Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Biophotonics ; 14(4): e202000453, 2021 04.
Article in English | MEDLINE | ID: mdl-33423394

ABSTRACT

The current method for determining the sun protection factor (SPF) requires erythema formation. Noninvasive alternatives have recently been suggested by several groups. Our group previously developed a functional sensor based on diffuse reflectance measurements with one UVB LED, which was previously evaluated on pig ear skin. Here we present the results of a systematic in vivo study using 12 sunscreens on 10 volunteers (skin types [ST] I-III). The relationship of the UVB-LED reflectance of unprotected skin and melanin index was determined for each ST. The spatial variation of the reflectance signal of different positions was analyzed and seems to be mainly influenced by sample inhomogeneity except for high-protection factors (PFs) where signal levels are close to detection noise. Despite the low-signal levels, a correlation of the measured LED-based UVB PF with SPF reference values from test institutes with R2 = 0.57 is obtained, suggesting a strong relationship of SPF and LED-based UVB-PF. Measured PFs tend to be lower for increasing skin pigmentation. The sensor design seems to be suitable for investigations where a fast measurement of relative changes of PFs, such as due to inhomogeneous application, bathing and sweating, is of interest.


Subject(s)
Sunscreening Agents , Ultraviolet Rays , Animals , Skin , Skin Pigmentation , Sun Protection Factor , Swine
2.
Skin Res Technol ; 27(4): 589-598, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33511672

ABSTRACT

OBJECTIVE: A mobile handheld snapshot hyperspectral imaging device was developed and tested for in vivo skin evaluation using a new spectral imaging technology. METHODS: The device is equipped with four different LED light sources (VIS, 810 nm, 850 nm, and 940 nm) for illumination. Based on a diffractive optical element (DOE) combined with a CMOS sensor chip, a snapshot hyperspectral imager is achieved for the application on human skin. The diffractive optical element (DOE) consists of a two-dimensional array of identically repeated diffractive microstructures. One hyperspectral image for all wavelength regions is taken within a few seconds. Complex recalculation of the VIS spectral distribution and image information from the received DOE image requires several minutes, depending on computing performance. A risk assessment on the irradiation sources shows no risk of harm due to the LED radiation. RESULTS: Skin tone color patches experiments reproducibly deliver images and spectra of different skin tones. First in vivo use of the device identified pigmentation changes within the field of view. CONCLUSION: We present a working mobile snapshot hyperspectral imaging tool based on diffractive optical elements. This device or future developments thereof can be used for broad skin evaluation in vivo.


Subject(s)
Hyperspectral Imaging , Skin Pigmentation , Diagnostic Imaging , Humans , Lighting , Skin/diagnostic imaging
3.
Skin Res Technol ; 27(4): 486-493, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33231349

ABSTRACT

OBJECTIVE: A handheld device was developed and qualified for in vivo human skin evaluation using laser speckle imaging technology. METHODS: Each laser speckle device prototype allows the choice of up to three different laser wavelengths in the range of 400 nm to 800 nm in total. Speckle pattern analysis gives various speckle parameters, for example, speckle contrast, speckle size, speckle modulation or fractal dimension. The developed laser speckle device prototypes were evaluated investigating three skin issues. RESULTS: We receive reproducible results from the speckle imaging device. For skin ageing, we found significant changes within three age groups. The effect of a methyl nicotinate treatment was clearly visible and quantifiable using a moorFLPI device as well as our speckle imaging device. In terms of basal cell carcinoma diagnosis, we found significant differences between normal and diseased skin, even though the number of samples was limited. CONCLUSION: As shown with first application examples, it was possible to demonstrate the potential of the method for skin evaluation in vivo.


Subject(s)
Skin Aging , Skin , Humans , Laser Speckle Contrast Imaging , Lasers , Skin/diagnostic imaging
4.
J Biophotonics ; 14(2): e202000348, 2021 02.
Article in English | MEDLINE | ID: mdl-33025740

ABSTRACT

The sun protection factor (SPF) values are currently determined using an invasive procedure, in which the volunteers are irradiated with ultraviolet (UV) light. Non-invasive approaches based on hybrid diffuse reflectance spectroscopy (HDRS) have shown a good correlation with conventional SPF testing. Here, we present a novel compact and adjustable DRS test system. The in vivo measurements were performed using a multi-lambda-LED light source and an 84-channel imaging spectrograph with a fiber optic probe for detection. A transmission spectrum was calculated based on the reflectance measured with sunscreen and the reflectance measured without sunscreen. The preexposure in vitro spectrum was fitted to the in vivo spectrum. Each of the 11 test products was investigated on 10 volunteers. The SPF and UVA-PF values obtained by this new approach were compared with in vivo SPF results determined by certified test institutes. A correlation coefficient R2 = 0.86 for SPF, and R2 = 0.92 for UVA-PF were calculated. Having examined various approaches to apply the HDRS principle, the method we present was found to produce valid and reproducible results, suggesting that the multi-lambda-LED device is suitable for in-vivo SPF testing based on the HDRS principle as well as for in-vivo UVA-PF measurements.


Subject(s)
Sun Protection Factor , Sunscreening Agents , Humans , Spectrum Analysis , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...