Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 154
Filter
1.
Rev Sci Instrum ; 93(5): 053301, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35649793

ABSTRACT

A beam optics study using the ITER-relevant high intense negative ion beams, such as 1 MeV, 200 A/m2, has been performed experimentally and analytically using a multi-aperture and five-stage accelerator. Initially, multi-beamlets generated from this accelerator were deflected in various directions due to the magnetic field and space charge repulsion between beams and showed various divergences. These had limited the pulse length and the beam energy. Compensation methods of the beamlet deflections have worked effectively and contributed to achieving the ITER requirement, the divergence angle of <7 mrad, and the deflection angle of <1 mrad for 1 MeV beam. The beam pulse has been gradually extended from 1 to 100 s and is now going to a longer pulse based on these results. One of the remaining issues is to understand and suppress peripheral components of the beam, namely, the halo, and to reduce the local heat loads observed around the aperture edge. This halo component has been successfully distinguished from the beam core by using a newly developed beam emittance measurement system for high intense beams. By combining this measured beam emittance and the beam simulation, it was clarified for the first time that the halo components are generated in an area of 1 mm width from the aperture edge.

3.
Rev Sci Instrum ; 91(3): 033313, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-32259933

ABSTRACT

To realize stable negative ion beams for 100 s required in the neutral beam injector of JT-60SA, a physical model to control cesium (Cs) distribution inside the negative ion source has been developed in order to maintain the stable negative ion production at the plasma grid (PG) surface with Cs. In this work, to quantitatively evaluate Cs coverage on the PG, a three-dimensional Cs transportation code was introduced to consider the spatial Cs distribution in the source. The spatial temperature distribution of the chamber wall was also introduced in this model. As a result, the reasonable variation of the Cs coverage for 100 s was obtained, compared to that in the initial model. Based on the modified model, the operational temperature of the chamber wall was proposed to be less than 60 °C to suppress the desorption of Cs in the chamber wall and to sustain the stable negative ion production. In addition, it was also suggested that a slightly higher wall temperature before the operation leads to a decrease in the amount of Cs stored at the chamber wall, resulting in suppression of Cs consumption in the ion source.

4.
Rev Sci Instrum ; 91(2): 023506, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113410

ABSTRACT

Long pulse acceleration of hydrogen negative ion beams with the power density over 70 MW/m2 and the pulse length over 100 s has been demonstrated for the first time by using a multi-aperture 3-stage accelerator. Such long pulse acceleration was achieved by integrating the design of beam optics and voltage holding capability to meet the requirements of JT-60SA. By using the newly designed accelerator for JT-60SA, voltage holding at 500 kV with beam acceleration was stably sustained even after 5 g of cesium was seeded, and heat load on each acceleration grid was reduced below the allowable level for long pulse, less than 5% of total acceleration power. As a result, 500 keV, 154 A/m2 for 118 s beam acceleration was achieved, which satisfies the requirement of the negative ion source for JT-60SA. This pulse length of such high-power density beams is longest in the world. In addition, the result contributes to the long pulse acceleration of multi-stage electrostatic accelerators, such as 1 MeV negative ion accelerator for ITER.

5.
J Assist Reprod Genet ; 36(11): 2251-2257, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31691057

ABSTRACT

PURPOSE: A radiofrequency identification (RFID) tag system was designed to streamline cryopreservation and thawing procedures. This study evaluated the usefulness of the RFID tag system for improving the efficiency of cryopreserving/thawing bovine ovarian tissue by the closed vitrification protocol. METHODS: Six participants carried out closed vitrification and thawing of bovine ovarian tissues procedures using either the conventional or the new RFID tag method, and the time required to perform each step of the respective methods was measured. After normality of data was confirmed by the Shapiro-Wilk test, the significance of differences was assessed by the unpaired t test. RESULTS: When closed vitrification was performed, the time required for each step showed a significant difference between the two methods (t(4) = 2.938, p = 0.042, d = 2.40), and the total cryopreservation time was 11 min shorter using the RFID tag system. When thawing was performed, the time required for each step also showed a significant difference between the two methods (t(4) = 2.797, p = 0.049, d = 2.28), and the total thawing time was 2 min shorter using the RFID tag system. CONCLUSION: The RFID tag system tested in this study seems to be suitable for managing biological samples stored in liquid nitrogen. Adoption of an RFID tag system by fertility centers may not only improve the efficiency of cryopreserving/thawing reproductive tissues but could also reduce human error.


Subject(s)
Cryopreservation/methods , Ovary/physiology , Radio Frequency Identification Device/methods , Animals , Cattle , Cryoprotective Agents/pharmacology , Female , Fertility/drug effects , Fertility/physiology , Oocytes/drug effects , Oocytes/physiology , Ovary/drug effects , Reproduction/drug effects , Reproduction/physiology , Vitrification
6.
Transl Psychiatry ; 7(2): e1047, 2017 02 28.
Article in English | MEDLINE | ID: mdl-28244984

ABSTRACT

In understanding the mechanism of schizophrenia pathogenesis, a significant finding is that drug abuse of phencyclidine or its analog ketamine causes symptoms similar to schizophrenia. Such drug effects are triggered even by administration at post-adolescent stages. Both drugs are N-methyl-d-aspartate receptor (NMDAR) antagonists, leading to a major hypothesis that glutamate hypofunction underlies schizophrenia pathogenesis. The precise region that depends on NMDAR function, however, is unclear. Here, we developed a mouse strain in which NMDARs in the intralaminar thalamic nuclei (ILN) were selectively disrupted. The mutant mice exhibited various schizophrenia-like phenotypes, including deficits in working memory, long-term spatial memory, and attention, as well as impulsivity, impaired prepulse inhibition, hyperlocomotion and hyperarousal. The electroencephalography analysis revealed that the mutant mice had a significantly reduced power in a wide range of frequencies including the alpha, beta and gamma bands, both during wake and rapid eye movement (REM) sleep, and a modest decrease of gamma power during non-REM sleep. Notably, restoring NMDARs in the adult ILN rescued some of the behavioral abnormalities. These findings suggest that NMDAR dysfunction in the ILN contributes to the pathophysiology of schizophrenia-related disorders. Furthermore, the reversal of inherent schizophrenia-like phenotypes in the adult mutant mice supports that ILN is a potential target site for a therapeutic strategy.


Subject(s)
Behavior, Animal , Intralaminar Thalamic Nuclei/metabolism , Nerve Tissue Proteins/genetics , Receptors, N-Methyl-D-Aspartate/genetics , Schizophrenia/genetics , Animals , Arousal , Attention , Disease Models, Animal , Electroencephalography , Genetic Therapy , Impulsive Behavior , Locomotion , Male , Maze Learning , Memory, Short-Term , Mice , Mice, Transgenic , Mutation , Phenotype , Prepulse Inhibition , Schizophrenia/metabolism , Schizophrenia/physiopathology , Schizophrenic Psychology , Spatial Memory
7.
Rev Sci Instrum ; 87(2): 02B144, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26932026

ABSTRACT

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

8.
Rev Sci Instrum ; 87(2): 02B304, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26932032

ABSTRACT

Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.

9.
Rev Sci Instrum ; 87(2): 02B322, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26932050

ABSTRACT

In order to realize negative ion sources and accelerators to be applicable to International Thermonuclear Experimental Reactor and JT-60 Super Advanced, a large cesium (Cs)-seeded negative ion source and a multi-aperture and multi-stage electric acceleration have been developed at Japan Atomic Energy Agency (JAEA). Long pulse production and acceleration of the negative ion beams have been independently carried out. The long pulse production of the high current beams has achieved 100 s at the beam current of 15 A by modifying the JT-60 negative ion source. The pulse duration time is increased three times longer than that before the modification. As for the acceleration, a pulse duration time has been also extended two orders of magnitudes from 0.4 s to 60 s. The developments of the negative ion source and acceleration at JAEA are well in progress towards the realization of the negative ion sources and accelerators for fusion applications.

10.
Anaesthesia ; 69(5): 468-75, 2014 May.
Article in English | MEDLINE | ID: mdl-24601902

ABSTRACT

Doxapram is the only dedicated respiratory stimulant used to aid recovery of breathing after major surgery. Doxapram acts on peripheral chemoreceptors and although the central action of doxapram has been suggested, its detailed neuronal mechanism is unknown. We assessed doxapram-induced changes in spontaneous cervical nerve (C4) inspiratory activity and the firing of action potentials in pre-inspiratory and inspiratory neurones in the medulla. Experiments were performed in neonatal rat brainstem-spinal cord preparations, which can produce respiratory rhythm for several hours under in vitro conditions. Doxapram application (for 15 min) increased the frequency and amplitude of C4 activity dose-dependently. Doxapram induced changes in the electrophysiological properties of pre-inspiratory and inspiratory neurones. Our results suggest that respiratory activity enhancement was likely to be induced via effects on the potassium channels of pre-inspiratory and inspiratory neurones and indicate the central actions of doxapram.


Subject(s)
Brain Stem/drug effects , Doxapram/pharmacology , Neurons/drug effects , Respiratory Mechanics/drug effects , Respiratory System Agents/pharmacology , Spinal Cord/drug effects , Animals , Animals, Newborn , Dose-Response Relationship, Drug , Medulla Oblongata/drug effects , Rats , Rats, Wistar
11.
Rev Sci Instrum ; 85(2): 02B125, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593565

ABSTRACT

The purpose of this study is to calculate atomic (H(0)) density distribution in JAEA 10 ampere negative ion source. A collisional radiative model is developed for the calculation of the H(0) density distribution. The non-equilibrium feature of the electron energy distribution function (EEDF), which mainly determines the H(0) production rate, is included by substituting the EEDF calculated from 3D electron transport analysis. In this paper, the H(0) production rate, the ionization rate, and the density distribution in the source chamber are calculated. In the region where high energy electrons exist, the H(0) production and the ionization are enhanced. The calculated H(0) density distribution without the effect of the H(0) transport is relatively small in the upper region. In the next step, the effect should be taken into account to obtain more realistic H(0) distribution.

12.
Rev Sci Instrum ; 85(2): 02B304, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593581

ABSTRACT

In order to realize neutral beam systems in International Thermonuclear Experimental Reactor whose target is to produce a 1 MeV, 200 A/m(2) during 3600 s D(-) ion beam, the electrostatic five-stages negative ion accelerator so-called "MeV accelerator" has been developed at Japan Atomic Energy Agency. To extend pulse length, heat load of the acceleration grids was reduced by controlling the ion beam trajectory. Namely, the beam deflection due to the residual magnetic field of filter magnet was suppressed with the newly developed extractor with a 0.5 mm off-set aperture displacement. The new extractor improved the deflection angle from 6 mrad to 1 mrad, resulting in the reduction of direct interception of negative ions from 23% to 15% of the total acceleration power, respectively. As a result, the pulse length of 130 A/m(2), 881 keV H(-) ion beam has been successfully extended from a previous value of 0.4 s to 8.7 s. This is the first long pulse negative ion beam acceleration over 100 MW/m(2).

13.
Rev Sci Instrum ; 85(2): 02B312, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593589

ABSTRACT

Long pulse beam extraction with a current density of 120 A/m(2) for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m(2) (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.

14.
Rev Sci Instrum ; 85(2): 02B320, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593597

ABSTRACT

High power and long-pulse negative ion extractor, which is composed of the plasma grid (PG) and the extraction grid (EXG), is newly developed toward the neutral beam injector for heating and current drive of future fusion machines such as ITER, JT-60 Super Advanced and DEMO reactor. The PG is designed to enhance surface production of negative ions efficiently by applying the chamfered aperture. The efficiency of the negative ion production for the discharge power increased by a factor of 1.3 against that of the conventional PG. The EXG is also designed with the thermal analysis to upgrade the cooling capability for the long pulse operation of >1000 s required in ITER. Though the magnetic field for electron suppression is reduced to 0.75 of that in the conventional EXG due to this upgrade, it was experimentally confirmed that the extracted electron current can be suppressed to the allowable level for the long pulse operation. These results show that newly developed extractor has the high potential for the long pulse extraction of the negative ions.

15.
Rev Sci Instrum ; 83(2): 02A719, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380228

ABSTRACT

Spatially non-uniform electron energy distribution function (EEDF) in an arc driven negative ion source (JAEA 10A negative ion source: 10 A NIS) is calculated numerically by a three-dimensional Monte Carlo kinetic model for electrons to understand spatial distribution of plasma production (such as atomic and ionic hydrogen (H(0)∕H(+)) production) in source chamber. The local EEDFs were directly calculated from electron orbits including electromagnetic effects and elastic∕inelastic collision forces. From the EEDF, spatial distributions of H(0)∕H(+) production rate were obtained. The results suggest that spatial non-uniformity of H(0)∕H(+) productions is enhanced by high energy component of EEDF.

16.
Rev Sci Instrum ; 83(2): 02B102, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380259

ABSTRACT

The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1∕3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 µP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D(+):D(2)(+):D(3)(+) = 75:20:5 at beam current density of 85 mA/cm(2). The arc efficiency is more than 1.0 A∕kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T(i) and T(e) profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

17.
Rev Sci Instrum ; 83(2): 02B117, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380274

ABSTRACT

Vacuum insulation on a large size negative ion accelerator with multiple extraction apertures and acceleration grids for fusion application was experimentally examined and designed. In the experiment, vacuum insulation characteristics were investigated in the JT-60 negative ion source with >1000 apertures on the grid with the surface area of ∼2 m(2). The sustainable voltages varied with a square root of the gap lengths between the grids, and decreased with number of the apertures and with the surface area of the grids. Based on the obtained results, the JT-60SA (super advanced) negative ion source is designed to produce 22 A, 500 keV D(-) ion beams for 100 s.

18.
Rev Sci Instrum ; 83(2): 02B119, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380276

ABSTRACT

In a multi-aperture multi-grid accelerator of the ITER neutral beam injector, the beamlets are deflected due to space charge repulsion between beamlets and beam groups, and also due to magnetic field. Moreover, the beamlet deflection is influenced by electric field distortion generated by grid support structure. Such complicated beamlet deflections and the compensations have been examined utilizing a three-dimensional beam analysis. The space charge repulsion and the influence by the grid support structure were studied in a 1∕4 model of the accelerator including 320 beamlets. Beamlet deflection due to the magnetic field was studied by a single beamlet model. As the results, compensation methods of the beamlet deflection were designed, so as to utilize a metal bar (so-called field shaping plate) of 1 mm thick beneath the electron suppression grid (ESG), and an aperture offset of 1 mm in the ESG.

19.
Rev Sci Instrum ; 83(2): 02B121, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380278

ABSTRACT

Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration, which leads to discharge initiation at lower voltage. To reduce the electric field concentration in the MeV accelerator, gaps between the grid supports were expanded and curvature radii at the support corners were increased. After the modifications, the accelerator succeeded in sustaining -1 MV in vacuum without beam acceleration. However, the beam energy was still limited at a level of 900 keV with a beam current density of 150 A∕m(2) (346 mA) where the 3 × 5 apertures were used. Measurement of the beam profile revealed that deflection of the H(-) ions was large and a part of the H(-) ions was intercepted at the acceleration grid. This causes high heat load on the grids and the breakdowns during beam acceleration. To suppress the direct interception, new grid system was designed with proper aperture displacement based on a 3D beam trajectory analysis. As the result, the beam deflection was compensated and the voltage holding during the beam acceleration was improved. Beam parameter of the MeV accelerator was increased to 980 keV, 185 A∕m(2) (427 mA), which is close to the requirement of ITER accelerator (1 MeV, 200 A∕m(2)).

20.
Rev Sci Instrum ; 82(6): 063507, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21721691

ABSTRACT

A plasma generator for a long pulse H(+)/D(+) ion source has been developed. The plasma generator was designed to produce 65 A H(+)/D(+) beams at an energy of 120 keV from an ion extraction area of 12 cm in width and 45 cm in length. Configuration of the plasma generator is a multi-cusp bucket type with SmCo permanent magnets. Dimension of a plasma chamber is 25 cm in width, 59 cm in length, and 32.5 cm in depth. The plasma generator was designed and fabricated at Japan Atomic Energy Agency. Source plasma generation and beam extraction tests for hydrogen coupling with an accelerator of the KSTAR ion source have been performed at the KSTAR neutral beam test stand under the agreement of Japan-Korea collaborative experiment. Spatial uniformity of the source plasma at the extraction region was measured using Langmuir probes and ±7% of the deviation from an averaged ion saturation current density was obtained. A long pulse test of the plasma generation up to 200 s with an arc discharge power of 70 kW has been successfully demonstrated. The arc discharge power satisfies the requirement of the beam production for the KSTAR NBI. A 70 keV, 41 A, 5 s hydrogen ion beam has been extracted with a high arc efficiency of 0.9 -1.1 A/kW at a beam extraction experiment. A deuteron yield of 77% was measured even at a low beam current density of 73 mA/cm(2).

SELECTION OF CITATIONS