Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Antonie Van Leeuwenhoek ; 102(2): 361-74, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22562433

ABSTRACT

Despite the availability of many culture-based antibiotic screening methods, the lack of sensitive automated methods to identify functional molecules directly from microbial cells still limits the search for new biologically active compounds. The effectiveness of antibiotic detection is influenced by the solubility of the assayed compounds, indicator strain sensitivity, culture media and assay configuration. We describe a qualitative high throughput screening system for detecting cell-perturbing molecules from bacterial colonies employing two opposed agar layers sequentially formed in prototype Society for Biomolecular Screening (SBS) plates, named Janus plates. Direct assay of microbial colonies against target organisms in opposed agar layers overcomes some of the limitations of agar overlay methods. The system enables the rapid detection of extracellular cell-perturbing molecules, e.g., antibiotics, excreted directly from environmental isolates. The source bacterial colonies remain separate from the target organism. The growth layer is prepared and grown independently, so environmental strains can be grown for longer intervals, at temperatures and in media that favor their growth and metabolite expression, while the assay layer with pathogens, usually requiring nutrient-rich medium and elevated temperatures, are added later. Colonies to be tested can be precisely arrayed on the first agar surface, thus avoiding dispersion and disturbance of potential antibiotic-producing colonies by overlaying agar with the target strain. The rectangular SBS configuration facilitates factorial replication of dense microbial colony arrays for testing with multiple assays and assay conditions employing robotic colony pickers and pin tools. Opposed agar layers only slightly reduced the effectiveness for detecting growth inhibition from pure antibiotics compared to single-layer agar diffusion assays. The Janus plate enabled an automation-assisted workflow where a lone operator can effectively identify and accumulate bioactive soil bacterial strains within a few weeks. We also envisage the method's utility for functional prescreening colonies of clones from genomic and metagenomic libraries or improved strains originating from mutagenized cells.


Subject(s)
Anti-Bacterial Agents/metabolism , Bacteria/metabolism , Colony Count, Microbial/methods , Drug Evaluation, Preclinical/methods , High-Throughput Screening Assays/methods , Bacteria/growth & development , Colony Count, Microbial/instrumentation , Drug Evaluation, Preclinical/instrumentation , High-Throughput Screening Assays/instrumentation
2.
J Antimicrob Chemother ; 62(5): 1070-7, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18647747

ABSTRACT

OBJECTIVES: The aim of this study was to develop an integrated system for in vitro pharmacodynamic modelling of antimicrobials with greater flexibility, easier control and better accuracy than existing in vitro models. METHODS: Custom-made bottle caps, fittings, valve controllers and a modified bench-top shaking incubator were used. A temperature-controlled automated sample collector was built. Computer software was developed to manage experiments and to control the entire system including solenoid pinch valves, peristaltic pumps and the sample collector. The system was validated by pharmacokinetic simulations of linezolid 600 mg infusion. The antibacterial effect of linezolid against multiple Staphylococcus aureus strains was also studied in this system. RESULTS: An integrated semi-automated bench-top system was built and validated. The temperature-controlled automated sample collector allowed unattended collection and temporary storage of samples. The system software reduced the labour necessary for many tasks and also improved the timing accuracy for performing simultaneous actions in multiple parallel experiments. The system was able to simulate human pharmacokinetics of linezolid 600 mg intravenous infusion accurately. A pharmacodynamic study of linezolid against multiple S. aureus strains with a range of MICs showed that the required 24 h free drug AUC/MIC ratio was approximately 30 in order to keep the organism counts at the same level as their initial inoculum and was about > or = 68 in order to achieve > 2 log(10) cfu/mL reduction in the in vitro model. CONCLUSIONS: The integrated semi-automated bench-top system provided the ability to overcome many of the drawbacks of existing in vitro models. It can be used for various simple or complicated pharmacokinetic/pharmacodynamic studies efficiently and conveniently.


Subject(s)
Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/pharmacokinetics , Automation , Staphylococcus aureus/drug effects , Acetamides/pharmacokinetics , Acetamides/pharmacology , Colony Count, Microbial , Humans , In Vitro Techniques , Linezolid , Microbial Sensitivity Tests , Microbial Viability , Oxazolidinones/pharmacokinetics , Oxazolidinones/pharmacology , Time Factors
3.
Vaccine ; 26(40): 5202-9, 2008 Sep 19.
Article in English | MEDLINE | ID: mdl-18472195

ABSTRACT

Safe and efficient methods for in vivo delivery of transgenes of interest must be developed so that the promise of these therapies can be practically used in the clinic. In this work, we describe the use of electrostimulation to enhance the in vivo efficiency of plasmid DNA delivery. The method was optimized to work over a range of moderate frequencies, utilizing low field strengths and simple symmetrical waveforms. After studying several parameters of delivery in mice, we demonstrate how this methodology can be employed to significantly improve both gene expression (over 16-fold) and the immunogenicity of HIV-1 vaccines (over 28-fold) compared to naked DNA in non-human primates. Compared to an efficient viral Ad5 vector system, the gene expression levels of DNA+electrostimulation were surprisingly within a factor of four of the viral delivery system.


Subject(s)
AIDS Vaccines/immunology , Electroporation/methods , Genetic Vectors , Plasmids/genetics , Transgenes , Vaccines, DNA/immunology , AIDS Vaccines/genetics , Alkaline Phosphatase/genetics , Animals , Cell Line , Gene Expression , Gene Transfer Techniques , HIV Infections/immunology , HIV Infections/prevention & control , Humans , Macaca , Mice , Mice, Inbred BALB C , Vaccines, DNA/genetics
4.
J Biomol Screen ; 11(6): 704-11, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16844965

ABSTRACT

Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.


Subject(s)
Microbiological Techniques/instrumentation , Specimen Handling/instrumentation , Agar , Automation , Culture Media , Reference Standards
5.
J Am Assoc Lab Anim Sci ; 45(3): 45-50, 2006 May.
Article in English | MEDLINE | ID: mdl-16642970

ABSTRACT

We describe the basis of a new design for a user-friendly and easily reproduced mercury-displacement plethysmograph. This system was validated using the rat adjuvant-induced arthritis model in female Lewis rats. Furthermore, 2 different caging systems were evaluated to ensure that caging did not have an effect on disease progression and severity. These groups were evaluated further under frequent- and infrequent-handling conditions. Housing had less effect on the amount of swelling seen during the disease than did the amount of handling. Frequent handling significantly reduced the degree of paw swelling. Frequently handled, arthritic rats housed 5 rats per cage in the Box B system also lost a biologically significant amount of weight by the end of the study. Therefore, we do not recommend housing more than 4 rats per cage under these conditions.


Subject(s)
Arthritis, Experimental/chemically induced , Arthritis, Experimental/complications , Plethysmography/instrumentation , Stress, Physiological/complications , Stress, Physiological/diagnosis , Animals , Arthritis, Experimental/physiopathology , Disease Progression , Edema , Equipment Design , Female , Housing, Animal , Plethysmography/methods , Rats , Rats, Inbred Lew , Sensitivity and Specificity , Stress, Physiological/physiopathology , Time Factors
6.
Assay Drug Dev Technol ; 4(1): 21-35, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16506886

ABSTRACT

The Trans Cell Layer Electrical Field Stimulation (TCL-EFS) system has been developed for high-throughput screening (HTS) of voltage-gated ion channels in microplate format on a Voltage-Ion Probe Reader (VIPR) platform. In this design, a wire electrode is placed above the cell layer of each filter well, and a whole plate perimeter electrode resides beneath the filter layer. This configuration allows the electrodes to be placed away from the cell layer to minimize the near electrode field effects on cell function and dye bleaching observed with other existing designs. Mathematical simulation indicates that the electric field at the cell layer becomes uniform as the top electrode is raised to a position near the surface of the solution in the well. Using the TCL-EFS system and membrane potential fluorescence resonance energy transfer (FRET) dyes, the sensitivity of voltage-gated sodium channels to tetrodotoxin and other channel inhibitors was found to be similar to those determined by established electrophysiological and more conventional VIPR techniques. A good correlation was also observed with the TCL-EFS system for inhibition of Cav2.2 by omega-conotoxin-GVIA and for block of Cav1.2 by known small molecule inhibitors. Thus, the TCLEFS system is suitable for both quantitative analysis and HTS of voltage-gated sodium and calcium channels, without the liabilities of previously reported EFS methodologies.


Subject(s)
Ion Channel Gating/physiology , Membrane Potentials/physiology , Muscle Proteins/physiology , Sodium Channels/physiology , Calcium Channel Blockers/pharmacology , Cell Line , Computer Simulation , Electric Stimulation , Electrophysiology/instrumentation , Electrophysiology/methods , Humans , Kinetics , Muscle Proteins/drug effects , NAV1.5 Voltage-Gated Sodium Channel , Sodium Channels/drug effects , Tetrodotoxin/pharmacology , omega-Conotoxin GVIA/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL