Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(14)2022 Jul 11.
Article in English | MEDLINE | ID: mdl-35890859

ABSTRACT

A highly polarizable moisture sensor with multimodal sensing capabilities has great advantages for healthcare applications such as human respiration monitoring. We introduce an ionically polarizable moisture sensor based on NaCl/BaTiO3 composite films fabricated using a facile aerosol deposition (AD) process. The proposed sensing model operates based on an enormous NaCl ionization effect in addition to natural moisture polarization, whereas all previous sensors are based only on the latter. We obtained an optimal sensing performance in a 0.5 µm-thick layer containing NaCl-37.5 wt% by manipulating the sensing layer thickness and weight fraction of NaCl. The NaCl/BaTiO3 sensing layer exhibits outstanding sensitivity over a wide humidity range and a fast response/recovery time of 2/2 s; these results were obtained by performing the one-step AD process at room temperature without using any auxiliary methods. Further, we present a human respiration monitoring system using a sensing device that provides favorable and stable electrical signals under diverse respiratory scenarios.


Subject(s)
Respiratory Rate , Sodium Chloride , Aerosols , Humans , Humidity , Monitoring, Physiologic
2.
Materials (Basel) ; 15(12)2022 Jun 17.
Article in English | MEDLINE | ID: mdl-35744342

ABSTRACT

This work aims to fabricate a large-area ceramic substrate for the application of probe cards. Mullite (M) and cordierite (C), which both have a low thermal expansion coefficient, excellent resistance to thermal shock, and high durability, were selected as starting powders. The mullite-cordierite composites were produced through different composition ratios of starting powders (M:C = 100:0, M:C = 90:10, M:C = 70:30, M:C = 50:50, M:C = 30:70, and M:C = 0:100). The effects of composition ratio and sintering temperature on the density, porosity, thermal expansion coefficient, and flexural strength of the mullite-cordierite composite pellets were investigated. The results showed that the mullite-cordierite composite pellet containing 70 wt% mullite and 30 wt% cordierite sintered at 1350 °C performed exceptionally well. Based on these findings, a large-area mullite-cordierite composite substrate with a diameter of 320 mm for use in semiconductor probe cards was successfully fabricated. Additionally, the changes in sheet resistance and flexural strength were measured to determine the effect of the environmental tests on the large-area substrate such as damp heat and thermal shock. The results indicated that the mullite-cordierite composite substrate was extremely reliable and durable.

3.
Micromachines (Basel) ; 13(6)2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35744556

ABSTRACT

This paper presents a front-end architecture for touch screen panel (TSP) readout in a TSP-integrated, ultrathin flexible display to mitigate severe display noise interference, which is an uncommon mode caused by the large panel load of the TSP in the flexible display. The differential sensing method with multireference TSP channels minimized an imbalance of the phase and amplitude of the coupled-display noise interference. In addition, cascaded time-discrete bandpass sampling was employed to enhance the touch sensitivity in the sensing block. Moreover, a rated front-end block could be reconfigured to a differential or single-ended sensing structure, which reused the prefilter capacitors in the differential sensing for offset cancellation in reference capacitance sensing. To further improve the sensitivity, programmable postfiltering was employed on the reference TSP channels. Subsequently, the proposed front-end was implemented in a 350 nm process, wherein it achieved a SNR of 50.5 dB with a scan rate of 200 Hz and attenuated aggravated display noise interference by more than 6.84 dB as compared to the conventional differential sensing method. The designed chip occupied an area of 4.8 mm2 and consumed 17.6 mW from a 3 V supply.

4.
Micromachines (Basel) ; 12(8)2021 Jul 31.
Article in English | MEDLINE | ID: mdl-34442544

ABSTRACT

This paper presents a mutual capacitance touch readout IC architecture for 120 Hz high-refresh-rate AMOLED displays. In high-refresh-rate AMOLED panels, whole pixels in a horizontal line should be updated without any time-sharing with each other, leading to an amplified display noise on touch screen panel (TSP) electrodes. The proposed system architecture mitigates severe display noise by synchronizing the driving for the TSP and AMOLED pixel circuits. The proposed differential sensing technique, which is based on noise suppression in reference to mutual capacitance channels, minimizes common-mode display noise. In the front-end circuit, intrinsic circuit offset is cancelled by a chopping scheme, which correlates to the phase of the driving signals in the TSP driver and operating clocks of the front-end. Operating at a 120 Hz scan-rate, it reduces display noise by more than 11.6 dB when compared with the conventional single-ended TSP sensing method. With a built-in 130-nm CMOS, a prototype IC occupies an area of 8.02 mm2 while consuming 6.4-mW power from a 3.3 V analog voltage supply.

SELECTION OF CITATIONS
SEARCH DETAIL
...