Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 95(4): 042501, 2005 Jul 22.
Article in English | MEDLINE | ID: mdl-16090802

ABSTRACT

The FRS-ESR facility at GSI provides unique conditions for precision measurements of large areas on the nuclear mass surface in a single experiment. Values for masses of 604 neutron-deficient nuclides (30 < or = Z < or = 92) were obtained with a typical uncertainty of 30 microu. The masses of 114 nuclides were determined for the first time. The odd-even staggering (OES) of nuclear masses was systematically investigated for isotopic chains between the proton shell closures at Z = 50 and Z = 82. The results were compared with predictions of modern nuclear models. The comparison revealed that the measured trend of OES is not reproduced by the theories fitted to masses only. The spectral pairing gaps extracted from models adjusted to both masses, and density related observables of nuclei agree better with the experimental data.

2.
Phys Rev Lett ; 95(5): 052501, 2005 Jul 29.
Article in English | MEDLINE | ID: mdl-16090870

ABSTRACT

We report the first measurement of a ratio lambda(beta(b))/lambda(beta(c)) of bound-state ((lambda(beta(b))) and continuum-state (lambda(beta(c))) beta(-)-decay rates for the case of bare 207Tl81+ ions. These ions were produced at the GSI fragment separator FRS by projectile fragmentation of a 208Pb beam. After in-flight separation with the Brho-deltaE-Brho method, they were injected into the experimental storage-ring ESR at an energy of 400.5A MeV, stored, and electron cooled. The number of both the 207Tl81+ ions and their bound-state beta(-)-decay daughters, hydrogen-like 207Pb81+ ions, were measured as a function of storage time by recording their Schottky-noise intensities. The experimental result, lambda(beta(b))/lambda(beta(c)) = 0.188(18), is in very good agreement with the value of 0.171(1) obtained from theory employing spectra of allowed transitions.

3.
Environ Toxicol Chem ; 20(1): 205-12, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11351410

ABSTRACT

A model for risk assessment was built for simultaneous, congener-specific PCB bioaccumulation from sediment to fish to otters (Lutra lutra). Toxic equivalence factors (TEFs) were used to sum individual congeners in otters to a toxic equivalent concentration (TEQ) relative to 2,3,7,8-tetrachlorodibenzo-p-dioxin. Microbial dechlorination and burial in sediments and bioaccumulation are modeled to predict time trends of PCB concentrations in otters. Effects of accumulated PCBs on otters were assessed for vitamin A metabolism and reproduction, taking model uncertainty into account. Three locations in The Netherlands were modeled with PCB levels in sediment of 1 to 171 pg TEQ/g organic carbon (OC). Almost 100% reduction in litter size was predicted for the most polluted area in 1996. Due to large associated uncertainty, a period of 25 to 80 years may be needed for recovery of otter vitamin A levels and litter size at this site. Calculated median sediment quality criteria (SQC) range between 1 and 12 pg TEQ/g OC, depending on the chosen effect criterion. Uncertainty in calculated effects and SQCs is substantial and is mainly caused by uncertainty in PCB congener 126 accumulation.


Subject(s)
Otters/physiology , Polychlorinated Biphenyls/toxicity , Water Pollutants, Chemical/toxicity , Animals , Chlorine/analysis , Female , Fishes , Food Chain , Male , Mink/physiology , Models, Biological , Monte Carlo Method , Polychlorinated Biphenyls/analysis , Probability , Risk Assessment , Sex Characteristics , Water Pollutants, Chemical/analysis
4.
Phys Rev Lett ; 85(15): 3109-12, 2000 Oct 09.
Article in English | MEDLINE | ID: mdl-11019278

ABSTRACT

The Lyman- alpha transitions of hydrogenlike uranium associated with electron capture were measured in collisions of stored bare U (92+) ions with gaseous targets at the storage ring ESR. By applying the deceleration technique, the experiment was performed at slow collision energies in order to reduce the uncertainties associated with Doppler corrections. From the measured centroid energies, a ground state Lamb shift of 468 eV+/-13 eV is deduced which gives the most precise test of quantum electrodynamics for a single electron system in the strong field regime. In particular, the technique applied paves the way towards the 1 eV precision regime.

SELECTION OF CITATIONS
SEARCH DETAIL
...