1.
BJU Int ; 128(2): 218-224, 2021 08.
Article in English | MEDLINE | ID: mdl-33306251

ABSTRACT

OBJECTIVES: To prospectively evaluate the performance of a pre-specified statistical model based on four kallikrein markers in blood (total prostate-specific antigen [PSA], free PSA, intact PSA, and human kallikrein-related peptidase 2), commercially available as the 4Kscore, in predicting Gleason Grade Group (GG) ≥2 prostate cancer at biopsy in an international multicentre study at three academic medical centres, and whether microseminoprotein-ß (MSP) adds predictive value. PATIENTS AND METHODS: A total of 984 men were prospectively enrolled at three academic centres. The primary outcome was GG ≥2 on prostate biopsy. Three pre-specified statistical models were used: a base model including PSA, age, digital rectal examination and prior negative biopsy; a model that added free PSA to the base model; and the 4Kscore. RESULTS: A total of 947 men were included in the final analysis and 273 (29%) had GG ≥2 on prostate biopsy. The base model area under the receiver operating characteristic curve of 0.775 increased to 0.802 with the addition of free PSA, and to 0.824 for the 4Kscore. Adding MSP to the 4Kscore model yielded an increase (0.014-0.019) in discrimination. In decision-curve analysis of clinical utility, the 4Kscore showed a benefit starting at a 7.5% threshold. CONCLUSION: A prospective multicentre evaluation of a pre-specified model based on four kallikrein markers (4Kscore) with the addition of MSP improves the predictive discrimination for GG ≥2 prostate cancer on biopsy and could be used to inform biopsy decision-making.


Subject(s)
Biomarkers, Tumor/blood , Kallikreins/blood , Models, Statistical , Prostatic Neoplasms/blood , Prostatic Neoplasms/pathology , Prostatic Secretory Proteins/blood , Aged , Cohort Studies , Humans , Internationality , Male , Middle Aged , Neoplasm Grading , Prospective Studies
2.
Kidney Int Rep ; 5(11): 2021-2031, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33163723

ABSTRACT

INTRODUCTION: Heterogeneity of nephrotic diseases and a lack of validated biomarkers limits interventions and reduces the ability to examine outcomes. Urinary CD80 is a potential biomarker for minimal change disease (MCD) steroid-sensitive nephrotic syndrome (NS). We investigated and validated a CD80 enzyme-linked immunosorbent assay (ELISA) in urine in a large cohort with a variety of nephrotic diseases. METHODS: A commercial CD80 ELISA was enhanced and analytically validated for urine. Patients were from Mayo Clinic (307) and Nephrotic Syndrome Study Network Consortium (NEPTUNE; 104) as follows: minimal change disease (MCD, 56), focal segmental glomerulosclerosis (FSGS, 92), lupus nephritis (LN, 25), IgA nephropathy (IgAN, 20), membranous nephropathy (MN, 49), autosomal dominant polycystic kidney disease (ADPKD, 10), diabetic nephropathy (DN; 106), pyuria (19), and controls (34). Analysis was by Kruskal-Wallis test, generalized estimating equation (GEE) models, and receiver operating characteristic (AUC) curve. RESULTS: Urinary CD80/creatinine values were highest in MCD compared to other glomerular diseases and were increased in DN with proteinuria >2 compared to controls (control = 36 ng/g; MCD = 139 ng/g, P < 0.01; LN = 90 ng/g, P < 0.12; FSGS = 66 ng/g, P = 0.18; DN = 63, P = 0.03; MN = 69 ng/g, P = 0.33; ng/g, P = 0.07; IgA = 19 ng/g, P = 0.09; ADPKD = 42, P = 0.36; and pyuria 31, P = 0.20; GEE, median, P vs. control). In proteinuric patients, CD80 concentration appears to be independent of proteinuria levels, suggesting that it is unrelated to nonspecific passage across the glomeruli. CD80/creatinine values were higher in paired relapse versus remission cases of MCD and FSGS (P < 0.0001, GEE). CONCLUSION: Using a validated ELISA, urinary CD80 levels discriminate MCD from other forms of NS (FSGS, DN, IgA, MN) and primary from secondary FSGS.

3.
Prostate ; 80(1): 51-56, 2020 01.
Article in English | MEDLINE | ID: mdl-31603253

ABSTRACT

BACKGROUND: To assess whether a prespecified statistical model based on the four kallikrein markers measured in blood-total, free, and intact prostate-specific antigen (PSA), together with human kallikrein-related peptidase 2 (hK2)-or any individual marker measured in pretreatment serum were associated with biochemical recurrence-free (BCR) or metastasis-free survival after radical prostatectomy (RP) in a subgroup of men with very high-risk disease. METHODS: We identified 106 men treated at Mayo Clinic from 2004 to 2008 with pathological Gleason grade group 4 to 5 or seminal vesicle invasion at RP. Univariable and multivariable Cox models were used to test the association between standard predictors (Kattan nomogram and GPSM [Gleason, PSA, seminal vesicle and margin status] score), kallikrein panel, and individual kallikrein markers with the outcomes. RESULTS: BCR and metastasis occurred in 67 and 30 patients, respectively. The median follow-up for patients who did not develop a BCR was 10.3 years (interquartile range = 8.2-11.8). In this high-risk group, neither Kattan risk, GPSM score, or the kallikrein panel model was associated with either outcome. However, after adjusting for Kattan risk and GPSM score, separately, preoperative intact PSA was associated with both outcomes while hK2 was associated with metastasis-free survival. CONCLUSIONS: Conventional risk prediction tools were poor discriminators for risk of adverse outcomes after RP (Kattan risk and GPSM risk) in patients with very high-risk disease. Further studies are needed to define the role of individual kallikrein marker forms in the blood to predict adverse prostate cancer outcomes after RP in this high-risk setting.


Subject(s)
Kallikreins/blood , Neoplasm Recurrence, Local/blood , Prostatic Neoplasms/blood , Aged , Biomarkers, Tumor/blood , Humans , Male , Middle Aged , Neoplasm Grading , Neoplasm Invasiveness , Neoplasm Metastasis , Neoplasm Recurrence, Local/pathology , Prostate-Specific Antigen/blood , Prostatectomy , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Risk Factors , Seminal Vesicles/pathology
4.
Am J Clin Pathol ; 150(6): 545-554, 2018 Oct 24.
Article in English | MEDLINE | ID: mdl-30169553

ABSTRACT

OBJECTIVES: To analyze consistency of reference limits and widths of reference intervals (RIs) calculated by six procedures and evaluate a protocol for merging intrainstitutional reference data. METHODS: The differences between reference limits were compared with "optimal" bias goals. Also, widths of the RIs were compared. RIs were calculated using Mayo-SAS quantile, EP Evaluator, and four International Federation of Clinical Chemistry and Laboratory Medicine methods: parametric and nonparametric (NP) with and without latent abnormal values exclusion (LAVE). Regression parameters from cotested samples were evaluated for harmonizing intrainstitutional reference data. RESULTS: Mayo-SAS quintile, LAVE(-)NP, and EP Evaluator generated similar RIs, but these RIs often were wider than RIs from parametric procedures. LAVE procedures generated narrower RIs for nutritional and inflammatory markers. Transformation with regression parameters did not ensure homogeneity of merged data. CONCLUSIONS: Parametric methods are recommended when inappropriate values cannot be excluded. The nonparametric procedures may generate wider RIs. Data sets larger than 200 are recommended for robust estimates. Caution should be exercised when merging intrainstitutional data.


Subject(s)
Clinical Laboratory Techniques/standards , Humans , Reference Values
5.
J Circ Biomark ; 6: 1849454417720151, 2017.
Article in English | MEDLINE | ID: mdl-28936267

ABSTRACT

Free human kallikrein 2 (free-hK2) and hK2 pro-form (pro-hK2) have been found to be increased in tumor tissues and serum from patients with prostate cancer. We established semiautomatic assays for free-hK2 and pro-hK2 using a research version of the Beckman Coulter ACCESS2 system. Serum samples from a cohort of 189 men undergoing radical prostatectomy for known high-risk disease were assayed for Prostate-Specific Antigen (PSA), free-PSA, free-hK2, and pro-hK2. Univariate Cox regression and multivariate models were used to predict both Gleason scores and progression-free survival (PFS). Free-hk2 levels ≥80 ng/L were predictive of both Gleason scores ≥7 (p = 0.04) and PFS (p = 0.03). PSA ≥8.0 µg/L also was predictive of PFS (p = 0.02). However, neither % free-PSA nor pro-hK2, when treated as continuous or cutoff variables were associated with Gleason score or PFS. Multivariable models showed that clinical stage T1c versus T2/T3, Gleason score ≥7, and PSA ≥8.0 µg/L or clinical stage T1c versus T2/T3, Gleason scores ≥7, and free-hK2 ≥80 ng/L were among the best models predicting PFS. Both free-hK2 and PSA in conjunction with clinical stage and Gleason score are good predictors of PFS in prostate cancer.

6.
Clin Chim Acta ; 467: 70-82, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27666761

ABSTRACT

OBJECTIVES: The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. METHODS: For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. RESULTS: The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. CONCLUSION: The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner.


Subject(s)
Clinical Laboratory Techniques/standards , Internationality , Healthy Volunteers , Humans , Normal Distribution , Reference Values
7.
Clin Chim Acta ; 467: 83-97, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27666762

ABSTRACT

OBJECTIVES: The intent of this study, based on a global multicenter study of reference values (RVs) for serum analytes was to explore biological sources of variation (SVs) of the RVs among 12 countries around the world. METHODS: As described in the first part of this paper, RVs of 50 major serum analytes from 13,396 healthy individuals living in 12 countries were obtained. Analyzed in this study were 23 clinical chemistry analytes and 8 analytes measured by immunoturbidimetry. Multiple regression analysis was performed for each gender, country by country, analyte by analyte, by setting four major SVs (age, BMI, and levels of drinking and smoking) as a fixed set of explanatory variables. For analytes with skewed distributions, log-transformation was applied. The association of each source of variation with RVs was expressed as the partial correlation coefficient (rp). RESULTS: Obvious gender and age-related changes in the RVs were observed in many analytes, almost consistently between countries. Compilation of age-related variations of RVs after adjusting for between-country differences revealed peculiar patterns specific to each analyte. Judged fromthe rp, BMI related changes were observed for many nutritional and inflammatory markers in almost all countries. However, the slope of linear regression of BMI vs. RV differed greatly among countries for some analytes. Alcohol and smoking-related changes were observed less conspicuously in a limited number of analytes. CONCLUSION: The features of sex, age, alcohol, and smoking-related changes in RVs of the analytes were largely comparable worldwide. The finding of differences in BMI-related changes among countries in some analytes is quite relevant to understanding ethnic differences in susceptibility to nutritionally related diseases.


Subject(s)
Clinical Laboratory Techniques/standards , Internationality , Age Factors , Body Mass Index , Ethnicity , Female , Humans , Male , Reference Values , Sex Factors
8.
BJU Int ; 120(1): 61-68, 2017 07.
Article in English | MEDLINE | ID: mdl-27743489

ABSTRACT

OBJECTIVE: To examine the use of the Prostate Health Index (PHI) as a continuous variable in multivariable risk assessment for aggressive prostate cancer in a large multicentre US study. MATERIALS AND METHODS: The study population included 728 men, with prostate-specific antigen (PSA) levels of 2-10 ng/mL and a negative digital rectal examination, enrolled in a prospective, multi-site early detection trial. The primary endpoint was aggressive prostate cancer, defined as biopsy Gleason score ≥7. First, we evaluated whether the addition of PHI improves the performance of currently available risk calculators (the Prostate Cancer Prevention Trial [PCPT] and European Randomised Study of Screening for Prostate Cancer [ERSPC] risk calculators). We also designed and internally validated a new PHI-based multivariable predictive model, and created a nomogram. RESULTS: Of 728 men undergoing biopsy, 118 (16.2%) had aggressive prostate cancer. The PHI predicted the risk of aggressive prostate cancer across the spectrum of values. Adding PHI significantly improved the predictive accuracy of the PCPT and ERSPC risk calculators for aggressive disease. A new model was created using age, previous biopsy, prostate volume, PSA and PHI, with an area under the curve of 0.746. The bootstrap-corrected model showed good calibration with observed risk for aggressive prostate cancer and had net benefit on decision-curve analysis. CONCLUSION: Using PHI as part of multivariable risk assessment leads to a significant improvement in the detection of aggressive prostate cancer, potentially reducing harms from unnecessary prostate biopsy and overdiagnosis.


Subject(s)
Early Detection of Cancer/methods , Prostate-Specific Antigen/blood , Prostate/pathology , Prostatic Neoplasms/pathology , Biopsy, Needle , Decision Support Techniques , Digital Rectal Examination , Humans , Male , Middle Aged , Neoplasm Grading , Prospective Studies , Prostatic Neoplasms/blood , Risk Assessment
9.
Clin Chem Lab Med ; 55(2): 189-194, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-27506603

ABSTRACT

This paper, prepared by the EFLM Task and Finish Group on Allocation of laboratory tests to different models for performance specifications (TFG-DM), is dealing with criteria for allocating measurands to the different models for analytical performance specifications (APS) recognized in the 1st EFLM Strategic Conference Consensus Statement. Model 1, based on the effect of APS on clinical outcome, is the model of choice for measurands that have a central role in the decision-making of a specific disease or clinical situation and where cut-off/decision limits are established for either diagnosing, screening or monitoring. Total cholesterol, glucose, HbA1c, serum albumin and cardiac troponins represent practical examples. Model 2 is based on components of biological variation and should be applied to measurands that do not have a central role in a specific disease or clinical situation, but where the concentration of the measurand is in a steady state. This is best achieved for measurands under strict homeostatic control in order to preserve their concentrations in the body fluid of interest, but it can also be applied to other measurands that are in a steady state in biological fluids. In this case, it is expected that the "noise" produced by the measurement procedure will not significantly alter the signal provided by the concentration of the measurand. This model especially applies to electrolytes and minerals in blood plasma (sodium, potassium, chloride, bicarbonate, calcium, magnesium, inorganic phosphate) and to creatinine, cystatin C, uric acid and total protein in plasma. Model 3, based on state-of-the-art of the measurement, should be used for all the measurands that cannot be included in models 1 or 2.


Subject(s)
Blood Chemical Analysis , Clinical Laboratory Techniques/methods , Clinical Laboratory Techniques/standards , Cholesterol/blood , Creatinine/blood , Cystatin C/blood , Electrolytes/blood , Glucose/analysis , Glycated Hemoglobin/analysis , Humans , Minerals/blood , Serum Albumin/analysis , Troponin/blood , Uric Acid/blood
10.
Endocrine ; 54(3): 671-680, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27444747

ABSTRACT

Available data associate lipids concentrations in men with body mass index, anabolic steroids, age, and certain cytokines. Data were less clear in women, especially across the full adult lifespan, and when segmented by premenopausal and postmenopausal status. SUBJECTS: 120 healthy women (60 premenopausal and 60 postmenopausal) in Olmsted County, MN, USA, a stable well studied clinical population. Dependent variables: measurements of 10 h fasting high-density lipoprotein cholesterol, total cholesterol, low-density lipoprotein cholesterol, and triglycerides. INDEPENDENT VARIABLES: testosterone, estrone, estradiol, 5-alpha-dihydrotestosterone, and sex-hormone binding globulin (by mass spectrometry); insulin, glucose, and albumin; abdominal visceral, subcutaneous, and total abdominal fat [abdominal visceral fat, subcutaneous fat, total abdominal fat by computerized tomography scan]; and a panel of cytokines (by enzyme-linked immunosorbent assay). Multivariate forward-selection linear-regression analysis was applied constrained to P < 0.01. Lifetime data: High-density lipoprotein cholesterol was correlated jointly with age (P < 0.0001, positively), abdominal visceral fat (P < 0.0001, negatively), and interleukin-6 (0.0063, negatively), together explaining 28.1 % of its variance (P = 2.3 × 10-8). Total cholesterol was associated positively with multivariate age only (P = 6.9 × 10-4, 9.3 % of variance). Triglycerides correlated weakly with sex-hormone binding globulin (P = 0.0115), and strongly with abdominal visceral fat (P < 0.0001), and interleukin-6 (P = 0.0016) all positively (P = 1.6 × 10-12, 38.9 % of variance). Non high-density lipoprotein cholesterol and low-density lipoprotein cholesterol correlated positively with both total abdominal fat and interleukin-8 (P = 2.0 × 10-5, 16.9 % of variance; and P = 0.0031, 9.4 % of variance, respectively). Premenopausal vs. postmenopausal comparisons identified specific relationships that were stronger in premenopausal than postmenopausal individuals, and vice versa. Age was a stronger correlate of low-density lipoprotein cholesterol; interleukin-6 of triglycerides and high-density lipoprotein; and both sex-hormone binding globulin and total abdominal fat of non high-density lipoprotein cholesterol in premenopausal than postmenopausal women. Conversely, sex-hormone binding globulin, abdominal visceral fat, interleukin-8, adiponectin were stronger correlates of triglycerides; abdominal visceral fat, and testosterone of high-density lipoprotein cholesterol; and age of both non high-density lipoprotein and low-density lipoprotein in postmenopausal than premenopausal women. Our data delineate correlations of total abdominal fat and interleukin-8 (both positively) with non high-density lipoprotein cholesterol and low-density lipoprotein cholesterol in healthy women across the full age range of 21-79 years along with even more specific associations in premenopausal and postmenopausal individuals. Whether some of these outcomes reflect causal relationships would require longitudinal and interventional or genetic studies.


Subject(s)
Abdominal Fat/metabolism , Lipids/blood , Postmenopause/blood , Premenopause/blood , Abdominal Fat/diagnostic imaging , Adult , Aged , Female , Gonadal Steroid Hormones/blood , Humans , Interleukin-6/blood , Interleukin-8/blood , Middle Aged , Sex Hormone-Binding Globulin/metabolism , Tomography, X-Ray Computed , Young Adult
11.
Scand J Clin Lab Invest ; 76(2): 177-80, 2016.
Article in English | MEDLINE | ID: mdl-26785381

ABSTRACT

OBJECTIVES: The effects of combining multiple calibrations on assay accuracy (bias) and measurement of calibration stability were investigated for total triiodothyronine (TT3), vitamin B12 and luteinizing hormone (LH) using Beckman Coulter's Access 2 analyzer. METHODS: Three calibration procedures (CC1, CC2 and CC3) combined 12, 34 and 56 calibrator measurements over 1, 2, and 3 days. Bias was calculated between target values and average measured value over 3 consecutive days after calibration. Using regression analysis of calibrator measurements versus measurement date, calibration stability was determined as the maximum number of days before a calibrator measurement exceeded 5% tolerance limits. RESULTS: Competitive assays (TT3, vitamin B12) had positive time regression slopes, while sandwich assay (LH) had a negative slope. Bias values for TT3 were -2.49%, 1.49%, and -0.50% using CC1, CC2 and CC3 respectively, with calibrator stability of 32, 20, and 30 days. Bias values for vitamin B12 were 2.44%, 0.91%, and -0.50%, with calibrator stability of 4, 9, and 12 days. Bias values for LH were 2.26%, 1.44% and -0.29% with calibrator stability of >43, 39 and 36 days. Measured stability was more consistent across calibration procedures using percent change rather than difference from target: 26 days for TT3, 12 days for B12 and 31 days for LH. CONCLUSIONS: Averaging over multiple calibrations produced smaller bias, consistent with improved accuracy. Time regression slopes in percent change were unaffected by number of calibration measurements but calibrator stability measured from the target value was highly affected by the calibrator value at time zero.


Subject(s)
Luteinizing Hormone/analysis , Triiodothyronine/analysis , Vitamin B 12/analysis , Calibration , Immunoassay/instrumentation , Immunoassay/standards , Quality Improvement , Reproducibility of Results
12.
Cancer Res ; 75(22): 4688-96, 2015 Nov 15.
Article in English | MEDLINE | ID: mdl-26432404

ABSTRACT

Clinical trials have established the benefit of androgen deprivation therapy (ADT) combined with radiotherapy in prostate cancer. ADT sensitizes prostate cancer to radiotherapy-induced death at least in part through inhibition of DNA repair machinery, but for unknown reasons, adjuvant ADT provides further survival benefits. Here, we show that androgen receptor (AR) expression and activity are durably upregulated following radiotherapy in multiple human prostate cancer models in vitro and in vivo. Moreover, the degree of AR upregulation correlates with survival in vitro and time to tumor progression in animal models. We also provide evidence of AR pathway upregulation, measured by a rise in serum levels of AR-regulated hK2 protein, in nearly 20% of patients after radiotherapy. Furthermore, these men were three-fold more likely to experience subsequent biochemical failure. Collectively, these data demonstrate that radiotherapy can upregulate AR signaling after therapy to an extent that negatively affects disease progression and/or survival.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiation Tolerance/physiology , Receptors, Androgen/biosynthesis , Animals , Blotting, Western , Cell Line, Tumor , Comet Assay , Fluorescent Antibody Technique , Humans , Luminescent Measurements , Male , Mice , Mice, SCID , Prostatic Neoplasms/metabolism , Real-Time Polymerase Chain Reaction , Up-Regulation , Xenograft Model Antitumor Assays
13.
J Urol ; 193(4): 1163-9, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25463993

ABSTRACT

PURPOSE: The Prostate Health Index (phi) is a new test combining total, free and [-2]proPSA into a single score. It was recently approved by the FDA and is now commercially available in the U.S., Europe and Australia. We investigate whether phi improves specificity for detecting clinically significant prostate cancer and can help reduce prostate cancer over diagnosis. MATERIALS AND METHODS: From a multicenter prospective trial we identified 658 men age 50 years or older with prostate specific antigen 4 to 10 ng/ml and normal digital rectal examination who underwent prostate biopsy. In this population we compared the performance of prostate specific antigen, % free prostate specific antigen, [-2]proPSA and phi to predict biopsy results and, specifically, the presence of clinically significant prostate cancer using multiple criteria. RESULTS: The Prostate Health Index was significantly higher in men with Gleason 7 or greater and "Epstein significant" cancer. On receiver operating characteristic analysis phi had the highest AUC for overall prostate cancer (AUCs phi 0.708, percent free prostate specific antigen 0.648, [-2]proPSA 0.550 and prostate specific antigen 0.516), Gleason 7 or greater (AUCs phi 0.707, percent free prostate specific antigen 0.661, [-2]proPSA 0.558, prostate specific antigen 0.551) and significant prostate cancer (AUCs phi 0.698, percent free prostate specific antigen 0.654, [-2]proPSA 0.550, prostate specific antigen 0.549). At the 90% sensitivity cut point for phi (a score less than 28.6) 30.1% of patients could have been spared an unnecessary biopsy for benign disease or insignificant prostate cancer compared to 21.7% using percent free prostate specific antigen. CONCLUSIONS: The new phi test outperforms its individual components of total, free and [-2]proPSA for the identification of clinically significant prostate cancer. Phi may be useful as part of a multivariable approach to reduce prostate biopsies and over diagnosis.


Subject(s)
Prostate-Specific Antigen/blood , Prostatic Neoplasms/blood , Prostatic Neoplasms/diagnosis , Protein Precursors/blood , Aged , Aged, 80 and over , Health Status Indicators , Humans , Male , Middle Aged , Prospective Studies
14.
J Urol ; 193(2): 690-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25132238

ABSTRACT

PURPOSE: Spliced variant forms of androgen receptor were recently identified in castration resistant prostate cancer cell lines and clinical samples. We identified the cistrome and gene signature of androgen receptor splice variants in castration resistant prostate cancer cell lines and determined the clinical significance of androgen receptor splice variant regulated genes. MATERIALS AND METHODS: The castration resistant prostate cancer cell line 22Rv1, which expresses full-length androgen receptor and androgen receptor splice variants endogenously, was used as the research model. We established 22Rv1-ARFL(-)/ARV(+) and 22Rv1-ARFL(-)/ARV(-) through RNA interference. Chromatin immunoprecipitation coupled with next generation sequencing and microarray techniques were used to identify the cistrome and gene expression profiles of androgen receptor splice variants in the absence of androgen. RESULTS: Androgen receptor splice variant binding sites were identified in 22Rv1-ARFL(-)/ARV(+). A gene set was regulated uniquely by androgen receptor splice variants but not by full-length androgen receptor in the absence of androgen. Integrated analysis revealed that some genes were directly modulated by androgen receptor splice variants. Unsupervised clustering analysis showed that the androgen receptor splice variant gene signature differentiated benign from malignant prostate tissue as well as localized prostate cancer from metastatic castration resistant prostate cancer specimens. Some genes that were modulated uniquely by androgen receptor splice variants also correlated with histological grade and biochemical failure. CONCLUSIONS: Androgen receptor splice variants can bind to DNA independent of full-length androgen receptor in the absence of androgen and modulate a unique set of genes that is not regulated by full-length androgen receptor. The androgen receptor splice variant gene signature correlates with disease progression. It distinguishes primary cancer from castration resistant prostate cancer specimens and benign from malignant prostate specimens.


Subject(s)
Gene Expression Regulation, Neoplastic , Prostatic Neoplasms, Castration-Resistant/genetics , Receptors, Androgen/genetics , Transcriptome , High-Throughput Nucleotide Sequencing , Humans , Male , Protein Isoforms , Tumor Cells, Cultured
15.
Arch Pathol Lab Med ; 138(10): 1381-6, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25268201

ABSTRACT

CONTEXT: Prostate-specific antigen (PSA) is a 34-kDa glycoprotein with chymotrypsin-like enzyme activity that circulates both in free forms and complexed to various enzyme inhibitors including antichymotrypsin and α2-macroglobulin. Prostate-specific antigen bound to α2-macroglobulin is not detected by commercial PSA immunoassays. OBJECTIVE: To develop a mass spectrometry assay that detects the same forms of PSA as the immunoassays, which could serve as a reference for harmonizing PSA immunoassays. DESIGN: Prostate-specific antigen was immune extracted from serum, trypsin was digested, and the LSEPAELTDAVK peptide was quantitated on an API 5000 spectrometer. Calibrators were made by adding 10% free and 90% antichymotrypsin-bound PSA to female sera. The assay was standardized to the World Health Organization 96/670 reference standard. Validation of clinical utility and comparisons with 2 immunoassays (Roche cobas and Beckman Access) were performed using frozen sera aliquots from 100 men undergoing prostate biopsy (50 negative, 50 with cancer) and 5 serial samples collected over time from 5 men with advanced prostate cancer. RESULTS: The antibody extraction efficiency was greater than 99%. The assay has an analytic range from 1.2 to 76 ng/mL, with precision ranging from 8.6% at 1.5 ng/mL to 5.4% at 27 ng/mL. The mass spectrometry assay correlated well with 2 immunoassays. All 3 assays showed statistically equivalent separation of prostate cancer from benign disease using receiver operating characteristic curve analysis. CONCLUSIONS: This mass spectrometry assay can reliably measure PSA concentrations in human serum and could serve as a reference standard for harmonizing PSA immunoassays.


Subject(s)
Peptide Fragments/analysis , Prostate-Specific Antigen/blood , Prostatic Neoplasms/blood , Analytic Sample Preparation Methods , Antibodies, Monoclonal/chemistry , Calibration , Humans , Indicators and Reagents/chemistry , Male , Peptide Fragments/chemistry , Peptide Fragments/isolation & purification , Peptide Fragments/metabolism , Prostate-Specific Antigen/chemistry , Prostate-Specific Antigen/isolation & purification , Prostate-Specific Antigen/metabolism , Prostatic Neoplasms/diagnosis , Proteolysis , ROC Curve , Reproducibility of Results , Tandem Mass Spectrometry , Trypsin/metabolism
16.
Arch Pathol Lab Med ; 138(9): 1173-81, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25171699

ABSTRACT

CONTEXT: Both the regulations in the Clinical Laboratory Improvement Amendments of 1988 (CLIA) and the checklists of the College of American Pathologists (CAP) Laboratory Accreditation Program require clinical laboratories to verify performance characteristics of quantitative test systems. Laboratories must verify performance claims when introducing an unmodified, US Food and Drug Administration-cleared or approved test system, and they must comply with requirements for periodic calibration and calibration verification for existing test systems. They must also periodically verify the analytical measurement range of many quantitative test systems. OBJECTIVE: To provide definitions for many of the terms used in these regulations, to describe a set of basic analyses that laboratories may adapt to demonstrate compliance with both CLIA and the CAP Laboratory Accreditation Program checklists for performing calibration verification and for verifying the analytical measurement range of test systems, to review some of the recommended procedures for establishing performance goals, and to provide data illustrating the performance goals used in some of the CAP's calibration verification and linearity surveys. DATA SOURCES: The CAP's calibration verification and linearity survey programs, the CLIA regulations, the Laboratory Accreditation Program requirements, and published literature were used to meet these objectives. CONCLUSIONS: Calibration verification and linearity and analytical measurement range verification should be performed using suitable materials with assessment of results using well-defined evaluation protocols. We describe the CAP's calibration verification and linearity programs that may be used for these purposes.


Subject(s)
Evaluation Studies as Topic , Laboratories/standards , Pathology, Clinical/standards , Systems Analysis , Calibration/standards , Chemistry Techniques, Analytical/standards , Drug Monitoring/standards , Humans , Linear Models , Reference Values
17.
Clin Biochem ; 47(16-17): 158-63, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25130957

ABSTRACT

OBJECTIVES: We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). METHODS: Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. RESULTS: All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. CONCLUSIONS: The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits.


Subject(s)
Immunoassay/methods , Ferritins/analysis , Reproducibility of Results , Thyroxine/analysis , Triiodothyronine/analysis
18.
Clin Chim Acta ; 432: 127-34, 2014 May 15.
Article in English | MEDLINE | ID: mdl-24747109

ABSTRACT

BACKGROUND: Diagnostic decisions based on decision limits according to medical guidelines are different from the majority of clinical decisions due to the strict dichotomization of patients into diseased and non-diseased. Consequently, the influence of analytical performance is more critical than for other diagnostic decisions where much other information is included. The aim of this opinion paper is to investigate consequences of analytical quality and other circumstances for the outcome of "Guideline-Driven Medical Decision Limits". TERMS: Effects of analytical bias and imprecision should be investigated separately and analytical quality specifications should be estimated accordingly. BIOLOGICAL VARIATION AND ANALYTICAL PERFORMANCE: Use of sharp decision limits doesn't consider biological variation and effects of this variation are closely connected with the effects of analytical performance. Such relationships are investigated for the guidelines for HbA1c in diagnosis of diabetes and in risk of coronary heart disease based on serum cholesterol. The effects of a second sampling in diagnosis give dramatic reduction in the effects of analytical quality showing minimal influence of imprecision up to 3 to 5% for two independent samplings, whereas the reduction in bias is more moderate and a 2% increase in concentration doubles the percentage of false positive diagnoses, both for HbA1c and cholesterol. FREQUENCY OF FOLLOW-UP LABORATORY TESTS: An alternative approach comes from the current application of guidelines for follow-up laboratory tests according to clinical procedure orders, e.g. frequency of parathyroid hormone requests as a function of serum calcium concentrations. Here, the specifications for bias can be evaluated from the functional increase in requests for increasing serum calcium concentrations. PROBABILITY FUNCTION FOR DIAGNOSES: In consequence of the difficulties with biological variation and the practical utilization of concentration dependence of frequency of follow-up laboratory tests already in use, a kind of probability function for diagnosis as function of the key-analyte is proposed.


Subject(s)
Clinical Laboratory Techniques/methods , Practice Guidelines as Topic , Bias , Clinical Laboratory Techniques/standards , False Positive Reactions , Humans , Limit of Detection , Probability , Quality Assurance, Health Care , Reference Values , Reproducibility of Results , Research Design
19.
Metabolism ; 63(6): 783-92, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24746136

ABSTRACT

OBJECTIVE: Sex-hormone binding globulin (SHBG) concentrations across the adult female lifespan are not well defined. To address this knowledge gap, SHBG was quantified by both immunological and criterion methods, viz, mass spectrometry (MS). SETTING: Center for Translational Science Activities (CTSA). PARTICIPANTS: Healthy nonpregnant women (N=120) ages 21 to 79 years. OUTCOMES: SHBG, testosterone (T), estradiol (E2) and estrone (E1) each determined by MS. Uni- and multivariate regression of SHBG concentrations on age, body mass index (BMI), total and visceral abdominal fat (TAF, AVF), albumin, glucose, insulin, sex steroids, selected cytokines, blood pressure, and lipids. RESULTS: By univariate regression, MS-estimated SHBG correlated negatively with BMI, TAF, AVF, insulin, free T and bioavailable T (bio T) (each P≤10(-4)), but not with blood pressure or lipids. By stepwise multivariate regression analysis, free and total T (both positive) and bio T (negative) were correlated with SHBG in all 4 assays (each P<10(-15), R(2)≥0.481). In addition, TAF and BMI were negatively associated with SHBG (P≤0.0066) in 2 SHBG assays, and estrone and IL-8 with SHBG weakly (P≤0.035) in one SHBG assay each. When nonsignificant cytokines were excluded, SHBG was jointly associated with AVF, total T and HDL (P<10(-9), R(2)=0.358). CONCLUSION: According to MS, three metabolic factors, T, AVF and HDL, together explain more than one-third of the interindividual variation in SHBG levels. We speculate that these measures reflect insulin action.


Subject(s)
Intra-Abdominal Fat/metabolism , Mass Spectrometry , Sex Hormone-Binding Globulin/metabolism , Testosterone/blood , Adult , Aged , Blood Glucose/metabolism , Body Mass Index , Cholesterol, HDL/blood , Estradiol/blood , Estrone/blood , Female , Humans , Insulin/blood , Interleukins/blood , Menopause , Middle Aged , Serum Albumin/metabolism , Triglycerides/blood , Tumor Necrosis Factor-alpha/blood
20.
Am J Clin Pathol ; 141(4): 527-33, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24619754

ABSTRACT

OBJECTIVES: Harmonization of prostate-specific antigen (PSA) immunoassays is important for good patient care. The specificity of the antibodies used to detect circulating PSA could cause differences in the PSA measurements. METHODS: We used mass spectrometry (MS) to quantitate the concentration of five peptides cleaved from trypsin digestion of PSA and compared these measurements with six automated immunoassays. Linear regression and a mixed-effects model were used to analyze the results. RESULTS: PSA measurements from the immunoassays and the five MS peptide assays were highly correlated (R(2) > 0.99), but the recovery of the World Health Organization standard and the regression slopes differed across assays. The same relative patterns of immunoassay differences were seen in comparing their results with each of the five MS peptide measurements from different parts of the circulating PSA molecules. CONCLUSIONS: Mass spectrometry quantitation of peptides derived from trypsin digestion of immune-extracted PSA could be used to harmonize PSA immunoassays.


Subject(s)
Peptide Fragments/blood , Prostate-Specific Antigen/chemistry , Tandem Mass Spectrometry/methods , Amino Acid Sequence , Chromatography, Liquid/methods , Epitopes , Female , Humans , Immunoassay/standards , Male , Prostate-Specific Antigen/immunology , Prostate-Specific Antigen/metabolism , Reproducibility of Results , Trypsin/metabolism
SELECTION OF CITATIONS