Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38456883

ABSTRACT

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Hemodynamics , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
2.
JACC Cardiovasc Interv ; 7(5): 510-8, 2014 May.
Article in English | MEDLINE | ID: mdl-24852804

ABSTRACT

OBJECTIVES: The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial evaluated the safety and efficacy of the coronary Orbital Atherectomy System (OAS) to prepare de novo, severely calcified coronary lesions for stent placement. BACKGROUND: Despite advances in interventional techniques, treatment of calcified coronary lesions remains a challenge. Stent placement in these lesions may result in stent underexpansion, malapposition, and procedural complications. METHODS: ORBIT II is a prospective, multicenter, nonblinded clinical trial that enrolled 443 consecutive patients with severely calcified coronary lesions at 49 U.S. sites from May 25, 2010, to November 26, 2012. Investigators used the centrifugal action of the OAS diamond-coated crown to modify calcified lesions prior to stent placement. RESULTS: The pre-procedure mean minimal lumen diameter of 0.5 mm increased to 2.9 mm after the procedure. The primary safety endpoint was 89.6% freedom from 30-day major adverse cardiac events compared with the performance goal of 83%. The primary efficacy endpoint (residual stenosis <50% post-stent without in-hospital major adverse cardiac events) was 88.9% compared with the performance goal of 82%. Stent delivery occurred successfully in 97.7% of cases with <50% stenosis in 98.6% of subjects. Low rates of in-hospital Q-wave myocardial infarction (0.7%), cardiac death (0.2%), and target vessel revascularization (0.7%) were reported. CONCLUSIONS: The ORBIT II coronary OAS trial met both the primary safety and efficacy endpoints by significant margins. Preparation of severely calcified plaque with the OAS not only helped facilitate stent delivery, but improved both acute and 30-day clinical outcomes compared with the outcomes of historic control subjects in this difficult-to-treat patient population. (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions [ORBIT II]; NCT01092416).


Subject(s)
Atherectomy, Coronary/instrumentation , Coronary Stenosis/therapy , Vascular Calcification/therapy , Aged , Atherectomy, Coronary/adverse effects , Coronary Stenosis/diagnosis , Coronary Stenosis/mortality , Equipment Design , Female , Humans , Male , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/instrumentation , Prospective Studies , Severity of Illness Index , Stents , Time Factors , Treatment Outcome , United States , Vascular Calcification/diagnosis , Vascular Calcification/mortality
3.
J Cardiovasc Transl Res ; 4(2): 220-9, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21312013

ABSTRACT

The Diamondback 360® Orbital PAD System (DB360) is a novel orbital atherectomy system for the treatment of calcified lower extremity lesions associated with peripheral arterial disease (PAD). This percutaneous, endovascular system incorporates the use of centrifugal force and differential sanding to modify plaque morphologies. The mechanism of differential sanding discriminates between compliant arterial tissue and diseased fibro-calcific or calcific plaque. An eccentrically mounted diamond-coated crown orbits at high speeds and removes a thin layer of calcific plaque with each pass of the crown. The crown creates a more concentric, smooth vessel lumen with increased diameter, increased lesion compliance and improved blood flow while protecting the vessel media. As a result, the risk for post-procedure thrombus formation and potential for restenosis may be reduced. The risk of intra-procedural events (slow flow, hemolysis, spasm and pain) may be reduced due to the design of this orbital sanding system along with proper technique. Extensive benchtop, in vivo, and clinical testing has confirmed these results and is presented within this paper. In addition, guidelines for selecting the most appropriate crown size and type (solid versus classic) and step-by-step procedural technique and pharmacology information are presented. The DB360 System provides a safe, efficacious, and cost-effective endovascular method for PAD treatment. Careful understanding of procedural methods, use of pharmacological drugs, and understanding of device operation contributes to improved treatment success.


Subject(s)
Atherectomy/instrumentation , Calcinosis/surgery , Lower Extremity/blood supply , Peripheral Arterial Disease/surgery , Animals , Atherectomy/adverse effects , Equipment Design , Humans , Patient Selection , Risk Assessment , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL