Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 608
Filter
1.
Oper Dent ; 49(3): 282-289, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38632854

ABSTRACT

OBJECTIVES: To evaluate the effect of various toothpaste tablets on gloss and surface roughness of resin-based composite. METHODS AND MATERIALS: Sixty-four resin-based composite specimens were divided into four groups of 16 specimens each. Gloss and roughness were measured before and after simulated brushing with three types of toothpaste tablets and one conventional toothpaste: CT: Chewtab Toothpaste Tablets; AT: Anticavity Toothpaste Tablets; HC: Charcoal Toothpaste Tablets; CP: Cavity Protection toothpaste. The Kruskal-- Wallis procedure was performed to compare the differences by groups. Post-hoc comparisons were conducted with Bonferroni corrections (α=0.05). RESULTS: There was a significant drop in gloss for all groups. CT and AT maintained the highest gloss with means of 81.6 GU and 74.1 GU, respectively. The lowest gloss of 24.5 GU was observed for HC. There was a significant increase in roughness for all groups except for CT. CT had the lowest roughness with a mean of 0.034 µm, while HC had the highest roughness with a mean of 0.074 µm. There was a significant correlation between post-brushing gloss and post-brushing roughness (p<0.001, r=-0.884). CONCLUSION: Chewtab Toothpaste Tablets had the least effect on gloss and roughness, while Charcoal Toothpaste Tablets had the most negative effect on the surface properties of resin-based composites.


Subject(s)
Composite Resins , Surface Properties , Toothpastes , Toothpastes/chemistry , Composite Resins/chemistry , Materials Testing , Humans , Tablets , Dental Materials/chemistry , Toothbrushing
2.
Sci Rep ; 14(1): 4716, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38413803

ABSTRACT

This cutting-edge study delves into regional magmatism in northern Taiwan through advanced 3-D P- and S-wave frequency-dependent attenuation tomography. Positioned at the dynamic convergence boundary between the Philippine Sea Plate and the Eurasian Plate, Taiwan experiences moderate earthquakes and intriguing volcanic activity, with a focus on the Tatun volcano group. Employing the Formosa seismic array for high-resolution results, our research identifies high-attenuation anomalies (low Q) beneath the northern Taiwan volcanic zone (NTVZ) and offshore submarine volcanoes, indicative of potential hydrothermal activities and magma reservoirs at varying depths. Additionally, we explore low-attenuation anomalies (high Q) in the forearc region of the Ryukyu subduction zone, suggestive of partial saturation linked to serpentinization processes resulting from seawater infiltration or forearc mantle hydration. These findings shed light on the complex geological features and provide essential insights into the crustal properties of northern Taiwan, contributing to a deeper understanding of its magmatic evolution and tectonic processes.

3.
Hong Kong Med J ; 30(1): 16-24, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38226406

ABSTRACT

INTRODUCTION: Vaccination is a key strategy to control the coronavirus disease 2019 (COVID-19) pandemic. Safety concerns strongly influence vaccine hesitancy. Disease transmission during pregnancy could exacerbate risks of preterm birth and perinatal mortality. This study examined patterns of vaccination and transmission among pregnant and postnatal women during the fifth wave of COVID-19 in Hong Kong. METHODS: The Antenatal Record System and Clinical Management System of the Hospital Authority was used to retrieve information concerning the demographic characteristics, vaccination history, COVID-19 status, and obstetric outcomes of women who were booked for delivery at Queen Mary Hospital in Hong Kong and had attended the booking antenatal visit from 1 July 2021 to 30 June 2022. RESULTS: Among 2396 women in the cohort, 2006 (83.7%), 1843 (76.9%), and 831 (34.7%) had received the first, second, and third doses of COVID-19 vaccine, respectively. Among 1012 women who had received the second dose, 684 (67.6%) women were overdue for their third dose. There were 265 (11.1%) reported COVID-19 cases. Women aged 20 to 29 years had a low vaccination rate but the highest disease rate (19.1%). The disease rate was more than tenfold higher in women who had no (20.3%) or incomplete (18.8%) vaccination, compared with women who had complete vaccination (2.1%; P<0.001). CONCLUSION: Acceptance of COVID-19 vaccination was low in pregnant women. Urgent measures are needed to promote vaccination among pregnant women before the next wave of COVID-19.


Subject(s)
COVID-19 , Premature Birth , Infant, Newborn , Pregnancy , Female , Humans , Male , Tertiary Care Centers , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19 Vaccines , Hong Kong/epidemiology , Vaccination
4.
Appl Radiat Isot ; 200: 110914, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37423060

ABSTRACT

CdTe-based detectors have the problem of Te-rich surface layers caused by Br etching, which is one of fabrication steps. Te-rich layer acts as a trapping center and serves as an additional source of charge carriers, thereby degrading transport property of charge carriers and enriching leakage current on surface of detector. To solve this problem, we introduced sodium hypochlorite (NaOCl) as a passivant, and investigated its effect on Cd0.95Mn0.05Te0.98Se0.02 (CMTS), by analyzing chemical state of surface and its performance. After passivation with NaOCl, the results of X-ray photoelectron spectroscopy (XPS) shows the formation of tellurium oxide and elimination of water on CMTS surface, and CMTS presented enhanced performance with Am-241 radioisotope. Consequently, it is demonstrated that the passivation with NaOCl reduces leakage current, compensates defect, and elevates transport of charge carriers, thereby decreasing charge loss of carriers and improving performance of CMTS detector.

5.
Nature ; 609(7926): 269-275, 2022 09.
Article in English | MEDLINE | ID: mdl-36071190

ABSTRACT

Nuclear fusion is one of the most attractive alternatives to carbon-dependent energy sources1. Harnessing energy from nuclear fusion in a large reactor scale, however, still presents many scientific challenges despite the many years of research and steady advances in magnetic confinement approaches. State-of-the-art magnetic fusion devices cannot yet achieve a sustainable fusion performance, which requires a high temperature above 100 million kelvin and sufficient control of instabilities to ensure steady-state operation on the order of tens of seconds2,3. Here we report experiments at the Korea Superconducting Tokamak Advanced Research4 device producing a plasma fusion regime that satisfies most of the above requirements: thanks to abundant fast ions stabilizing the core plasma turbulence, we generate plasmas at a temperature of 100 million kelvin lasting up to 20 seconds without plasma edge instabilities or impurity accumulation. A low plasma density combined with a moderate input power for operation is key to establishing this regime by preserving a high fraction of fast ions. This regime is rarely subject to disruption and can be sustained reliably even without a sophisticated control, and thus represents a promising path towards commercial fusion reactors.

6.
BJA Educ ; 22(10): 387-395, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36132878
7.
Sci Rep ; 12(1): 13066, 2022 Jul 29.
Article in English | MEDLINE | ID: mdl-35906398

ABSTRACT

Brillouin light scattering experiments were performed for lead zirconate single crystals doped with niobium. Special attention was paid to the elastic mode softening near phase transition temperatures. The results are compared with data obtained by Raman light scattering experiments. We observed that the interaction between acoustic and optic modes is responsible for symmetry breaking far above TC, leading to polar regions' appearance. No changes in the acoustic mode frequency and its damping are observed at TC, where ε(T) exhibits a maximum value. The absence of these changes and the central peak observed in Raman experiments suggest that the phase transition at TC is mainly of the order-disorder type. The origin of other phase transitions is discussed as well.

8.
Emerg Radiol ; 29(3): 585-593, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35102473

ABSTRACT

Chest pain is a common reason for presentation to the emergency department. In many cases, a CTPA or CT thoracic aorta is performed during work up to assess for pulmonary embolism and aortic pathology, critical diagnoses that can be difficult to out rule clinically. However, the causes of chest pain are myriad. It is therefore crucial for the interpreting radiologist to be cognizant of other potential etiologies when interpreting these studies. The purpose of this pictorial essay is to highlight the causes of non-PE or aortic-related chest pain and provide radiologists with a structured approach to interpreting these studies, ensuring a comprehensive search strategy so that important pathologies are not missed.


Subject(s)
Emergency Service, Hospital , Pulmonary Embolism , Chest Pain/diagnostic imaging , Humans , Pulmonary Embolism/diagnostic imaging , Radiologists , Retrospective Studies
9.
Clin Exp Dermatol ; 47(4): 700-708, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34762763

ABSTRACT

BACKGROUND: Calciphylaxis is a life-threatening cutaneous ulcerative/necrotic disease characterized by vascular calcification/occlusion. It occurs most commonly in end-stage kidney disease (ESKD), known as uraemic calciphylaxis (UC) but can also occur in patients with chronic kidney disease (CKD) and normal kidney function (nonuraemic calciphylaxis; NUC). There are few large series of NUC in the literature. AIM: To compare the clinicopathological features of UC and NUC. METHODS: We retrospectively compared the clinicopathological features of 35 patients with NUC during the period 2010-2020 with those of 53 patients with UC (control group). Cases were classified as NUC in the absence of all of the following: ESKD, significant CKD (defined as serum creatinine > 3 mg/dL or creatinine clearance < 15 mL/min) and acute kidney injury requiring kidney replacement therapy or kidney transplantation. RESULTS: NUC represented 40% of the total cases, and there was a higher number of women (P < 0.01) and a higher median body mass index (P = 0.06) compared with the control UC group. Elevated parathyroid hormone was present in 44% of patients with NUC. Most of the tested patients were positive for lupus anticoagulants (56%). NUC biopsies showed a higher rate of extravascular calcium deposits (73% vs. 47%, P = 0.03). Dermal reactive vascular proliferation was the most common dermal change (32%). CONCLUSIONS: NUC is more common than previously reported and shows a higher predilection for obese postmenopausal women. Undiagnosed hyperparathyroidism shows a possible association with NUC. Lupus anticoagulants were positive in most patients. NUC biopsies are more likely than UC biopsies to display extravascular calcium deposition.


Subject(s)
Calciphylaxis , Kidney Failure, Chronic , Renal Insufficiency, Chronic , Calciphylaxis/diagnosis , Female , Humans , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/therapy , Renal Insufficiency, Chronic/complications , Retrospective Studies , Risk Factors
10.
Hong Kong Med J ; 27(6): 399-404, 2021 12.
Article in English | MEDLINE | ID: mdl-34949729

ABSTRACT

INTRODUCTION: Heavy menstrual bleeding is a common gynaecological problem, but some women may prefer not to articulate their menstrual problems. The objective of this study was to evaluate the usefulness and acceptability of the Pictorial Blood Loss Assessment Chart (PBAC) as a selfscreening tool in evaluation of menstrual blood loss among Asian women in Hong Kong. METHODS: This prospective cohort study recruited 206 women from the general gynaecology ward and out-patient clinic: 118 had self-perceived heavy menstrual bleeding and 88 had self-perceived normal menstrual flow. Participants were asked to fill in the PBAC for one menstrual cycle. RESULTS: Compared with women who had self-perceived normal menstrual flow, women with self-perceived heavy menstrual bleeding had significantly higher total PBAC scores and numbers of flooding episodes, larger clot sizes and numbers, more days of bleeding, and lower haemoglobin levels. Receiver-operating characteristic curve analysis demonstrated good pairwise associations of self-perceived symptoms with PBAC score and haemoglobin level. CONCLUSIONS: The PBAC can be used to differentiate self-perceived heavy and normal menstrual bleeding in Asian women in Hong Kong. It can also serve as an additional indicator of possible heavy menstrual bleeding to alert women of the need to seek early medical attention.


Subject(s)
Menorrhagia , Female , Hong Kong , Humans , Menorrhagia/diagnosis , Prospective Studies
11.
Rev Sci Instrum ; 92(4): 043504, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243446

ABSTRACT

A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold: 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647-662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.

12.
Clin Exp Dermatol ; 46(8): 1504-1510, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34081799

ABSTRACT

BACKGROUND: During the coronavirus disease 2019 (COVID-19) pandemic, various adverse skin reactions to long-term mask wearing have been reported. AIM: To assess the clinical features of mask-induced dermatoses and to recommend prevention and treatment options. METHODS: From April to August 2020, questionnaires including topics such as demographic information, pre-existing skin disorders, reported mask-related symptoms, daily mask-wearing duration and frequency, types of masks used and whether the participant was a healthcare worker, were distributed to patients in 12 hospitals. Dermatologists assessed skin lesions, confirmed diagnosis and recorded treatments. RESULTS: Itchiness was the most frequent symptom, mostly affecting the cheeks. The most common skin disease was new-onset contact dermatitis (33.94%), followed by new-onset acne (16.97%) and worsening of pre-existing acne (16.97%). Daily wearing of masks was significantly (P = 0.02) associated with new-onset contact dermatitis. More than half of patients with pre-existing skin problems experienced disease worsening while wearing masks. Longer duration of wearing (> 6 h/day, P = 0.04) and use of cotton masks (P < 0.001) significantly increased acne flare-up. Healthcare workers had a higher incidence of skin disease. Skin lesions were generally mild and well tolerated with topical treatment. The study had some limitations: the effect of seasonal characteristics and other risk factors were not assessed, and the patients were visiting dermatological clinics and had interest in their skin status, thus, there may have been selection bias. CONCLUSION: Mask-induced/-triggered dermatoses contribute to increase the dermatological burden during the pandemic.


Subject(s)
Dermatitis, Occupational/etiology , Facial Dermatoses/etiology , Masks/adverse effects , Personnel, Hospital , Acne Vulgaris/etiology , Adult , COVID-19/prevention & control , Female , Hospitals, University , Humans , Male , Middle Aged , Pandemics/prevention & control , Pruritus/etiology , Republic of Korea , SARS-CoV-2 , Tertiary Care Centers
13.
Sci Rep ; 11(1): 5286, 2021 Mar 05.
Article in English | MEDLINE | ID: mdl-33674656

ABSTRACT

The Tatun Volcanic Group (TVG) is proximal to the metropolis of Taipei City (population of ca. 7 million) and has long been a major concern due to the potential risks from volcanic activity to the population and critical infrastructure. While the TVG has been previously considered a dormant or extinct volcano, recent evidence suggests a much younger age of the last eruption event (~ 6000 years) and possible existence of a magma reservoir beneath the TVG. However, the location, dimension, and detailed geometry of the magma reservoir and plumbing system remains largely unknown. To examine the TVG volcanic plumbing structure in detail, the local P-wave travel time data and the teleseismic waveform data from a new island-wide Formosa Array Project are combined for a 3D tomographic joint inversion. The new model reveals a magma reservoir with a notable P-wave velocity reduction of 19% (ca. ~ 19% melt fraction) at 8-20 km beneath eastern TVG and with possible northward extension to a shallower depth near where active submarine volcanoes that have been detected. Enhanced tomographic images also reveal sporadic magmatic intrusion/underplating in the lower crust of Husehshan Range and northern Taiwan. These findings suggest an active volcanic plumbing system induced by post-collisional extension associated with the collapse of the orogen.

14.
J Phys Condens Matter ; 33(2): 025402, 2021 Jan 13.
Article in English | MEDLINE | ID: mdl-32906102

ABSTRACT

This paper presents the results of studies of a low-frequency vibration spectrum of PbCo1/3Nb2/3O3 (PCN) relaxor ferroelectric crystal using the Brillouin and Raman light scattering in the temperature range from 80 to 750 K. The analysis of the temperature behaviour of the longitudinal acoustic phonon in Brillouin scattering spectra showed no anomalies in the vicinity of 'diffuse phase transition' (T m = 250 K) in PCN. Polarized Raman light scattering spectra were obtained in PCN over the entire temperature range studied. Analysis of low-frequency optical mode behaviour in PCN during temperature change also revealed no correlations with dielectric permeability anomaly in the vicinity of T m: softening of optical phonon at 43 cm-1 frequency in VV polarization is observed at 170 K. In the same temperature range, there are anomalies (a 'narrow' and weak component) in quasi-elastic light scattering (QELS) obtained in temperature behaviour with VH polarization in Raman spectra in PCN. A 'wide' and intense QELS component, obtained in Raman spectra with VV polarization, shows anomalies in the vicinity of T m. We associate the anomalies of optical phonons and QELS with structure distortions in the formation of phase stratification and the dynamics of polar nano-regions.

15.
Transfus Clin Biol ; 28(1): 44-50, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33227455

ABSTRACT

BACKGROUND: Platelet transfusion is required to treat haemo-oncology or trauma patients. Platelet apheresis (PA) performed with apheresis equipment has increased rapidly in recent years. Leucocyte-reduced platelet apheresis (LRPA) can reduce the risk of platelet refractoriness and febrile nonhemolytic transfusion reactions (FNHTRs) for transfusion. Accordingly, this study aimed to investigate and compare the platelet metabolic and functional responses between PA performed with Haemonetics and LRPA performed with Trima Accel cell separator. METHODS: The qualities of platelets collected through PA and LRPA were evaluated in terms of visual appearance, morphology, platelet-aggregation changes, metabolic activities, and bacterium-screening test during 5-day storage. Statistical analyses included two-sample t-test and generalised estimating equation(GEE) method. RESULTS: During 5-day storage in LRPA, residual leucocytes were all <1.0×106, and the parameters of platelet function were as follows: platelet aggregated to agonists such as adenosine 5'-diphosphate (ADP) and collagen, and the extent of shape change and pO2 showed no statistically significant difference between PA and LRPA. The hypotonic shock reaction (HSR) on days 0, 1, and 3 were significantly higher in LRPA than in PA (71.78±6.92 vs. 64.10±7.42; P=0.002; 71.53±8.98 vs. 62.96±9.84; P=0.007; 68.05±7.28 vs. 57.76±6.80; P<0.0001, respectively). Values of mean platelet volume (MPV) were statistically larger in PA than in LRPA on days 0, 1, and 3. On day 5, the swirling score was higher in LRPA than in PA. The mean lactate levels had no statistically significant difference between PA and LRPA. Moreover, no growth was observed through bacterium-screening test conducted on 40 samples. CONCLUSION: Comparison of LRPA and PA products collected from the Trima Accel and Haemonetics automated blood-collection systems, respectively, revealed that both products possessed good platelet qualities even though additional processes are needed to reduce leucocytes. Furthermore, investigating the outcomes of other apheresis instruments with focus on the safety of donors, products, and recipients is necessary.


Subject(s)
Blood Platelets , Plateletpheresis , Cell Separation , Humans , Leukocytes , Platelet Function Tests
17.
Br J Dermatol ; 183(6): 1065-1072, 2020 12.
Article in English | MEDLINE | ID: mdl-32163589

ABSTRACT

BACKGROUND: Valid patient-reported outcome (PRO) measures are required to evaluate alopecia areata (AA) treatments. OBJECTIVES: To develop a content-valid and clinically meaningful PRO measure to assess AA scalp hair loss with scores comparable with the five-response-level Alopecia Areata Investigator Global Assessment (AA-IGA™). METHODS: A draft PRO measure was developed based on input from 10 clinical experts in AA. The PRO measure was cognitively debriefed, modified and finalized through two rounds of qualitative semistructured interviews with patients with AA who had experienced ≥ 50% scalp hair loss. Data were thematically analysed. RESULTS: Adults (round 1: n = 25; round 2: n = 15) and adolescents aged 15-17 years (round 1: n = 5) in North America participated. All patients named scalp hair loss as a key AA sign or symptom. Patients demonstrated the ability to self-report their current amount of scalp hair using percentages. In round 1 not all patients interpreted the measurement concept consistently; therefore, the PRO was modified to clarify the measurement concept to improve usability. Following modifications, patients in round 2 responded without difficulty to the PRO measure. Patients confirmed that they could use the five-level response scale to rate their scalp hair loss: no missing hair, 0%; limited, 1-20%; moderate, 21-49%; large, 50-94%; nearly all or all, 95-100%. Almost all patients deemed hair regrowth resulting in ≤ 20% scalp hair loss a treatment success. CONCLUSIONS: The Scalp Hair Assessment PRO™ is a content-valid, clinically meaningful assessment of distinct gradations of scalp hair loss for evaluating AA treatment for patients with ≥ 50% hair loss at baseline.


Subject(s)
Alopecia Areata , Adolescent , Adult , Alopecia , Alopecia Areata/diagnosis , Hair , Humans , North America , Patient Reported Outcome Measures , Scalp
18.
Br J Dermatol ; 183(4): 702-709, 2020 10.
Article in English | MEDLINE | ID: mdl-31970750

ABSTRACT

BACKGROUND: Content-valid and clinically meaningful instruments are required to evaluate outcomes of therapeutic interventions in alopecia areata (AA). OBJECTIVES: To develop an Investigator's Global Assessment (IGA) to interpret treatment response in AA treatment studies. METHODS: Qualitative interviews were conducted in the USA with expert dermatologists and with patients with AA who had experienced ≥ 50% scalp-hair loss. Thematic data analysis identified critical outcomes and evaluated the content validity of the new IGA. RESULTS: Expert clinicians (n = 10) judged AA treatment success by the amount of scalp-hair growth (median 80% scalp hair). Adult (n = 25) and adolescent (n = 5) patients participated. Scalp-hair loss was the most bothersome AA sign/symptom for most patients. Perceived treatment success - short of 100% scalp hair - was the presence of ~ 70-90% scalp hair (median 80%). Using additional clinician and patient insights, the Alopecia Areata Investigator Global Assessment (AA-IGA™) was developed. This clinician-reported outcome assessment is an ordinal, static measure comprising five severity categories of scalp-hair loss. Nearly all clinicians and patients in this study agreed that, for patients with ≥ 50% scalp-hair loss, successful treatment would be hair regrowth resulting in ≤ 20% scalp-hair loss. CONCLUSIONS: We recommend using the Severity of Alopecia Tool to assess the extent (0-100%) of scalp-hair loss. The AA-IGA is a robust ordinal measure providing distinct and clinically meaningful gradations of scalp-hair loss that reflects patients' and expert clinicians' perspectives and treatment expectations. What is already known about this topic? The Severity of Alopecia Tool is widely used to assess the extent of scalp-hair loss in patients with alopecia areata. Guidelines define treatment success as a 50% improvement in scalp hair, and clinical trials have used dynamic thresholds of 50% and 90%. However, there is no clinical consensus on these endpoints, and patient perspectives on treatment success are unknown. What does this study add? Through qualitative interviews with 10 expert dermatologists and 30 patients with alopecia areata who had experienced ≥ 50% scalp-hair loss, we developed the Alopecia Areata Investigator Global Assessment (AA-IGA™) to measure five clinically meaningful gradations of alopecia areata scalp-hair loss that reflects patients' and clinicians' perspectives and expectations of treatment success in alopecia areata treatment studies. What are the clinical implications of this work? The AA-IGA is a robust ordinal measure that can inform clinical evaluation of alopecia areata treatment outcomes. The AA-IGA can be used to determine clinically meaningful treatment success for alopecia areata, with success defined by patients and clinicians as reaching ≤ 20% scalp-hair loss. Linked Comment: Blome. Br J Dermatol 2020; 183:609.


Subject(s)
Alopecia Areata , Adolescent , Adult , Alopecia , Alopecia Areata/drug therapy , Hair , Humans , Scalp
19.
Clin Microbiol Infect ; 26(8): 1091.e1-1091.e7, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31901491

ABSTRACT

OBJECTIVES: Chronic pulmonary aspergillosis (CPA) is an emerging global disease with tuberculosis (TB) being the most important risk factor. Epidemiologic data on the seroprevalence of Aspergillus IgG and prevalence of CPA in different areas, especially in country with intermediate burden of TB, are lacking. METHODS: We prospectively recruited healthy volunteers, TB close contacts, active TB patients and participants with old pulmonary TB in Taiwan during 2012-2019. We measured serum Aspergillus fumigatus and niger-specific IgG levels and assessed if the participants were having CPA. RESULTS: A total of 1242 participants (including 200 healthy volunteers, 326 TB close contacts, 524 active TB patients and 192 old TB cases) were recruited. Using 27 mgA/L (milligrams of antigen-specific antibodies per liter) as cut-off level, the seropositive rate of A. fumigatus-specific IgG was 33.0% (66/200), 37.7% (123/326), 26.5% (139/524) and 43.2% (83/192) among the four groups, respectively. In multivariate logistic regression, pulmonary cavitation (OR 1.73; 95% CI 1.07-2.80), female sex (OR 1.49; 95% CI 1.14-1.95), old TB (OR 1.59; 1.05-2.42) were independent risk factors for Aspergillus IgG positivity. One (0.2%) active TB patient and four (2.1%) old TB patients developed CPA. Correlation between A. fumigatus and A. niger-specific IgG was high (Spearman correlation coefficient: 0.942). DISCUSSION: Geographic variation in Aspergillus IgG seroprevalence and CPA prevalence exists. A universal cut-off value for Aspergillus IgG may not exist. In areas and populations in which background Aspergillus IgG level is unknown, Aspergillus IgG may be better used as a test of exclusion for CPA using prespecified cut-off level.


Subject(s)
Aspergillus fumigatus/immunology , Aspergillus niger/immunology , Immunoglobulin G/blood , Pulmonary Aspergillosis/epidemiology , Tuberculosis, Pulmonary/epidemiology , Adult , Aged , Antibodies, Fungal/blood , Case-Control Studies , Female , Humans , Male , Middle Aged , Prevalence , Prospective Studies , Pulmonary Aspergillosis/blood , Sensitivity and Specificity , Seroepidemiologic Studies , Sex Characteristics , Taiwan/epidemiology , Young Adult
20.
J Synchrotron Radiat ; 27(Pt 4): 864-869, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-33565994

ABSTRACT

This paper presents the required structure and function of a ring-FEL as a radiation source for extreme ultraviolet radiation lithography (EUVL). A 100 m-long straight section that conducts an extremely low emittance beam from a fourth-generation storage ring can increase the average power at 13.5 nm wavelength to up to 1 kW without degrading the beam in the rest of the ring. Here, simulation results for a ring-FEL as a EUVL source are described.

SELECTION OF CITATIONS
SEARCH DETAIL
...