin deposits were more commonly seen in the heterogeneous pattern (56.9%, P = 0.007). Peri-strut inflammation was less frequently found in the homogeneous pattern (19.8%, P < 0.001) in comparison with the layered (73.9%) or heterogeneous patterns (43.1%). The presence of EEL rupture was also more commonly seen in layered (73.9%) and heterogeneous (46.6%) patterns than in the homogeneous pattern (22.4%, P < 0.001). CONCLUSION: The optical characteristics of neointimal formation seen in OCT properly correlated with the presence of several histological findings involved in stent healing. The biological implications of these findings in clinical outcomes require further investigation.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Restenosis/pathology , Neointima/pathology , Stents , Tomography, Optical Coherence/methods , Angioplasty, Balloon, Coronary/adverse effects , Animals , Biopsy, Needle , Cell Proliferation , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Disease Models, Animal , Drug-Eluting Stents , Female , Immunohistochemistry , Male , Metals , Neointima/diagnostic imaging , Random Allocation , Swine , Treatment Outcome
17.
J Thorac Cardiovasc Surg ; 148(1): 225-31, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24084284

ABSTRACT

OBJECTIVE: The loss of normal apical rotation is associated with left ventricular (LV) remodeling and systolic dysfunction in patients with congestive heart failure after myocardial infarction. The objective of the present study was to evaluate the effect of epicardial ventricular reconstruction, an off-pump, less-invasive surgical reshaping technique, on myocardial strain, LV twist, and the potential alteration of myocardial fiber orientation in an ovine model of LV anteroapical aneurysm. METHODS: LV anteroapical myocardial infarction was induced by coil embolization of the left anterior descending artery. Eight weeks after occlusion, epicardial ventricular reconstruction was performed using left thoracotomy under fluoroscopic guidance in 8 sheep to completely exclude the scar. The peak systolic longitudinal/circumferential strains and LV twist were evaluated using speckle tracking echocardiography before (baseline), after device implantation, and at 6 weeks of follow-up. RESULTS: Epicardial ventricular reconstruction was completed in all sheep without any complications. Immediately after device implantation, LV twist significantly increased (4.18 ± 1.40 vs baseline 1.97 ± 1.92; P = .02). The ejection fraction had increased 17% and LV end-systolic volume had decreased 40%. The global longitudinal strain increased from -5.3% to -9.1% (P < .05). Circumferential strain increased in both middle and apical LV segments, with the greatest improvement in the inferior lateral wall (from -11.4% to -20.6%, P < .001). These effects were maintained ≥6 weeks after device implantation without redilation. CONCLUSIONS: Less invasive than alternative therapies, epicardial ventricular reconstruction on the off-pump beating heart can restore LV twist and systolic strain and reverse LV remodeling in an ovine anteroapical aneurysm model.


Subject(s)
Cardiac Surgical Procedures , Heart Aneurysm/surgery , Heart Ventricles/surgery , Pericardium/surgery , Plastic Surgery Procedures , Ventricular Function, Left , Animals , Biomechanical Phenomena , Disease Models, Animal , Heart Aneurysm/diagnosis , Heart Aneurysm/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Pericardium/diagnostic imaging , Pericardium/physiopathology , Recovery of Function , Sheep , Stroke Volume , Systole , Time Factors , Torsion, Mechanical , Ultrasonography , Ventricular Remodeling
18.
Transl Res ; 162(6): 381-9, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23911638

ABSTRACT

Catheter-based renal artery denervation has demonstrated to be effective in decreasing blood pressure among patients with refractory hypertension. The anatomic distribution of renal artery nerves may influence the safety and efficacy profile of this procedure. We aimed to describe the anatomic distribution and density of periarterial renal nerves in the porcine model. Thirty arterial renal sections were included in the analysis by harvesting a tissue block containing the renal arteries and perirenal tissue from each animal. Each artery was divided into 3 segments (proximal, mid, and distal) and assessed for total number, size, and depth of the nerves according to the location. Nerve counts were greatest proximally (45.62% of the total nerves) and decreased gradually distally (mid, 24.58%; distal, 29.79%). The distribution in nerve size was similar across all 3 sections (∼40% of the nerves, 50-100 µm; ∼30%, 0-50 µm; ∼20%, 100-200 µm; and ∼10%, 200-500 µm). In the arterial segments ∼45% of the nerves were located within 2 mm from the arterial wall whereas ∼52% of all nerves were located within 2.5 mm from the arterial wall. Sympathetic efferent fibers outnumbered sensory afferent fibers overwhelmingly, intermixed within the nerve bundle. In the porcine model, renal artery nerves are seen more frequently in the proximal segment of the artery. Nerve size distribution appears to be homogeneous throughout the artery length. Nerve bundles progress closer to the arterial wall in the distal segments of the artery. This anatomic distribution may have implications for the future development of renal denervation therapies.


Subject(s)
Catheter Ablation/methods , Renal Artery/innervation , Sus scrofa/anatomy & histology , Sympathectomy/methods , Animals , Humans , Hypertension/therapy , Kidney/innervation , Models, Anatomic , Models, Animal , Models, Neurological , Sympathetic Nervous System/anatomy & histology , Translational Research, Biomedical
19.
EuroIntervention ; 9(4): 510-6, 2013 Aug 22.
Article in English | MEDLINE | ID: mdl-23965356

ABSTRACT

AIMS: The routine use of paclitaxel-coated balloons (PCB) in combination with bare metal stents (BMS) in de novo coronary lesions has been questioned. In this study, we aimed to compare the vascular response of BMS implanted using a second-generation PCB (BMS+PCB) with the TAXUS stent (PES) and a BMS control (BMS) in the familial hypercholesterolaemic swine (FHS) model of coronary injury. METHODS AND RESULTS: A total of 17 stents (PES=6, BMS+PCB=6, and BMS=5) were implanted in the coronary territory of 10 FHS using a 20% overstretch injury ratio. Imaging evaluation (QCA and IVUS) was conducted in all animals at baseline and 28 days following stent implantation. Following terminal imaging all animals were euthanised and stented coronary segments harvested for histological evaluation. At 28 days, the lowest degree of percentage diameter stenosis by QCA was achieved by the PES (2.9 ± 9%) followed by the BMS+PCB (9.5 ± 16.4%) and the BMS group (25.65 ± 18.7%, p<0.05). In histology, percentage area of stenosis (BMS+PCB=29.6 ± 6.4% vs. PES=21.5 ± 3.3% vs. BMS=55.2 ± 12.9%; p<0.01) and neointimal thickness (BMS+PCB=0.26 ± 0.1 mm vs. PES=0.21 ± 0.1 mm vs. BMS=0.59 ± 0.2 mm; p<0.01) were significantly reduced in both paclitaxel groups in comparison to BMS controls. Both BMS+PCB and BMS groups had higher endothelialisation scores (PES=1.50 ± 0.9 vs. BMS+PCB=2.73 ± 0.4 vs. BMS=3.00; p<0.05) and lower peri-strut inflammatory scores (PES=0.83 ± 0.4 vs. BMS+PCB=0.20 ± 0.2 vs. BMS=0.43 ± 0.6, p<0.05) when compared to PES. Neointima maturity (PCB+BMS: 2.00 [2-2.4] vs. PES: 1.00 [0.3-1] vs. BMS: 3.00, p<0.05) and fibrin deposition (PCB+BMS: 1.40 ± 0.3 vs. PES: 2.17 ± 0.7 vs. BMS: 0.27 ± 0.3, p<0.05) scores in PCB+BMS appeared to fall between the PES and the BMS ranges. CONCLUSIONS: In the FHS coronary injury model, BMS implantation using a PCB yields a degree of neointimal inhibition comparable to the PES. The BMS+PCB combination presented lower degrees of inflammation and fibrin deposition; however, signs of delayed healing were still present.


Subject(s)
Cardiovascular Agents/therapeutic use , Coronary Artery Disease/therapy , Drug-Eluting Stents , Iohexol/analogs & derivatives , Paclitaxel/therapeutic use , Polymers/therapeutic use , Angioplasty, Balloon, Coronary/methods , Animals , Constriction, Pathologic/pathology , Constriction, Pathologic/therapy , Coronary Artery Disease/pathology , Coronary Vessels/pathology , Disease Models, Animal , Neointima/therapy , Swine
20.
Interact Cardiovasc Thorac Surg ; 17(6): 915-22, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23985410

ABSTRACT

OBJECTIVES: Surgical ventricular reconstruction has been used to treat ischaemic cardiomyopathy with large akinetic or dyskinetic areas. However, application of this approach requires a sternotomy, cardiopulmonary bypass and a left ventriculotomy. This study assessed the feasibility and efficacy of minimally invasive, off-pump, epicardial catheter-based ventricular reconstruction (ECVR) in an anteroapical aneurysm ovine model. METHODS: Left ventricular (LV) anteroapical myocardial infarction was induced percutaneously by coil embolization of the left anterior descending coronary artery. Eight weeks after infarction, via mini left thoracotomy and without cardiopulmonary bypass, ECVR was performed in six sheep. The scar was excluded by placing anchor pairs on the LV epicardial anterior wall and the right ventricular side of the interventricular septum under fluoroscopic guidance. LV performance was evaluated before, immediately after device implantation and after 6 weeks by echocardiography. Terminal histopathology was performed. RESULTS: ECVR was completed expeditiously in all animals without complications. Parameters obtained 6 weeks after device implantation were compared with baseline (pre-device). End-systolic volume was decreased by 38% (25.6 ± 6.1 ml vs baseline 41.2 ± 7.2 ml, P = 0.02) with preservation of stroke volume. Ejection fraction was significantly increased by 13% (48.5 ± 7% vs baseline 35.8 ± 7%, P = 0.02). The circumferential strain in the anterior septum (-7.67 ± 5.12% vs baseline -0.96 ± 2.22%, P = 0.03) and anterior wall (-9.01 ± 3.51% vs baseline -4.15 ± 1.36%, P = 0.01) were significantly improved. The longitudinal strain in apex was reversed (-3.08 ± 1.53% vs baseline 3.09 ± 3.39%, P = 0.01). Histopathology showed full endocardial healing over the anchors with appreciable reduction of the chronic infarct in the LV. CONCLUSIONS: ECVR without cardiopulmonary bypass is a less invasive alternative to current standard therapies, reverses LV remodelling and improves cardiac performance in an ovine model of anteroapical aneurysm.


Subject(s)
Anterior Wall Myocardial Infarction/surgery , Cardiac Catheterization/instrumentation , Cardiac Catheters , Cardiac Surgical Procedures/instrumentation , Heart Aneurysm/surgery , Heart Failure/surgery , Heart Ventricles/surgery , Animals , Anterior Wall Myocardial Infarction/complications , Anterior Wall Myocardial Infarction/diagnosis , Anterior Wall Myocardial Infarction/physiopathology , Disease Models, Animal , Equipment Design , Feasibility Studies , Heart Aneurysm/complications , Heart Aneurysm/diagnosis , Heart Aneurysm/physiopathology , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/physiopathology , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Recovery of Function , Sheep , Thoracotomy , Time Factors , Ventricular Function, Left , Ventricular Remodeling
SELECTION OF CITATIONS
SEARCH DETAIL
...