Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Heart Fail ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38825743

ABSTRACT

AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.

2.
Clin Cardiol ; 47(1): e24161, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37872853

ABSTRACT

BACKGROUND: In the Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See, patients with recent-onset atrial fibrillation (AF) were randomized to either early or delayed cardioversion. AIM: This prespecified sub-analysis aimed to evaluate heart rate during AF recurrences after an emergency department (ED) visit identified by an electrocardiogram (ECG)-based handheld device. METHODS: After the ED visit, included patients (n = 437) were asked to use an ECG-based handheld device to monitor for recurrences during the 4-week follow-up period. 335 patients used the handheld device and were included in this analysis. Recordings from the device were collected and assessed for heart rhythm and rate. Optimal rate control was defined as a target resting heart rate of <110 beats per minute (bpm). RESULTS: In 99 patients (29.6%, mean age 67 ± 10 years, 39.4% female, median 6 [3-12] AF recordings) a total of 314 AF recurrences (median 2 [1-3] per patient) were identified during follow-up. The average median resting heart rate at recurrence was 100 ± 21 bpm in the delayed vs 112 ± 25 bpm in the early cardioversion group (p = .011). Optimal rate control was seen in 68.4% [21.3%-100%] and 33.3% [0%-77.5%] of recordings (p = .01), respectively. Randomization group [coefficient -12.09 (-20.55 to -3.63, p = .006) for delayed vs. early cardioversion] and heart rate on index ECG [coefficient 0.46 (0.29-0.63, p < .001) per bpm increase] were identified on multivariable analysis as factors associated with lower median heart rate during AF recurrences. CONCLUSION: A delayed cardioversion strategy translated into a favorable heart rate profile during AF recurrences.


Subject(s)
Atrial Fibrillation , Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Electric Countershock , Electrocardiography , Heart Rate , Recurrence , Randomized Controlled Trials as Topic
3.
Heart ; 109(1): 26-33, 2022 12 13.
Article in English | MEDLINE | ID: mdl-36322782

ABSTRACT

OBJECTIVE: The Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See trial compared early to delayed cardioversion for patients with recent-onset symptomatic atrial fibrillation (AF). This study aims to evaluate the adherence to a 4-week mobile health (mHealth) prescription to detect AF recurrences after an emergency department visit. METHODS: After the emergency department visit, the 437 included patients, irrespective of randomisation arm (early or delayed cardioversion), were asked to record heart rate and rhythm for 1 min three times daily and in case of symptoms by an electrocardiography-based handheld device for 4 weeks (if available). Adherence was appraised as number of performed measurements per number of recordings asked from the patient and was evaluated for longitudinal adherence consistency. All patients who used the handheld device were included in this subanalysis. RESULTS: 335 patients (58% males; median age 67 (IQR 11) years) were included. The median overall adherence of all patients was 83.3% (IQR 29.9%). The median number of monitoring days was 27 out of 27 (IQR 5), whereas the median number of full monitoring days was 16 out of 27 (IQR 14). Higher age and a previous paroxysm of AF were identified as multivariable adjusted factors associated with adherence. CONCLUSIONS: In this randomised trial, a 4-week mHealth prescription to monitor for AF recurrences after an emergency department visit for recent-onset AF was feasible with 85.7% of patients consistently using the device with at least one measurement per day. Older patients were more adherent. TRIAL REGISTRATION NUMBER: NCT02248753.


Subject(s)
Atrial Fibrillation , Telemedicine , Male , Humans , Aged , Female , Atrial Fibrillation/therapy , Atrial Fibrillation/drug therapy , Anti-Arrhythmia Agents/therapeutic use , Heart Rate , Electric Countershock , Recurrence
4.
Ann Noninvasive Electrocardiol ; 25(3): e12722, 2020 05.
Article in English | MEDLINE | ID: mdl-31707764

ABSTRACT

BACKGROUND: In the prehospital triage of patients presenting with symptoms suggestive of acute myocardial ischemia, reliable myocardial ischemia detection in the electrocardiogram (ECG) is pivotal. Due to large interindividual variability and overlap between ischemic and nonischemic ECG-patterns, incorporation of a previous elective (reference) ECG may improve accuracy. The aim of the current study was to explore the potential value of serial ECG analysis using subtraction electrocardiography. METHODS: SUBTRACT is a multicenter retrospective observational study, including patients who were prehospitally evaluated for acute myocardial ischemia. For each patient, an elective previously recorded reference ECG was subtracted from the ambulance ECG. Patients were classified as myocardial ischemia cases or controls, based on the in-hospital diagnosis. The diagnostic performance of subtraction electrocardiography was tested using logistic regression of 28 variables describing the differences between the reference and ambulance ECGs. The Uni-G ECG Analysis Program was used for state-of-the-art single-ECG interpretation of the ambulance ECG. RESULTS: In 1,229 patients, the mean area-under-the-curve of subtraction electrocardiography was 0.80 (95%CI: 0.77-0.82). The performance of our new method was comparable to single-ECG analysis using the Uni-G algorithm: sensitivities were 66% versus 67% (p-value > .05), respectively; specificities were 80% versus 81% (p-value > .05), respectively. CONCLUSIONS: In our initial exploration, the diagnostic performance of subtraction electrocardiography for the detection of acute myocardial ischemia proved equal to that of state-of-the-art automated single-ECG analysis by the Uni-G algorithm. Possibly, refinement of both algorithms, or even integration of the two, could surpass current electrocardiographic myocardial ischemia detection.


Subject(s)
Electrocardiography/methods , Myocardial Ischemia/diagnosis , Triage/methods , Adolescent , Adult , Aged , Aged, 80 and over , Emergency Medical Services , Female , Humans , Male , Middle Aged , Myocardial Ischemia/physiopathology , Reproducibility of Results , Retrospective Studies , Young Adult
6.
Heart Rhythm ; 3(10): 1164-71, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17018345

ABSTRACT

BACKGROUND: Early recurrences within 10 minutes after termination of an atrial tachyarrhythmia, such as atrial tachycardia (AT), atrial flutter, or atrial fibrillation (AF) episodes, account for a large part of paroxysmal AT/AF episodes. It is unclear whether these arrhythmias can be suppressed by overdrive pacing. OBJECTIVE: We set out to prove that overdrive pacing is effective in preventing early recurrences of AT/AF. METHODS: This AT500 (DDDRP device, Bakken Research Center Medtronic, Maastricht, The Netherlands) post-mode switch overdrive pacing (PMOP) study is a randomized controlled trial designed to test the efficacy of overdrive pacing on the suppression of early recurring AT/AF episodes. With the PMOP feature, overdrive pacing is activated 12 ventricular beats after device-confirmed termination of an AT/AF episode with a programmed duration and rate. If at least four episodes of 1 minute in duration occurred within the run-in period of 1 month, patients were randomized to one of the three settings (PMOP off and PMOP 10 minutes at 90 bpm or 120 bpm) for 2 months. At 2 and 4 months, patients were crossed over to another arm. At 6 months, all patients were programmed with PMOP on at 90 bpm for 30 minutes. RESULTS: We enrolled 122 and randomized 50 patients. Sixty percent of all stored AT/AF episodes occurred within 10 minutes after a previous episode; 31% occurred after device-determined termination and before the device reached the overdrive rate (17-27 ventricular beats after termination), and 29% of the episodes occurred while the device was pacing at the programmed overdrive rate. Thirty-seven percent of the average percentage of episodes during the overdrive period was prevented by the randomized settings of PMOP 90 bpm/10 min (P = .01, paired t-test, n = 39) and 120 bpm/10 min (P = .03, n = 35). In addition, for the nonrandomized setting of PMOP 90 bpm/30 min, the average number of episodes during the overdrive period was significantly smaller than the percentage of episodes occurring during the corresponding off period of 30 minutes (P = .05, n = 33). No significant differences in burden and episodes were found between the PMOP settings and the corresponding off periods. CONCLUSIONS: This is the first randomized controlled clinical trial to prove that overdrive pacing is effective in preventing early recurrences of AT/AF. However, shortcomings of the PMOP algorithm, such as late activation, need further improvement.


Subject(s)
Algorithms , Cardiac Pacing, Artificial/methods , Tachycardia, Ectopic Atrial/therapy , Aged , Aged, 80 and over , Follow-Up Studies , Heart Rate/physiology , Humans , Middle Aged , Prospective Studies , Quality of Life , Secondary Prevention , Single-Blind Method , Tachycardia, Ectopic Atrial/physiopathology , Tachycardia, Ectopic Atrial/psychology , Treatment Outcome
7.
Heart Rhythm ; 2(3): 223-30, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15851308

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the hypothesis that presumed reversion of electrical remodeling after cardioversion of atrial fibrillation (AF) restores the efficacy of flecainide. BACKGROUND: Flecainide loses its efficacy to cardiovert when AF has been present for more than 24 hours. Most probably, the loss is caused by atrial electrical remodeling. Studies suggest electrical remodeling is completely reversible within 4 days after restoration of sinus rhythm (SR). METHODS: One hundred eighty-one patients with persistent AF (median duration 3 months) were included in this prospective study. After failure of pharmacologic cardioversion by flecainide 2 mg/kg IV (maximum 150 mg in 10 minutes) and subsequent successful electrical cardioversion, we performed intense transtelephonic rhythm monitoring three times daily for 1 month. In case of AF recurrence, a second cardioversion by flecainide was attempted as soon as possible. RESULTS: AF recurred in 123 patients (68%). Successful cardioversion by flecainide occurred only when SR had been maintained for more than 4 days (7/51 patients [14%]). Failure to cardiovert was associated with a prolonged duration of the recurrent AF episode and concurrent digoxin use. Multivariate logistic regression confirmed that successful cardioversion was determined by digoxin use (odds ratio [OR] 0.093, P = .047) and by the interaction between the duration of SR and the (inverse) duration of recurrent AF (OR 6.499, P < .001). When flecainide was administered within 10 hours after AF onset and the duration of SR was greater than 4 days, the success rate was 58%. CONCLUSIONS: Flecainide recovers its antiarrhythmic action after cardioversion of AF. However, successful pharmacologic cardioversion occurs only after SR has lasted at least 4 days and is expected only for recurrences having duration of a few hours. Immediate pharmacologic cardioversion of AF recurrence may be a worthwhile strategy for management of persistent AF.


Subject(s)
Anti-Arrhythmia Agents/pharmacology , Atrial Fibrillation/drug therapy , Electric Countershock , Flecainide/pharmacology , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Female , Humans , Logistic Models , Male , Middle Aged , Multivariate Analysis , Prognosis , Recurrence , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...