Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
J Artif Organs ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38594483

ABSTRACT

Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient's individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient's symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 77-80), with some modifications.

2.
Article in English | MEDLINE | ID: mdl-38649641

ABSTRACT

BACKGROUND: Concomitant tricuspid valve (TV) repair is a safe and effective procedure to protect against late moderate or greater tricuspid regurgitation (TR) after left-sided valve surgery, but studies regarding its late outcomes and recurrent TR are limited. This study aimed to reveal the late outcomes and explore the predictors of mortality and recurrent TR among patients who underwent concomitant TV repair with left-sided valve surgery. METHODS AND RESULTS: This study included 645 patients (mean age, 69.7 years; 44% male) who underwent concomitant TV repair with left-sided valve surgery (mitral valve surgery in 594 cases, aortic valve surgery in 172 cases) from 2006-2020. Preoperative TR was grade 4, 3, and less than 2 in 85, 235, and 325 patients, respectively. The median follow-up period was 4.6 (IQR 1.7-7.8) years. The in-hospital or 30-day mortality was 1.7% (n = 11). Regarding long-term outcomes after TV repair, 90.3% and 80.8% achieved 5- and 10-year survival, respectively, while 96.1% and 88.8% achieved 5- and 10-year freedom from recurrent TR, respectively. The following were independent predictors of overall mortality on multivariate analysis in patients with preoperative TR grade ≥ 3: prior pacemaker implantation, preoperative renal dysfunction, diabetes mellitus and NYHA class ≥ 3. Also, suture annuloplasty and ring type of ring annuloplasty were not independent risk factors for recurrent TR, classified as grade ≥ 3. CONCLUSIONS: Concomitant TV repair with left-sided valve surgery had acceptable outcomes in terms of survival and TR durability. In patients with preoperative TR grade ≥ 3, preoperative patient status had negative impacts on prognosis.

3.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38616249

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Subject(s)
Aortic Valve Insufficiency , Heart Arrest , Transcatheter Aortic Valve Replacement , Female , Humans , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Device Removal
5.
J Artif Organs ; 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38190085

ABSTRACT

There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.

6.
Gen Thorac Cardiovasc Surg ; 72(5): 324-330, 2024 May.
Article in English | MEDLINE | ID: mdl-37709989

ABSTRACT

OBJECTIVES: Progression of aortic insufficiency during left-ventricular assist device (LVAD) support is a crucial topic. One treatment option is aortic valvuloplasty (AVP); however, there is controversy regarding its safety and efficacy. We investigated the safety and efficacy of AVP using the coaptation stitch method (Park's stitch) performed for de novo aortic insufficiency. METHODS: Between 2013 and 2020, 175 consecutive patients underwent LVAD implantation, of which 7 patients [men, 2 (28.6%); median age, 55 years] underwent late-stage AVP. Two patients underwent AVP within 2 weeks, and the remaining six patients underwent AVP 3, 19, 24, 28, 42, and 49 months, respectively, after LVAD implantation. RESULTS: Preoperatively, the degree of aortic insufficiency was moderate in 6 (85.7%) patients and severe in 1 (14.3%) patient. AVP was technically successful in 6 (85.7%) patients, while one case of failed plasty was subsequently treated with bioprosthetic valve replacement. A 1-year post-AVP right heart catheterization study revealed a median pulmonary artery wedge pressure of 10.0 mmHg. No deaths or heart failure admissions occurred during the follow-up (median, 38.0 months). There was no aortic insufficiency in 2 (28.6%) patients; however, trivial AI was observed in 3 (42.8%) patients, and mild AI was observed in 1 (14.3%) patient 2 years postoperatively. However, at the 3-year follow-up, two patients developed an increase in AI grade from trivial to mild. CONCLUSIONS: AVP using Park's stitch was safe. It is critical to carefully observe the aortic valve during AVP surgery to ensure that AVP is appropriate.


Subject(s)
Aortic Valve Insufficiency , Cardiac Surgical Procedures , Heart Failure , Heart-Assist Devices , Male , Humans , Middle Aged , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Failure/therapy , Treatment Outcome , Retrospective Studies
7.
JTCVS Open ; 15: 176-187, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808062

ABSTRACT

Objectives: Developments in both technique and technology have enabled surgeons to perform the maze procedure via right minithoracotomy (RMT) to treat atrial fibrillation (AF). This study aimed to clarify the outcomes of the modified cryomaze procedure via the RMT approach compared with the sternotomy approach. Methods: The study cohort comprised 803 consecutive patients who underwent a modified cryomaze procedure (130 via RMT and 673 via sternotomy) for paroxysmal AF and persistent AF from January 2001 to March 2022. The Gray test was applied to compare the incidence of recurrent atrial tachyarrhythmias. Additionally, residual electrical gaps were investigated in the patients who underwent additional catheter ablation for recurrent atrial tachyarrhythmias. Results: The respective 1-, 2-, and 3-year cumulative incidences of recurrent atrial tachyarrhythmias were 13.1%, 19.5%, and 23.1% in the RMT group, and 9.3%, 10.9%, and 12.8% in the sternotomy group (Gray test P = .036). All 31 patients with recurrent atrial tachyarrhythmias underwent additional catheter ablation, comprising 14 (10.8%) in the RMT group and 17 (2.5%) in the sternotomy group. There was a significant intergroup difference in the site of residual electrical gaps; the RMT group more frequently had residual gaps in the tricuspid annulus than the sternotomy group (6.2% vs 0.4%; P < .001). Conclusions: In the modified cryomaze procedure via the RMT approach, ablation failure is more likely to occur at the tricuspid annulus, where the surgical field of view is relatively poor compared with the sternotomy approach. Therefore, surgical ablation should be performed with caution when the RMT approach is used.

8.
Gen Thorac Cardiovasc Surg ; 71(12): 692-699, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37418064

ABSTRACT

BACKGROUND: Despite the growing popularity of robotically assisted mitral repair, robotically assisted tricuspid repair has not been widely adopted. We assessed the safety and feasibility of robotic tricuspid annuloplasty with continuous sutures for tricuspid regurgitation (TR). METHODS AND RESULTS: We studied consecutive 68 patients (median age, 74 years) with secondary TR who underwent tricuspid annuloplasty using continuous sutures with (n = 61) and without mitral valve repair (n = 7) from 2018 to 2021. Robotic tricuspid annuloplasty consists of continuous sutures with flexible prosthetic band to the tricuspid annulus using two V-Loc barbed sutures (Medtronic Inc., Minneapolis, MN). Concomitant maze procedure was performed in 45 (66%) patients. Robotic tricuspid annuloplasty with continuous sutures was successfully performed. There was no in-hospital or 30-day mortality; 65 patients (96%) did not experience major surgery-related complications. Preoperatively, the TR grade was mild in 20 (29%) patients and mildly higher in 48 (71%). Postoperatively, the TR severity significantly improved, with TR grade mildly higher in 9% at hospital discharge and 7% at 1-year follow-up (p < 0.001). The 1-year and 2-year freedom rates from heart failure were 98% and 95%, respectively. CONCLUSIONS: Robotic tricuspid annuloplasty with continuous sutures is safe and feasible alone or concomitant with mitral valve repair. It offered sustained improvement in TR severity and might prevent heart failure readmission.


Subject(s)
Heart Failure , Robotic Surgical Procedures , Tricuspid Valve Insufficiency , Humans , Aged , Tricuspid Valve Insufficiency/surgery , Mitral Valve/surgery , Robotic Surgical Procedures/adverse effects , Hospitals
9.
J Am Heart Assoc ; 12(11): e028607, 2023 06 06.
Article in English | MEDLINE | ID: mdl-37232245

ABSTRACT

Background This study assessed risk factors for mitral regurgitation (MR) recurrence or functional mitral stenosis during long-term follow-up in patients undergoing mitral valve repair for isolated posterior mitral leaflet prolapse. Methods and Results We assessed a consecutive series of 511 patients who underwent primary mitral valve repair for isolated posterior leaflet prolapse between 2001 and 2021. Annuloplasty using a partial band was selected in 86.3%. The leaflet resection technique was used in 83.0%, whereas the chordal replacement without resection was used in 14.5%. Risk factors were analyzed for MR recurrence ≥grade 2 or functional mitral stenosis with mean transmitral pressure gradient ≥5 mm Hg using a multivariable Fine-Gray regression model. The 1-, 5-, and 10-year cumulative incidence of MR ≥grade 2 was 7.8%, 22.7%, and 30.1%, respectively, whereas that of mean transmitral pressure gradient ≥5 mm Hg was 8.1%, 20.6%, and 29.3%, respectively. Risk factors for MR ≥grade 2 included chordal replacement without resection (hazard ratio [HR], 2.50, P<0.001) and larger prosthesis size (HR, 1.13, P=0.023), whereas factors for functional mitral stenosis were use of a full ring (partial band versus full ring, HR, 0.53, P=0.013), smaller prosthesis size (HR, 0.74, P<0.001), and larger body surface area (HR, 3.03, P=0.045). Both MR ≥grade 2 and mean transmitral pressure gradient ≥5 mm Hg at 1 year post surgery were significantly associated with the long-term incidence of reoperation. Conclusions Leaflet resection with a large partial band may be an optimal strategy for isolated posterior mitral valve prolapse.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve Prolapse , Mitral Valve Stenosis , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Stenosis/complications , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Mitral Valve Prolapse/complications , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Prolapse
10.
J Thorac Dis ; 15(3): 994-1008, 2023 Mar 31.
Article in English | MEDLINE | ID: mdl-37065581

ABSTRACT

Background: Although a bicuspid aortic valve (BAV) is known to be associated with progressive ascending aortic dilatation, the fate of the residual aorta after aortic valve and ascending aorta surgery is unknown. We reviewed surgical outcomes and explored serial changes in the size of the sinus of Valsalva (SOV) and distal ascending aorta (DAAo) in 89 patients with a BAV undergoing aortic valve replacement (AVR) and graft replacement (GR) of the ascending aorta. Methods: We retrospectively examined patients who underwent AVR and GR of the ascending aorta for BAV-and related disease and thoracic aortic dilatation at our institution between January 2009 and December 2018. Patients who underwent AVR alone or required intervention for the aortic root and aortic arch and patients with connective tissue diseases were excluded. Aortic diameters were examined using computed tomography (CT). Late CT more than 1 year after surgery was performed in 69 patients (78%) with a mean follow-up of 4.9±2.8 years. Results: The surgical indication for aortic valve etiology was stenosis in 61 patients (69%), regurgitation in 10 (11%), and mixed in 18 (20%). Preoperative maximum short diameters of the ascending aorta, SOV, and DAAo were 47.3±4.7, 36.0±5.2, and 37.2±3.6 mm, respectively. The diameter of the SOV increased non-significantly by 0.08±0.45 mm per year [95% confidence interval (CI): -0.12 to 0.11, P=0.150], while that of the DAAo increased significantly by 0.11±0.40 mm per year (95% CI: 0.02-0.21, P=0.005). One patient required reoperation 6 years postoperatively due to a pseudo-aneurysm at the proximal anastomotic site. No patient required reoperation due to progressive dilatation of the residual aorta. According to the Kaplan-Meier analysis, the long-term survival rates were 98.9%, 98.9%, and 92.7% at 1, 5, and 10 years postoperatively, respectively. Conclusions: Rapid dilatation of the residual aorta rarely occurred in patients with a BAV who underwent AVR and GR of the ascending aorta in the mid-term follow-up. For selected patients with a surgical indication for ascending aortic dilatation, simple AVR and GR of the ascending aorta may be sufficient surgical options.

12.
J Artif Organs ; 26(2): 151-155, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35906510

ABSTRACT

Implantation of left ventricular assist device (LVAD) for arrhythmogenic right ventricular (RV) cardiomyopathy is challenging associated with small LV cavity, laterally dislocated LV apex, thin and fragile RV free wall. A 43-year-old male with more than 10 years of medical treatment developed congestive heart failure related to biventricular failure. Durable LVAD was indicated to prevent further deterioration of the RV function, which would be exacerbated by progression of LV dysfunction. To simulate surgery, we printed-out a 3D heart model based on enhanced CT scanning study to identify the optimal coring position in the LV apex, by which the inflow directs the mitral valve. We then found that the mini-cuff of the HeartMate3 should be fixed in the paper-thin RV free wall by the usual cuff-sewing method. In the surgery, after the coring as planned, 5 pairs of interrupted sutures on the medial side were passed from the luminal side of the LV and then to the mini-cuff, and the lateral side of the mini-cuff was fixed with a continuous sutures, not to sew into the RV wall. The surgery was completed without complications with a good hemodynamics. The 3D heart model facilitated this unique method, indicating a usefulness of printed-out heart model for cases with unusual cardiac anatomy, which needs implantation of durable LVAD.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Left , Ventricular Dysfunction, Right , Male , Humans , Adult , Arrhythmogenic Right Ventricular Dysplasia/surgery , Arrhythmogenic Right Ventricular Dysplasia/complications , Heart-Assist Devices/adverse effects , Heart Failure/surgery , Ventricular Dysfunction, Left/complications , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right
13.
Gen Thorac Cardiovasc Surg ; 71(3): 151-157, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35953640

ABSTRACT

OBJECTIVE: The Japanese Off-Pump Coronary Revascularization Investigation (JOCRI) study reported a non-significant difference in early outcomes and graft patency between off-pump coronary artery bypass grafting and on-pump coronary artery bypass grafting in 2005. The JOCRIED study aimed to review the long-term outcomes of the JOCRI study participants. METHOD AND RESULTS: The JOCRIED study enrolled 123 of the JOCRI study participants completing the clinical follow-up between August 2018 and August 2020; 61 patients in the off-pump group and 62 patients in the on-pump group. The follow-up period was 13.8 ± 2.8 years. The groups were compared regarding mortality, the incidence of major adverse cardiac and cerebrovascular events and repeat revascularisation. The 15-year cumulative survival rate (off-pump vs on-pump, respectively; 77.7% vs 75.3%; p = 0.85), major adverse events-free survival rate (62.5% vs 55.6%; p = 0.27) and repeat revascularisation-free rate (84.8% vs 78.0%; p = 0.16) were not significantly different between the two groups. Revascularisation was the most common major adverse events in the JOCRIED participants. Although percutaneous coronary intervention was performed in 8 patients (13%) in the off-pump group and in 14 patients (23%) in the on-pump group (p = 0.23), no patients underwent redo coronary artery bypass grafting. CONCLUSIONS: Off-pump coronary artery bypass grafting provides comparable 15-year outcomes to on-pump coronary artery bypass grafting.


Subject(s)
Coronary Artery Bypass, Off-Pump , Coronary Artery Disease , Humans , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/methods , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Follow-Up Studies , Treatment Outcome
14.
J Thorac Cardiovasc Surg ; 166(2): 519-529.e4, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35012781

ABSTRACT

OBJECTIVE: This study aimed to elucidate whether the use of bilateral internal thoracic arteries (BITAs) confers additional survival benefits compared with a single internal thoracic artery (SITA) in total arterial grafting with the radial artery. METHODS: Between 2002 and 2016, 617 patients underwent a bilateral in situ internal thoracic artery grafting with the radial artery as a composite I-graft (BITA-I group) and 516 patients underwent single in situ internal thoracic artery grafting with the radial artery as a composite Y-graft (SITA-Y group). All anastomoses were performed without cardiopulmonary bypass and aortic manipulation. Propensity score matching was performed to adjust covariates and compared the outcomes between the 2 groups. Subanalysis was also performed to evaluate the effects of the BITA-I group on survival according to the covariates using Cox proportional hazards regression analysis. RESULTS: Propensity score matching yielded 348 well-matched pairs. Early postoperative outcomes were similar in the 2 groups. The BITA-I group showed significantly better survival than the SITA-Y group (79.3% vs 70.2% at 10 years, P = .015). The subanalysis revealed a significantly better survival in the BITA-I group among overall patients (hazard ratio, 0.68; 95% confidence interval, 0.49-0.93). There was a significant positive effect on survival in the BITA-I group among patients without comorbidities or those aged <77 years. CONCLUSIONS: BITA grafting with the radial artery provides better long-term survival than SITA grafting with the radial artery, which is enhanced among patients aged <77 years with minimum comorbidities.


Subject(s)
Coronary Artery Disease , Mammary Arteries , Humans , Mammary Arteries/transplantation , Radial Artery/transplantation , Treatment Outcome , Retrospective Studies , Coronary Artery Bypass/adverse effects , Internal Mammary-Coronary Artery Anastomosis/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Artery Disease/etiology
15.
J Thorac Cardiovasc Surg ; 166(3): 755-766.e1, 2023 09.
Article in English | MEDLINE | ID: mdl-35027213

ABSTRACT

OBJECTIVES: The Maze procedure is a well-established treatment for atrial fibrillation. However, it is sometimes associated with bradycardia requiring pacemaker implantation. We assessed the rates of in-hospital and late-onset pacemaker implantation after the modified Cryo-Maze procedure and explored the risk factors for pacemaker implantation. METHODS: This study enrolled a series of 751 patients who underwent the modified Cryo-Maze procedure at our institution between 2001 and 2020. Multivariable Fine-Gray regression was used to analyze the risk factors for late-onset pacemaker implantation. RESULTS: Twelve patients (1.6%) underwent in-hospital pacemaker implantation, and 55 patients (7.3%) underwent late-onset pacemaker implantation during a median follow-up of 4.5 years (interquartile range, 1.4-10.0). The most common primary indication for pacemaker implantation was sick sinus syndrome (56 patients [7.5%]), followed by complete atrioventricular block (11 patients [1.5%]). The cumulative incidence of late-onset pacemaker implantation with death as a competing risk was 2.8% at 1 year, 7.7% at 5 years, and 10.8% at 10 years. Risk factors for late-onset pacemaker implantation included a longer preoperative atrial fibrillation duration (hazard ratio, 1.14; P < .001) and an older age (hazard ratio, 1.05; P = .001). The mortality, cumulative incidence of cerebrovascular accidents, and rate of atrial fibrillation recurrence were not significantly different between patients with and without pacemaker implantation. CONCLUSIONS: Longer preoperative atrial fibrillation duration and older age are risk factors for late-onset pacemaker implantation after the modified Cryo-Maze procedure. However, the incidence of pacemaker implantation is not associated with increased morbidity or atrial fibrillation recurrence.


Subject(s)
Atrial Fibrillation , Maze Procedure , Pacemaker, Artificial , Atrial Fibrillation/surgery , Incidence , Sick Sinus Syndrome/surgery , Risk Factors , Humans , Male , Female , Middle Aged , Aged , Treatment Outcome , Cohort Studies
16.
Circ J ; 86(12): 1961-1967, 2022 11 25.
Article in English | MEDLINE | ID: mdl-36273915

ABSTRACT

BACKGROUND: The superiority of a fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) in terms of overall survival, stroke events and pump thrombosis has been demonstrated in previous international analyses, so we evaluated a Japanese cohort for the same.Methods and Results: This retrospective observational study was conducted at Osaka University Medical Hospital and the National Cerebral and Cardiovascular Center in Japan. A total of 75 consecutive patients who underwent HeartMate3 (HM3) implantation were included. The primary endpoint was on-device survival, and the secondary endpoint was the incidence of LVAD-related complications at 2 years. All parameters were compared with those of the previously performed HeartMate II (HMII) implantation in 197 cases. The on-device survival rates were 94.7% and 92.3% in the HM3 and HMII groups, respectively, at the 2-year follow-up (P=0.62). The rehospitalization-free rate after implantation was 61.8% in the HM3 group, which was significantly higher than that in the HMII group (relative risk, 0.35; 95% confidence interval [CI], 0.23-0.55; P<0.0001). Event-free survival rates from cerebral cerebrovascular events and pump thrombosis in the HM3 group were significantly higher than those in the HMII group, at 97.2% and 100%, respectively (relative risk, 0.14; 95% CI 0.03-0.58); P=0.0015 and relative risk, not calculated; P=0.049, respectively). CONCLUSIONS: Satisfactory short-term outcomes were observed after HM3 implantation in a Japanese cohort.


Subject(s)
Heart Failure , Heart-Assist Devices , Stroke , Thrombosis , Humans , Heart-Assist Devices/adverse effects , Japan/epidemiology , Stroke/complications , Thrombosis/etiology , Retrospective Studies , Treatment Outcome
17.
Heart Lung Circ ; 31(12): 1666-1676, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36150952

ABSTRACT

AIM: This study aimed to evaluate the early and intermediate-term outcomes of patients who underwent concomitant off-pump coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR). METHOD: Between January 2014 and June 2021, 49 patients underwent concomitant off-pump CABG and TAVR via median sternotomy (TAVRCAB group) and 143 underwent concomitant on-pump CABG and surgical aortic replacement. Of the 143 patients who underwent on-pump surgery, 80 (SAVRCAB group) were eligible for comparison. The composite event included all-cause death, heart failure rehospitalisation, repeat revascularisation, brain infarction, and repeat aortic valve replacement. RESULTS: The Society of Thoracic Surgeons' predicted risk for mortality and age were higher in the TAVRCAB group than in the SAVRCAB group (7.1% vs 3.1% [p<0.001]; 81 yrs vs 75 years [p<0.001], respectively), while the surgical time was shorter (289 min vs 352 min; p<0.001). There was no conversion to on-pump surgery in the TAVRCAB group. The postoperative maximum creatinine kinase-MB value was lower in the TAVRCAB group. There was no deep sternal wound infection or repeat revascularisation in either group. Hospital death and brain infarction developed in one patient (1.3%) each in the SAVRCAB group, but in no patients in the TAVRCAB group. The rates of freedom from the composite event were similar between the two groups during the follow-up period. CONCLUSIONS: Concomitant off-pump CABG and TAVR would be a less-invasive alternative procedure for treating intermediate or high surgical risk patients with aortic stenosis and coronary artery disease unsuitable for percutaneous coronary intervention.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Bypass, Off-Pump , Coronary Artery Disease , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve/surgery , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass/methods , Coronary Artery Disease/complications , Coronary Artery Disease/surgery
19.
Circ J ; 86(11): 1710-1718, 2022 10 25.
Article in English | MEDLINE | ID: mdl-35569971

ABSTRACT

BACKGROUND: This study aimed to elucidate the short-term surgical outcomes and hemodynamics of the Intuity valve compared to the standard bioprosthesis in Japanese patients.Methods and Results: Among the 307 consecutive patients who underwent aortic valve replacement (AVR) between February 2019 and March 2021, the Intuity valve was implanted in 95 patients (Intuity group) and a conventional stented bioprosthesis was implanted in 193 patients (conventional group). After propensity score matching, there was no significant difference in in-hospital mortality between the Intuity (n=2, 3%) and conventional groups (n=0, P=0.490). Operation, cardiopulmonary bypass, and aortic cross-clamping times were significantly shorter in the Intuity group. Although the effective orifice area index, trans-prosthetic mean pressure gradient, and peak velocity were similar between the 2 groups at 1 week postoperatively, the Intuity group showed a better mean pressure gradient and peak velocity at 1 year postoperatively. Complete atrioventricular block requiring permanent pacemaker implantation developed in 2 patients (3%) in the Intuity group and none in the conventional group (P=0.476). Mild or greater paravalvular leakage was present in 8 patients (13%) in the Intuity group and 2 patients (3%) in the conventional group (P=0.095). CONCLUSIONS: AVR using the Intuity valve in Japanese patients is satisfactory, with a better valve performance and a low incidence of complete atrioventricular block at 1 year postoperatively.


Subject(s)
Aortic Valve Stenosis , Atrioventricular Block , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aortic Valve/surgery , Japan , Prosthesis Design , Treatment Outcome
20.
Gen Thorac Cardiovasc Surg ; 70(9): 761-769, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35239104

ABSTRACT

OBJECTIVES: This study aimed to elucidate the mid-term outcomes and risk factors for recurrent mitral regurgitation after mitral valve (MV) surgery for atrial functional mitral regurgitation (AFMR). METHODS AND RESULTS: We retrospectively analyzed data of 50 consecutive patients (median age 74 years; 29 men) who underwent mitral valve surgery for AFMR between January 2001 and January 2019. Mean atrial fibrillation duration was 12 years. During the follow-up period of 4.6 ± 4.4 years, 5 cardiac-related deaths were identified. Five- and 10-year freedom from cardiac-related death rate for all patients was 88.4% and 78.6%. In total, 42 patients underwent MV repair with mitral annuloplasty and 8 underwent MV replacement. Five- and 10-year freedom from cardiac-related death rate in patients who underwent MV repair was 93.1% and 82.7%, which was better than MV replacement (log rank p = 0.04). During the follow-up period, MR recurrence rate was 16.8% at 5 and 10 years for the patients who underwent MV repair. Univariate analysis showed that partial band annuloplasty and preoperative elevated left ventricular end-systolic volume index were risk factors for recurrent MR after MV repair. Multivariate analysis identified partial band annuloplasty as the independent predictor for recurrent MR during long-term follow-up after MV repair for AFMR. CONCLUSION: Patients who underwent MV repair for AFMR could have an acceptable mid-term outcome. However, MVR might not improve the mid-term outcome in patients with AFMR. The use of partial bands for mitral annuloplasty would not be recommended in terms of recurrent MR mid-term.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Aged , Follow-Up Studies , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Annuloplasty/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...