Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Respir Care ; 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39187290

ABSTRACT

BACKGROUND: Aerosol therapy is commonly used during treatment with high-flow nasal cannula (HFNC) in the intensive care unit (ICU). Heated humidification inside the HFNC tubing circuit leads to unwanted condensation, which may greatly limit the efficiency of drug delivery. In this study, we aimed to investigate whether a novel humidification system, which decouples temperature and humidity control, can improve the delivered dose. METHODS: In a bench study setup, fluorescein sodium solution was nebulized using a vibrating-mesh nebulizer in an infant HFNC circuit to measure the delivered dose, with a conventional versus a novel decoupled humidifier. The deposition of fluorescein inside each breathing circuit component and a final collection filter at the end of the nasal cannula was collected and quantified with a UV-vis spectrometer. Droplet sizes at different sections of the breathing circuit were measured by laser diffraction. Three air flow rates: 5, 10 and 15 L/min, and two nebulizer positions: (1) at the humidifier and (2) after the inspiratory tube, were tested. RESULTS: The delivered dose decreased with increasing flow rate for the conventional setup and was higher when the nebulizer was placed after the inspiratory tube. Turning off the conventional humidifier 10 minutes before and during nebulization did not improve the delivered dose. The decoupled humidifier achieved a significantly higher (p = .002) delivered dose than the conventional setup. The highest delivered dose obtained by the decoupled humidifier was 62.4% when the nebulizer was placed after the humidifier, while the highest dose obtained for the conventional humidifier was 36.3% by placing the nebulizer after the inspiratory tube. CONCLUSIONS: In this bench study, we found that the delivered dose for an infant HFNC nebulization setup could be improved significantly by decoupling temperature and humidity control inside the HFNC circuit, as it reduced drug deposition inside the breathing circuit.

2.
Intensive Care Med Exp ; 12(1): 21, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38424411

ABSTRACT

BACKGROUND: Obtaining a properly fitting non-invasive ventilation (NIV) mask to treat acute respiratory failure is a major challenge, especially in young children and patients with craniofacial abnormalities. Personalization of NIV masks holds promise to improve pediatric NIV efficiency. As current customization methods are relatively time consuming, this study aimed to test the air leak and surface pressure performance of personalized oronasal face masks using 3D printed soft materials. Personalized masks of three different biocompatible materials (silicone and photopolymer resin) were developed and tested on three head models of young children with abnormal facial features during preclinical bench simulation of pediatric NIV. Air leak percentages and facial surface pressures were measured and compared for each mask. RESULTS: Personalized NIV masks could be successfully produced in under 12 h in a semi-automated 3D production process. During NIV simulation, overall air leak performance and applied surface pressures were acceptable, with leak percentages under 30% and average surface pressure values mostly remaining under normal capillary pressure. There was a small advantage of the masks produced with soft photopolymer resin material. CONCLUSION: This first, proof-of-concept bench study simulating NIV in children with abnormal facial features, showed that it is possible to obtain biocompatible, personalized oronasal masks with acceptable air leak and facial surface pressure performance using a relatively short, and semi-automated production process. Further research into the clinical value and possibilities for application of personalized NIV masks in critically ill children is needed.

3.
Front Pediatr ; 10: 873426, 2022.
Article in English | MEDLINE | ID: mdl-35573957

ABSTRACT

Non-invasive ventilation (NIV) is increasingly used in the support of acute respiratory failure in critically ill children admitted to the pediatric intensive care unit (PICU). One of the major challenges in pediatric NIV is finding an optimal fitting mask that limits air leakage, in particular for young children and those with specific facial features. Here, we describe the development of a pediatric head-lung model, based on 3D anthropometric data, to simulate pediatric NIV in a 1-year-old child, which can serve as a tool to investigate the effectiveness of NIV masks. Using this model, the primary aim of this study was to determine the extent of air leakage during NIV with our recently described simple anesthetic mask with a 3D-printed quick-release adaptor, as compared with a commercially available pediatric NIV mask. The simple anesthetic mask provided a better seal resulting in lower air leakage at various positive pressure levels as compared with the commercial mask. These data further support the use of the simple anesthetic mask as a reasonable alternative during pediatric NIV in the acute setting. Moreover, the pediatric head-lung model provides a promising tool to study the applicability and effectiveness of customized pediatric NIV masks in the future.

4.
Front Pediatr ; 9: 710829, 2021.
Article in English | MEDLINE | ID: mdl-34504814

ABSTRACT

Non-invasive ventilation (NIV) is increasingly used in the supportive treatment of acute respiratory failure in children in the pediatric intensive care unit (PICU). However, finding an optimal fitting commercial available NIV face mask is one of the major challenges in daily practice, in particular for young children and those with specific facial features. Large air leaks and pressure-related skin injury due to suboptimal fit are important complications associated with NIV failure. Here, we describe a case of a 4-year old boy with cardiofaciocutaneous syndrome and rhinovirus-associated hypoxic acute respiratory failure who was successfully supported with NIV delivered by a simple anesthetic mask connected to a headgear by an in-house developed and 3D printed adaptor. This case is an example of the clinical challenge related to pediatric NIV masks in the PICU, but also shows the potential of alternative NIV interfaces e.g., by using a widely available and relatively cheap simple anesthetic mask. Further personalized strategies (e.g., by using 3D scanning and printing techniques) that optimize NIV mask fitting in children are warranted.

5.
Respir Care ; 66(6): 891-896, 2021 06.
Article in English | MEDLINE | ID: mdl-33536316

ABSTRACT

BACKGROUND: There is a persistent concern over the risk of respiratory pathogen transmission, including SARS-CoV-2, via the formation of aerosols (ie, a suspension of microdroplets and residual microparticles after evaporation) generated during high-flow nasal cannula (HFNC) oxygen therapy in critically ill patients. This concern is fueled by limited available studies on this subject. In this study, we tested our hypothesis that HFNC treatment is not associated with increased aerosol formation as compared to conventional oxygen therapy. METHODS: We used laser light scattering and a handheld particle counter to detect and quantify aerosols in healthy subjects and in adults with acute respiratory disease, including COVID-19, during HFNC or conventional oxygen therapy. RESULTS: The use of HFNC was not associated with increased formation of aerosols as compared to conventional oxygen therapy in both healthy subjects (n = 3) and subjects with acute respiratory disease, including COVID-19 (n = 17). CONCLUSIONS: In line with scarce previous clinical and experimental findings, our results indicate that HFNC itself does not result in overall increased aerosol formation as compared to conventional oxygen therapy. This suggests there is no increased risk of respiratory pathogen transmission to health care workers during HFNC.


Subject(s)
COVID-19 , Noninvasive Ventilation , Respiratory Insufficiency , Adult , Aerosols , Cannula , Critical Illness , Humans , Oxygen Inhalation Therapy , Respiratory Insufficiency/etiology , Respiratory Insufficiency/therapy , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL