Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
ACS Meas Sci Au ; 3(2): 113-119, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37090261

ABSTRACT

Considering the challenges in isolating circulating tumor cells (CTCs) pertaining to cellular stress and purity, we report the application of a blood microfiltration device as an optimal approach for noninvasive liquid biopsy to target CTCs. We experimentally analyzed the filtration behavior of the microfilter using pressure sensing to separate tumor cells from leukocytes in whole blood. This approach achieved an average recovery of >96% of the spiked tumor cells and depletion of >99% of total leukocytes. Furthermore, we carried out genomic profiling of the CTCs using the blood microfiltration device. The method was also applied in a clinical setting; DNA amplification was performed using a small number of microfiltered CTCs and epidermal growth factor receptor mutations were successfully detected to characterize the efficacy of molecularly targeted drugs against lung cancer. Overall, the proposed method can provide a tool for evaluating efficient filtration pressure to concentrate CTCs from whole blood.

2.
Sci Rep ; 11(1): 8672, 2021 04 21.
Article in English | MEDLINE | ID: mdl-33883603

ABSTRACT

Recent studies have shown that extracellular vesicles (EVs) can be utilized as appropriate and highly specific biomarkers in liquid biopsy for the diagnosis and prognosis of serious illness. However, there are few methods that can collect and isolate miRNA in EVs simply, quickly and efficiently using general equipment such as a normal centrifuge. In this paper, we developed an advanced glass membrane column (AGC) device incorporating a size-controlled macro-porous glass (MPG) membrane with a co-continuous structure to overcome the limitations of conventional EV collection and miRNA extraction from the EVs. The size of macro-pores in the MPG membrane could be accurately controlled by changing the heating temperature and time on the basis of spinodal decomposition of B2O3, Na2O, and SiO2 in phase separation. The AGC device with an MPG membrane could collect the EVs simply and quickly (< 10 min) from cell culture supernatant, serum and urine. This AGC device could extract miRNA from the EVs captured in the MPG membrane with high efficiency when combined with a miRNA extraction solution. We suggest that the AGC device with an MPG membrane can be useful for the diagnosis and prognosis of serious illness using of EVs in various kinds of body fluids.


Subject(s)
Extracellular Vesicles/genetics , MicroRNAs/isolation & purification , Extracellular Vesicles/chemistry , Extracellular Vesicles/ultrastructure , Glass , Hep G2 Cells , Humans , Liquid Biopsy/methods , Membranes , MicroRNAs/urine , Microscopy, Electron, Scanning , Microscopy, Electron, Transmission , Porosity
SELECTION OF CITATIONS
SEARCH DETAIL