EJNMMI Phys ; 10(1): 38, 2023 Jun 16.
Article in English | MEDLINE | ID: mdl-37322376

ABSTRACT

BACKGROUND: This study evaluated, as a snapshot, the variability in quantification and image quality (IQ) of the clinically utilized PET [18F]FDG whole-body protocols in Finland using a NEMA/IEC IQ phantom permanently filled with 68Ge. METHODS: The phantom was imaged on 14 PET-CT scanners, including a variety of models from two major vendors. The variability of the recovery coefficients (RCmax, RCmean and RCpeak) of the hot spheres as well as percent background variability (PBV), coefficient of variation of the background (COVBG) and accuracy of corrections (AOC) were studied using images from clinical and standardized protocols with 20 repeated measurements. The ranges of the RCs were also compared to the limits of the EARL 18F standards 2 accreditation (EARL2). The impact of image noise on these parameters was studied using averaged images (AVIs). RESULTS: The largest variability in RC values of the routine protocols was found for the RCmax with a range of 68% and with 10% intra-scanner variability, decreasing to 36% when excluding protocols with suspected cross-calibration failure or without point-spread-function (PSF) correction. The RC ranges of individual hot spheres in routine or standardized protocols or AVIs fulfilled the EARL2 ranges with two minor exceptions, but fulfilling the exact EARL2 limits for all hot spheres was variable. RCpeak was less dependent on averaging and reconstruction parameters than RCmax and RCmean. The PBV, COVBG and AOC varied between 2.3-11.8%, 9.6-17.8% and 4.8-32.0%, respectively, for the routine protocols. The RC ranges, PBV and COVBG were decreased when using AVIs. With AOC, when excluding routine protocols without PSF correction, the maximum value dropped to 15.5%. CONCLUSION: The maximum variability of the RC values for the [18F]FDG whole-body protocols was about 60%. The RC ranges of properly cross-calibrated scanners with PSF correction fitted to the EARL2 RC ranges for individual sphere sizes, but fulfilling the exact RC limits would have needed further optimization. RCpeak was the most robust RC measure. Besides COVBG, also RCs and PVB were sensitive to image noise.

3.
Phys Med Biol ; 51(12): 3269-82, 2006 Jun 21.
Article in English | MEDLINE | ID: mdl-16757876

ABSTRACT

Multi-slice CT provides an efficient imaging modality for trauma imaging. The purpose of this study was to provide absorbed and effective dose data from CT taking into account the patient size and compare such doses with the standard CT dose quantities based on standard geometry. The CT examination data from abdominal and thoracic scan series were collected from 36 trauma patients. The CTDI(vol), DLP(w) and effective dose were determined, and the influence of patient size was applied as a correction factor to calculated doses. The patient size was estimated from the patient weight as the effective radius based on the analysis from the axial images of abdominal and thoracic regions. The calculated mean CTDI(vol), DLP(w) and effective dose were 15.2 mGy, 431 mGy cm and 6.5 mSv for the thorax scan, and 18.5 mGy, 893 mGy cm and 14.8 mSv for the abdomen scan, respectively. The doses in the thorax and abdomen scans taking the patient size into account were 34% and 9% larger than the standard dose quantities, respectively. The use of patient size in dose estimation is recommended in order to provide realistic data for evaluation of the radiation exposure in CT, especially for paediatric patients and smaller adults.


Subject(s)
Body Size , Environmental Exposure/statistics & numerical data , Radiation Injuries/prevention & control , Radiography, Abdominal/statistics & numerical data , Radiography, Thoracic/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Wounds and Injuries/epidemiology , Body Burden , Environmental Exposure/analysis , Female , Finland/epidemiology , Humans , Male , Models, Biological , Radiation Dosage , Radiation Injuries/epidemiology , Radiation Protection/methods , Risk Assessment/methods , Statistics as Topic
4.
Eur J Radiol ; 56(2): 154-9, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16233888

ABSTRACT

This article summarizes the current status of 1H MRS in detecting and quantifying a boron neutron capture therapy (BNCT) boron carrier, L-p-boronophenylalanine-fructose (BPA-F) in vivo in the Finnish BNCT project. The applicability of 1H MRS to detect BPA-F is evaluated and discussed in a typical situation with a blood containing resection cavity within the gross tumour volume (GTV). 1H MRS is not an ideal method to study BPA concentration in GTV with blood in recent resection cavity. For an optimal identification of BPA signals in the in vivo 1H MR spectrum, both pre- and post-infusion 1H MRS should be performed. The post-infusion spectroscopy studies should be scheduled either prior to or, less optimally, immediately after the BNCT. The pre-BNCT MRS is necessary in order to utilise the MRS results in the actual dose planning.


Subject(s)
Boron Compounds/blood , Boron Neutron Capture Therapy , Fructose/analogs & derivatives , Magnetic Resonance Spectroscopy/methods , Adult , Aged , Boron/therapeutic use , Boron Compounds/analysis , Brain Neoplasms/pathology , Brain Neoplasms/radiotherapy , Carcinoma/pathology , Carcinoma/radiotherapy , Female , Finland , Fructose/analysis , Fructose/blood , Glioblastoma/pathology , Glioblastoma/radiotherapy , Humans , Hydrogen , Isotopes/therapeutic use , Male , Neoplasm Recurrence, Local/pathology , Neoplasm Recurrence, Local/radiotherapy , Paranasal Sinus Neoplasms/pathology , Paranasal Sinus Neoplasms/radiotherapy , Phantoms, Imaging , Plasma , Radiopharmaceuticals/therapeutic use
5.
Phys Med Biol ; 48(17): 2895-906, 2003 Sep 07.
Article in English | MEDLINE | ID: mdl-14516107

ABSTRACT

Polymer gels have been reported as a new, potential tool for dosimetry in mixed neutron-gamma radiation fields. In this work, BANG-3 (MGS Research Inc.) gel vials from three production batches were irradiated with 6 MV photons of a Varian Clinac 2100 C linear accelerator and with the epithermal neutron beam of the Finnish boron neutron capture therapy (BNCT) facility at the FiR 1 nuclear reactor. The gel is tissue equivalent in main elemental composition and density and its T2 relaxation time is dependent on the absorbed dose. The T2 relaxation time map of the irradiated gel vials was measured with a 1.5 T magnetic resonance (MR) scanner using spin echo sequence. The absorbed doses of neutron irradiation were calculated using DORT computer code, and the accuracy of the calculational model was verified by measuring gamma ray dose rate with thermoluminescent dosimeters and 55Mn(n,gamma) activation reaction rate with activation detectors. The response of the BANG-3 gel dosimeter for total absorbed dose in the neutron irradiation was linear, and the magnitude of the response relative to the response in the photon irradiation was observed to vary between different gel batches. The results support the potential of polymer gels in BNCT dosimetry, especially for the verification of two- or three-dimensional dose distributions.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Gels , Polymers , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/instrumentation , Boron Neutron Capture Therapy/methods , Dose-Response Relationship, Radiation , Equipment Failure Analysis , Neutrons/therapeutic use , Radiation Dosage , Radiometry/standards , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity
6.
Phys Med Biol ; 48(8): 1027-39, 2003 Apr 21.
Article in English | MEDLINE | ID: mdl-12741499

ABSTRACT

The quantification of a BNCT 10B-carrier, L-p-boronophenylalanine-fructose complex (BPA-F), was evaluated using 1H magnetic resonance spectroscopy (1H MRS) with phantoms at 1.5 and 3.0 T. For proper quantification, relaxation times T1 and T2 are needed. While T1 is relatively easy to determine, the determination of T2 of a coupled spin system of aromatic protons of BPA is not straightforward with standard MRS sequences. In addition, an uncoupled concentration reference for aromatic protons of BPA must be used with caution. In order to determine T2, the response of an aromatic proton spin system to the MRS sequence PRESS with various echo times was calculated and the product of the response curve with exponential decay was fitted to the measured intensities. Furthermore, the response curve can be used to correct the intensities, when an uncoupled resonance is used as a concentration reference. BPA was quantified using both phantom replacement and internal water referencing methods with accuracies of +/- 5% and +/- 15%. Our phantom results suggest that in vivo studies on BPA concentration determination will be feasible.


Subject(s)
Boron Compounds/analysis , Boron Neutron Capture Therapy/methods , Magnetic Resonance Spectroscopy/methods , Phenylalanine/analogs & derivatives , Phenylalanine/analysis , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Boron Compounds/therapeutic use , Computer Simulation , Dose-Response Relationship, Radiation , Feasibility Studies , Magnetic Resonance Spectroscopy/instrumentation , Models, Theoretical , Phantoms, Imaging , Phenylalanine/therapeutic use , Protons , Radiotherapy Dosage
7.
Phys Rev C Nucl Phys ; 50(3): 1370-1376, 1994 Sep.
Article in English | MEDLINE | ID: mdl-9969797
8.
Phys Rev C Nucl Phys ; 47(1): 145-156, 1993 Jan.
Article in English | MEDLINE | ID: mdl-9968419
9.
Phys Rev C Nucl Phys ; 43(5): 2162-2171, 1991 May.
Article in English | MEDLINE | ID: mdl-9967267