Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Adv Mater ; : e2400091, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38573312

ABSTRACT

Crystallographic characteristics, including grain boundaries and crystallographic orientation of each grain, are crucial in defining the properties of two-dimensional materials (2DMs). To date, local microstructure analysis of 2DMs, which requires destructive and complex processes, is primarily used to identify unknown 2DM specimens, hindering the subsequent use of characterized samples. Here, a nondestructive large-area 2D crystallographic analytical method through sticky-note-like van der Waals (vdW) assembling-disassembling is presented. By the vdW assembling of veiled polycrystalline graphene (PCG) with a single-atom-thick single-crystalline graphene filter (SCG-filter), detailed crystallographic information of each grain in PCGs is visualized through a 2D Raman signal scan, which relies on the interlayer twist angle. The scanned PCGs are seamlessly separated from the SCG-filter using vdW disassembling, preserving their original condition. The remaining SCG-filter is then reused for additional crystallographic scans of other PCGs. It is believed that the methods can pave the way for advances in the crystallographic analysis of single-atom-thick materials, offering huge implications for the applications of 2DMs.

3.
Sleep Med ; 100: 157-164, 2022 12.
Article in English | MEDLINE | ID: mdl-36063638

ABSTRACT

OBJECTIVE: Sleep disturbance is associated with negative effects to workers' health and productivity; hence, it is important to find which population of workers are associated with sleep disturbance. This study aimed to investigate the association between physical risk factors (vibration, noise, high, and low temperatures) and sleep disturbance in the Korean working population. METHODS: We analyzed data on 29,213 paid workers from the 5th Korean Working Conditions Survey. Individual and occupational characteristics, physical risk factors exposure, and sleep disturbance were collected using self-reported questionnaires. To assess the association between physical risk factors and sleep disturbance, the chi-square test and multivariable logistic regression models were conducted. All statistical analyses were performed in sex-based subgroups. RESULTS: We observed that all physical risk factors are associated with sleep disturbance. The adjusted odds ratios (95% confidence interval [CI]) of severe exposure to vibration, noise, high and low temperature were 1.69 (CI:1.47-1.94), 2.52 (CI:2.17-2.92), 3.09 (CI:2.69-3.56), and 1.96 (CI:1.68-2.28) in male workers and 2.27 (CI:1.89-2.72), 3.52 (CI:2.92-4.24), 3.30 (CI:2.81-3.87), and 2.87 (CI:2.44-3.38) in female workers, respectively. The prevalence of sleep disturbance increased with increased exposure to physical risk factors, indicating a dose-response relationship. CONCLUSIONS: Physical risk factors exposure in the workplace was associated with sleep disturbance of workers, indicating a dose-response relationship. Given the impact of sleep disturbance on workers' health and efficiency, it may be important to control exposure to physical risk factors in the working environment with regards to sleep conditions.


Subject(s)
Sleep Wake Disorders , Male , Female , Humans , Republic of Korea/epidemiology , Sleep Wake Disorders/epidemiology , Sleep Wake Disorders/etiology , Surveys and Questionnaires , Risk Factors , Sleep
4.
Materials (Basel) ; 15(14)2022 Jul 12.
Article in English | MEDLINE | ID: mdl-35888327

ABSTRACT

Under some clinical conditions, the preparation of crowns of limited marginal thickness is inevitable. In such situations, it is questionable whether the same ideal preparation criteria can be applied equally. Since there are only a small number of studies focusing on the fracture resistance with respect to the marginal thickness, there is a need for a study evaluating whether zirconia crowns of limited marginal thickness are clinically acceptable. The purpose of this study is to evaluate the fracture resistance of monolithic zirconia crowns of limited marginal thickness in the posterior area. Methods: Abutments and CAD/CAM zirconia crowns with a marginal thickness of 1.0 mm were set as the control group, while experimental groups A, B, and C possessed reduced marginal thicknesses of 0.8 mm, 0.6 mm, and 0.4 mm, respectively (n = 10 per group). Resin-based abutment dies and monolithic zirconia crowns were fabricated using the CAD/CAM technique, and a universal testing machine was used to measure the fracture load value. Fractured specimens were examined with a scanning electron microscope. The data were analyzed using a one-way ANOVA and Bonferroni post hoc test (p < 0.05). Results: The means and standard deviations of the fracture load values of the control group and the three experimental groups were as follows: control group (1.0 mm): 3090.91 ± 527.77 N; group A (0.8 mm): 2645.39 ± 329.21 N; group B (0.6 mm): 2256.85 ± 454.15 N; group C (0.4 mm): 1957.8 ± 522.14 N. Conclusions: The crowns fabricated with a CAD/CAM zirconia block with limited marginal thicknesses of 0.6 mm and 0.4 mm showed significantly lower fracture resistance values compared to those with the recommended margin thickness of 1.0 mm.

5.
Front Public Health ; 10: 802083, 2022.
Article in English | MEDLINE | ID: mdl-35558545

ABSTRACT

Background: Smoking negatively affects health, and previous studies argue that secondhand smoke (SHS) has a significantly negative health effect. We investigated whether SHS in the workplace influences workers' depression. Methods: Three years of data (2014, 2016, and 2018) from the Korean National Health and Nutrition Examination Survey were analyzed. Participants who were not current smokers were classified into the occupational SHS exposed and non-exposed groups. Multivariate logistic regression was performed to estimate odds ratios (ORs) and 95% confidence intervals (CIs) by adjusting various covariates. Stratified analysis with variables, such as year, sex, occupational classification, average working hours, was additionally performed. Results: The crude ORs of depression was 1.51 (95% CI: 1.27-1.80), and the fully adjusted OR with all the covariates was 1.57 (95% CI: 1.30-1.88). This indicated a significant relationship between occupational SHS and depression. The ORs increased every 2 years: 1.07 (95% CI: 0.79-1.44) in 2014, 1.88 (95% CI: 1.34-2.64) in 2016, and 2.07 (95% CI: 1.43-2.99) in year 2018. Stratification analysis also showed a significant association between SHS and depression among those in the prolonged work hours group and male employees, as well as blue- and white-collar workers. Conclusion: SHS in the workplace was significantly associated with workers' depression. Our study provides insights into the impact of exposure to SHS for workers and provides a basis for further research and policy-making in this field.


Subject(s)
Tobacco Smoke Pollution , Depression/epidemiology , Humans , Male , Nutrition Surveys , Republic of Korea/epidemiology , Tobacco Smoke Pollution/adverse effects , Workplace
6.
Diabet Med ; 39(6): e14837, 2022 06.
Article in English | MEDLINE | ID: mdl-35352388

ABSTRACT

AIM: Previous studies have focused on the association between ambient particulate matter and diabetes. However, the relationship between subacute exposure to occupational dust and diabetes has not been explored. We aimed to assess this relationship. METHODS: Men who worked in dust-related process factories between January 2013 and December 2017 were recruited from a Korea Health Worker Examination Common Data Model cohort. A history of physician-diagnosed diabetes, use of an anti-diabetic drug, or a fasting blood glucose level of ≥7 mmol/L were considered the criteria to diagnose diabetes. Multivariable time-dependent Cox analysis estimated hazard ratios (HRs) and 95% CIs for incident diabetes associated with exposure to occupational dust exposure; interactions with lifestyle factors were analysed. Sensitivity analyses used propensity score matching and landmark analysis. RESULTS: Among 5141 male participants (median follow-up duration, 3.85 years), 349 participants had diabetes. Occupational dust exposure was related to an increased risk of diabetes in the time-dependent Cox analysis (entire cohort: HR 1.66 [95% CI 1.25-2.19], matched cohort: HR 1.65 [95% CI 1.22-2.24]). The findings showed the same direction in the landmark analysis (HR 1.42 [95% CI 1.01-1.99]). CONCLUSIONS: A significant relationship exists between occupational dust exposure and increased risk of diabetes in male workers. Further studies should be conducted to confirm that occupational dust exposure is a possible risk factor for diabetes.


Subject(s)
Diabetes Mellitus , Occupational Diseases , Occupational Exposure , Cohort Studies , Diabetes Mellitus/epidemiology , Diabetes Mellitus/etiology , Dust/analysis , Female , Humans , Incidence , Male , Occupational Diseases/epidemiology , Occupational Diseases/etiology , Occupational Exposure/adverse effects , Retrospective Studies
7.
J Hypertens ; 40(3): 588-595, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34889865

ABSTRACT

OBJECTIVES: Previous studies mostly focused on the relationship between chronic environmental noise exposure and hypertension but the effects of subacute (under 4 years) exposure with severe (>85 dB) noise exposure on clinical level hypertension have not been explored. This study aimed to reveal the association between severe noise exposure and hypertension. METHODS: The severe noise exposure group was recruited from a Common Data Model conducted for the Korean Participants Health Examination from January 2014 to December 2017. The use of antihypertensive drug and/or blood pressure of at least 140/90 mmHg was defined as new onset clinical hypertension. A multivariate Cox proportional hazard model was implemented to estimate hazard ratios and 95% confidence intervals (CI) by adjusting covariates including demographic, lifestyle, and other chemical exposure factors. Time-dependent Cox analysis and Landmark analysis were further performed as a sensitivity analysis. RESULTS: During the 29 332 person-years follow-up with 12 412 participants of the entire cohort, new onset hypertension occurred in 1222 participants. The findings showed that severe noise exposure was associated with an increased risk of hypertension incidence in the entire cohort [final model hazard ratio 1.28 (95% CI 1.11-1.47)]. Other covariates did not attenuate the association after adjusting age and sex. Time-dependent Cox and Landmark analysis also showed significant results [hazard ratio 1.60 (95% CI 1.38-1.85) and hazard ratio 1.33 (95% CI 1.13-1.57)]. CONCLUSION: Severe noise with subacute exposure is significantly associated with hypertension development. Further studies should be implemented to clarify whether severe exposure to noise could be an important risk factor for hypertension.


Subject(s)
Hypertension , Antihypertensive Agents/therapeutic use , Blood Pressure , Cohort Studies , Humans , Hypertension/drug therapy , Hypertension/epidemiology , Hypertension/etiology , Risk Factors
8.
Front Public Health ; 9: 761279, 2021.
Article in English | MEDLINE | ID: mdl-34869175

ABSTRACT

Objectives: There is a need to determine the optimal limit of consecutive night shift work to reduce insomnia caused by the accumulation of sleep problems among night shift workers. This study aimed to investigate the prevalence of insomnia caused by consecutive night shifts and evaluate the night shift duration that worsens insomnia the most, using a large amount of medical examination data. Methods: Night shift profiles and baseline demographics data of three hospitals were collected from January 2015 to December 2017. For subjects who had been examined more than once at the same institution, information corresponding to the most recent date was used. Multivariate logistic regression was performed to estimate odds ratios (ORs) and 95% confidence intervals (CIs). Pooled ORs were calculated by using the results of the three institutions. Results: Of the 33,669 participants, 31.3% were female. The average age was 41.1 ± 11.1 years and the prevalence of insomnia was 38.7% (n = 13,025). After adjusting for potential confounders and compared to workers who reported not working in consecutive night shifts, odds of insomnia were greatest among workers reporting working three consecutive nights (OR 2.65, 95% CI 1.97-3.56) followed by those working two nights (OR 1.81, 95% CI 1.45-2.26), five nights (OR 1.78, 95% CI 1.56-2.03), and four nights (OR 1.68, 95% CI 1.55-1.82). Conclusion: Our study demonstrates a significant relationship between consecutive night shift and insomnia with multicenter examination data, using common data model. This study could be a basis for establishing policies and guidelines that improve night shift workers' health.


Subject(s)
Sleep Initiation and Maintenance Disorders , Adult , Cross-Sectional Studies , Female , Humans , Logistic Models , Male , Middle Aged , Prevalence , Sleep Initiation and Maintenance Disorders/epidemiology , Work Schedule Tolerance
9.
Diagnostics (Basel) ; 11(11)2021 Nov 16.
Article in English | MEDLINE | ID: mdl-34829470

ABSTRACT

Video capsule endoscopy (VCE) is an effective diagnostic modality for detecting small bowel lesions. However, the value of VCE for patients with chronic recurrent abdominal pain (CAP) of unknown etiology remains obscure. We retrospectively analyzed factors that could predict enteropathy based on the medical records of 65 patients with unexplained chronic recurrent abdominal pain (CAP) who were assessed using VCE between 2001 and 2021. We also conducted a systematic review and meta-analysis of the literature to validate our results. The positive findings of 27 (41.5%) of the 65 patients were mostly ulcerative lesions including stricture (n = 14, 60.9%) and erosion (n = 8, 29.7%). Multivariate analysis identified elevated ESR (OR, 1.06, 95% CI, 1.02-1.1, p = 0.004) as a significant risk factor for enteropathy predicted by VCE. Three eligible studies in the meta-analysis included 523 patients with CAP. Elevated C-reactive protein (CRP) (OR, 14.09; 95% CI, 2.81-70.60; p = 0.001) and erythrocyte sedimentation rate (ESR) (OR, 14.45; 95% CI, 0.92-227.33; p = 0.06) indicated VCE-positive findings in patients with unexplained abdominal pain. Elevated levels of the inflammatory markers ESR and CRP can thus predict positive VCE findings in patients with CAP.

10.
Article in English | MEDLINE | ID: mdl-34639639

ABSTRACT

This study aimed to investigate the association of support from colleagues and supervisors at the workplace on depressive and anxiety symptoms in wage earners from Korea. The data used in this study were from the fifth Korean Working Conditions Survey (KWCS) conducted in 2017 and analyzed using a multivariate logistic regression model. Furthermore, we measured the odds ratios (ORs) and 95% confidence intervals (CIs) of depressive and anxiety symptoms by stratifying covariates. The ORs of depressive and anxiety symptoms for the "non-support" group were higher than for the "support group" in terms of support from both colleagues and supervisors. The results of the stratified analysis of covariates, male, young, highly-educated, full-time, and white-collar groups were associated with the lack of support. Support from colleagues and supervisors was significantly associated with the Korean wage worker's mental health-depressive and anxiety symptoms, respectively. Further longitudinal and clinical studies on the relationship between mental health and support at the workplace are required.


Subject(s)
Depression , Workplace , Anxiety/epidemiology , Anxiety Disorders , Cross-Sectional Studies , Depression/epidemiology , Humans , Male , Social Support
11.
Article in English | MEDLINE | ID: mdl-34501978

ABSTRACT

The role of hazardous occupational noise exposure on the development of prediabetes is not well researched. We aimed to elucidate exposure to hazardous occupational noise as an independent risk factor for high fasting blood glucose (FBG). Participants exposed/non-exposed to occupational noise were recruited from the Common Data Model cohorts of 2013/2014 from two centers and were followed-up for 3 years. Multivariate time-dependent Cox proportional hazard models were used to estimate hazard ratios (HRs) and 95% confidence intervals (CIs) and were adjusted for various covariates. Pooled HRs were calculated. Among the 43,858 participants of this retrospective cohort study, 37.64% developed high FBG. The mean (standard deviation) age in the cohort was 40.91 (9.71) years. In the fully adjusted models, the HRs of high FBG in the two centers were 1.35 (95% CI: 1.24-1.48) and 1.22 (95% CI: 1.17-1.28), and the pooled HR was 1.28 (95% CI: 1.16-1.41). A Kaplan-Meier plot of high FBG incidence by occupational noise exposure showed significant results (p < 0.001). We found that occupational noise exposure is significantly associated with high FBG. Preventing exposure to hazardous noise in the work environment may help reduce the risk for prediabetes among workers.


Subject(s)
Noise, Occupational , Occupational Exposure , Adult , Blood Glucose , Fasting , Humans , Incidence , Retrospective Studies , Risk Factors
12.
Sci Adv ; 7(34)2021 Aug.
Article in English | MEDLINE | ID: mdl-34407946

ABSTRACT

An increase in the demand for completely foldable electronics has motivated efforts for the development of conducting polymer electrodes having extraordinary mechanical stability. However, weak physical adhesion at intrinsic heterojunctions has been a challenge in foldable electronics. This paper reports the completely foldable polymer thin-film transistors (PTFTs) and logic gate arrays. Homojunction-based PTFTs were fabricated by selectively doping p-type diketopyrrolopyrrole-based semiconducting polymer films with FeCl3 to form source/drain electrodes. The doping process caused a gradual work function change with depth, which promoted charge injection to semiconducting regions and provided a low contact resistance. In addition, the interfacial adhesion in the PTFTs was improved by interfacial cross-linking between adjacent component layers. The electrical performance of the resulting PTFTs was maintained without noticeable degradation even after extreme folding, suggesting that the proposed fabrication strategy can further be applied to various semiconducting polymers for the realization of foldable electronics.

13.
ACS Appl Mater Interfaces ; 13(22): 26330-26338, 2021 Jun 09.
Article in English | MEDLINE | ID: mdl-34037381

ABSTRACT

The hole density of individual copper sulfide nanocrystals (Cu2-xS NCs) is determined from the stoichiometric mismatch (x) between copper and sulfide atoms. Consequently, the electronic properties of the material vary over a range of x. To exploit Cu2-xS NCs in devices, assemblies of NCs are typically required. Herein, we investigate the influence of x, referred to as the stoichiometric doping effect, on the structural, optical, electrical, and thermoelectric properties of electronically coupled Cu2-xS NC assemblies. The doping process is done by immersing the solid NC assemblies into a solution containing a Cu(I) complex for different durations (0-10 min). As Cu+ gradually occupied the copper-deficient sites of Cu2-xS NCs, x could be controlled from 0.9 to less than 0.1. Consequently, the near-infrared (NIR) absorbance of Cu2-xS NC assemblies changes systematically with x. With increasing x, electrical conductivity increased and the Seebeck coefficient decreased systematically, leading to the maximal thermoelectric power factor from a film of Cu2-xS NCs at an optimal doping condition yielding x = 0.1. The physical characteristics of the Cu2-xS NC assemblies investigated herein will provide guidelines for exploiting this emerging class of nanocrystal system based on doping.

14.
Nat Commun ; 11(1): 2874, 2020 Jun 08.
Article in English | MEDLINE | ID: mdl-32513918

ABSTRACT

Establishing multi-colour patterning technology for colloidal quantum dots is critical for realising high-resolution displays based on the material. Here, we report a solution-based processing method to form patterns of quantum dots using a light-driven ligand crosslinker, ethane-1,2-diyl bis(4-azido-2,3,5,6-tetrafluorobenzoate). The crosslinker with two azide end groups can interlock the ligands of neighbouring quantum dots upon exposure to UV, yielding chemically robust quantum dot films. Exploiting the light-driven crosslinking process, different colour CdSe-based core-shell quantum dots can be photo-patterned; quantum dot patterns of red, green and blue primary colours with a sub-pixel size of 4 µm × 16 µm, corresponding to a resolution of >1400 pixels per inch, are demonstrated. The process is non-destructive, such that photoluminescence and electroluminescence characteristics of quantum dot films are preserved after crosslinking. We demonstrate that red crosslinked quantum dot light-emitting diodes exhibiting an external quantum efficiency as high as 14.6% can be obtained.

15.
Nat Commun ; 11(1): 1520, 2020 Mar 23.
Article in English | MEDLINE | ID: mdl-32251285

ABSTRACT

All-solution processing of large-area organic electronics requires multiple steps of patterning and stacking of various device components. Here, we report the fabrication of highly integrated arrays of polymer thin-film transistors and logic gates entirely through a series of solution processes. The fabrication is done using a three-dimensional crosslinker in tetrahedral geometry containing four photocrosslinkable azide moieties, referred to as 4Bx. 4Bx can be mixed with a variety of solution-processable electronic materials (polymer semiconductors, polymer insulators, and metal nanoparticles) and generate crosslinked network under exposure to UV. Fully crosslinked network film can be formed even at an unprecedentedly small loading, which enables preserving the inherent electrical and structural characteristics of host material. Because the crosslinked electronic component layers are strongly resistant to chemical solvents, micropatterning the layers at high resolution as well as stacking the layers on top of each other by series of solution processing steps is possible.

16.
Adv Mater ; 31(28): e1901400, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31063271

ABSTRACT

A universal method that enables utilization of conventional photolithography for processing a variety of polymer semiconductors is developed. The method relies on imparting chemical and physical orthogonality to a polymer film via formation of a semi-interpenetrating diphasic polymer network with a bridged polysilsesquioxane structure, which is termed an orthogonal polymer semiconductor gel. The synthesized gel films remain tolerant to various chemical and physical etching processes involved in photolithography, thereby facilitating fabrication of high-resolution patterns of polymer semiconductors. This method is utilized for fabricating tandem electronics, including pn-complementary inverter logic devices and pixelated polymer light-emitting diodes, which require deposition of multiple polymer semiconductors through solution processes. This novel and universal method is expected to significantly influence the development of advanced polymer electronics requiring sub-micrometer tandem structures.

17.
Antonie Van Leeuwenhoek ; 111(12): 2393-2402, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30022265

ABSTRACT

A Gram-stain negative, non-motile, rod-shaped bacterial strain, designated 2-56T, was isolated from water and characterized taxonomically using a polyphasic approach. Comparative 16S rRNA gene sequence analysis showed that strain 2-56T belongs to the family Flavobacteriaceae in the phylum Bacteroidetes and is closely related to Flavobacterium paronense KNUS1T (98.4%) and Flavobacterium collinsense 4-T-2T (96.7%). The G + C content of the genomic DNA of strain 2-56T was 33.4 mol%. The isolate contained MK-6 as the predominant respiratory quinone, and iso-C15:1 G (15.9%), iso-C15:0 (15.8%), iso-C17:0 3-OH (10.7%), and iso-C15:0 3-OH (9.6%) were the major fatty acids. The major polar lipids were phosphatidylethanolamine and an unidentified lipid. The phenotypic and chemotaxonomic data support the affiliation of strain 2-56T with the genus Flavobacterium. However, the DNA-DNA relatedness between the isolate and F. paronense and F. collinsense were 35.7 and 21.5%, respectively, clearly showing that strain 2-56T is not related to them at the species level. Strain 2-56T could be clearly differentiated from its close neighbours on the basis of its phenotypic, genotypic and chemotaxonomic features. Therefore, strain 2-56T represents a novel species of the genus Flavobacterium, for which the name Flavobacterium knui sp. nov. is proposed. The type strain is 2-56T (= KCTC 62061T = JCM 32247T).


Subject(s)
DNA, Bacterial/genetics , Flavobacterium/classification , Phylogeny , RNA, Ribosomal, 16S/genetics , Bacterial Typing Techniques , Base Composition , Fatty Acids/biosynthesis , Flavobacterium/chemistry , Flavobacterium/genetics , Flavobacterium/isolation & purification , Genotype , Phenotype , Phosphatidylethanolamines/biosynthesis , Republic of Korea , Water Microbiology
19.
J Korean Med Sci ; 31(8): 1190-6, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27478327

ABSTRACT

Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.


Subject(s)
Scrub Typhus/diagnosis , Antibodies, Bacterial/blood , Enzyme-Linked Immunosorbent Assay , Fluorescent Antibody Technique, Indirect , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Orientia tsutsugamushi/immunology , Reagent Kits, Diagnostic , Retrospective Studies , Scrub Typhus/microbiology , Sensitivity and Specificity
20.
J Clin Diagn Res ; 10(11): DC07-DC10, 2016 Nov.
Article in English | MEDLINE | ID: mdl-28050364

ABSTRACT

INTRODUCTION: Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. AIM: Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. MATERIALS AND METHODS: This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman's correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). RESULTS: Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. CONCLUSION: This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India.

SELECTION OF CITATIONS
SEARCH DETAIL
...