Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
ACS Appl Mater Interfaces ; 9(41): 35958-35967, 2017 Oct 18.
Article in English | MEDLINE | ID: mdl-28948762

ABSTRACT

Omnidirectionally stretchable photodetectors are limited by difficulties in designing material and fabrication processes that enable stretchability in multiaxial directions. Here, we propose a new approach involving an organic-inorganic p-n heterojunction photodetector comprised of free-standing ZnO nanorods grown on a poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate transport layer coated on a three-dimensional micropatterned stretchable substrate containing bumps and valleys. This structure allows for efficient absorption of stretching strain. This approach allows the device to accommodate large tensile strain in all of the directions. The device behaves as a photogated p-n heterojunction photodetector in which current modulation was obtained by sensing the mechanisms that rely on photovoltage and photogating effects. The device exhibits a high photoresponse to UV light and reliable electrical performance under applied stretching in uniaxial and omniaxial directions. Furthermore, the device can be easily and conformally attached to a human wrist. This allowed us to investigate the response of the device to UV light during human activity.

2.
Adv Mater ; 29(42)2017 Nov.
Article in English | MEDLINE | ID: mdl-28960525

ABSTRACT

The development of omnidirectionally stretchable pressure sensors with high performance without stretching-induced interference has been hampered by many challenges. Herein, an omnidirectionally stretchable piezoresistive pressure-sensing device is demonstrated by combining an omniaxially stretchable substrate with a 3D micropattern array and solution-printing of electrode and piezoresistive materials. A unique substrate structural design and materials mean that devices that are highly sensitive are rendered, with a stable out-of-plane pressure response to both static (sensitivity of 0.5 kPa-1 and limit of detection of 28 Pa) and dynamic pressures and the minimized in-plane stretching responsiveness (a small strain gauge factor of 0.17), achieved through efficient strain absorption of the electrode and sensing materials. The device can detect human-body tremors, as well as measure the relative elastic properties of human skin. The omnidirectionally stretchable pressure sensor with a high pressure sensitivity and minimal stretch-responsiveness yields great potential to skin-attachable wearable electronics, human-machine interfaces, and soft robotics applications.

3.
PLoS One ; 11(10): e0165553, 2016.
Article in English | MEDLINE | ID: mdl-27788254

ABSTRACT

BACKGROUND: Although acute bronchitis is quite common, there is relatively limited information regarding the microorganisms that are involved in this illness. METHODS: We performed a prospective study of acute bronchitis at 31 hospitals and clinics in Korea from July 2011 to June 2012. Sputum specimens were collected for polymerase chain reaction (PCR) and culture of microorganisms. RESULTS: Of the 811 enrolled patients, 291 had acceptable sputum specimens that were included for analysis of the etiologic distribution. With multiplex PCR testing, viruses were identified in 36.1% (105/291), most commonly rhinovirus (25.8%) and coronavirus (3.8%). Typical bacteria were isolated in 126/291 (43.3%) patients. Among these patients Haemophilus influenzae (n = 39) and Streptococcus pneumoniae (n = 30) were isolated most commonly; atypical bacteria were identified in 44 (15.1%) patients. Bacteria-only, virus-only, and mixed infections (bacteria plus virus) accounted for 36.7% (98/291), 17.2% (50/291), and 18.9% (55/291) of infections, respectively. In particular, 52.4% of patients with viral infection had a concurrent bacterial infection, and rhinovirus was the most common virus in mixed infections (40/55). Additionally, infections with typical bacteria were more common in patients with chronic lung disease (p = 0.029), and typical bacterial infections showed a trend towards a higher prevalence with older age (p = 0.001). CONCLUSIONS: Bacteria were associated with almost half of community-acquired acute bronchitis cases. Additional studies are required to further illuminate the role of bacteria and to identify patient groups most likely to benefit from antibiotic treatment.


Subject(s)
Bacterial Infections/microbiology , Bronchitis/microbiology , Community-Acquired Infections/microbiology , Acute Disease , Adult , Humans , Prospective Studies , Republic of Korea
4.
Adv Mater ; 28(16): 3069-77, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26917352

ABSTRACT

A mogul-patterned stretchable substrate with multidirectional stretchability and minimal fracture of layers under high stretching is fabricated by double photolithography and soft lithography. Au layers and a reduced graphene oxide chemiresistor on a mogul-patterned poly(dimethylsiloxane) substrate are stable and durable under various stretching conditions. The newly designed mogul-patterned stretchable substrate shows great promise for stretchable electronics.


Subject(s)
Elasticity , Electronics/instrumentation , Electronics/methods , Polymers/chemistry , Dimethylpolysiloxanes/chemistry , Elastomers , Gold/chemistry , Graphite/chemistry , Printing
5.
J Korean Med Sci ; 30(10): 1446-52, 2015 10.
Article in English | MEDLINE | ID: mdl-26425041

ABSTRACT

The role of atypical bacteria and the effect of antibiotic treatments in acute bronchitis are still not clear. This study was conducted at 22 hospitals (17 primary care clinics and 5 university hospitals) in Korea. Outpatients (aged ≥ 18 yr) who had an acute illness with a new cough and sputum (≤ 30 days) were enrolled in 2013. Multiplex real-time polymerase chain reaction (RT-PCR) was used to detect five atypical bacteria. A total of 435 patients were diagnosed as having acute bronchitis (vs. probable pneumonia, n = 75), and 1.8% (n = 8) were positive for atypical pathogens (Bordetella pertussis, n = 3; B. parapertussis, n = 0; Mycoplasma pneumoniae, n = 1; Chlamydophila pneumoniae, n = 3; Legionella pneumophila, n = 1). Among clinical symptoms and signs, only post-tussive vomiting was more frequent in patients with atypical pathogens than those without (P = 0.024). In all, 72.2% of the enrolled patients received antibiotic treatment at their first visits, and ß-lactams (29.4%) and quinolones (20.5%) were the most commonly prescribed agents. In conclusion, our study demonstrates that the incidence of atypical pathogens is low in patients with acute bronchitis, and the rate of antibiotic prescriptions is high.


Subject(s)
Bordetella parapertussis/isolation & purification , Bordetella pertussis/isolation & purification , Bronchitis/microbiology , Chlamydophila pneumoniae/isolation & purification , Legionella pneumophila/isolation & purification , Mycoplasma pneumoniae/isolation & purification , Anti-Bacterial Agents/therapeutic use , Bordetella parapertussis/genetics , Bordetella pertussis/genetics , Bronchitis/drug therapy , Chlamydophila pneumoniae/genetics , Community-Acquired Infections/microbiology , Female , Humans , Hypertension/complications , Legionella pneumophila/genetics , Male , Middle Aged , Mycoplasma pneumoniae/genetics , Real-Time Polymerase Chain Reaction , Republic of Korea , Sputum/microbiology
6.
ACS Nano ; 9(9): 8801-10, 2015 Sep 22.
Article in English | MEDLINE | ID: mdl-26277994

ABSTRACT

Monitoring of human activities can provide clinically relevant information pertaining to disease diagnostics, preventive medicine, care for patients with chronic diseases, rehabilitation, and prosthetics. The recognition of strains on human skin, induced by subtle movements of muscles in the internal organs, such as the esophagus and trachea, and the motion of joints, was demonstrated using a self-powered patchable strain sensor platform, composed on multifunctional nanocomposites of low-density silver nanowires with a conductive elastomer of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate/polyurethane, with high sensitivity, stretchability, and optical transparency. The ultra-low-power consumption of the sensor, integrated with both a supercapacitor and a triboelectric nanogenerator into a single transparent stretchable platform based on the same nanocomposites, results in a self-powered monitoring system for skin strain. The capability of the sensor to recognize a wide range of strain on skin has the potential for use in new areas of invisible stretchable electronics for human monitoring. A new type of transparent, stretchable, and ultrasensitive strain sensor based on a AgNW/PEDOT:PSS/PU nanocomposite was developed. The concept of a self-powered patchable sensor system integrated with a supercapacitor and a triboelectric nanogenerator that can be used universally as an autonomous invisible sensor system was used to detect the wide range of strain on human skin.


Subject(s)
Biosensing Techniques , Motion , Nanotechnology , Nanowires/chemistry , Elastomers/chemistry , Electronics , Equipment Design , Humans , Polystyrenes/chemistry , Polyurethanes/chemistry , Silver/chemistry
7.
Sci Rep ; 5: 12705, 2015 Jul 30.
Article in English | MEDLINE | ID: mdl-26223845

ABSTRACT

Mechanically adaptive electronic skins (e-skins) emulate tactition and thermoception by cutaneous mechanoreceptors and thermoreceptors in human skin, respectively. When exposed to multiple stimuli including mechanical and thermal stimuli, discerning and quantifying precise sensing signals from sensors embedded in e-skins are critical. In addition, different detection modes for mechanical stimuli, rapidly adapting (RA) and slowly adapting (SA) mechanoreceptors in human skin are simultaneously required. Herein, we demonstrate the fabrication of a highly sensitive, pressure-responsive organic field-effect transistor (OFET) array enabling both RA- and SA- mode detection by adopting easily deformable, mechano-electrically coupled, microstructured ferroelectric gate dielectrics and an organic semiconductor channel. We also demonstrate that the OFET array can separate out thermal stimuli for thermoreception during quantification of SA-type static pressure, by decoupling the input signals of pressure and temperature. Specifically, we adopt piezoelectric-pyroelectric coupling of highly crystalline, microstructured poly(vinylidene fluoride-trifluoroethylene) gate dielectric in OFETs with stimuli to allow monitoring of RA- and SA-mode responses to dynamic and static forcing conditions, respectively. This approach enables us to apply the sensor array to e-skins for bio-monitoring of humans and robotics.


Subject(s)
Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Skin Temperature , Humans , Sensitivity and Specificity
8.
Atherosclerosis ; 242(1): 8-12, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26160041

ABSTRACT

BACKGROUND/OBJECTIVE: Familial hypercholesterolemia (FH) is an autosomal dominant disorder caused by mutations in LDLR, APOB, or PCSK9. Polygenicity is a plausible cause in mutation-negative FH patients based on LDL cholesterol (LDL-C)-associated single nucleotide polymorphisms (SNPs) identified by the Global Lipids Genetics Consortium (GLGC). However, there are limited data regarding the polygenic cause of FH in Asians. METHODS: We gathered data from 66 mutation-negative and 31 mutation-positive Korean FH patients, as well as from 2274 controls who participated in the Korean Health Examinee (HEXA) shared control study. We genotyped the patients for six GLGC SNPs and four East Asian LDL-C-associated SNPs and compared SNP scores among patient groups and controls. RESULTS: Weighted mean 6- and 4-SNP scores (0.67 [SD = 0.07] and 0.46 [0.11], respectively) were both significantly associated with LDL-C levels in controls (p = 2.1 × 10(-4), R(2) = 0.01 and p = 5.0 × 10(-12), R(2) = 0.02, respectively). Mutation-negative FH patients had higher 6-SNP (0.72 [0.07]) and 4-SNP (0.49 [0.08]) scores than controls (p = 1.8 × 10(-8) and p = 3.6 × 10(-3), respectively). We also observed higher scores in mutation-positive FH patients compared with controls, but the difference did not reach statistical significance. CONCLUSION: The present study demonstrates the utility of SNP score analysis for identifying polygenic FH in Korean patients by showing that small-effect common SNPs may cumulatively elevate LDL-C levels.


Subject(s)
Apolipoprotein B-100/genetics , Asian People/genetics , Hyperlipoproteinemia Type II/genetics , Multifactorial Inheritance , Proprotein Convertases/genetics , Receptors, LDL/genetics , Serine Endopeptidases/genetics , Adult , Aged , Cardiovascular Diseases/epidemiology , Cholesterol, HDL/blood , Cholesterol, LDL/blood , Comorbidity , Diabetes Mellitus/epidemiology , Female , Genes, Dominant , Genotype , Humans , Hyperlipoproteinemia Type II/blood , Hyperlipoproteinemia Type II/ethnology , Male , Middle Aged , Mutation , Polymorphism, Single Nucleotide , Proprotein Convertase 9 , Republic of Korea/epidemiology , Risk Factors , Triglycerides/blood
9.
PLoS One ; 10(5): e0126706, 2015.
Article in English | MEDLINE | ID: mdl-25962062

ABSTRACT

Familial hypercholesterolemia (FH) is a genetic disorder with an increased risk of early-onset coronary artery disease. Although some clinically diagnosed FH cases are caused by mutations in LDLR, APOB, or PCSK9, mutation detection rates and profiles can vary across ethnic groups. In this study, we aimed to provide insight into the spectrum of FH-causing mutations in Koreans. Among 136 patients referred for FH, 69 who met Simon Broome criteria with definite family history were enrolled. By whole-exome sequencing (WES) analysis, we confirmed that the 3 known FH-related genes accounted for genetic causes in 23 patients (33.3%). A substantial portion of the mutations (19 of 23 patients, 82.6%) resulted from 17 mutations and 2 copy number deletions in LDLR gene. Two mutations each in the APOB and PCSK9 genes were verified. Of these anomalies, two frameshift deletions in LDLR and one mutation in PCSK9 were identified as novel causative mutations. In particular, one novel mutation and copy number deletion were validated by co-segregation in their relatives. This study confirmed the utility of genetic diagnosis of FH through WES.


Subject(s)
Genetic Testing/methods , Hypercholesterolemia/diagnosis , Hypercholesterolemia/genetics , Adult , Aged , Apolipoproteins B/genetics , Asian People , Female , Humans , Male , Middle Aged , Mutation , Proprotein Convertase 9 , Proprotein Convertases/genetics , Receptors, LDL/genetics , Serine Endopeptidases/genetics
10.
Small ; 11(25): 3054-65, 2015 Jul 01.
Article in English | MEDLINE | ID: mdl-25703808

ABSTRACT

Ultraviolet (UV) photodetectors based on ZnO nanostructure/graphene (Gr) hybrid-channel field-effect transistors (FETs) are investigated under illumination at various incident photon intensities and wavelengths. The time-dependent behaviors of hybrid-channel FETs reveal a high sensitivity and selectivity toward the near-UV region at the wavelength of 365 nm. The devices can operate at low voltage and show excellent selectivity, high responsivity (RI ), and high photoconductive gain (G). The change in the transfer characteristics of hybrid-channel FETs under UV light illumination allows to detect both photovoltage and photocurrent. The shift of the Dirac point (V Dirac ) observed during UV exposure leads to a clearer explanation of the response mechanism and carrier transport properties of Gr, and this phenomenon permits the calculation of electron concentration per UV power density transferred from ZnO nanorods and ZnO nanoparticles to Gr, which is 9 × 10(10) and 4 × 10(10) per mW, respectively. The maximum values of RI and G infer from the fitted curves of RI and G versus UV intensity are 3 × 10(5) A W(-1) and 10(6) , respectively. Therefore, the hybrid-channel FETs studied herein can be used as UV sensing devices with high performance and low power consumption, opening up new opportunities for future optoelectronic devices.

11.
Nanoscale ; 6(24): 15144-50, 2014 Dec 21.
Article in English | MEDLINE | ID: mdl-25374120

ABSTRACT

Piezoelectric coupling phenomena in a graphene field-effect transistor (GFET) with a nano-hybrid channel of chemical-vapor-deposited Gr (CVD Gr) and vertically aligned ZnO nanorods (NRs) under mechanical pressurization were investigated. Transfer characteristics of the hybrid channel GFET clearly indicated that the piezoelectric effect of ZnO NRs under static or dynamic pressure modulated the channel conductivity (σ) and caused a positive shift of 0.25% per kPa in the Dirac point. However, the GFET without ZnO NRs showed no change in either σ or the Dirac point. Analysis of the Dirac point shifts indicated transfer of electrons from the CVD Gr to ZnO NRs due to modulation of their interfacial barrier height under pressure. High responsiveness of the hybrid channel device with fast response and recovery times was evident in the time-dependent behavior at a small gate bias. In addition, the hybrid channel FET could be gated by mechanical pressurization only. Therefore, a piezoelectric-coupled hybrid channel GFET can be used as a pressure-sensing device with low power consumption and a fast response time. Hybridization of piezoelectric 1D nanomaterials with a 2D semiconducting channel in FETs enables a new design for future nanodevices.

12.
J Korean Med Sci ; 29(9): 1232-9, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25246741

ABSTRACT

Epidemiological data of Bordetella pertussis infection among adolescents and adults are limited in Korea. Patients (≥ 11 yr of age) with a bothersome cough for less than 30 days were enrolled during a 1-yr period at 22 hospitals in Korea. Nasopharyngeal swabs were collected for polymerase chain reaction (PCR) and for bacteriologic culture. In total, 490 patients were finally enrolled, and 34 (6.9%) patients tested positive for B. pertussis; cough duration (14.0 days [7.0-21.0 days]) and age distribution were diverse. The incidence was the highest in secondary referral hospitals, compared to primary care clinics or tertiary referral hospitals (24/226 [10.6%] vs. 3/88 [3.4%] vs. 7/176 [4.0%], P = 0.012), and the peak incidence was observed in February and August (15.8% and 15.9%), with no confirmed cases between March and June. In the multivariate analysis, post-tussive vomiting was significantly associated with pertussis (odds ratio, 2.508; 95% confidence interval, 1.146-5.486) and secondary referral hospital showed a borderline significance. In conclusion, using a PCR-based method, 6.9% of adolescent and adult patients with an acute cough illness had pertussis infection in an outpatient setting. However, hospital levels and seasonal trends must be taken into account to develop a better strategy for controlling pertussis.


Subject(s)
Bordetella pertussis/genetics , DNA, Bacterial/analysis , Polymerase Chain Reaction , Whooping Cough/epidemiology , Adolescent , Adult , Child , Demography , Female , Humans , Incidence , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Republic of Korea/epidemiology , Seasons , Vomiting/etiology , Whooping Cough/microbiology , Whooping Cough/pathology , Young Adult
13.
Adv Mater ; 26(5): 796-804, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24493054

ABSTRACT

Diverse signals generated from the sensing elements embedded in flexible electronic skins (e-skins) are typically interfered by strain energy generated through processes such as touching, bending, stretching or twisting. Herein, we demonstrate a flexible bimodal sensor that can separate a target signal from the signal by mechanical strain through the integration of a multi-stimuli responsive gate dielectric and semiconductor channel into the single field-effect transistor (FET) platform.

14.
J Nanosci Nanotechnol ; 13(12): 8002-6, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24266180

ABSTRACT

During the operational service of flexible electronic systems, component devices are subject to not only mechanical deformation but also environmental stimulation such as temperature and humidity. Therefore, the stability of flexible devices under simultaneous loading of multi-variable environmental factors including mechanical deformation needs to be studied. In this work, changes in device characteristics under simultaneous mechanical bending and heating of organic thin film transistors (OTFTs) were investigated in a mechanical bending system having capability of substrate heating. Simultaneous loading of mechanical deformation and heating of OTFTs accelerated the change of device characteristics such as field-effect mobility, threshold voltage, and subthreshold swing at elevated temperature. The results indicate that the stability of flexible devices under multi-variable loading needs to be tested for better understanding of the electrical behaviours of device characteristics in flexible electronics.

15.
ACS Nano ; 5(9): 7069-76, 2011 Sep 27.
Article in English | MEDLINE | ID: mdl-21838251

ABSTRACT

Physically responsive field-effect transistors (physi-FETs) that are sensitive to physical stimuli have been studied for decades. The important issue for separating the responses of sensing materials from interference by other subcomponents in a FET transducer under global physical stimuli has not been completely resolved. In addition, challenges remain with regard to the design and employment of smart materials for flexible physi-FETs with a large electro-physical coupling effect. In this article, we propose the direct integration of nanocomposite (NC) gate dielectrics of barium titanate (BT) nanoparticles (NPs) and highly crystalline poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) into flexible organic FETs to achieve a large electro-physical coupling effect. Additionally, a new alternating current biasing method is proposed for precise extraction and quantification of tiny variations in the remnant polarization of NCs caused by mechanical stimuli. An investigation of physi-FETs under static mechanical stimuli revealed the first ever reported giant, positive piezoelectric coefficients of d(33) up to 960 pC/N in the NCs. The large coefficients are presumably due to the significant contributions of the intrinsic positive piezoelectricity of the BT NPs and P(VDF-TrFE) crystallites.

16.
Med Phys ; 34(11): 4092-7, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18072475

ABSTRACT

The stationary grid commonly used with a digital x-ray detector causes a moiré interference pattern due to the inadequate sampling of the grid shadows by the detector pixels. There are limitations with the previous methods used to remove the moiré such as imperfect electromagnetic interference shielding and the loss of image information. A new method is proposed for removing the moiré pattern by integrating a carbon-interspaced high precision x-ray grid with high grid line uniformity with the detector for frequency matching. The grid was aligned to the detector by translating and rotating the x-ray grid with respect to the detector using microcontrolled alignment mechanism. The gap between the grid and the detector surface was adjusted with micrometer precision to precisely match the projected grid line pitch to the detector pixel pitch. Considering the magnification of the grid shadows on the detector plane, the grids were manufactured such that the grid line frequency was slightly higher than the detector sampling frequency. This study examined the factors that affect the moiré pattern, particularly the line frequency and displacement. The frequency of the moiré pattern was found to be sensitive to the angular displacement of the grid with respect to the detector while the horizontal translation alters the phase but not the moiré frequency. The frequency of the moiré pattern also decreased with decreasing difference in frequency between the grid and the detector, and a moiré-free image was produced after complete matching for a given source to detector distance. The image quality factors including the contrast, signal-to-noise ratio and uniformity in the images with and without the moiré pattern were investigated.


Subject(s)
Carbon/chemistry , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography/methods , X-Ray Intensifying Screens , Aluminum , Computer Simulation , Humans , Models, Statistical , Moire Topography , Phantoms, Imaging , Radiation Dosage , Reproducibility of Results , Scattering, Radiation , Technology, Radiologic , X-Rays
17.
In. International Leprosy Congress, 12. International Leprosy Congress, 12/Proceedings. New Delhi, s.n, 1984. p.290-292, tab.
Non-conventional in English | LILACS-Express | Sec. Est. Saúde SP, HANSEN, Hanseníase Leprosy, SESSP-ILSLACERVO, Sec. Est. Saúde SP | ID: biblio-1246415
18.
In. International Leprosy Congress, 11; Congresso Internacional de Leprologia, 11. International Leprosy Congress, 11/Workshop. Mexico City, I.L.A, 1978. p.1-3.
Non-conventional in English | Sec. Est. Saúde SP, HANSEN, Hanseníase Leprosy, SESSP-ILSLACERVO, Sec. Est. Saúde SP | ID: biblio-1246082

Subject(s)
Leprosy
SELECTION OF CITATIONS
SEARCH DETAIL
...