Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Radiother Oncol ; 151: 88-94, 2020 10.
Article in English | MEDLINE | ID: mdl-32622779

ABSTRACT

PURPOSE: To evaluate prostate intrafraction motion using MRI during the full course of online adaptive MR-Linac radiotherapy (RT) fractions, in preparation of MR-guided extremely hypofractionated RT. MATERIAL AND METHODS: Five low and intermediate risk prostate cancer patients were treated with 20 × 3.1 Gy fractions on a 1.5T MR-Linac. Each fraction, initial MRI (Pre) scans were obtained at the start of every treatment session. Pre-treatment planning MRI contours were propagated and adapted to this Pre scan after which plan re-optimization was started in the treatment planning system followed by dose delivery. 3D Cine-MR imaging was started simultaneously with beam-on and acquired over the full beam-on period. Prostate intrafraction motion in this cine-MR was determined with a previously validated soft-tissue contrast based tracking algorithm. In addition, absolute accuracy of the method was determined using a 4D phantom. RESULTS: Prostate motion was completely automatically determined over the full on-couch period (approx. 45 min) with no identified mis-registrations. The translation 95% confidence intervals are within clinically applied margins of 5 mm, and plan adaption for intrafraction motion was required in only 4 out of 100 fractions. CONCLUSION: This is the first study to investigate prostate intrafraction motions during entire MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and prostate tracking during RT is feasible with beam-on. The clinically applied margins of 5 mm have proven to be sufficient for these treatments and may potentially be further reduced using intrafraction plan adaptation guided by cine-MR imaging.


Subject(s)
Prostatic Neoplasms , Radiotherapy Planning, Computer-Assisted , Humans , Magnetic Resonance Imaging , Male , Movement , Particle Accelerators , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy
2.
Phys Med Biol ; 65(2): 025012, 2020 01 17.
Article in English | MEDLINE | ID: mdl-31842008

ABSTRACT

To investigate the dosimetric impact of intrafraction translation and rotation motion of the prostate, as extracted from daily acquired post-treatment 3D cine-MR based on soft-tissue contrast, in extremely hypofractionated (SBRT) prostate patients. Accurate dose reconstruction is performed by using a prostate intrafraction motion trace which is obtained with a soft-tissue based rigid registration method on 3D cine-MR dynamics with a temporal resolution of 11 s. The recorded motion of each time-point was applied to the planning CT, resulting in the respective dynamic volume used for dose calculation. For each treatment fraction, the treatment delivery record was generated by proportionally splitting the plan into 11 s intervals based on the delivered monitor units. For each fraction the doses of all partial plan/dynamic volume combinations were calculated and were summed to lead to the motion-affected fraction dose. Finally, for each patient the five fraction doses were summed, yielding the total treatment dose. Both daily and total doses were compared to the original reference dose of the respective patient to assess the impact of the intrafraction motion. Depending on the underlying motion of the prostate, different types of motion-affected dose distributions were observed. The planning target volumes (PTVs) ensured CTV_30 (seminal vesicles) D99% coverage for all patients, CTV_35 (prostate corpus) coverage for 97% of the patients and GTV_50 (local boost) for 83% of the patients when compared against the strict planning target D99% value. The dosimetric impact due to prostate intrafraction motion in extremely hypofractionated treatments was determined. The presented study is an essential step towards establishing the actual delivered dose to the patient during radiotherapy fractions.


Subject(s)
Dose Fractionation, Radiation , Imaging, Three-Dimensional , Movement , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Algorithms , Humans , Male , Radiometry , Radiotherapy Planning, Computer-Assisted , Rotation
3.
Phys Med Biol ; 64(23): 235008, 2019 12 05.
Article in English | MEDLINE | ID: mdl-31698351

ABSTRACT

To develop a method to automatically determine intrafraction motion of the prostate based on soft tissue contrast on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients who underwent prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold fiducial markers (FMs), had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR session consisted of 55 sequentially obtained 3D data sets ('dynamics') and was acquired over an 11 s period, covering a total of 10 min. The prostate was delineated on the first dynamic of every dataset and this delineation was used as the starting position for the soft tissue tracking (SST). Each subsequent dynamic was rigidly aligned to the first dynamic, based on the contrast of the prostate. The obtained translation and rotation describes the intrafraction motion of the prostate. The algorithm was applied to 6270 dynamics over 114 scans of 29 patients and the results were validated by comparing to previously obtained fiducial marker tracking data of the same dataset. Our proposed tracking method was also retro-perspectively applied to cine-MR images acquired during MR-guided radiotherapy of our first prostate patient treated on the MR-Linac. The difference in the 3D translation results between the soft tissue and marker tracking was below 1 mm for 98.2% of the time. The mean translation at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.8 mm and Z: [Formula: see text] mm. The mean rotation results at 10 min were X: [Formula: see text], Y: 0.1 [Formula: see text] 0.6° and Z: 0.0 [Formula: see text] 0.7°. A fast, robust and accurate SST algorithm was developed which obviates the need for FMs during MR-guided prostate radiotherapy. To our knowledge, this is the first data using full 3D cine-MR images for real-time soft tissue prostate tracking, which is validated against previously obtained marker tracking data.


Subject(s)
Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging, Cine/methods , Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Algorithms , Fiducial Markers , Humans , Imaging, Three-Dimensional/standards , Magnetic Resonance Imaging, Cine/standards , Male , Movement , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Radiosurgery/standards , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy, Image-Guided/standards , Rotation
4.
Phys Med Biol ; 64(7): 07NT02, 2019 04 04.
Article in English | MEDLINE | ID: mdl-30794995

ABSTRACT

We have developed a method to determine intrafraction motion of the prostate through automatic fiducial marker (FM) tracking on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients undergoing prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold FMs, had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR examination consisted of 55 sequentially obtained 3D datasets ('dynamics'), acquired over a 11 s period, covering a total of 10 min. FM locations in the first dynamic were manually identified by a clinician, FM centers in subsequent dynamics were automatically determined. Center of mass (COM) translations and rotations were determined by calculating the rigid transformations between the FM template of the first and subsequent dynamics. The algorithm was applied to 7315 dynamics over 133 scans of 29 patients and the obtained results were validated by comparing the COM locations recorded by the clinician at the halfway-dynamic (after 5 min) and end dynamic (after 10 min). The mean COM translations at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.9 mm and Z: 0.9 [Formula: see text] 2.0 mm. The mean rotation results at 10 min were X: 0.1 [Formula: see text] 3.9°, Y: 0.0 [Formula: see text] 1.3° and Z: 0.1 [Formula: see text] 1.2°. The tracking success rate was 97.7% with a mean 3D COM error of 1.1 mm. We have developed a robust, fast and accurate FM tracking algorithm for cine-MR data, which allows for continuous monitoring of prostate motion during MR-guided radiotherapy (MRgRT). These results will be used to validate automatic prostate tracking based on soft-tissue contrast.


Subject(s)
Fiducial Markers , Magnetic Resonance Imaging, Cine/methods , Movement , Prostatic Neoplasms/surgery , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Algorithms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology
5.
Phys Med Biol ; 63(23): 235009, 2018 Nov 23.
Article in English | MEDLINE | ID: mdl-30468684

ABSTRACT

For the successful completion of medical interventional procedures, several concepts, such as daily positioning compensation, dose accumulation or delineation propagation, rely on establishing a spatial coherence between planning images and images acquired at different time instants over the course of the therapy. To meet this need, image-based motion estimation and compensation relies on fast, automatic, accurate and precise registration algorithms. However, image registration quickly becomes a challenging and computationally intensive task, especially when multiple imaging modalities are involved. In the current study, a novel framework is introduced to reduce the computational overhead of variational registration methods. The proposed framework selects representative voxels of the registration process, based on a supervoxel algorithm. Costly calculations are hereby restrained to a subset of voxels, leading to a less expensive spatial regularized interpolation process. The novel framework is tested in conjunction with the recently proposed EVolution multi-modal registration method. This results in an algorithm requiring a low number of input parameters, is easily parallelizable and provides an elastic voxel-wise deformation with a subvoxel accuracy. The performance of the proposed accelerated registration method is evaluated on cross-contrast abdominal T1/T2 MR-scans undergoing a known deformation and annotated CT-images of the lung. We also analyze the ability of the method to capture slow physiological drifts during MR-guided high intensity focused ultrasound therapies and to perform multi-modal CT/MR registration in the abdomen. Results have shown that computation time can be reduced by 75% on the same hardware with no negative impact on the accuracy.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods
6.
Clin Oncol (R Coll Radiol) ; 30(11): 692-701, 2018 11.
Article in English | MEDLINE | ID: mdl-30244830

ABSTRACT

Magnetic resonance imaging (MRI) is often combined with computed tomography (CT) in prostate radiotherapy to optimise delineation of the target and organs-at-risk (OAR) while maintaining accurate dose calculation. Such a dual-modality workflow requires two separate imaging sessions, and it has some fundamental and logistical drawbacks. Due to the availability of new MRI hardware and software solutions, CT examinations can be omitted for prostate radiotherapy simulations. All information for treatment planning, including electron density maps and bony anatomy, can nowadays be obtained with MRI. Such an MRI-only simulation workflow reduces delineation ambiguities, eases planning logistics, and improves patient comfort; however, careful validation of the complete MRI-only workflow is warranted. The first institutes are now adopting this MRI-only workflow for prostate radiotherapy. In this article, we will review technology and workflow requirements for an MRI-only prostate simulation workflow.


Subject(s)
Magnetic Resonance Imaging/methods , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Workflow , Humans , Male , Software
7.
Phys Med Biol ; 62(23): L41-L50, 2017 Nov 14.
Article in English | MEDLINE | ID: mdl-29135471

ABSTRACT

The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.


Subject(s)
Bone Neoplasms/radiotherapy , Lumbosacral Region/radiation effects , Magnetic Resonance Imaging/instrumentation , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Spinal Neoplasms/radiotherapy , Aged , Bone Neoplasms/secondary , Humans , Middle Aged , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Spinal Neoplasms/pathology
8.
Phys Med Biol ; 62(18): 7233-7248, 2017 Aug 21.
Article in English | MEDLINE | ID: mdl-28749375

ABSTRACT

The hybrid MRI-radiotherapy machines, like the MR-linac (Elekta AB, Stockholm, Sweden) installed at the UMC Utrecht (Utrecht, The Netherlands), will be able to provide real-time patient imaging during treatment. In order to take advantage of the system's capabilities and enable online adaptive treatments, a new generation of software should be developed, ranging from motion estimation to treatment plan adaptation. In this work we present a proof of principle adaptive pipeline designed for high precision stereotactic body radiation therapy (SBRT) suitable for sites affected by respiratory motion, like renal cell carcinoma (RCC). We utilized our research MRL treatment planning system (MRLTP) to simulate a single fraction 25 Gy free-breathing SBRT treatment for RCC by performing inter-beam replanning for two patients and one volunteer. The simulated pipeline included a combination of (pre-beam) 4D-MRI and (online) 2D cine-MR acquisitions. The 4DMRI was used to generate the mid-position reference volume, while the cine-MRI, via an in-house motion model, provided three-dimensional (3D) deformable vector fields (DVFs) describing the anatomical changes during treatment. During the treatment fraction, at an inter-beam interval, the mid-position volume of the patient was updated and the delivered dose was accurately reconstructed on the underlying motion calculated by the model. Fast online replanning, targeting the latest anatomy and incorporating the previously delivered dose was then simulated with MRLTP. The adaptive treatment was compared to a conventional mid-position SBRT plan with a 3 mm planning target volume margin reconstructed on the same motion trace. We demonstrate that our system produced tighter dose distributions and thus spared the healthy tissue, while delivering more dose to the target. The pipeline was able to account for baseline variations/drifts that occurred during treatment ensuring target coverage at the end of the treatment fraction.


Subject(s)
Dose Fractionation, Radiation , Magnetic Resonance Imaging , Particle Accelerators , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/instrumentation , Humans , Movement , Respiration , Time Factors
9.
Phys Med Biol ; 61(24): 8587-8595, 2016 12 21.
Article in English | MEDLINE | ID: mdl-27880737

ABSTRACT

To develop an automated radiotherapy treatment planning and optimization workflow to efficiently create patient specifically optimized clinical grade treatment plans for prostate cancer and to implement it in clinical practice. A two-phased planning and optimization workflow was developed to automatically generate 77Gy 5-field simultaneously integrated boost intensity modulated radiation therapy (SIB-IMRT) plans for prostate cancer treatment. A retrospective planning study (n = 100) was performed in which automatically and manually generated treatment plans were compared. A clinical pilot (n = 21) was performed to investigate the usability of our method. Operator time for the planning process was reduced to <5 min. The retrospective planning study showed that 98 plans met all clinical constraints. Significant improvements were made in the volume receiving 72Gy (V72Gy) for the bladder and rectum and the mean dose of the bladder and the body. A reduced plan variance was observed. During the clinical pilot 20 automatically generated plans met all constraints and 17 plans were selected for treatment. The automated radiotherapy treatment planning and optimization workflow is capable of efficiently generating patient specifically optimized and improved clinical grade plans. It has now been adopted as the current standard workflow in our clinic to generate treatment plans for prostate cancer.


Subject(s)
Organs at Risk/radiation effects , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Male , Pilot Projects , Prospective Studies , Radiotherapy Dosage , Rectum/radiation effects , Retrospective Studies , Urinary Bladder/radiation effects
10.
Br J Cancer ; 100(6): 979-84, 2009 Mar 24.
Article in English | MEDLINE | ID: mdl-19293810

ABSTRACT

Van Trommel et al have previously shown that serum human chorionic gonadotropin (hCG) cutoff levels can provide early prediction of resistance to first-line methotrexate (MTX) in patients with persistent trophoblastic disease (PTD). In this study, we validate this approach of prediction of resistance to single-agent chemotherapy in an independent and larger cohort of PTD patients using a different hCG assay. Receiver operating characteristics (ROC) curves were constructed to determine hCG cutoff levels and sensitivity between patients cured on single-agent chemotherapy (control group) and patients requiring change to combination chemotherapy (study group). Receiver operating characteristics analysis identified an hCG cutoff value of 737 IU l(-1) that enabled us to predict the subsequent development of single-agent chemotherapy resistance in 52% of patients before their fourth MTX course at 97.5% specificity. This would have enabled an earlier switch to combination chemotherapy reducing the MTX exposure by an average of 2.5 courses. The present findings confirm that serum hCG cutoff levels predict resistance to single-agent therapy earlier than traditional methods. Change to combination chemotherapy should be considered for patients whose serum hCG levels exceed these hCG cutoff values. For patients not exceeding the hCG cutoff levels, static or rising hCG levels should still be included in the criteria for change of chemotherapy.


Subject(s)
Antimetabolites, Antineoplastic/therapeutic use , Chorionic Gonadotropin/blood , Methotrexate/therapeutic use , Trophoblastic Neoplasms/blood , Trophoblastic Neoplasms/drug therapy , Adolescent , Adult , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Drug Resistance, Neoplasm , Female , Humans , Middle Aged
SELECTION OF CITATIONS