Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Bioanalysis ; 15(18): 1115-1128, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37681562

ABSTRACT

Background: Volumetric absorptive microsampling has emerged as a less invasive alternative to venous sampling for small-molecule pharmacokinetic studies, but its application to novel therapeutics such as antisense oligonucleotides (ASOs) is not well-established. Results: A workflow was developed using Mitra microsampling coupled with hybridization LC-MS/MS for accurate determination of fomivirsen, a 21-mer ASO, in human blood. Quantitative recovery was achieved regardless of blood hematocrit level or microsample age by implementing impact-assisted extraction. A thorough method evaluation confirmed sensitivity, linearity, precision/accuracy, matrix effect, metabolite interference and four months of microsample stability. Conclusion: The combined impact-assisted extraction and hybridization LC-MS/MS workflow demonstrated the successful quantitation of fomivirsen, establishing the validity and applicability of the approach for ASO drug candidates.


Subject(s)
Oligonucleotides, Antisense , Tandem Mass Spectrometry , Humans , Chromatography, Liquid , Nucleic Acid Hybridization
2.
Bioanalysis ; 14(12): 849-848, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35735179

ABSTRACT

Anahita Keyhani speaks to Sankeetha Nadarajah, Commissioning Editor.


Subject(s)
Cultural Diversity , Industry
3.
Bioanalysis ; 13(8): 609-619, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33847160

ABSTRACT

The 13th Global CRO Council (GCC) closed forum for bioanalysis was held in New Orleans, LA, USA on 5 April 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. While ICH M10 will cover requirements for reference standards, one of the biggest challenges facing the CRO community is the lack of consistency and completeness of Certificates of Analysis for reference standards used in regulated bioanalysis. Similar challenges exist with critical reagents (e.g., capture and detection antibodies) used for assays supporting biologics. The recommendations provided in this publication are the minimum requirements for the content that GCC members believe should be included in Certificates of Analysis for reference standards obtained from commercial vendors, sponsors and compendial suppliers, for use in regulated bioanalytical studies. In addition, recommendations for internal standards, metabolites and critical reagents are discussed.


Subject(s)
Antibodies/analysis , Biological Assay/standards , Humans , Reference Standards
4.
Biomark Med ; 13(14): 1209-1225, 2019 10.
Article in English | MEDLINE | ID: mdl-31379197

ABSTRACT

Aim: Detection of drug-induced dystrophin in patient muscle biopsy is a surrogate outcome measure for Duchenne muscular dystrophy. We sought to establish and validate an orthogonal approach to measurement of dystrophin protein and RNA in muscle biopsies. Materials & methods: Validated methods were developed for dystrophin western blotting, mass spectrometry, immunostaining and reverse transcriptase PCR of biopsy mRNA using muscle biopsy standards. Results: Both western blotting and mass spectrometry validated methods demonstrated good linearity, and acceptable precision and accuracy with a lower limit of quantitation at 1%. Immunostaining and reverse transcriptase PCR methods were shown to be reliable. Conclusion: The described orthogonal approach is sufficient to support measures of dystrophin as a surrogate outcome in a clinical trial.


Subject(s)
Drug Discovery , Dystrophin/analysis , Biopsy , Blotting, Western , Exons/genetics , Humans , Mass Spectrometry , RNA, Messenger/analysis
5.
Bioanalysis ; 11(12): 1129-1138, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31319683

ABSTRACT

The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: critical reagents; oligonucleotides; certificates of analysis; method transfer; high resolution mass spectrometry; flow cytometry; recent regulatory findings and case studies involving stability and nonclinical immunogenicity. Conclusions and consensus from discussions of these topics are included in this article.


Subject(s)
Certification , Chemistry Techniques, Analytical , Flow Cytometry , Mass Spectrometry , Oligonucleotides/analysis , Social Control, Formal , Societies, Scientific , Indicators and Reagents/chemistry
6.
Bioanalysis ; 11(7): 645-653, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30993999

ABSTRACT

Over the last decade, the use of biomarker data has become integral to drug development. Biomarkers are not only utilized for internal decision-making by sponsors; they are increasingly utilized to make critical decisions for drug safety and efficacy. As the regulatory agencies are routinely making decisions based on biomarker data, there has been significant scrutiny on the validation of biomarker methods. Contract research organizations regularly use commercially available immunoassay kits to validate biomarker methods. However, adaptation of such kits in a regulated environment presents significant challenges and was one of the key topics discussed during the 12th Global Contract Research Organization Council for Bioanalysis (GCC) meeting. This White Paper reports the GCC members' opinion on the challenges facing the industry and the GCC recommendations on the classification of commercial kits that can be a win-win for commercial kit vendors and end users.


Subject(s)
Biological Assay/methods , Biomarkers/analysis , Biological Assay/standards , Drug Discovery , Humans , Ligands , Pharmaceutical Preparations/chemistry , Pharmaceutical Preparations/metabolism , Pharmaceutical Preparations/standards , Quality Control , Reagent Kits, Diagnostic , Reference Standards , Societies, Pharmaceutical , Surveys and Questionnaires
7.
Bioanalysis ; 10(7): 433-444, 2018 Apr 01.
Article in English | MEDLINE | ID: mdl-29701066

ABSTRACT

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.


Subject(s)
Biological Assay/methods , Biomarkers/analysis , Biosimilar Pharmaceuticals/therapeutic use , China , Humans , Research Design
8.
Bioanalysis ; 9(22): 1761-1769, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29148829

ABSTRACT

AIM: Volumetric absorptive microsampling (VAMS) is a recent technology available for sampling and analyzing low blood volume. The present work describes the utilization of VAMS for the quantitation of naproxen and ritonavir in human blood using a novel bead-based impact-assisted extraction (IAE) procedure. RESULTS: Sampling volume accuracy of the VAMS device was independent of the blood hematocrit (HCT) level, however analyte recovery decreased with increasing HCT when extracted using ultrasonication. In contrast, IAE was unaffected by HCT, resulting in quantitative recovery for all levels evaluated. Precision and accuracy batches, as well as matrix effect evaluation, met acceptance criteria. CONCLUSION: The IAE procedure coupled with VAMS is immune to HCT biases affecting sampling volume and recovery.


Subject(s)
Blood Specimen Collection/methods , Adsorption , Chromatography, High Pressure Liquid , Dried Blood Spot Testing , Hematocrit , Humans , Naproxen/blood , Naproxen/isolation & purification , Ritonavir/blood , Ritonavir/isolation & purification , Sonication , Tandem Mass Spectrometry
9.
Bioanalysis ; 9(7): 505-516, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28339299

ABSTRACT

The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical services. The objective of this meeting was for GCC members to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at this closed forum included reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, biomarker assay validation, processed batch acceptance criteria, electronic laboratory notebooks and data integrity, Health Canada's Notice regarding replicates in matrix stability evaluations, critical reagents and regulatory approaches to counteract fraud. In order to obtain the pharma perspectives on some of these topics, the first joint CRO-Pharma Scientific Interchange Meeting was held on 12 November 2016, in Denver, Colorado, USA. The five topics discussed at this Interchange meeting were reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, processed batch acceptance criteria and electronic laboratory notebooks and data integrity. The conclusions from the discussions of these topics at both meetings are included in this report.


Subject(s)
Biomarkers/analysis , Chemistry Techniques, Analytical/standards , Data Collection/standards , Guidelines as Topic , Pharmaceutical Preparations/analysis , Drug Stability , Government Regulation , Humans , Research Report
10.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26916197

ABSTRACT

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Subject(s)
Biomarkers/analysis , Biosimilar Pharmaceuticals/analysis , Drug Evaluation, Preclinical/methods , Biomarkers/blood , Electronic Health Records , Laboratories , Societies, Medical , Validation Studies as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...