2.
Drug Test Anal ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769669

ABSTRACT

Synthetic opioids have been associated globally with adverse effects in drug users. The nitazene group of drugs is a relatively new addition to the synthetic opioid class emerging in Europe in 2019. Some nitazenes have been shown to be more potent than fentanyl. Overdose clusters in heroin users in Dublin (57 cases) and Cork (20 cases), Ireland, in November and December 2023, respectively, prompted a rapid response from a number of Irish laboratories to identify the substance(s) of concern. Light brown (tan) powders were obtained from cases associated with overdoses, and the results from these analyses by collaboration of four laboratories are reported here. The samples were found to contain N-pyrrolidino protonitazene (protonitazepyne), caffeine, paracetamol, benzoic acid and mannitol.

4.
Sensors (Basel) ; 10(7): 6439-62, 2010.
Article in English | MEDLINE | ID: mdl-22163559

ABSTRACT

In an ongoing programme to develop characterization strategies relevant to biosensors for in-vivo monitoring, glucose biosensors were fabricated by immobilizing the enzyme glucose oxidase (GOx) on 125 µm diameter Pt cylinder wire electrodes (Pt(C)), using three different methods: before, after or during the amperometric electrosynthesis of poly(ortho-phenylenediamine), PoPD, which also served as a permselective membrane. These electrodes were calibrated with H(2)O(2) (the biosensor enzyme signal molecule), glucose, and the archetypal interference compound ascorbic acid (AA) to determine the relevant polymer permeabilities and the apparent Michaelis-Menten parameters for glucose. A number of selectivity parameters were used to identify the most successful design in terms of the balance between substrate sensitivity and interference blocking. For biosensors electrosynthesized in neutral buffer under the present conditions, entrapment of the GOx within the PoPD layer produced the design (Pt(C)/PoPD-GOx) with the highest linear sensitivity to glucose (5.0 ± 0.4 µA cm(-2) mM(-1)), good linear range (K(M) = 16 ± 2 mM) and response time (< 2 s), and the greatest AA blocking (99.8% for 1 mM AA). Further optimization showed that fabrication of Pt(C)/PoPD-GOx in the absence of added background electrolyte (i.e., electropolymerization in unbuffered enzyme-monomer solution) enhanced glucose selectivity 3-fold for this one-pot fabrication protocol which provided AA-rejection levels at least equal to recent multi-step polymer bilayer biosensor designs. Interestingly, the presence of enzyme protein in the polymer layer had opposite effects on permselectivity for low and high concentrations of AA, emphasizing the value of studying the concentration dependence of interference effects which is rarely reported in the literature.


Subject(s)
Biosensing Techniques , Enzymes, Immobilized , Glucose/analysis , Polymers/chemistry , Calibration , Hydrogen Peroxide/chemistry , Kinetics , Permeability , Reproducibility of Results
5.
Biosens Bioelectron ; 22(7): 1466-73, 2007 Feb 15.
Article in English | MEDLINE | ID: mdl-16887344

ABSTRACT

Biosensors were fabricated at neutral pH by sequentially depositing the polycation polyethyleneimine (PEI), the stereoselective enzyme L-glutamate oxidase (GluOx) and the permselective barrier poly-ortho-phenylenediamine (PPD) onto 125-microm diameter Pt wire electrodes (Pt/PEI/GluOx/PPD). These devices were calibrated amperometrically at 0.7 V versus SCE to determine the Michaelis-Menten parameters for enzyme substrate, l-glutamate (Glu) and co-substrate, dioxygen. The presence of PEI produced a 10-fold enhancement in the detection limit for Glu (approximately 20 nM) compared with the corresponding PEI-free configurations (Pt/GluOx/PPD), without undermining their fast response time (approximately 2 s). Most remarkable was the finding that, although some designs of PEI-containing biosensors showed a 10-fold increase in linear region sensitivity to Glu, their oxygen dependence remained low.


Subject(s)
Amino Acid Oxidoreductases , Biosensing Techniques/instrumentation , Glutamic Acid/analysis , Oxygen , Polyamines , Kinetics , Polyelectrolytes , Substrate Specificity
6.
Chem Commun (Camb) ; (18): 2128-30, 2004 Sep 21.
Article in English | MEDLINE | ID: mdl-15368008

ABSTRACT

A biosensor selectivity coefficient defined for poly(o-phenylenediamine) electrosynthesised onto Pt microdisks and cylinders was unexpectedly found to change as the scale of the electrodes decreased, mainly due to enhanced permeability of a ubiquitous interference species in biological systems, ascorbic acid.