Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 13(6)2022 May 27.
Article in English | MEDLINE | ID: mdl-35744452

ABSTRACT

Wearable flexible piezo-resistive pressure sensors hold a wide-ranging potential in human health monitoring, electronic skin, robotic limbs, and other human-machine interfaces. Out of the most successful recent efforts for arterial pulse monitoring are sensors with micro-patterned conductive elastomers. However, a low-current output signal (typically in the range of nano-amperes) and bulky and expensive measurement equipment for useful signal acquisition inhibits their wearability. Herein, through a finite element analysis we establish the design rules for a highly sensitive piezo-resistive pressure sensor with an output that is high enough to be detectable by simple and inexpensive circuits and therefore ensure wearability. We also show that, out of four frequently reported micro-feature shapes in micro-patterned piezo-resistive sensors, the micro-dome and micro-pyramid yield the highest sensitivity. Furthermore, investigations of different conductivity values of micro-patterned elastomers found that coating the elastomer with a conductive material (usually metallic) leads to higher current response when compared to composited conductive elastomers. Finally, the geometric parameters and spatial configurations of micro-pyramid design of piezo-resistive sensors were optimized. The results show that an enhanced sensitivity and higher current output is achieved by the lower spatial density configuration of three micro-features per millimeter length, a smaller feature size of around 100 µm, and a 60-50 degrees pyramid angle.

2.
Nanotechnology ; 32(34)2021 Jun 04.
Article in English | MEDLINE | ID: mdl-34015767

ABSTRACT

Amongst the different graphene fabrication techniques, bipolar electrochemistry (BPE) has been recently reported as a simple, controllable, low cost, eco-friendly, and scalable method. It consists of a wirelessly placed carbon source between two feeding electrodes subjected to direct current (DC) voltage in a deionized water bath. Although the physicochemical characteristics of produced graphene have been evaluated, the exfoliation and deposition mechanisms are still unclear. In this study, a novel modified BPE system with an electrically-connected graphite-platinum couple acting as the bipolar electrode has been designed in order to decouple and investigate the contribution of anodic/cathodic exfoliation and deposition of graphene in the BPE process. Electron microscopy and Fourier transform infrared spectroscopy results indicate that both anodic and cathodic exfoliation of graphene could take place regardless of the type of polarization; however, the morphology and deposition rate highly depend on the polarization. Furthermore, the graphene fabricated by anodic exfoliation was found to show higher levels of oxidation compared to the graphene produced by cathodic exfoliation.

3.
Nanoscale Adv ; 3(20): 5948-5958, 2021 Oct 12.
Article in English | MEDLINE | ID: mdl-36132673

ABSTRACT

Label-free aptasensors can be a promising point-of-care biosensor for detecting various cancer diseases due to their selectivity, sensitivity, and lower cost of production and operation. In this study, a highly sensitive aptasensor based on gold-covered polyethylene terephthalate electrodes (PET/Au) decorated with bipolar exfoliated graphene is proposed as a possible contender for disposable label-free aptasensor applications. Bipolar electrochemical exfoliation enables simultaneous exfoliation, reduction, and deposition of graphene nanosheets on prospective electrodes. Our comparative study confirms that the bipolar exfoliated graphene deposited on the negative feeding electrode (i.e., reduced graphene oxide) possesses better electrochemical properties for aptasensing. The optimized aptasensor based on bipolar exfoliated graphene deposited on PET/Au electrodes exhibits a highly sensitive response of 4.07 µA log c -1 (unit of c, pM) which is linear in the range of 0.0007-20 nM, and has a low limit of detection of 0.65 pM (S/N = 3). The aptasensor establishes highly selective performance with a stability of 91.2% after 6 days. This study demonstrates that bipolar electrochemistry is a simple yet efficient technique that could provide high-quality graphene for biosensing applications. Considering its simplicity and efficiency, the BPE technique promises the development of feasible and affordable lab-on-chip and point-of-care cancer diagnosis technologies.

SELECTION OF CITATIONS
SEARCH DETAIL
...