Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
AJR Am J Roentgenol ; 220(2): 283-295, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36129222

ABSTRACT

BACKGROUND. Iterative reconstruction (IR) techniques are susceptible to contrast-dependent spatial resolution, limiting overall radiation dose reduction potential. Deep learning image reconstruction (DLIR) may mitigate this limitation. OBJECTIVE. The purpose of our study was to evaluate low-contrast detectability performance and radiation-saving potential of a DLIR algorithm in comparison with filtered back projection (FBP) and IR using a human multireader noninferiority study design and task-based observer modeling. METHODS. A dual-phantom construct, consisting of a low-contrast detectability module (21 low-contrast hypoattenuating objects in seven sizes [2.4-10.0 mm] and three contrast levels [-15, -10, -5 HU] embedded within liver-equivalent background) and a phantom, was imaged at five radiation exposures (CTDIvol range, 1.4-14.0 mGy; size-specific dose estimate, 2.5-25.0 mGy; 90%-, 70%-, 50%-, and 30%-reduced radiation levels and full radiation level) using an MDCT scanner. Images were reconstructed using FBP, hybrid IR (ASiR-V), and DLIR (TrueFidelity). Twenty-four readers of varying experience levels evaluated images using a two-alternative forced choice. A task-based observer model (detectability index [d']) was calculated. Reader performance was estimated by calculating the AUC using a noninferiority method. RESULTS. Compared with FBP and IR methods at routine radiation levels, DLIR medium and DLIR high settings showed noninferior performance through a 90% radiation reduction (except DLIR medium setting at 70% reduced level). The IR method was non-inferior to routine radiation FBP only for 30% and 50% radiation reductions. No significant difference in d' was observed between routine radiation FBP and DLIR high setting through a 70% radiation reduction. Reader experience was not correlated with diagnostic accuracy (R2 = 0.005). CONCLUSION. Compared with FBP or IR methods at routine radiation levels, certain DLIR algorithm weightings yielded noninferior low-contrast detectability with radiation reductions of up to 90% as measured by 24 human readers and up to 70% as assessed by a task-based observer model. CLINICAL IMPACT. DLIR has substantial potential to preserve contrast-dependent spatial resolution for the detection of hypoattenuating lesions at decreased radiation levels in a phantom model, addressing a major shortcoming of current IR techniques.


Subject(s)
Deep Learning , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Phantoms, Imaging , Image Processing, Computer-Assisted
2.
Radiol Technol ; 93(6): 566-572, 2022.
Article in English | MEDLINE | ID: mdl-35790311

Subject(s)
Radiology , Radiography
3.
Radiology ; 302(1): 164-174, 2022 01.
Article in English | MEDLINE | ID: mdl-34698569

ABSTRACT

Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed. For head and neck examinations, dose indexes were analyzed based on patient age; for body examinations, dose indexes were analyzed for patient age and effective diameter. Data from 1 543 535 examinations provided medians for AD and 75th percentiles for DRLs for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE). Results Of all facilities analyzed, 66% of the facilities (1068 of 1625) were community hospitals, 16% (264 of 1625) were freestanding centers, 9.5% (154 of 1625) were academic facilities, and 3.5% (57 of 1625) were dedicated children's hospitals. Fifty-two percent of the patients (798 577 of 1 543 535) were boys, and 48% (744 958 of 1 543 535) were girls. The median age of patients was 14 years (boys, 13 years; girls, 15 years). The head was the most frequent anatomy examined with CT (876 655 of 1 543 535 examinations [57%]). For head without contrast material CT examinations, the age-based CTDIvol AD ranged from 19 to 46 mGy, and DRL ranged from 23 to 55 mGy, with both AD and DRL increasing with age. For body examinations, DRLs and ADs for size-based CTDIvol, SSDE, and DLP increased consistently with the patient's effective diameter. Conclusion Diagnostic reference levels and achievable doses as a function of patient age and effective diameter were developed for the 10 most commonly performed CT pediatric examinations using American College of Radiology Dose Index Registry data. These benchmarks can guide CT facilities in adjusting pediatric CT protocols and resultant doses for their patients. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on October 29, 2021.


Subject(s)
Diagnostic Reference Levels , Radiation Dosage , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/statistics & numerical data , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Practice Guidelines as Topic , Registries , United States
4.
Urology ; 160: 60-68, 2022 02.
Article in English | MEDLINE | ID: mdl-34757049

ABSTRACT

OBJECTIVE: To convene a multi-disciplinary panel to develop a pathway for Emergency Department (ED) patients with suspected nephrolithiasis and then prospectively evaluate its effect on patient care. MATERIALS AND METHODS: The STONE Pathway was developed and linked to order sets within our Electronic Health Record in April 2019. Records were prospectively reviewed for ED patients who underwent ultrasound or Computerized Tomography (CT) to evaluate suspected nephrolithiasis between January 2019 and August 2019 within our institution. The primary outcome measure was the proportion of patients whose ED CT was low dose (<4 mSv). Secondary outcome measures included receipt of pathway-concordant pain medications and urine strainers. Order set utilization was evaluated as a process measure. Balance measures assessed included repeat ED visits, imaging, hospitalizations, and a urologic clinic visit or surgery within 30 days of discharge. RESULTS: 441 patients underwent ED imaging, of whom 261 (59%) were evaluated for suspected nephrolithiasis. The STONE Pathway was used in 50 (30%) eligible patients. Patients treated with the Pathway were more likely to undergo low-dose CTs (49% vs 23%, P <.001), and receive guideline-concordant pain medications such as NSAIDs (90% vs 62%, P <.001), and were less likely to return to the ED within 30 days (13% vs 2%, P = .01). These measures demonstrated special cause variation following Pathway release. CONCLUSION: Clinical pathways increase compliance with evidence-based practices for pain control and imaging in nephrolithiasis emergency care and may improve the delivery of value-based care.


Subject(s)
Critical Pathways , Kidney Calculi , Emergencies , Emergency Service, Hospital , Female , Hospitalization , Humans , Male , Pain
6.
Med Phys ; 48(8): 4523-4531, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34231224

ABSTRACT

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high-resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR-guided radiation therapy (MRgRT) - achieved through the integration of MR imaging systems and linear accelerators - has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community-based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee's membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee's parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.


Subject(s)
Magnetic Resonance Imaging , Radiotherapy, Image-Guided , Humans , Particle Accelerators , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , United States
7.
AJR Am J Roentgenol ; 217(4): 883-887, 2021 10.
Article in English | MEDLINE | ID: mdl-33236649

ABSTRACT

OBJECTIVE. To reduce staff exposure to infection and maintain operational efficiency, we have developed a protocol to image patients using portable chest radiography through the glass of an isolation room. This technique is safe and easy to implement. Images are of comparable quality to standard portable radiographs. CONCLUSION. This protocol, used routinely by our department during the COVID-19 pandemic, can be applied to any situation in which the patient is placed in isolation.


Subject(s)
COVID-19/diagnostic imaging , Patient Isolation/methods , Point-of-Care Systems , Radiography, Thoracic/methods , COVID-19/prevention & control , Humans , Lung/diagnostic imaging , Pandemics , SARS-CoV-2
8.
CVIR Endovasc ; 3(1): 69, 2020 Sep 22.
Article in English | MEDLINE | ID: mdl-32960372

ABSTRACT

PURPOSE: To quantify and categorize fluoroscopically-guided procedures with radiation doses exceeding 5000 mGy reference point air kerma (Ka,r). Ka,r > 5000 mGy has been defined as a "significant radiation dose" by the Society of Interventional Radiology. Identification and analysis of interventions with high radiation doses has the potential to reduce radiation-induced injuries. MATERIALS AND METHODS: Radiation dose data from a dose monitoring system for 19 interventional suites and 89,549 consecutive patient encounters from January 1, 2013 to August 1, 2019 at a single academic institution were reviewed. All patient encounters with Ka,r > 5000 mGy were included. All other encounters were excluded (n = 89,289). Patient demographics, medical specialty, intervention type, fluoroscopy time (minutes), dose area product (mGy·cm2), and Ka,r (mGy) were evaluated. RESULTS: There were 260 (0.3%) fluoroscopically-guided procedures with Ka,r > 5000 mGy. Of the 260 procedures which exceeded 5000 mGy, neurosurgery performed 81 (30.5%) procedures, followed by interventional radiology (n = 75; 28.2%), neurointerventional radiology (n = 55; 20.7%), and vascular surgery (n = 49; 18.4%). The procedures associated with the highest Ka,r were venous stent reconstruction performed by interventional radiology, arteriovenous malformation embolization performed by neurointerventional radiology, spinal hardware fixation by neurosurgery, and arterial interventions performed by vascular surgery. Neurointerventional radiology had the highest mean Ka,r (7,799 mGy), followed by neurosurgery (7452 mGy), vascular surgery (6849 mGy), and interventional radiology (6109 mGy). The mean Ka,r for interventional radiology performed procedures exceeding 5000 mGy was significantly lower than that for neurointerventional radiology, neurosurgery, and vascular surgery. CONCLUSIONS: Fluoroscopically-guided procedures with radiation dose exceeding 5000 mGy reference point air kerma are uncommon. The results of this study demonstrate that a large proportion of cases exceeding 5000 mGy were performed by non-radiologists, who likely do not receive the same training in radiation physics, radiation biology, and dose reduction techniques as radiologists.

10.
Acad Radiol ; 26(2): 163-169, 2019 02.
Article in English | MEDLINE | ID: mdl-29934019

ABSTRACT

RATIONALE AND OBJECTIVES: To assess the implementation of radiation dose monitoring software, create a process for clinical follow-up and documentation of high-dose cases, and quantify the number of patient reported radiation-induced tissue reactions in fluoroscopically guided interventional radiology (IR) and neuro-interventional radiology (NIR) procedures. MATERIALS AND METHODS: Web-based radiation dose monitoring software was installed at our institution and a process to flag all procedures with reference point air kerma (Ka,r) > 5000 mGy was implemented. The entrance skin dose was estimated and formal reports generated, allowing for physician-initiated clinical follow-up. To evaluate our process, we reviewed all IR and NIR procedures performed at our hospital over a 1-year period. For all procedures with Ka,r > 5000 mGy, retrospective medical chart review was performed to evaluate for patient reported tissue reactions. RESULTS: Three thousand five hundred eighty-two procedures were performed over the 1-year period. The software successfully transferred dose data on 3363 (93.9%) procedures. One thousand three hundred ninety-three (368 IR and 1025 NIR) procedures were further analyzed after excluding 2189 IR procedures with Ka,r < 2000 mGy. Ten of 368 (2.7%) IR and 52 of 1025 (5.1%) NIR procedures exceeded estimated skin doses of 5000 mGy. All 10 IR cases were abdominal/pelvic trauma angiograms with/without embolization; there were no reported tissue reactions. Of 52 NIR cases, 49 were interventions and 3 were diagnostic angiograms. Five of 49 (10.2%) NIR patients reported skin/hair injuries, all of which were temporary. CONCLUSION: Software monitoring and documentation of radiation dose in interventional procedures can be successfully implemented. Radiation-induced tissue reactions are relatively uncommon.


Subject(s)
Radiation Dosage , Radiation Monitoring , Radiology, Interventional/methods , Software , Aftercare/methods , Female , Fluoroscopy/methods , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiation Monitoring/standards , Radiologic Health , Retrospective Studies
12.
J Am Coll Radiol ; 15(12): 1738-1744, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30149951

ABSTRACT

MRI is a ubiquitous medical imaging technology typically using superconductivity to generate a strong, homogeneous, and generally ceaseless magnetic field. MRI and its magnetic field pose many safety hazards, including magnetic forces on metals, tissue heating and burns, nerve stimulation, bioeffects, acoustic noise, and contrast agent complications. The primary concern is that a wide variety of patients, staff members, technologists, and physicians can approach the incessant magnetic field, creating great potential for accidents that could occur if metals from the environment, adornments, implants, and other unintended sources are also present in or near the field. Many accidents have occurred and are occasionally reported in the United States and countries all over the world. Through carefully structured oversight and the establishment of strict guidelines regarding access, responsibilities, and training, these risks can be mitigated, and accidents can be prevented. Fortunately, there is currently a wide variety of resources available to facilitate the successful implementation of an effective MRI safety program. This article presents a general overview of and the authors' experience with an MRI safety program in terms of risk management and training. The MR safety program requirements and regulations in the United States devised by The Joint Commission and the ACR are also discussed. With these resources and a carefully selected team, the risk for MRI-related accidents can be vastly reduced if not completely eliminated.


Subject(s)
Accident Prevention , Equipment Safety/standards , Magnetic Resonance Imaging/adverse effects , Patient Safety/standards , Risk Management/methods , Safety Management/standards , Contrast Media/adverse effects , Humans , Joint Commission on Accreditation of Healthcare Organizations , Prostheses and Implants/adverse effects , Societies, Medical , United States
13.
Radiology ; 289(2): 443-454, 2018 11.
Article in English | MEDLINE | ID: mdl-30015591

ABSTRACT

Purpose To investigate performance in detectability of small (≤1 cm) low-contrast hypoattenuating focal lesions by using filtered back projection (FBP) and iterative reconstruction (IR) algorithms from two major CT vendors across a range of 11 radiation exposures. Materials and Methods A low-contrast detectability phantom consisting of 21 low-contrast hypoattenuating focal objects (seven sizes between 2.4 and 10.0 mm, three contrast levels) embedded into a liver-equivalent background was scanned at 11 radiation exposures (volume CT dose index range, 0.5-18.0 mGy; size-specific dose estimate [SSDE] range, 0.8-30.6 mGy) with four high-end CT platforms. Data sets were reconstructed by using FBP and varied strengths of image-based, model-based, and hybrid IRs. Sixteen observers evaluated all data sets for lesion detectability by using a two-alternative-forced-choice (2AFC) paradigm. Diagnostic performances were evaluated by calculating area under the receiver operating characteristic curve (AUC) and by performing noninferiority analyses. Results At benchmark exposure, FBP yielded a mean AUC of 0.79 ± 0.09 (standard deviation) across all platforms which, on average, was approximately 2% lower than that observed with the different IR algorithms, which showed an average AUC of 0.81 ± 0.09 (P = .12). Radiation decreases of 30%, 50%, and 80% resulted in similar declines of observer detectability with FBP (mean AUC decrease, -0.02 ± 0.05, -0.03 ± 0.05, and -0.05 ± 0.05, respectively) and all IR methods investigated (mean AUC decrease, -0.00 ± 0.05, -0.04 ± 0.05, and -0.04 ± 0.05, respectively). For each radiation level and CT platform, variance in performance across observers was greater than that across reconstruction algorithms (P = .03). Conclusion Iterative reconstruction algorithms have limited radiation optimization potential in detectability of small low-contrast hypoattenuating focal lesions. This task may be further complicated by a high degree of variation in radiologists' performances, seemingly exceeding real performance differences among reconstruction algorithms. © RSNA, 2018 Online supplemental material is available for this article.


Subject(s)
Liver/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Observer Variation , Phantoms, Imaging , Radiation Dosage , Reproducibility of Results
16.
Cardiovasc Intervent Radiol ; 40(10): 1593-1599, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28497188

ABSTRACT

PURPOSE: To compare technical success, clinical success, complications, radiation dose, and total room utilization time for osteoid osteoma thermal (radiofrequency or microwave) ablation using cone-beam computed tomography (CBCT) with two-axis fluoroscopic navigational overlay versus conventional computed tomography (CT) guidance. MATERIALS AND METHODS: A retrospective review was performed to identify all osteoid osteoma ablations performed over a 5.5-year period at a single tertiary care pediatric hospital. Twenty-five ablations (15 radiofrequency and 10 microwave) in 23 patients undergoing fluoroscopic CBCT-guided osteoid osteoma ablation were compared to 35 ablations (35 radiofrequency) in 32 patients undergoing ablation via conventional CT guidance. Dose area product and dose length product were recorded for CBCT and conventional CT, respectively, and converted to effective doses. Technical success, clinical success (cessation of pain and medication use 1 month after ablation), complications, radiation dose, and total room utilization time were compared. RESULTS: All procedures were technically successful. Twenty-two of 25 (88.0%) CBCT and 31 of 35 (88.6%) conventional CT-guided ablations achieved immediate clinical success. There were two minor complications in each group and no major complications. Mean effective radiation dose was significantly lower for CBCT compared to CT guidance (0.12 vs. 0.39 mSv, p = 0.02). Mean total room utilization time for CBCT was longer (133.5 vs. 97.5 min, p = 0.0001). CONCLUSIONS: Fluoroscopic CBCT guidance for percutaneous osteoid osteoma ablation yields similar technical and clinical success, reduced radiation dose, and increased total room utilization time compared to conventional CT guidance.


Subject(s)
Bone Neoplasms/surgery , Catheter Ablation/methods , Osteoma, Osteoid/surgery , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Bone Neoplasms/diagnostic imaging , Child , Child, Preschool , Cone-Beam Computed Tomography/methods , Female , Fluoroscopy/methods , Humans , Male , Osteoma, Osteoid/diagnostic imaging , Pediatrics/methods , Retrospective Studies , Young Adult
17.
Radiology ; 284(1): 120-133, 2017 07.
Article in English | MEDLINE | ID: mdl-28221093

ABSTRACT

Purpose To develop diagnostic reference levels (DRLs) and achievable doses (ADs) for the 10 most common adult computed tomographic (CT) examinations in the United States as a function of patient size by using the CT Dose Index Registry. Materials and Methods Data from the 10 most commonly performed adult CT head, neck, and body examinations from 583 facilities were analyzed. For head examinations, the lateral thickness was used as an indicator of patient size; for neck and body examinations, water-equivalent diameter was used. Data from 1 310 727 examinations (analyzed by using SAS 9.3) provided median values, as well as means and 25th and 75th (DRL) percentiles for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE). Applicable results were compared with DRLs from eight countries. Results More than 46% of the facilities were community hospitals; 13% were academic facilities. More than 48% were in metropolitan areas, 39% were suburban, and 13% were rural. More than 50% of the facilities performed fewer than 500 examinations per month. The abdomen and pelvis was the most frequently performed examination in the study (45%). For body examinations, DRLs (75th percentile) and ADs (median) for CTDIvol, SSDE, and DLP increased consistently with the patient's size (water-equivalent diameter). The relationships between patient size and DRLs and ADs were not as strong for head and neck examinations. These results agree well with the data from other countries. Conclusion DRLs and ADs as a function of patient size were developed for the 10 most common adult CT examinations performed in the United States. © RSNA, 2017.


Subject(s)
Radiation Dosage , Tomography, X-Ray Computed , Adult , Contrast Media , Female , Humans , Male , Phantoms, Imaging , Reference Values , United States
18.
Clin Imaging ; 40(6): 1213-1218, 2016.
Article in English | MEDLINE | ID: mdl-27616154

ABSTRACT

PURPOSE: This study aims to compare transcatheter aortic valve replacement (TAVR) planning on 16 cm wide-detector computed tomography (CT) to TAVR planning on 4 cm detector CT. MATERIALS AND METHODS: A total of 36 patients who had TAVR planning axial CT on a wide-detector scanner (protocol 1) were compared to 36 patients who had helical 4 cm detector CT (protocol 2). RESULTS: Vascular attenuation was greater for protocol 1, but image noise, contrast-to-noise ratio, and signal-to-noise ratio were the same. Radiation dose was lower and iodine dose was less for protocol 1. CONCLUSION: Protocol 1 had greater vascular attenuation and similar image quality but lower radiation and less iodine compared to protocol 2.


Subject(s)
Contrast Media/administration & dosage , Image Enhancement , Iodine/administration & dosage , Radiation Dosage , Tomography, Spiral Computed/methods , Tomography, X-Ray Computed/methods , Transcatheter Aortic Valve Replacement , Aged , Female , Humans , Male , Retrospective Studies , Signal-To-Noise Ratio
19.
AJR Am J Roentgenol ; 207(5): 1039-1045, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27556580

ABSTRACT

OBJECTIVE: The purpose of this article is to illustrate the use of the American College of Radiology Dose Index Registry data with a novel measurement of exposure to guide quality improvement efforts. MATERIALS AND METHODS: Using information from the Dose Index Registry report covering July through December 2012, we examined our relative ranking compared with the national median CT dose for the 20 most frequently performed examinations at our institution. The total exposure variance, defined as the difference between institutional and median national dose multiplied by the local examination frequency and expressed in units of mGy-persons, was calculated. Using this metric, two examinations were selected for investigation: pulmonary and thoracic CT angiography (CTA). Protocol modifications were implemented, and postintervention dose data were assessed from the report 1 year later. RESULTS: As indicated by size-specific dose estimates (SSDEs), the 2012 pulmonary CTA was within the national interquartile range; however, total exposure variance analysis showed that it presented the greatest opportunity for improvement on a population basis. Thoracic CTA was a top quartile examination and offered the second highest potential savings. After protocol modification, the average pulmonary CTA SSDEs decreased by 16%, for a population exposure savings of 1776 mGy-persons in the 2013 report. Average thoracic CTA SSDEs decreased by 44%, for a population exposure savings of 1050 mGy-persons. CONCLUSION: Total exposure variance analysis can increase the usefulness of Dose Index Registry data by relating per-examination dose differences to the local examination frequency. This study exhibited reduction of dose metrics for two commonly performed examinations.


Subject(s)
Angiography , Computed Tomography Angiography , Radiation Dosage , Radiography, Thoracic , Female , Humans , Male , Quality Improvement , Registries , United States
20.
Acad Emerg Med ; 22(12): 1499-505, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26568459

ABSTRACT

OBJECTIVES: The objective was to evaluate variation in the current estimated radiation dose index for pediatric cervical spine (c-spine) computed tomography (CT) examinations. METHODS: This was a retrospective analysis of pediatric (age younger than 19 years) c-spine CT examinations from the American College of Radiology Dose Index Registry, July 2011 through December 2014. We used the volume CT dose index (CTDIvol) as the radiation dose estimate and used summary statistics to describe patient and hospital characteristics. RESULTS: There were 12,218 pediatric CT c-spine examinations performed across 296 participating hospitals. Fifty-six percent were in male patients, and 79% were in children older than 10 years. Most hospitals (55%) were community hospitals without trauma designations, and the largest proportion of examinations (41%) were performed at these hospitals. The median CTDIvol was 15 mGy (interquartile range = 9 to 23 mGy) representing a more than 2.5-fold difference between the 25th and 75th percentiles. Pediatric hospitals (both trauma and nontrauma centers) delivered the lowest CTDIvol across all age groups and showed the least amount of variability in dose. CONCLUSIONS: There is significant variation in the radiation dose index for pediatric c-spine CT examinations. Pediatric hospitals practice at lower CT dose estimates than other hospitals. Individual hospitals should examine their practices in an effort to ensure standardization and optimization of CT parameters to minimize radiation exposures to pediatric patients.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Hospitals, Community/statistics & numerical data , Hospitals, Pediatric/statistics & numerical data , Radiation Dosage , Tomography, X-Ray Computed/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Neck/diagnostic imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...