Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 455
Filter
1.
Article in English | MEDLINE | ID: mdl-38692444

ABSTRACT

BACKGROUND: Patient-reported outcome (PRO) measures of distinct concepts are often put together into patient profile assessments. When brief, profile assessments can decrease respondent burden and increase measure completion rates. In this report, we describe the creation of 5 self-reported 4-item short forms and the Mechanical Circulatory Support: Measures of Adjustment and Quality of Life (MCS A-QOL) 20-item profile to assess PROs specific to adjustment and health-related quality of life (HRQOL) among patients who undergo left ventricular assist device (LVAD) implantation. METHODS: Using a cross-sectional sample of patients (n = 620) who underwent LVAD implantation at 12 U.S. sites or participated in the MyLVAD.com support group, we created 5 4-item short forms: Satisfaction with Treatment, ventricular assist device (VAD) Team Communication, Being Bothered by VAD Self-care and Limitations, Self-efficacy Regarding VAD self-care, and Stigma, which we combined into a 20-item profile. Analyses included intercorrelations among measures, Cronbach's alpha (i.e., internal consistency reliability)/score-level-specific reliability, and construct validity. RESULTS: The 620 patients were mean age = 57 years, 78% male, 70% White, and 56% on destination therapy LVADs. Intercorrelations among the 5 4-item measures were low to moderate (≤0.50), indicating they are associated yet largely distinct, and correlations with calibrated measures and 6-item short forms were ≥0.76, indicating their ability to reflect full-item bank scores. Internal consistency reliability for the 5 4-item short forms ranged from acceptable (≥0.70) to good (≥0.80). Construct validity was demonstrated for these measures. CONCLUSIONS: Our 5 4-item short forms are reliable and valid and may be used individually or together as a 20-item profile to assess adjustment and HRQOL in patients who undergo LVAD implantation.

2.
Article in English | MEDLINE | ID: mdl-38762215

ABSTRACT

BACKGROUND: The quality-adjusted life year (QALY) measures disease burden and treatment, combining overall survival and health-related quality of life (HRQOL). We estimated QALYs in three groups of older patients (60-80 years) with heart failure (HF) who underwent heart transplantation (HT, with pre-transplant mechanical circulatory support [HT MCS] or HT without pre-transplant MCS [HT Non-MCS]) or long-term MCS (destination therapy). We also identified factors associated with gains in QALYs through 24 months follow-up. METHODS: Of 393 eligible patients enrolled (10/1/15-12/31/18) at 13 U.S. sites, 161 underwent HT (n=68 HT MCS, n=93 HT Non-MCS) and 144 underwent long-term MCS. Survival and HRQOL data were collected through 24 months. QALY health utilities were based on patient self-report of EQ-5D-3L dimensions. Mean-restricted QALYs were compared among groups using generalized linear models. RESULTS: For the entire cohort, mean age in years closest to surgery was 67 (standard deviation, SD: 4.7), 78% were male, and 83% were White. By 18 months post-surgery, sustained significant differences in adjusted average+SD QALYs emerged across groups, with the HT Non-MCS group having the highest average QALYs (24-month window: HT Non-MCS=22.58+1.1, HT MCS=19.53+1.33, Long-term MCS=19.49+1.3, p=0.003). At 24 months post-operatively, a lower gain in QALYs was associated with HT MCS, long-term MCS, a lower pre-operative LVEF, NYHA class III or IV before surgery, and an ischemic or other etiology of HF. CONCLUSIONS: Determination of QALYs may provide important information for policy makers and clinicians to consider regarding benefits of HT and long-term MCS as treatment options for older patients with HF.

3.
Ann Thorac Surg ; 2024 May 25.
Article in English | MEDLINE | ID: mdl-38802036

ABSTRACT

BACKGROUND: PEDIMACS provides detailed understanding on pediatric patients supported with ventricular assist devices (VADs). We sought to identify important variables affecting the incidence of stroke in pediatric VADs. METHODS: Between 2012-2022, 1,463 devices in 1,219 patients were reported to PEDIMACS s from 40 Centers in patients<19yrs at their first VAD implantation. Multiphase parametric hazard modeling was used to identify risk factors for stroke among all device types. RESULTS: Of the 1,219 patients, the most common devices were implantable continuous (472 [39%]), followed by paracorporeal pulsatile (342 [28%]), paracorporeal continuous (327 [27%]). Overall freedom from stroke at 6 months was higher in the recent era (2012-2016; 80.2% [77.1%-82.9%] vs 2017-2023; 87.9% [86.2%-89.4%], p=0.009). Implantable Continuous had the highest freedom from stroke at 3 (92.7% [91.1%-93.9%]) and 6 (91.1% [89.3%-92.6%]) months, followed by Paracorporeal Pulsatile (87.0% [84.8%-88.9%] and 82.8% [79.8%-85.5%]), and Paracoporeal Continuous (76.0% [71.8%-79.5%] and 69.5% [63.4%-74.8%]). Parametric modeling identified risk factors for stoke early post implant and later. Overall, and particularly for Paracorporal Pulsatile devices, early stroke risk has decreased in the most recent era (HR 5.01). Among Implantable Continuous devices, cardiogenic shock was the major risk factor. For patients<10kg, early hazard was only seen in previous era. For congentail patients, early hazard was seen in non-implantable device use and use of ECMO. CONCLUSIONS: Overall stroke rate has decreased from 20% to 15% at 6 months, with particular improvement among PP devices. Risk factor analyses offer insights for identification of higher stroke risk subsets and further management refinements.

4.
Pediatr Transplant ; 28(2): e14720, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38433570

ABSTRACT

BACKGROUND: There are conflicting data regarding the relationship between center volume and outcomes in pediatric heart transplantation. Previous studies have not fully accounted for differences in case mix, particularly in high-risk congenital heart disease (CHD) groups. We aimed to evaluate the relationship between center volume and outcomes using the Pediatric Heart Transplant Society (PHTS) Registry and explore how case mix may affect outcomes. METHODS: A retrospective cohort study of all pediatric patients in the PHTS Registry who received a heart transplant from 2009 to 2018 was performed. Centers were divided into 5 groups based on average yearly transplant volume. The primary outcome was time to death or graft loss and outcomes were compared using Kaplan-Meier analysis. RESULTS: There were 4583 cases among 55 centers included. There was no difference in time to death or graft loss by center volume in the entire cohort (p = .75), in patients with CHD (p = .79) or in patients with cardiomyopathy (p = .23). There was also no difference in time to death or graft loss by center size in patients undergoing transplant after Norwood, Glenn or Fontan (log rank p = .17, p = .31, and p = .10 respectively). There was a statistically significant difference in outcomes by center size in the positive crossmatch group (p < .0001), though no discernible pattern related to high or low center volume. CONCLUSIONS: Outcomes are similar among transplant centers of all sizes, including for high-risk patient groups with CHD. Future work is needed to understand how patient-specific risk factors may vary among centers of various sizes and whether this influences patient outcomes.


Subject(s)
Heart Transplantation , Transplants , Humans , Child , Retrospective Studies , Kaplan-Meier Estimate , Registries
5.
Article in English | MEDLINE | ID: mdl-38460619

ABSTRACT

BACKGROUND: Impacts of ischemic time (IT) on pediatric heart transplant outcomes are multifactorial. We aimed to analyze the effect of prolonged IT on graft loss after pediatric heart transplantation. We hypothesized that graft survival with prolonged IT has improved across eras. METHODS: Patients <18 years old in the Pediatric Heart Transplant Society database were included (N=6,765) and stratified by diagnosis and era (1993-2004, 2005-2009, and 2010-2019). Severe graft failure (SGF) was defined as death, retransplant, or need for mechanical circulatory support in the first 7 days post-transplant. Descriptive statistical methods were used to compare differences between patient characteristics and IT. Kaplan-Meier survival analysis compared freedom from graft loss, rejection, and infection. Multivariable analysis was performed for graft loss and SGF (hazard and logistic regression modeling, respectively). RESULTS: Diagnoses were cardiomyopathy (N = 3,246) and congenital heart disease (CHD; N = 3,305). CHD were younger, more likely to have an IT ≥4.5 hours, and more likely to require extracorporeal membrane oxygenation or mechanical ventilation at transplant (all p < 0.001). Median IT was 3.6 hours (interquartile range 2.98-4.31; range 0-10.5). IT was associated with early graft loss (HR 1.012, 95% CI 1.005-1.019), but not when analyzed only in the most recent era. IT was associated with SGF (OR 1.016 95%CI 1.003-1.030). CONCLUSIONS: Donor IT was independently associated with an increased risk of graft loss, albeit with a small effect relative to other risk factors. Graft survival with prolonged IT has improved in the most recent era but the risk of SGF persists.

7.
Cardiol Young ; 34(2): 233-237, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38258454

ABSTRACT

In the 1980s, heart transplantation was the first successful treatment for infants born with hypoplastic left heart syndrome. Infants who have required heart transplantation benefit from immunologic "advantages," including long-term survival free from cardiac allograft vasculopathy. Currently ∼ 90% of children undergoing a heart transplant are reaching their first-year anniversary and the clinical practices of paediatric heart transplantation have dramatically improved. These successes are largely attributed to research sponsored by the Pediatric Heart Transplant Study Group, the International Society of Heart and Lung Transplantation and, more recently, the Non-profits Enduring Hearts and Additional Ventures. Despite these successes, the field is challenged to increase progress to achieve long-term survival into adulthood. The wait-list mortality, especially among infants, is unacceptably high often leading to palliative measures that can increase post-transplant mortality. Cardiac allograft vasculopathy remains a major cause for progressive graft loss of function and sudden death. The relative tolerance seen in immature recipients has not been translated to modifying older recipients' post-transplant outcomes. The modifiable cause(s) for the increased risks of transplantation in children of different ethnicities and races require definition. Addressing these challenges faces the reality that for-profit research favours funding adult recipients, with ∼ 10-fold greater numbers, and their more modest longevity goals. Advocacy for funding "incentives" such as the Orphan Drug rules in the United States and upholding principles of equity and inclusion are critical to addressing the challenges of paediatric heart transplant recipients worldwide.


Subject(s)
Heart Diseases , Heart Transplantation , Hypoplastic Left Heart Syndrome , Infant , Adult , Female , Humans , Child , United States/epidemiology , Transplant Recipients , Survival Rate , Graft Rejection/prevention & control , Retrospective Studies
8.
Ann Thorac Surg ; 117(1): 33-44, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37944655

ABSTRACT

The 14th Annual Report from The Society of Thoracic Surgeons (STS) Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs) describes outcomes of 27,493 patients with a continuous-flow left ventricular assist device (LVAD) from the past decade (2013-2022). In 2022, 2517 primary LVADs were implanted, of which 2512 (99.8%) were fully magnetically levitated (Mag-Lev) devices. This shift to nearly exclusive use of a Mag-Lev device led us to examine its outcomes compared with contemporary (2018-2022) and historical (2013-2017) non-Mag-Lev cohorts. Patients supported by a Mag-Lev device (n = 10,920) had a higher 1- and 5-year survival of 86% (vs 79% and 81%, P < .0001) and 64% (vs 44% and 44%, P < .0001), respectively, than those receiving non-Mag-Lev devices during the contemporary and historical eras. Over 5 years, freedom from gastrointestinal bleeding (72% vs 60%, P < .0001), stroke (87% vs 67%, P < .0001), and device malfunction/pump thrombus (83% vs 54%, P < .0001), but not device-related infection (61% vs 64%, P = .93), was higher with Mag-Lev devices compared with non-Mag-Lev support during the contemporary era. In this large primacy cohort of real-world patients with advanced heart failure, this report underscores marked improvements in short- and intermediate-term survival and reduction of adverse events with a contemporary Mag-Lev LVAD.


Subject(s)
Heart Failure , Heart-Assist Devices , Thrombosis , Humans , Heart Failure/surgery , Heart Failure/etiology , Heart-Assist Devices/adverse effects , Societies, Medical , Thrombosis/etiology , Registries , Treatment Outcome
10.
JACC Heart Fail ; 12(2): 380-391, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37676215

ABSTRACT

BACKGROUND: To date, no studies have identified an optimal metric to match donor-recipient (D-R) pairs in pediatric heart transplantation (HT). OBJECTIVES: This study sought to identify size mismatch metrics that predicted graft survival post-HT. METHODS: D-R pairs undergoing HT in Pediatric Heart Transplant Society database from 1993 to 2021 were included. Effects of size mismatch by height, weight, body mass index, body surface area, predicted heart mass, and total cardiac volume (TCV) on 1- and 5-year graft survival and morbidity outcomes (rejection and cardiac allograft vasculopathy) were evaluated. Cox models with stepwise selection identified size metrics that independently predicted graft survival. RESULTS: Of 7,715 D-R pairs, 36.0% were well matched (D-R ratio: -20% to +20%) by weight, 39.0% by predicted heart mass, 50.0% by body surface area, 57.0% by body mass index, 71.0% by height, and 93.0% by TCV. Of all size metrics, only D-R mismatch by height and TCV predicted graft survival at 1 and 5 years. Effects of D-R size mismatch on graft survival were nonlinear. At both 1 and 5 years post-HT, D-R undersizing and oversizing by height led to increased graft loss, with graft loss observed more frequently with undersizing. Moderately undersized donors by height (D-R ratio: <-30%) frequently experienced rejection post-HT (P < 0.001). Assessing D-R size matching by TCV, minimal donor undersizing was protective, while oversizing up to 25% was not associated with increased graft loss. CONCLUSIONS: In pediatric HT, D-R appear most optimally matched using TCV. Only D-R size mismatch by TCV and height independently predicts graft survival. Standardizing size matching across centers may reduce donor discard.


Subject(s)
Heart Failure , Heart Transplantation , Tissue and Organ Procurement , Humans , Child , Retrospective Studies , Tissue Donors , Graft Survival
11.
J Heart Lung Transplant ; 43(1): 36-50, 2024 01.
Article in English | MEDLINE | ID: mdl-37591454

ABSTRACT

BACKGROUND: Generic and heart failure-specific measures do not capture unique aspects of living with a ventricular assist device (VAD). Using state-of-the-science psychometric measurement methods, we developed a measurement system to assess post-ventricular assist device adjustment and health-related quality of life (HRQOL). METHODS: Patients were recruited from 10/26/16-2/29/20 from 12 U.S. VAD programs. We created a dataset of participants (n = 620) enrolled before left (L)VAD implantation, with data at 3- or 6- months post-implantation (group1 [n = 154]), and participants enrolled after LVAD implantation, with data at one timepoint (group 2 [n = 466]). We constructed 5 item banks: 3 modified from existing measures and 2 new measures. Analyses included item response theory (IRT) modeling, differential item functioning tests for systematic measurement bias, and indicators of reliability and validity. RESULTS: Of 620 participants, 56% (n = 345) were implanted as destination therapy, 51% (n = 316) were <12 months post-implantation, mean age = 57.3 years, 78% (n = 485) male, 70% (n = 433) White, 58% (n = 353) married/partnered, and 58% (n = 357) with >high school education. We developed 5 new VAD item banks/measures: 6-item VAD Team Communication; 12-item Self-efficacy Regarding VAD Self-care; 11-item Being Bothered by VAD Self-care and Limitations; 7-item Satisfaction with Treatment; and 11-item Stigma. Cronbach's alpha reliability ranged from good (≥0.80) to excellent (≥0.90) for item banks/measures. All measures, except VAD Team Communication, demonstrated at least moderate correlations (≥0.30) with construct validity indicators. CONCLUSIONS: These measures meet IRT modeling assumptions and requirements; scores demonstrate reliability and validity. Use of these measures may assist VAD clinicians to inform patients about VADs as a treatment option and guide post-VAD interventions.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Male , Middle Aged , Quality of Life , Reproducibility of Results , Heart Failure/surgery , Patient Reported Outcome Measures
12.
Pediatr Transplant ; 28(1): e14615, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37811686

ABSTRACT

BACKGROUND: The Pediatric Heart Transplant Society (PHTS) Registry was founded 30 years ago as a collaborative effort among like-minded providers of this novel life-saving technique for children with end-stage heart failure. In the intervening decades, the data from the Registry have provided invaluable knowledge to the field of pediatric heart transplantation. This report of the PHTS Registry provides a comprehensive look at the data, highlighting both the longevity of the registry and one unique aspect of the PHTS registry, allowing for exploration into children with single ventricle anatomy. METHODS: The PHTS database was queried from January 1, 1993 to December 31, 2019 to include pediatric (age < 18 years) patients listed for HT. For our analysis, we primarily analyzed patients by era. The early era was defined as children listed for HT from January 1, 1993 to December 31, 2004; middle era January 1, 2005 to December 31, 2009; and recent era January 1, 2010 to December 31, 2019. Outcomes after listing and transplant, including mortality and morbidities, are presented as unadjusted for risk, but compared across eras. RESULTS: Since 1993, 11 995 children were listed for heart transplant and entered into the PHTS Registry with 9755 listed during the study period. The majority of listings occurred within the most recent era. Waitlist survival improved over the decades as did posttransplant survival. Other notable changes over time include fewer patients experiencing allograft rejection or infection after transplant. Waitlist and posttransplant survival have changed dramatically in patients with single ventricle physiology and significantly differ by stage of single ventricle palliation. SUMMARY: Key points from this PHTS Registry summary and focus on patients with single ventricle congenital heart disease in particular, include the changing landscape of candidates and recipients awaiting heart transplant. There is clear improvement in waitlist and transplant outcomes for children with both cardiomyopathy and congenital heart disease alike.


Subject(s)
Cardiomyopathies , Heart Defects, Congenital , Heart Transplantation , Univentricular Heart , Child , Humans , Adolescent , Routinely Collected Health Data , Heart Defects, Congenital/surgery , Registries , Waiting Lists , Retrospective Studies
13.
J Card Fail ; 30(4): 552-561, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37898382

ABSTRACT

BACKGROUND: Left ventricular assist devices (LVADs) have been implanted as bridge to transplantation (BTT), bridge to candidacy (BTC) or destination therapy (DT) on the basis of relative and absolute contraindications to transplantation. Multiple factors may lead to changes in the strategy of support after LVAD implantation. METHODS: Based on INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) 2012-2020 data, 11,262 patients survived to 3 months on continuous-flow LVADs with intent of BTT or DT. Preimplant characteristics and early events post-LVAD were analyzed in relation to changes in BTT or DT strategy during the next 12 months. RESULTS: Among 3216 BTT patients at 3 months, later transplant delisting or death without transplant occurred in 536 (16.7%) and was more common with age, profiles 1-2, renal dysfunction, and independently for prior cardiac surgery (HR 1.25, 95% CI 1.04-1.51; P = 0.02). Post-LVAD events of infections, gastrointestinal bleeding, stroke, and right heart failure as defined by inotropic therapy, predicted delisting and death, as did in-hospital location at 3 months (HR 1.67, 95% CI 1.20-2.33; P = 0.0024). Of 8046 patients surviving to 3 months with the intent of destination therapy, 750 (9.3%) subsequently underwent listing or transplantation, often with initial histories of acute HF (HR 1.70, 95% CI 1.27-2.27; P = 0.0012) or malnutrition-cachexia (1.73, 95% CI 1.14-2.63; P = 0.0099). Multiple gastrointestinal bleeding events (≥ 4) with LVAD increased transition from BTT to DT (HR 4.22, 95% CI 1.46-12.275; P = 0.0078) but also from DT to BTT (HR 5.17, 95% CI 1.92-13.9; P = 0.0011). CONCLUSIONS: Implant strategies change over time in relation to preimplant characteristics and adverse events post implant. Preimplant recognition of factors predicting later change in implant strategy will refine initial triage, whereas further reduction of post-LVAD complications will expand options, including eventual consideration of heart transplantation.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Humans , Heart Failure/epidemiology , Heart Failure/surgery , Heart Transplantation/adverse effects , Heart-Assist Devices/adverse effects , Gastrointestinal Hemorrhage/etiology , Time Factors , Treatment Outcome , Retrospective Studies
14.
World J Pediatr Congenit Heart Surg ; 15(1): 11-18, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37899596

ABSTRACT

OBJECTIVE: Primary repair in the first six months of life is routine for tetralogy of Fallot, complete atrioventricular septal defect, and ventricular septal defect in high-income countries. The objective of this analysis was to understand the utilization and outcomes of palliative and reparative procedures in high versus middle-income countries. METHODS: The World Database of Pediatric and Congenital Heart Surgery identified patients who underwent surgery for: tetralogy of Fallot, complete atrioventricular septal defect, and ventricular septal defect. Patients were categorized as undergoing primary repair, repair after prior palliation, or palliation only. Country economic status was categorized as lower middle, upper middle, and high, defined by the World Bank. Multiple logistic regression models were utilized to identify independent predictors of hospital mortality. RESULTS: Economic categories included high (n = 571, 5.3%), upper middle (n = 5,342, 50%), and lower middle (n = 4,793, 49.7%). The proportion of patients and median age with primary repair were: tetralogy of Fallot, 88.6%, 17.7 months; complete atrioventricular septal defect, 83.4%, 7.7 months; and ventricular septal defect, 97.1%, ten months. Age at repair was younger in high income countries (P < .0001). Overall mortality after repair was lowest in high income countries. Risk factors for hospital mortality included prematurity, genetic syndromes, and urgent or emergent operations (all P < .05). CONCLUSIONS: Primary repair was selected in >90% of patients, but definitive repair was delayed in lower and upper middle income countries compared with high-income countries. Repair after prior palliation versus primary repair was not a risk factor for hospital mortality. Initial palliation continues to have a small but important role in the management of these three specific congenital heart defects.


Subject(s)
Heart Septal Defects, Ventricular , Heart Septal Defects , Tetralogy of Fallot , Humans , Child , Infant , Tetralogy of Fallot/surgery , Economic Status , Heart Septal Defects/surgery , Heart Septal Defects, Ventricular/surgery , Treatment Outcome , Retrospective Studies
15.
Ann Thorac Surg ; 117(4): 690-703, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38123046

ABSTRACT

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), supported by The Society of Thoracic Surgeons, provides detailed information on pediatric patients supported with ventricular assist devices (VADs). METHODS: From September 19, 2012, to December 31, 2022, 1463 devices in 1219 patients aged <19 years were reported to the registry from 40 North American hospitals. RESULTS: Cardiomyopathy remains the most common underlying etiology (59%), followed by congenital heart disease (26%) and myocarditis (8%). Implantable continuous devices were most common (39%) type, followed by paracorporeal pulsatile (28%) and paracorporeal continuous (27%) devices. At 6 months after VAD implantation, a favorable outcome (transplant, recovery, or alive on device) was achieved in 85% of patients, which was greatest among those on implantable continuous VADs (92%) and least for paracorporeal continuous VADs (68%), although the patient population supported on these devices is different. CONCLUSIONS: This Seventh Pedimacs Report demonstrates the continued importance of VADs in the treatment of children. With the complexity of cardiac physiologies and sizes of patients, multiple types of devices are used, including paracorporeal continuous, paracorporeal pulsatile, and implantable continuous devices. The preoperative risk factors and differences in patient populations may account for some of the differences in survival observed among these devices. This report, along with other collaborative work, continues to advance the care of this challenging and vulnerable population.


Subject(s)
Heart Defects, Congenital , Heart Failure , Heart Transplantation , Heart-Assist Devices , Surgeons , Child , Humans , Heart Failure/surgery , Treatment Outcome , Registries , Retrospective Studies
16.
Article in English | MEDLINE | ID: mdl-38065240

ABSTRACT

BACKGROUND: Cardiac allograft vasculopathy (CAV) is a leading cause of graft failure in pediatric heart transplant recipients (HTRs). Early statin use has been shown to reduce CAV incidence and all-cause mortality in adult HTRs. We sought to evaluate the contemporary prevalence and trends of statin use in pediatric HTRs and the association between statin use with CAV development and graft failure. METHODS: Patients aged <17 years at the time of primary heart transplant who survived to ≥3 years without CAV were identified from the Pediatric Heart Transplant Society database (2001-2018). Statin use in the first 3 years posttransplant was defined as consecutive, intermediate, or absent. Kaplan-Meier survival, multivariable modeling, and propensity score-matched analyses evaluated associations between statin use and CAV incidence and graft survival, with subanalyses performed on subjects aged ≥10 years at transplant. RESULTS: Among 3,485 (of which 1,086 aged ≥10 years) HTRs, 584 (17%) received consecutive statin therapy, 647 (19%) received intermediate use, and 2,254 (65%) received no statin therapy. Statin use varied widely between sites, with increasing use in the ≥10-year-old cohort over time. By multivariate analysis, statin use was not associated with graft loss. Consecutive statin use was also not associated with graft survival or freedom from CAV development when compared to absent statin use in unmatched or propensity-matched analyses. CONCLUSIONS: While statins remain commonly utilized in pediatric HTRs, early consecutive statin therapy did not decrease CAV incidence or graft loss. The differing effects of statins on CAV development and progression in pediatric vs adult HTRs suggest differing risk and mediating factors and require further study.

17.
J Am Coll Cardiol ; 82(14): 1427-1441, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37758438

ABSTRACT

BACKGROUND: Hybrid palliation (bilateral pulmonary artery banding with or without ductal stenting) is an initial management strategy for infants with critical left heart obstruction and serves as palliation until subsequent operations are pursued. OBJECTIVES: This study sought to determine patient characteristics and factors associated with subsequent outcomes for infants who underwent hybrid palliation. METHODS: From 2005 to 2019, 214 of 1,236 prospectively enrolled infants within the Congenital Heart Surgeons' Society's critical left heart obstruction cohort underwent hybrid palliation across 24 institutions. Multivariable hazard modeling with competing risk methodology was performed to determine risk and factors associated with outcomes of biventricular repair, Fontan procedure, transplantation, or death. RESULTS: Preoperative comorbidities (eg, prematurity, low birth weight, genetic syndrome) were identified in 70% of infants (150 of 214). Median follow-up was 7 years, ranging up to 17 years. Overall 12-year survival was 55%. At 5 years after hybrid palliation, 9% had biventricular repair, 36% had Fontan procedure, 12% had transplantation, 35% died without surgical endpoints, and 8% were alive without an endpoint. Factors associated with transplantation were absence of ductal stent, older age, absent interatrial communication, smaller aortic root size, larger tricuspid valve area z-score, and larger left ventricular volume. Factors associated with death were low birth weight, concomitant genetic syndrome, cardiopulmonary bypass use during hybrid palliation, moderate to severe tricuspid valve regurgitation, and smaller ascending aortic size. CONCLUSIONS: Mortality remains high after hybrid palliation for infants with critical left heart obstruction. Nonetheless, hybrid palliation may facilitate biventricular repair for some infants and for others may serve as stabilization for intended functional univentricular palliation or primary transplantation.


Subject(s)
Fontan Procedure , Hypoplastic Left Heart Syndrome , Tricuspid Valve Insufficiency , Infant , Humans , Hypoplastic Left Heart Syndrome/surgery , Treatment Outcome , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Heart Ventricles/abnormalities , Heart Block , Palliative Care , Retrospective Studies
18.
World J Pediatr Congenit Heart Surg ; 14(5): 602-619, 2023 09.
Article in English | MEDLINE | ID: mdl-37737599

ABSTRACT

PURPOSE: We reviewed all 64 articles ever published by The Congenital Heart Surgeons' Society (CHSS) Data Center to estimate the academic impact of these peer-reviewed articles. MATERIALS AND METHODS: The Congenital Heart Surgeons' Society has performed research based on 12 Diagnostic Inception Cohorts. The first cohort (Transposition) began enrolling patients on January 1, 1985. We queried PubMed to determine the number of publications that referenced each of the 64 journal articles generated by the datasets of the 12 Diagnostic Inception Cohorts that comprise the CHSS Database. Descriptive summaries of the data were tabulated using mean with standard deviation and median with range. RESULTS: Sixty-four peer-reviewed papers have been published based on the CHSS Database. Fifty-nine peer-reviewed articles have been published based on the 12 Diagnostic Inception Cohorts, and five additional articles have been published based on Data Science. Excluding the recently established Diagnostic Inception Cohort for patients with Ebstein malformation of tricuspid valve, the number of papers published per cohort ranged from 1 for coarctation to 11 for transposition of the great arteries. The 11 articles generated from the CHSS Transposition Cohort were referenced by a total of 111 articles (median number of references per journal article = 9 [range = 0-22, mean = 10.1]). Overall, individual articles were cited by an average of 11 (mean), and a maximum of 41 PubMed-listed publications. Overall, these 64 peer-reviewed articles based on the CHSS Database were cited 692 times in PubMed-listed publications. The first CHSS peer-reviewed article was published in 1987, and during the 35 years from 1987 to 2022, inclusive, the annual number of CHSS publications has ranged from 0 to 7, with a mean of 1.8 publications per year (median = 1, mode = 1). CONCLUSION: Congenital Heart Surgeons' Society studies are widely referenced in the pediatric cardiac surgical literature, with over 10 citations per published article. These cohorts provide unique information unavailable in other sources of data. A tool to access this analysis is available at: [https://data-center.chss.org/multimedia/files/2022/CAI.pdf].


Subject(s)
Aortic Coarctation , Surgeons , Transposition of Great Vessels , Humans , Child , Arteries , Tricuspid Valve
19.
World J Pediatr Congenit Heart Surg ; 14(5): 552-558, 2023 09.
Article in English | MEDLINE | ID: mdl-37737605

ABSTRACT

John Kirklin stands out as one of the surgeons most identifiably responsible for bringing the field of open heart surgery to clinical reality and initiating scientific pursuits in the Congenital Heart Surgeons' Society. His accomplishments are perhaps best viewed in the context of other major contributions made by researchers and fellow surgeons, which collectively positioned Kirklin and other cardiac surgery pioneers to usher in the dawn of open heart surgery and later the Congenital Heart Surgeons' Society.


Subject(s)
Cardiac Surgical Procedures , Surgeons , Humans
20.
Pediatr Transplant ; 27(8): e14612, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37724046

ABSTRACT

BACKGROUND: Pediatric heart transplant patients are at greatest risk of allograft loss in the first year. We assessed whether machine learning could improve 1-year risk assessment using the Pediatric Heart Transplant Society database. METHODS: Patients transplanted from 2010 to 2019 were included. The primary outcome was 1-year graft loss free survival. We developed a prediction model using cross-validation, by comparing Cox regression, gradient boosting, and random forests. The modeling strategy with the best discrimination and calibration was applied to fit a final prediction model. We used Shapley additive explanation (SHAP) values to perform variable selection and to estimate effect sizes and importance of individual variables when interpreting the final prediction model. RESULTS: Cumulative incidence of graft loss or mortality was 7.6%. Random forests had favorable discrimination and calibration compared to Cox proportional hazards with a C-statistic (95% confidence interval [CI]) of 0.74 (0.72, 0.76) versus 0.71 (0.69, 0.73), and closer alignment between predicted and observed risk. SHAP values computed using the final prediction model indicated that the diagnosis of congenital heart disease (CHD) increased 1 year predicted risk of graft loss by 1.7 (i.e., from 7.6% to 9.3%), need for mechanical circulatory support increased predicted risk by 2, and single ventricle CHD increased predicted risk by 1.9. These three predictors, respectively, were also estimated to be the most important among the 15 predictors in the final model. CONCLUSIONS: Risk prediction models used to facilitate patient selection for pediatric heart transplant can be improved without loss of interpretability using machine learning.


Subject(s)
Heart Defects, Congenital , Heart Transplantation , Humans , Child , Risk Factors , Risk Assessment , Machine Learning , Allografts
SELECTION OF CITATIONS
SEARCH DETAIL
...