Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomed Opt ; 18(1): 16013, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23334688

ABSTRACT

Ultrathin flexible fiberscopes typically have separate illumination and imaging channels and are available in diameters ranging from 0.5 to 2.5 mm. Diameters can potentially be reduced by combining the illumination and imaging paths into a single fiberoptic channel. Single-channel fiberscopes must incorporate a system to minimize Fresnel reflections from air-glass interfaces within the common illumination and detection path. The Fresnel reflection at the proximal surface of the fiber bundle is particularly problematic. This paper describes and compares methods to reduce the background signal from the proximal surface of the fiber bundle. Three techniques are evaluated: (1) antireflective (AR)-coating the proximal face of the fiber, (2) incorporating crossed polarizers into the light path, and (3) a novel technique called numerical aperture sharing, whereby a portion of the image numerical aperture is devoted to illumination and a portion to detection.


Subject(s)
Endoscopes , Endoscopy/instrumentation , Fiber Optic Technology/instrumentation , Computer Simulation , Equipment Design , Signal Processing, Computer-Assisted
2.
Appl Opt ; 47(25): 4560-8, 2008 Sep 01.
Article in English | MEDLINE | ID: mdl-18758526

ABSTRACT

The emission and transmission properties of three commercially produced coherent fiber optic imaging bundles were evaluated. Full fluorescence excitation versus emission data were collected from 250 to 650 nm excitation for high-resolution Sumitomo, Fujikura, and Schott fiber bundles. The results generated show regions of autofluorescence and inelastic Raman scattering in the imaging bundles that represent a wavelength-dependent background signal when these fibers are used for imaging applications. The high-resolution fiber bundles also exhibit significant variation in transmission with the angle of illumination, which affects the overall coupling and transmission efficiency. Knowledge of these properties allows users of high-resolution imaging bundles to optimally design systems that utilize such bundles.


Subject(s)
Fiber Optic Technology/instrumentation , Microscopy, Fluorescence/instrumentation , Equipment Design , Equipment Failure Analysis , Optical Fibers , Scattering, Radiation
3.
Appl Opt ; 43(31): 5763-71, 2004 Nov 01.
Article in English | MEDLINE | ID: mdl-15540433

ABSTRACT

The fluorescence confocal microendoscope provides high-resolution, in vivo imaging of cellular pathology during optical biopsy. The confocal microendoscope employs a flexible fiber-optic catheter coupled to a custom-built slit-scan confocal microscope. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The 3-mm-diameter catheter may be used on its own or routed though the instrument channel of a commercial endoscope, adding microscopic imaging capability to conventional endoscopy. The design and performance of the miniature objective and focus assembly are discussed. Primary applications of the system include diagnosis of disease in the gastrointestinal tract and female reproductive system.


Subject(s)
Catheterization/instrumentation , Endoscopes , Equipment Failure Analysis , Gastrointestinal Diseases/pathology , Genital Diseases, Female/pathology , Microscopy, Confocal/instrumentation , Equipment Design , Feasibility Studies , Female , Humans , Miniaturization/methods , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...