Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Pain Manag ; 12(8): 951-960, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36193759

ABSTRACT

Aim: Complex regional pain syndrome (CRPS) is a debilitating, painful condition of limbs that often arises after an injury and is associated with significant morbidity. Materials & methods: The Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument, used to assess the quality of clinical practice guidelines (CPGs), was used to evaluate seven CRPS management guideline. Results: Out of the seven CPGs evaluated using the AGREE II instrument, only one from Royal College of Physicians was found to have high-quality consensus guidelines for diagnosis and management of CRPS. Conclusion: Future CPGs should be backed by systematic literature searches, focus on guidelines clinical translation into clinical practice and applicability to the desired patient population.


Subject(s)
Complex Regional Pain Syndromes , Humans , Complex Regional Pain Syndromes/diagnosis , Complex Regional Pain Syndromes/therapy , Consensus
2.
Circ Cardiovasc Imaging ; 10(8)2017 Aug.
Article in English | MEDLINE | ID: mdl-28790123

ABSTRACT

BACKGROUND: Patients with obstructive (≥50% stenosis) left main (LM) coronary artery disease (CAD) are at high risk for adverse events; prior studies have also documented worse outcomes among women than men with severe multivessel/LM CAD. However, the prognostic significance of nonobstructive (1%-49% stenosis) LM CAD, including sex-specific differences, has not been previously examined. METHODS AND RESULTS: In the long-term CONFIRM (Coronary CT Angiography Evaluation For Clinical Outcomes: An International Multicenter) registry, patients underwent elective coronary computed tomographic angiography for suspected CAD and were followed for 5 years. After excluding those with obstructive LM CAD, 5166 patients were categorized as having normal LM or nonobstructive LM (18% of cohort). Cumulative 5-year incidence of death, myocardial infarction, or revascularization was higher among patients with nonobstructive LM than normal LM in both women and men: women (34.3% versus 15.4%; P<0.0001); men (24.6% versus 18.2%; P<0.0001). A significant interaction existed between sex and LM status for the composite outcome (P=0.001). In multivariable Cox regression, the presence of nonobstructive LM plaque increased the risk for the composite outcome in women (adjusted hazard ratio, 1.48; P=0.005) but not in men (adjusted hazard ratio, 0.98, P=0.806). In subgroup analysis, women with nonobstructive LM CAD had a nearly 80% higher risk for events than men with nonobstructive LM CAD (adjusted hazard ratio, 1.78; P=0.017); sex-specific interactions were not observed across other patterns (eg, location or extent) of nonobstructive plaque. CONCLUSION: Nonobstructive LM CAD was frequently detected on coronary computed tomographic angiography and strongly associated with adverse events among women. Recognizing the sex-specific prognostic significance of nonobstructive LM plaque may augment risk stratification efforts.


Subject(s)
Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Health Status Disparities , Aged , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Coronary Stenosis/mortality , Coronary Stenosis/therapy , Disease Progression , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Revascularization , Predictive Value of Tests , Prognosis , Proportional Hazards Models , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Sex Factors , Time Factors
3.
Ochsner J ; 15(2): 191-2, 2015.
Article in English | MEDLINE | ID: mdl-26130985

ABSTRACT

BACKGROUND: Peripheral nerve injury is a common result of trauma. In cases of nerve gap, treatment may involve placement of a nerve conduit. This case involves a polyglycolic acid nerve conduit tube that was extruded through soft tissue. To our knowledge, this reactive process has only been previously documented in one article. This complication is not commonly known among hand surgeons, hence our interest in documenting it. CASE REPORT: We present the case of a 33-year-old male who injured his right nondominant thumb in a workplace saw accident. His complex wound involved the radial digital nerve, and the nerve was repaired using a polyglycolic acid nerve conduit. By postoperative week 4, part of the nerve conduit was extruding through the wound. No signs of infection were noted, and the remainder of his wounds had healed. The patient declined a nerve graft, so his wound was debrided with no further attempts at nerve repair. The wound healed uneventfully, and the patient returned to full duty without restrictions. CONCLUSION: We believe this is the first documented case of extrusion of a nerve conduit through healthy soft tissue. Recent advancements in nerve allografts and conduits hold promise but are not yet in widespread use. We recommend the use of a collagen conduit to avoid extrusion of polyglycolic acid-based materials.

4.
J Orthop Trauma ; 29(10): e380-4, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25932527

ABSTRACT

PURPOSE: Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. METHODS: One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. RESULTS: The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). CONCLUSIONS: The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.


Subject(s)
Bone Nails , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Knee Injuries/diagnostic imaging , Knee Injuries/surgery , Aged , Aged, 80 and over , Equipment Failure Analysis , Female , Fracture Fixation, Intramedullary/methods , Humans , Male , Middle Aged , Prosthesis Design , Radiography , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...