Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 72
Filter
1.
Article in English | MEDLINE | ID: mdl-38657156

ABSTRACT

ABSTRACT: Neuroendocrine neoplasms are a heterogeneous group of gastrointestinal and lung tumors. Their diverse clinical manifestations, variable locations, and heterogeneity present notable diagnostic challenges. This article delves into the imaging modalities vital for their detection and characterization. Computed tomography is essential for initial assessment and staging. At the same time, magnetic resonance imaging (MRI) is particularly adept for liver, pancreatic, osseous, and rectal imaging, offering superior soft tissue contrast. The article also highlights the limitations of these imaging techniques, such as MRI's inability to effectively evaluate the cortical bone and the questioned cost-effectiveness of computed tomography and MRI for detecting specific gastric lesions. By emphasizing the strengths and weaknesses of these imaging techniques, the review offers insights into optimizing their utilization for improved diagnosis, staging, and therapeutic management of neuroendocrine neoplasms.

2.
Radiol Med ; 129(5): 677-686, 2024 May.
Article in English | MEDLINE | ID: mdl-38512626

ABSTRACT

PURPOSE: To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer. METHODS: This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations. RESULTS: Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs. CONCLUSIONS: The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.


Subject(s)
Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Sensitivity and Specificity , Tomography, X-Ray Computed , Humans , Pancreatic Neoplasms/diagnostic imaging , Male , Female , Retrospective Studies , Middle Aged , Aged , Tomography, X-Ray Computed/methods , Radiography, Dual-Energy Scanned Projection/methods , Predictive Value of Tests
3.
Br J Radiol ; 97(1155): 607-613, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38305574

ABSTRACT

OBJECTIVES: To evaluate the diagnostic performance of CT in the assessment of extra-pancreatic perineural invasion (EPNI) in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective study included 123 patients (66 men; median age, 66 years) with PDAC who underwent radical surgery and pancreatic protocol CT for assessing surgical resectability between September 2011 and March 2019. Among the 123 patients, 97 patients had received neoadjuvant chemoradiation therapy (CRT). Two radiologists reviewed the CT images for evidence of EPNI using a 5-point scale (5 = definitely present, 4 = probably present, 3 = equivocally present, 2 = probably absent, and 1 = definitely absent). Diagnostic performance for assessing EPNI was evaluated with receiver operating characteristic (ROC) curve analysis. RESULTS: The sensitivity, specificity, and area under the ROC curve for assessing EPNI were 98%, 30%, and 0.62 in all patients; 97%, 22%, and 0.59 in patients with neoadjuvant CRT; and 100%, 100%, and 1.00 in patients without neoadjuvant CRT, respectively. False-positive assessment of EPNI occurred in 23% of patients (n = 28/123), and 100% of these (n = 28/28) had received neoadjuvant CRT. There was moderate to substantial agreement between the readers (ĸ = 0.49-0.62). CONCLUSION: Pancreatic protocol CT has better diagnostic performance for determination of EPNI in treatment naïve patients with PDAC and overestimation of EPNI is likely in patients who have received preoperative CRT. ADVANCES IN KNOWLEDGE: Pancreatic protocol CT has better diagnostic performance for the detection of EPNI in treatment naïve patients compared to patients receiving neoadjuvant CRT.


Subject(s)
Adenocarcinoma , Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Male , Humans , Aged , Neoadjuvant Therapy/methods , Retrospective Studies , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/therapy , Pancreatic Neoplasms/pathology , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/therapy , Tomography, X-Ray Computed/methods , Adenocarcinoma/pathology
4.
J Am Coll Radiol ; 20(11S): S471-S480, 2023 11.
Article in English | MEDLINE | ID: mdl-38040465

ABSTRACT

The differential diagnosis for left lower quadrant pain is wide and conditions range from the benign and self-limited to life-threatening surgical emergencies. Along with patient history, physical examination, and laboratory tests, imaging is often critical to limit the differential diagnosis and identify life-threatening abnormalities. This document will discuss the guidelines for the appropriate use of imaging in the initial workup for patients who present with left lower quadrant pain, patients with suspected diverticulitis, and patients with suspected complications from diverticulitis. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Diverticulitis , Societies, Medical , Humans , Abdominal Pain , Diagnostic Imaging , Evidence-Based Medicine , United States
5.
Radiol Clin North Am ; 61(5): 761-769, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37495285

ABSTRACT

Deceased liver donor transplantation is increasing in prevalence resulting in larger volumes of posttransplant imaging studies. Radiologists should familiarize themselves with the spectrum of normal posttransplant anatomy. The key findings can be categorized into 4 systems reconstructed during surgery: hepatic venous, portal venous, hepatic arterial, and biliary ductal systems. Here we discuss the imaging findings seen with the most common surgical techniques, those that can be misidentified as complications, and some less common variations resulting from different surgical techniques.


Subject(s)
Biliary Tract , Liver Transplantation , Humans , Liver Transplantation/methods , Liver/diagnostic imaging , Liver/surgery , Living Donors , Hepatic Artery/diagnostic imaging , Hepatic Artery/surgery , Hepatic Artery/anatomy & histology
6.
Abdom Radiol (NY) ; 48(10): 3253-3264, 2023 10.
Article in English | MEDLINE | ID: mdl-37369922

ABSTRACT

BACKGROUND: CT image reconstruction has evolved from filtered back projection to hybrid- and model-based iterative reconstruction. Deep learning-based image reconstruction is a relatively new technique that uses deep convolutional neural networks to improve image quality. OBJECTIVE: To evaluate and compare 1.25 mm thin-section abdominal CT images reconstructed with deep learning image reconstruction (DLIR) with 5 mm thick images reconstructed with adaptive statistical iterative reconstruction (ASIR-V). METHODS: This retrospective study included 52 patients (31 F; 56.9±16.9 years) who underwent abdominal CT scans between August-October 2019. Image reconstruction was performed to generate 5 mm images at 40% ASIR-V and 1.25 mm DLIR images at three strengths (low [DLIR-L], medium [DLIR-M], and high [DLIR-H]). Qualitative assessment was performed to determine image noise, contrast, visibility of small structures, sharpness, and artifact based on a 5-point-scale. Image preference determination was based on a 3-point-scale. Quantitative assessment included measurement of attenuation, image noise, and contrast-to-noise ratios (CNR). RESULTS: Thin-section images reconstructed with DLIR-M and DLIR-H yielded better image quality scores than 5 mm ASIR-V reconstructed images. Mean qualitative scores of DLIR-H for noise (1.77 ± 0.71), contrast (1.6 ± 0.68), small structure visibility (1.42 ± 0.66), sharpness (1.34 ± 0.55), and image preference (1.11 ± 0.34) were the best (p<0.05). DLIR-M yielded intermediate scores. All DLIR reconstructions showed superior ratings for artifacts compared to ASIR-V (p<0.05), whereas each DLIR group performed comparably (p>0.05, 0.405-0.763). In the quantitative assessment, there were no significant differences in attenuation values between all reconstructions (p>0.05). However, DLIR-H demonstrated the lowest noise (9.17 ± 3.11) and the highest CNR (CNRliver = 26.88 ± 6.54 and CNRportal vein = 7.92 ± 3.85) (all p<0.001). CONCLUSION: DLIR allows generation of thin-section (1.25 mm) abdominal CT images, which provide improved image quality with higher inter-reader agreement compared to 5 mm thick images reconstructed with ASIR-V. CLINICAL IMPACT: Improved image quality of thin-section CT images reconstructed with DLIR has several benefits in clinical practice, such as improved diagnostic performance without radiation dose penalties.


Subject(s)
Deep Learning , Humans , Retrospective Studies , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Image Processing, Computer-Assisted/methods , Algorithms
7.
Eur Radiol ; 33(5): 3617-3626, 2023 May.
Article in English | MEDLINE | ID: mdl-36897348

ABSTRACT

OBJECTIVES: To investigate the diagnostic performance and interobserver variability in the determination of arterial invasion in pancreatic ductal adenocarcinoma (PDAC) and determine the best CT imaging criterion. METHODS: We retrospectively evaluated 128 patients with PDAC (73 men and 55 women) who underwent preoperative contrast-enhanced CT. Five board-certified radiologists (expert) and four fellows (non-expert]) independently assessed the arterial invasion (celiac, superior mesenteric, splenic, and common hepatic arteries) using a 6-point score: 1, no tumor contact; 2, hazy attenuation ≤ 180°; 3, hazy attenuation > 180°; 4, solid soft tissue contact ≤ 180°; 5, solid soft tissue contact > 180°; and 6, contour irregularity. ROC analysis was performed to evaluate the diagnostic performance and determine the best diagnostic criterion for arterial invasion, with pathological or surgical findings as references. Interobserver variability was assessed using Fleiss's ĸ statistics. RESULTS: Among the 128 patients, 35.2% (n = 45/128) received neoadjuvant treatment (NTx). Solid soft tissue contact ≤ 180° was the best diagnostic criterion for arterial invasion as defined by the Youden Index both in patients who did and did not receive NTx (sensitivity, 100% vs. 100%; specificity, 90% vs. 93%; and AUC, 0.96 vs. 0.98, respectively). Interobserver variability among the non-expert was not inferior to that among the expert (ĸ = 0.61 vs 0.61; p = .39 and ĸ = 0.59 vs 0.51; p < .001 in patients treated with and without NTx, respectively). CONCLUSIONS: Solid soft tissue contact ≤ 180° was the best diagnostic criterion for the determination of arterial invasion in PDAC. Considerable interobserver variability was seen among the radiologists. KEY POINTS: • Solid soft tissue contact ≤ 180° was the best diagnostic criterion for the determination of arterial invasion in pancreatic ductal adenocarcinoma. • Interobserver agreement among non-expert radiologists was almost comparable to that among expert radiologists.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Male , Humans , Female , Retrospective Studies , Pancreatic Neoplasms/pathology , Carcinoma, Pancreatic Ductal/pathology , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms
8.
Abdom Radiol (NY) ; 48(4): 1514-1525, 2023 04.
Article in English | MEDLINE | ID: mdl-36799998

ABSTRACT

Computed tomography (CT) has witnessed tremendous growth in utilization. Despite its immense benefits, there is a growing concern from the general public and the medical community about the detrimental consequences of ionizing radiation from CT. Anxiety from the perceived risks associated with CT can deter referring physicians from ordering clinically indicated CT scans and patients from undergoing medically necessary exams. This article discusses various strategies for educating patients and healthcare providers on the benefits and risks of CT scanning and salient techniques for effective communication.


Subject(s)
Health Personnel , Tomography, X-Ray Computed , Humans , Radiation Dosage , Tomography, X-Ray Computed/adverse effects
9.
J Am Coll Radiol ; 19(11S): S329-S340, 2022 11.
Article in English | MEDLINE | ID: mdl-36436960

ABSTRACT

Abdominopelvic hernias are common clinical entities composed of a wide variety of congenital, traumatic, and iatrogenic etiologies. Any weakness in the body wall may result in hernia of cavity contents with concomitant risks of morbidity and mortality. Presentations may be specific, palpable body wall mass/bulge, or vague, nonspecific pain through bowel obstruction. This document focuses on initial imaging of the adult population with signs of symptoms prompting suspicion of abdominopelvic hernia. Imaging of the abdomen and pelvis to evaluate defects is essential for prompt diagnosis and treatment. Often CT and ultrasound are the first-line modalities to quickly evaluate the abdomen and pelvis, providing for accurate diagnoses and management of patients. MRI protocols may be useful as first-line imaging studies, especially in patients with orthopedic instrumentation. Although often performed, abdominal radiographs and fluorographic procedures may provide indirect evidence of hernias but are usually not indicated for initial diagnosis of hernia. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer-reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer-reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Contrast Media , Societies, Medical , Humans , Evidence-Based Medicine , Magnetic Resonance Imaging/methods , Hernia
10.
J Am Coll Radiol ; 19(11S): S445-S461, 2022 11.
Article in English | MEDLINE | ID: mdl-36436969

ABSTRACT

This document focuses on imaging in the adult and pregnant populations with right lower quadrant (RLQ) abdominal pain, including patients with fever and leukocytosis. Appendicitis remains the most common surgical pathology responsible for RLQ abdominal pain in the United States. Other causes of RLQ pain include right colonic diverticulitis, ureteral stone, and infectious enterocolitis. Appropriate imaging in the diagnosis of appendicitis has resulted in decreased negative appendectomy rate from as high as 25% to approximately 1% to 3%. Contrast-enhanced CT remains the primary and most appropriate imaging modality to evaluate this patient population. MRI is approaching CT in sensitivity and specificity as this technology becomes more widely available and utilization increases. Unenhanced MRI and ultrasound remain the diagnostic procedures of choice in the pregnant patient. MRI and ultrasound continue to perform best in the hands of the experts. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer-reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer-reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Appendicitis , Pregnancy , Female , Humans , United States , Societies, Medical , Evidence-Based Medicine , Diagnosis, Differential , Abdominal Pain/diagnostic imaging , Magnetic Resonance Imaging/methods
11.
Abdom Radiol (NY) ; 47(8): 2835-2844, 2022 08.
Article in English | MEDLINE | ID: mdl-35760922

ABSTRACT

PURPOSE: To compare the diagnostic performance for detecting vascular involvement and determining resectability differences regarding pancreatic ductal adenocarcinoma (PDAC) between contrast-enhanced CT and MRI. METHODS: This retrospective study evaluated 82 patients (73 years, 46 men) with PDAC who underwent both preoperative contrast-enhanced CT and MRI from January 2008 to March 2021. Two radiologists independently categorized vascular involvements for celiac, superior mesenteric, splenic, and common hepatic arteries, and portal, superior mesenteric, and splenic veins into no tumor contact, solid soft-tissue contact ≤ 180°, or solid soft-tissue contact > 180°. The radiologists also classified resectability into resectable, borderline resectable, or locally advanced. Receiver-operating-characteristic (ROC) analysis was conducted to evaluate the diagnostic performances for detecting vascular involvements which were confirmed by pathological or intraoperative findings. The proportion of resectability classifications was compared between CT and MRI by the Fisher's exact test. RESULTS: No statistical difference was found in the diagnostic performances for detecting vascular involvement in CT (area under the ROC curve [AUC], 0.50-0.89) and MRI (AUC, 0.51-0.75) (P = 0.06-> 0.99). Resectability on CT were 79% and 68%, 20% and 26%, and 1% and 6% for resectable, borderline resectable, and locally advanced tumors for reviewers 1 and 2; those on MRI were 87% and 81%, 12% and 13%, and 1% and 6%, respectively. The proportion of resectability classifications was not different between CT and MRI (P = 0.48 and = 0.15 for reviewers 1 and 2, respectively). CONCLUSION: The diagnostic performance for detecting vascular involvement and determining resectability of PDAC on contrast-enhanced MRI were comparable with pancreatic protocol CT.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Aged , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/surgery , Female , Humans , Magnetic Resonance Imaging/methods , Male , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/surgery , Retrospective Studies , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms
12.
J Am Coll Radiol ; 19(5S): S208-S222, 2022 05.
Article in English | MEDLINE | ID: mdl-35550803

ABSTRACT

Preoperative imaging of rectal carcinoma involves accurate assessment of the primary tumor as well as distant metastatic disease. Preoperative imaging of nonrectal colon cancer is most beneficial in identifying distant metastases, regardless of primary T or N stage. Surgical treatment remains the definitive treatment for colon cancer, while organ-sparing approach may be considered in some rectal cancer patients based on imaging obtained before and after neoadjuvant treatment. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Subject(s)
Colonic Neoplasms , Rectal Neoplasms , Diagnostic Imaging/methods , Humans , Neoadjuvant Therapy , Societies, Medical , United States
13.
BMC Med Imaging ; 22(1): 23, 2022 02 08.
Article in English | MEDLINE | ID: mdl-35135492

ABSTRACT

BACKGROUND: To evaluate the utility of histogram analysis (HA) of apparent diffusion coefficient (ADC) values to predict the overall survival (OS) in patients with pancreatic ductal adenocarcinoma (PDAC) and to correlate with pathologically evaluated massive intratumoral necrosis (MITN). MATERIALS AND METHODS: Thirty-nine patients were included in this retrospective study with surgically resected PDAC who underwent preoperative magnetic resonance imaging. Twelve patients received neoadjuvant chemotherapy. HA on the ADC maps were performed to obtain the tumor HA parameters. Using Cox proportional regression analysis adjusted for age, time-dependent receiver-operating-characteristic (ROC) curve analysis, and Kaplan-Meier estimation, we evaluated the association between HA parameters and OS. The association between prognostic factors and pathologically confirmed MITN was assessed by logistic regression analysis. RESULTS: The median OS was 19.9 months. The kurtosis (P < 0.001), entropy (P = 0.013), and energy (P = 0.04) were significantly associated with OS. The kurtosis had the highest area under the ROC curve (AUC) for predicting 3-year survival (AUC 0.824) among these three parameters. Between the kurtosis and MITN, the logistic regression model revealed a positive correlation (P = 0.045). Lower survival rates occurred in patients with high kurtosis (cutoff value > 2.45) than those with low kurtosis (≤ 2.45) (P < 0.001: 1-year survival rate, 75.2% versus 100%: 3-year survival rate, 14.7% versus 100%). CONCLUSIONS: HA derived kurtosis obtained from tumor ADC maps might be a potential imaging biomarker for predicting the presence of MITN and OS in patients with PDAC.


Subject(s)
Carcinoma, Pancreatic Ductal/mortality , Carcinoma, Pancreatic Ductal/pathology , Pancreatic Neoplasms/mortality , Pancreatic Neoplasms/pathology , Aged , Aged, 80 and over , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/therapy , Diffusion Magnetic Resonance Imaging , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Necrosis , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/therapy , Proportional Hazards Models , Regression Analysis , Retrospective Studies , Survival Rate , Pancreatic Neoplasms
14.
Eur Radiol ; 32(4): 2470-2480, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34665317

ABSTRACT

OBJECTIVES: To derive a CT-based scoring system incorporating arterial involvement and resectability status to predict R0 resection in patients with pancreatic ductal adenocarcinoma (PDAC) undergoing neoadjuvant chemoradiation therapy (CRT). METHODS: This retrospective study included 112 patients with PDAC who underwent dynamic contrast-enhanced CT before and after neoadjuvant CRT. A 5-point score was used to determine arterial involvement (A score; 1 = no involvement, 2 = haziness, 3 = abutment, 4 = encasement, 5 = deformity) and 4-point score evaluating resectability status (R score; 1 = resectable, 2 = borderline resectable [BR] with venous involvement, 3 = BR with arterial involvement, 4 = locally advanced [LA]). A score before and after CRT were summed with R score before and after CRT to compute the AR score (ARtotal). The associations between ARtotal, R0 resection, overall survival (OS), and disease-free survival (DFS) were assessed. RESULTS: The ARtotal was associated with R0 resection (p < .001) and showed area under the ROC curve of 0.79 for differentiating R0 and R1 resections. Median OS was significantly lower for patients with ARtotal  > 9 (median: 35.2 months) compared to patients with ARtotal ≤ 9 (median: not estimable) (p < .001). Similar results were observed for DFS (median, 16.8 months in > 9 vs median, not estimable in ≤ 9; p < .001). CONCLUSIONS: A composite score which incorporates degree of arterial involvement and resectability status before and after neoadjuvant CRT is associated with R0 resection and discriminates between R0 and R1 resections in PDAC. KEY POINTS: • A scoring system incorporating arterial involvement and resectability status was associated with R0 resection. • ARtotal > 9 could predict patients' overall and disease-free survival.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Antineoplastic Combined Chemotherapy Protocols , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/pathology , Carcinoma, Pancreatic Ductal/therapy , Humans , Neoadjuvant Therapy , Pancreatic Neoplasms/drug therapy , Pancreatic Neoplasms/therapy , Retrospective Studies
15.
AJR Am J Roentgenol ; 218(4): 746-755, 2022 04.
Article in English | MEDLINE | ID: mdl-34668387

ABSTRACT

BACKGROUND. Clinical use of the dual-energy CT (DECT) iodine quantification technique is hindered by between-platform (i.e., across different manufacturers) variability in iodine concentration (IC) values, particularly at low iodine levels. OBJECTIVE. The purpose of this study was to develop in an anthropomorphic phantom a method for reducing between-platform variability in quantification of low iodine content levels using DECT and to evaluate the method's performance in patients undergoing serial clinical DECT examinations on different platforms. METHODS. An anthropomorphic phantom in three body sizes, incorporating varied lesion types and scanning conditions, was imaged with three distinct DECT implementations from different manufacturers at varying radiation exposures. A cross-platform iodine quantification model for correcting between-platform variability at low iodine content was developed using the phantom data. The model was tested in a retrospective series of 30 patients (20 men, 10 women; median age, 62 years) who each underwent three serial contrast-enhanced DECT examinations of the abdomen and pelvis (90 scans total) for routine oncology surveillance using the same three DECT platforms as in the phantom. Estimated accuracy of phantom IC values was summarized using root-mean-square error (RMSE) relative to known IC. Between-platform variability in patients was summarized using root-mean-square deviation (RMSD). RMSE and RMSD were compared between platform-based IC (ICPB) and cross-platform IC (ICCP). ICPB was normalized to aorta and portal vein. RESULTS. In the phantom study, mean RMSE of ICPB across platforms and other experimental conditions was 0.65 ± 0.18 mg I/mL compared with 0.40 ± 0.08 mg I/mL for ICCP (38% decrease in mean RMSE; p < .05). Intrapatient between-platform variability across serial DECT examinations was higher for ICPB than ICCP (RMSD, 97% vs 88%; p < .001). Between-platform variability was not reduced by normalization of ICPB to aorta (RMSD, 97% vs 101%; p = .12) or portal vein (RMSD, 97% vs 97%; p = .81). CONCLUSION. The developed cross-platform method significantly decreased between-platform variability occurring at low iodine content with platform-based DECT iodine quantification. CLINICAL IMPACT. With further validation, the cross-platform method, which has been implemented as a web-based app, may expand clinical use of DECT iodine quantification, yielding meaningful IC values that reflect tissue biologic viability or treatment response in patients who undergo serial examinations on different platforms.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Abdomen , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
16.
J Am Coll Radiol ; 18(11S): S268-S282, 2021 11.
Article in English | MEDLINE | ID: mdl-34794588

ABSTRACT

This review summarizes the relevant literature for the selection of the initial imaging in 4 clinical scenarios in patients with suspected inflammatory disease or postoperative complication of the anorectum. These clinical scenarios include suspected perianal fistula or abscess; rectovesicular or rectovaginal fistula; proctitis or pouchitis; and suspected complication following proctectomy, coloproctectomy, or colectomy with a pouch or other anastomosis. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios of anorectal disease. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Subject(s)
Rectal Diseases , Societies, Medical , Diagnostic Imaging , Humans , United States
17.
Magn Reson Imaging Clin N Am ; 29(3): 305-320, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34243919

ABSTRACT

Computed tomography (CT) is often performed as the initial imaging study for the workup of patients with known or suspected liver disease. Our article reviews liver CT techniques and protocols in clinical practice along with updates on relevant CT advances, including wide-detector CT, radiation dose optimization, and multienergy scanning, that have already shown clinical impact. Particular emphasis is placed on optimizing the late arterial phase of enhancement, which is critical to evaluation of hepatocellular carcinoma. We also discuss emerging techniques that may soon influence clinical care.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media , Humans , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Tomography, X-Ray Computed
18.
Radiology ; 300(3): 615-623, 2021 09.
Article in English | MEDLINE | ID: mdl-34128721

ABSTRACT

Background The bolus-tracking technique from single-energy CT has been applied to dual-energy CT (DECT) without optimization or validation. Further optimization is imperative because of a paucity of literature and differences in the attenuation profile of virtual monoenergetic images (VMIs). Purpose To determine the optimal trigger threshold with bolus-tracking technique for DECT angiography (DECTA) in a phantom study and assess the feasibility of an optimized threshold for bolus-tracking technique in DECTA at 40 keV with a 50% reduced iodine dose in human participants. Materials and Methods A phantom study with rapid kilovoltage-switching DECT was performed to determine the optimal threshold for each kiloelectron-volt VMI. In a prospective study, consecutive participants who underwent whole-body CT angiography (CTA) from August 2018 to July 2019 were randomized into three groups: single-energy CTA (SECTA) with standard iodine dose (600 mg of iodine per kilogram), DECTA with 50% reduced iodine dose (300 mg of iodine per kilogram) by using a conventional threshold, and DECTA with 300 mg of iodine per kilogram by using an optimized threshold. A trigger threshold of 100 HU at 120 kVp was used as a reference for comparison. Injected iodine doses and aortic CT numbers were compared among the three groups using Kruskal-Wallis test. Results Ninety-six participants (mean age ± standard deviation, 72 years ± 9; 80 men) were evaluated (32 participants in each group). The optimized threshold for VMIs at 40 keV was 30 HU. The median iodine dose was lower in the optimized DECTA group (13 g) compared with conventional DECTA (19 g) and SECTA (26 g) groups (P < .017 for each comparison). The median aortic CT numbers were higher in the order corresponding to conventional DECTA (655-769 HU), optimized DECTA (543-610 HU), and SECTA (343-359 HU) groups (P < .001). Conclusion The optimized trigger threshold of 30 HU for bolus-tracking technique during dual-energy CT angiography at 40 keV achieved lower iodine load while maintaining aortic enhancement. ©RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Malayeri in this issue.


Subject(s)
Computed Tomography Angiography/methods , Contrast Media/administration & dosage , Iopamidol/administration & dosage , Radiography, Dual-Energy Scanned Projection/methods , Aged , Female , Humans , Male , Phantoms, Imaging , Prospective Studies
20.
Eur Radiol ; 31(11): 8342-8353, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33893535

ABSTRACT

OBJECTIVES: To investigate the image quality and perception of a sinogram-based deep learning image reconstruction (DLIR) algorithm for single-energy abdominal CT compared to standard-of-care strength of ASIR-V. METHODS: In this retrospective study, 50 patients (62% F; 56.74 ± 17.05 years) underwent portal venous phase. Four reconstructions (ASIR-V at 40%, and DLIR at three strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H)) were generated. Qualitative and quantitative image quality analysis was performed on the 200 image datasets. Qualitative scores were obtained for image noise, contrast, small structure visibility, sharpness, and artifact by three blinded radiologists on a 5-point scale (1, excellent; 5, very poor). Radiologists also indicated image preference on a 3-point scale (1, most preferred; 3, least preferred). Quantitative assessment was performed by measuring image noise and contrast-to-noise ratio (CNR). RESULTS: DLIR had better image quality scores compared to ASIR-V. Scores on DLIR-H for noise (1.40 ± 0.53), contrast (1.41 ± 0.55), small structure visibility (1.51 ± 0.61), and sharpness (1.60 ± 0.54) were the best (p < 0.05) followed by DLIR-M (1.85 ± 0.52, 1.66 ± 0.57, 1.69 ± 0.59, 1.68 ± 0.46), DLIR-L (2.29 ± 0.58, 1.96 ± 0.61, 1.90 ± 0.65, 1.86 ± 0.46), and ASIR-V (2.86 ± 0.67, 2.55 ± 0.58, 2.34 ± 0.66, 2.01 ± 0.36). Ratings for artifacts were similar for all reconstructions (p > 0.05). DLIRs did not influence subjective textural perceptions and were preferred over ASIR-V from the beginning. All DLIRs had a higher CNR (26.38-102.30%) and lower noise (20.64-48.77%) than ASIR-V. DLIR-H had the best objective scores. CONCLUSION: Sinogram-based deep learning image reconstructions were preferred over iterative reconstruction subjectively and objectively due to improved image quality and lower noise, even in large patients. Use in clinical routine may allow for radiation dose reduction. KEY POINTS: • Deep learning image reconstructions (DLIRs) have a higher contrast-to-noise ratio compared to medium-strength hybrid iterative reconstruction techniques. • DLIR may be advantageous in patients with large body habitus due to a lower image noise. • DLIR can enable further optimization of radiation doses used in abdominal CT.


Subject(s)
Deep Learning , Algorithms , Humans , Image Processing, Computer-Assisted , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...