Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Trends Microbiol ; 29(2): 92-97, 2021 02.
Article in English | MEDLINE | ID: mdl-33288385

ABSTRACT

Despite the international guidelines on the containment of the coronavirus disease 2019 (COVID-19) pandemic, the European scientific community was not sufficiently prepared to coordinate scientific efforts. To improve preparedness for future pandemics, we have initiated a network of nine European-funded Cooperation in Science and Technology (COST) Actions that can help facilitate inter-, multi-, and trans-disciplinary communication and collaboration.


Subject(s)
Biomedical Research/organization & administration , COVID-19/virology , SARS-CoV-2/physiology , Communication , Europe , Humans , Laboratory Personnel , Pandemics , SARS-CoV-2/genetics
2.
Water Res X ; 9: 100069, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-33083777

ABSTRACT

Nitrite in drinking water is a potentially harmful substance for humans, and controlling nitrite formation in drinking water distribution systems (DWDSs) is highly important. The effect of natural organic matter (NOM) on the formation of nitrite in simulated distribution systems was studied. The objective was to inspect how a reduced NOM concentration affected nitrite development via nitrification, separated from the effects of disinfection. We observed that nitrite formation was noticeably sensitive to the changes in the NOM concentrations. Nitrite declined with reduced NOM (TOC 1.0 mg L-1) but increased with the normal NOM concentration of tap water (TOC 1.6 mg L-1). Ammonium oxidation was not altered by the reduced NOM, however, nitrite oxidation was enhanced significantly according to the pseudo-first order reaction rate model interpretation. The enhanced nitrite oxidation was observed with both ammonium and nitrite as the initial nitrogen source. The theoretical maximum nitrite concentrations were higher with the normal concentration of NOM than with reduced NOM. The results suggest that the role of nitrite oxidation may be quite important in nitrite formation in DWDSs and worth further studies. As a practical result, our study supported enhanced NOM removal in non-disinfected DWDSs.

3.
Article in English | MEDLINE | ID: mdl-30111761

ABSTRACT

We studied the seasonal variation of nitrite exposure in a drinking water distribution system (DWDS) with monochloramine disinfection in the Helsinki Metropolitan Area. In Finland, tap water is the main source of drinking water, and thus the nitrite in tap water increases nitrite exposure. Our data included both the obligatory monitoring and a sampling campaign data from a sampling campaign. Seasonality was evaluated by comparing a nitrite time series to temperature and by calculating the seasonal indices of the nitrite time series. The main drivers of nitrite seasonality were the temperature and the water age. We observed that with low water ages (median: 6.7 h) the highest nitrite exposure occurred during the summer months, and with higher water ages (median: 31 h) during the winter months. With the highest water age (190 h), nitrite concentrations were the lowest. At a low temperature, the high nitrite concentrations in the winter were caused by the decelerated ammonium oxidation. The dominant reaction at low water ages was ammonium oxidation into nitrite and, at high water ages, it was nitrite oxidation into nitrate. These results help to direct monitoring appropriately to gain exact knowledge of nitrite exposure. Also, possible future process changes and additional disinfection measures can be designed appropriately to minimize extra nitrite exposure.


Subject(s)
Drinking Water/analysis , Nitrites/analysis , Water Pollutants, Chemical/analysis , Ammonium Compounds/chemistry , Chloramines/chemistry , Disinfection/methods , Environmental Monitoring , Finland , Nitrates/chemistry , Nitrites/chemistry , Oxidation-Reduction , Seasons , Temperature , Water Pollutants, Chemical/chemistry
4.
Article in English | MEDLINE | ID: mdl-28362344

ABSTRACT

Infections and infectious diseases are considered a major challenge to human health in healthcare units worldwide. This opinion paper was initiated by EU COST Action network AMiCI (AntiMicrobial Coating Innovations) and focuses on scientific information essential for weighing the risks and benefits of antimicrobial surfaces in healthcare settings. Particular attention is drawn on nanomaterial-based antimicrobial surfaces in frequently-touched areas in healthcare settings and the potential of these nano-enabled coatings to induce (eco)toxicological hazard and antimicrobial resistance. Possibilities to minimize those risks e.g., at the level of safe-by-design are demonstrated.


Subject(s)
Anti-Infective Agents/therapeutic use , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Fomites/microbiology , Infection Control/methods , Nanostructures , Drug Resistance, Microbial , Humans , Infection Control/standards , Quality of Health Care , Safety
5.
Bioengineered ; 8(6): 679-685, 2017 Nov 02.
Article in English | MEDLINE | ID: mdl-28453429

ABSTRACT

Worldwide, millions of patients are affected annually by healthcare-associated infection (HCAI), impacting up to 80,000 patients in European Hospitals on any given day. This represents not only public health risk, but also an economic burden. Complementing routine hand hygiene practices, cleaning and disinfection, antimicrobial coatings hold promise based, in essence, on the application of materials and chemicals with persistent bactericidal or -static properties onto surfaces or in textiles used in healthcare environments. The focus of considerable commercial investment and academic research energies, such antimicrobial coating-based approaches are widely believed to have potential in reduction of microbial numbers on surfaces in clinical settings. This belief exists despite definitive evidence as to their efficacy and is based somewhat on positive studies involving, for example, copper, silver or gold ions, titanium or organosilane, albeit under laboratory conditions. The literature describes successful delay and/or prevention of recontamination following conventional cleaning and disinfection by problematic microbes such as methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin resistant enterococci (VRE), among others. However, there is a scarcity of studies assessing antimicrobial surfaces other than copper in the clinical environment, and a complete lack of published data regarding the successful implementation of these materials on clinically significant outcomes (including HCAI). Through its Cooperation in Science and Technology program (COST), the European Commission has funded a 4-year initiative to establish a network of stakeholders involved in development, regulation and use of novel anti-microbial coatings for prevention of HCAI. The network (AMiCI) comprises participants of more than 60 universities, research institutes and companies across 29 European countries and, to-date, represents the most comprehensive consortium targeting use of these emergent technologies in healthcare settings. More specifically, the network will prioritise coordinated research on the effects (both positive and negative) of antimicrobial coatings in healthcare sectors; know-how regarding availability and mechanisms of action of (nano)-coatings; possible adverse effects of such materials (e.g., potential emergence of microbial resistance or emission of toxic agents into the environment); standardised performance assessments for antimicrobial coatings; identification and dissemination of best practices by hospitals, other clinical facilities, regulators and manufacturers.


Subject(s)
Cross Infection/prevention & control , Anti-Infective Agents/chemistry , Anti-Infective Agents/therapeutic use , Humans , Methicillin-Resistant Staphylococcus aureus/drug effects , Vancomycin-Resistant Enterococci/drug effects
6.
Water Res ; 49: 83-91, 2014 Feb 01.
Article in English | MEDLINE | ID: mdl-24317021

ABSTRACT

Complex interactions existing between water distribution systems' materials and water can cause a reduction in water quality and unwanted changes in materials, aging or corrosion of materials and formation of biofilms on surfaces. Substances leaching from pipe materials and water fittings, as well as the microbiological quality of water and formation of biofilms were evaluated by applying a Living Lab theme i.e. a research in a real life setting using a full scale system during its first year of operation. The study site was a real office building with one part of the building lined with copper pipes, the other with cross-linked polyethylene (PEX) pipes thus enabling material comparison; also differences within the cold and hot water systems were analysed. It was found that operational conditions, such as flow conditions and temperature affected the amounts of metals leaching from the pipe network. In particular, brass components were considered to be a source of leaching; e. g. the lead concentration was highest during the first few weeks after the commissioning of the pipe network when the water was allowed to stagnate. Assimilable organic carbon (AOC) and microbially available phosphorus (MAP) were found to leach from PEX pipelines with minor effects on biomass of the biofilm. Cultivable and viable biomass (heterotrophic plate count (HPC), and adenosine triphosphate (ATP)) levels in biofilms were higher in the cold than in the hot water system whereas total microbial biomass (total cell count (DAPI)) was similar with both systems. The type of pipeline material was not found to greatly affect the microbial biomass or Alpha-, Beta- and Gammaproteobacteria profiles (16s rRNA gene copies) after the first one year of operation. Also microbiological quality of water was found to deteriorate due to stagnation.


Subject(s)
Biofilms/growth & development , Drinking Water/standards , Facility Design and Construction , Water Quality/standards , Copper/chemistry , Drinking Water/microbiology , Lead/analysis , Molybdenum/analysis , Sanitary Engineering , Temperature , Water Microbiology , Water Pollutants, Chemical/analysis , Zinc/analysis , Zinc/chemistry
7.
Can J Microbiol ; 59(6): 407-12, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23750955

ABSTRACT

Electronic faucets (types E1 and E2) and manual (M) faucets were studied for microbial quality, i.e., biomass and pathogenic microbes of biofilms in the faucet aerator, the water, and the outer surface of faucet in a hospital in Finland. Heterotrophic plate count content reflecting culturable microbial biomass and adenosine triphosphate content representing viable microbial biomass were smaller in the biofilms of E1-type electronic faucets than E2-type electronic faucets or M faucets. The likely explanation is the mixing point of cold and hot water (E1 and M: in the faucet; E2: in a separate box 50 cm before the actual faucet part). The highest amounts of Legionella (serogroups 2-15 of Legionella pneumophila) in a water sample (5000 cfu/L) and in biofilm samples (May-June 2008 sampling: 240 cfu/mL; November 2008: 1100 cfu/mL) were found in one E1-type faucet, which was lacking a back pressure valve due to faulty installation. This study reveals that certain types of electronic faucets seem to promote hospital hygiene, as they were associated with less microbial growth in biofilms in the faucet aerator, than some other types of electronic faucets or manual faucets, likely owing to the mixing point of cold and hot water. However, the faucet type had no direct effect on the presence of Legionella spp. Also correct installation is crucial.


Subject(s)
Bacteria/growth & development , Biofilms/growth & development , Drinking Water/microbiology , Equipment Contamination , Legionella/growth & development , Bacterial Load , Biomass , Electronics , Finland , Hospitals, University , Legionella pneumophila/growth & development , Sanitary Engineering , Water Microbiology
8.
FEMS Microbiol Lett ; 257(2): 182-8, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16553851

ABSTRACT

Recent phylogenetic studies have used DNA as the target molecule for the development of environmental 16S rRNA gene clone libraries. As DNA may persist in the environment, DNA-based libraries cannot be used to identify metabolically active bacteria in water systems. In this study, an annular reactor was used to generate model drinking water biofilms grown on polycarbonate slides. High-quality RNA was extracted from 2-month-old biofilms and used to generate 16S rRNA-based clones. Sequencing analyses of 16S rRNA-based clones suggested that the active bacterial fraction consisted of a few dominant bacterial groups related to Nevskia ramosa and to uncultured bacteria. Several of these bacterial groups were closely related to clones characterized in a DNA-based clone library also generated in this study. Altogether, these results suggest that some of the predominant drinking water bacteria identified using DNA-based techniques are indeed active.


Subject(s)
Bacteria/isolation & purification , Bacterial Physiological Phenomena , Biofilms/growth & development , Environmental Monitoring/methods , Water Microbiology , Water Supply/analysis , Bacteria/classification , Bacteria/genetics , DNA, Bacterial/genetics , Gene Library , Molecular Sequence Data , Polycarboxylate Cement , Polymerase Chain Reaction , RNA, Bacterial/genetics , RNA, Ribosomal, 16S/genetics , Species Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...