Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 109
Filter
Add more filters










Publication year range
1.
Nat Commun ; 15(1): 3990, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38734685

ABSTRACT

The path of tokamak fusion and International thermonuclear experimental reactor (ITER) is maintaining high-performance plasma to produce sufficient fusion power. This effort is hindered by the transient energy burst arising from the instabilities at the boundary of plasmas. Conventional 3D magnetic perturbations used to suppress these instabilities often degrade fusion performance and increase the risk of other instabilities. This study presents an innovative 3D field optimization approach that leverages machine learning and real-time adaptability to overcome these challenges. Implemented in the DIII-D and KSTAR tokamaks, this method has consistently achieved reactor-relevant core confinement and the highest fusion performance without triggering damaging bursts. This is enabled by advances in the physics understanding of self-organized transport in the plasma edge and machine learning techniques to optimize the 3D field spectrum. The success of automated, real-time adaptive control of such complex systems paves the way for maximizing fusion efficiency in ITER and beyond while minimizing damage to device components.

2.
Nature ; 609(7926): 269-275, 2022 09.
Article in English | MEDLINE | ID: mdl-36071190

ABSTRACT

Nuclear fusion is one of the most attractive alternatives to carbon-dependent energy sources1. Harnessing energy from nuclear fusion in a large reactor scale, however, still presents many scientific challenges despite the many years of research and steady advances in magnetic confinement approaches. State-of-the-art magnetic fusion devices cannot yet achieve a sustainable fusion performance, which requires a high temperature above 100 million kelvin and sufficient control of instabilities to ensure steady-state operation on the order of tens of seconds2,3. Here we report experiments at the Korea Superconducting Tokamak Advanced Research4 device producing a plasma fusion regime that satisfies most of the above requirements: thanks to abundant fast ions stabilizing the core plasma turbulence, we generate plasmas at a temperature of 100 million kelvin lasting up to 20 seconds without plasma edge instabilities or impurity accumulation. A low plasma density combined with a moderate input power for operation is key to establishing this regime by preserving a high fraction of fast ions. This regime is rarely subject to disruption and can be sustained reliably even without a sophisticated control, and thus represents a promising path towards commercial fusion reactors.

3.
Rev Sci Instrum ; 92(4): 043504, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243446

ABSTRACT

A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold: 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647-662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.

4.
Phys Rev Lett ; 126(12): 125001, 2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33834790

ABSTRACT

Predictive 3D optimization reveals a novel approach to modify a nonaxisymmetric magnetic perturbation to be entirely harmless for tokamaks, by essentially restoring quasisymmetry in perturbed particle orbits as much as possible. Such a quasisymmetric magnetic perturbation (QSMP) has been designed and successfully tested in the KSTAR and DIII-D tokamaks, demonstrating no performance degradation despite the large overall amplitudes of nonaxisymmetric fields and strong response otherwise expected in the tested plasmas. The results indicate that a quasisymmetric optimization is a robust path of error field correction across the resonant and nonresonant field spectrum in a tokamak, leveraging the prevailing concept of quasisymmetry for general 3D plasma confinement systems such as stellarators. The optimization becomes, in fact, a simple eigenvalue problem to the so-called torque response matrices if a perturbed equilibrium is calculated consistent with nonaxisymmetric neoclassical transport.

5.
Phys Rev Lett ; 123(9): 095001, 2019 Aug 30.
Article in English | MEDLINE | ID: mdl-31524439

ABSTRACT

A small nonaxisymmetric (3D) magnetic field can induce nonambipolar transport of the particle species confined in a tokamak and thus a significant change of plasma rotation. This process can be in a favor of instability control in the region where the tokamak plasma is sufficiently collisional and resistive, as observed in the applications of n=1 resonant magnetic perturbations to the KSTAR tokamak. The plasma rotation can be globally accelerated due to radially drifting electrons and constrained to the electron root, if the radial transport is enhanced by an amplified 3D response. This mechanism is verified by a kinetically self-consistent magnetohydrodynamic modeling for both response and transport, which offers the quantitative explanations on the internal n=1 structure detected by electron-cyclotron-emission imaging and the cocurrent plasma spinning observed in the experiments.

6.
Phys Rev Lett ; 119(20): 205001, 2017 Nov 17.
Article in English | MEDLINE | ID: mdl-29219375

ABSTRACT

The propagation dynamics of resonant magnetic perturbation fields in KSTAR H-mode plasmas with injection of small edge perturbations produced by a supersonic molecular beam injection is reported for the first time. The results show that the perturbation field first excites a plasma response on the q=3 magnetic surface and then propagates inward to the q=2 surface with a radially averaged propagation velocity of resonant magnetic perturbations field equal to 32.5 m/ s. As a result, the perturbation field brakes the toroidal rotation on the q=3 surface first causing a momentum transport perturbation that propagates both inward and outward. A higher density fluctuation level is observed. The propagation velocity of the resonant magnetic perturbations field is larger than the radial propagation velocity of the perturbation in the toroidal rotation.

7.
Sci Rep ; 7: 45075, 2017 03 24.
Article in English | MEDLINE | ID: mdl-28338046

ABSTRACT

Solitary perturbations (SPs) localized both poloidally and radially are detected within ~100 µs before the partial collapse of the high pressure gradient boundary region (called pedestal) of magnetized toroidal plasma in the KSTAR tokamak device. The SP develops with a low toroidal mode number (typically unity) in the pedestal ingrained with quasi-stable edge-localized mode (QSM) which commonly appears during the inter-collapse period. The SPs have smaller mode pitch and different (often opposite) rotation velocity compared to the QSMs. Similar solitary perturbations are also frequently observed before the onset of complete pedestal collapse, suggesting a strong connection between the SP generation and the pedestal collapse.

8.
Article in English | MEDLINE | ID: mdl-33898111

ABSTRACT

This paper reports long-term evaluation of a micropackage technology for an implantable MEMS pressure sensor. The all-polymer micropackage survived 160 days when subjected to accelerated lifetime testing at 85 °C in a 1% wt. saline solution. The package shows minimum effect on sensors' sensitivity and nonlinearity, which deviated by less than 5% and 0.3%, respectively. A 6-month in vivo evaluation of 16 MEMS-based pressure sensors demonstrated that the proposed micropackage has good biocompatibility and can protect the MEMS pressure sensor. To the best of our knowledge, these results establish new lifetime records for devices packaged using an all-polymer micropackaging approach.

9.
Rev Sci Instrum ; 85(11): 11D407, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430170

ABSTRACT

In the KSTAR Tokamak, a "Tangential Thomson Scattering" (TTS) diagnostic system has been designed and installed to measure electron density and temperature profiles. In the edge system, TTS has 12 optical fiber bundles to measure the edge profiles with 10-15 mm spatial resolution. These 12 optical fibers and their spatial resolution are not enough to measure the pedestal width with a high accuracy but allow observations of L-H transition or H-L transitions at the edge. For these measurements, the prototype ITER edge Thomson Nd:YAG laser system manufactured by JAEA in Japan is installed. In this paper, the KSTAR TTS system is briefly described and some TTS edge profiles are presented and compared against the KSTAR Charge Exchange Spectroscopy and other diagnostics. The future upgrade plan of the system is also discussed in this paper.

11.
Phys Rev Lett ; 111(9): 095002, 2013 Aug 30.
Article in English | MEDLINE | ID: mdl-24033042

ABSTRACT

One of the important rotational resonances in nonaxisymmetric neoclassical transport has been experimentally validated in the KSTAR tokamak by applying highly nonresonant n=1 magnetic perturbations to rapidly rotating plasmas. These so-called bounce-harmonic resonances are expected to occur in the presence of magnetic braking perturbations when the toroidal rotation is fast enough to resonate with periodic parallel motions of trapped particles. The predicted and observed resonant peak along with the toroidal rotation implies that the toroidal rotation in tokamaks can be controlled naturally in favorable conditions to stability, using nonaxisymmetric magnetic perturbations.

12.
Phys Rev Lett ; 109(19): 195003, 2012 Nov 09.
Article in English | MEDLINE | ID: mdl-23215391

ABSTRACT

It is observed that the magnitude of the toroidal rotation speed is reduced by the central electron cyclotron resonance heating (ECRH) regardless of the direction of the toroidal rotation. The magnetohydrodynamics activities generally appear with the rotation change due to ECRH. It is shown that the internal kink mode is induced by the central ECRH and breaks the toroidal symmetry. When the magnetohydrodynamics activities are present, the toroidal plasma viscosity is not negligible. The observed effects of ECRH on the toroidal plasma rotation are explained by the neoclassical toroidal viscosity in this Letter. It is found that the neoclassical toroidal viscosity torque caused by the internal kink mode damps the toroidal rotation.

13.
Phys Rev Lett ; 109(3): 035004, 2012 Jul 20.
Article in English | MEDLINE | ID: mdl-22861864

ABSTRACT

Edge localized modes (ELMs) in high-confinement mode plasmas were completely suppressed in KSTAR by applying n=1 nonaxisymmetric magnetic perturbations. Initially, the ELMs were intensified with a reduction of frequency, but completely suppressed later. The electron density had an initial 10% decrease followed by a gradual increase as ELMs were suppressed. Interesting phenomena such as a saturated evolution of edge T(e) and broadband changes of magnetic fluctuations were observed, suggesting the change of edge transport by the applied magnetic perturbations.

14.
Article in English | MEDLINE | ID: mdl-23366225

ABSTRACT

Poly-dimethylsiloxane (PDMS) is an attractive material for packaging implantable biomedical microdevices owing to its biocompatibility, ease in application, and bio-friendly mechanical properties. Unfortunately, devices encapsulated solely by PDMS lack the longevity for use in chronic implant applications due to defect-related moisture penetration through the packaging layer caused by conventional deposition processes such as spin coating. This paper describes an effort to improve the performance of PDMS as a packaging material by constructing the encapsulant from multiple, thin roller casted layers of PDMS as a part of a polymeric multi-material package.


Subject(s)
Dimethylpolysiloxanes/chemistry , Electronics, Medical , Micro-Electrical-Mechanical Systems , Product Packaging , Electricity , Humans , Surface Properties , Telemetry , Time Factors
15.
Rev Sci Instrum ; 81(6): 063502, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20590236

ABSTRACT

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H(alpha), visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

16.
Rev Sci Instrum ; 80(10): 103503, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19895060

ABSTRACT

The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.

17.
IEEE Trans Biomed Circuits Syst ; 3(5): 277-85, 2009 Oct.
Article in English | MEDLINE | ID: mdl-23853266

ABSTRACT

There is a need for high-quality implantable microphones for existing semiimplantable middle-ear hearing systems and cochlear prosthesis to make them totally implantable, thus overcoming discomfort, inconvenience, and social stigma. This paper summarizes and compares the results of an in-vitro study on three design approaches and the feasibility of using microelectromechanical system acoustic sensors as implantable microphones to convert the umbo vibration directly into a high-quality sound signal. The requirements of sensors were selected including the ability to withstand large body shocks or sudden changes of air pressure. Umbo vibration characteristics were extracted from literature and laboratory measurement data. A piezoelectric vibration source was built and calibrated to simulate the umbo vibration. Two laboratory models of the acoustic sensor were studied. The model-A device, using electrets-microphone as the sensor, was designed and tested in the laboratory and on temporal bones. The results verify that the laboratory measurement is consistent with the temporal bone characterization and achieves a near flat frequency response with a minimum detectable signal of a 65-dB sound-pressure-level (SPL) at 1 kHz. The model-B sensor was then designed to increase the sensitivity and provide an easy mounting on umbo. The model-B device can detect 40-dB SPL sound in the 1-2 kHz region, with 100-Hz channel bandwidth. The results of model-A and model-B displacement sensors and the acceleration sensor are summarized and compared. A preliminary design of the implantable displacement sensor for totally implantable hearing-aid systems is also presented.

18.
Br J Pharmacol ; 149(6): 703-11, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17016497

ABSTRACT

BACKGROUND AND PURPOSE: Experiments were designed to determine the mechanism of the relaxation induced by tamoxifen in porcine coronary arteries at the tissue, cellular and molecular levels. EXPERIMENTAL APPROACH: Porcine left circumflex coronary arteries were isolated and isometric tension was measured. [Ca2+]i in native endothelial cells of intact arteries was determined by a calcium fluorescence imaging technique and eNOS ser1177 phosphorylation was assayed by Western blotting. KEY RESULTS: Tamoxifen induced an endothelium-dependent relaxation that was antagonized by ICI 182,780 and abolished by NG-nitro-L-arginine methyl ester (L-NAME) or 1H-[1,2,4]oxadizolo[4,3-a]quinoxalin-1-one (ODQ). L-Arginine reversed the effect of L-NAME while indomethacin was without effect. Tamoxifen-induced relaxation was attenuated by charybdotoxin (CTX) plus apamin, ouabain or by incubation in a K+ -free solution. Moreover, tamoxifen triggered extracellular Ca2+ -dependent increases in endothelial [Ca2+]i and this effect was abolished by ICI 182,780. Endothelium-independent relaxation to sodium nitroprusside was also inhibited by ouabain or in a K+ -free solution. Furthermore, tamoxifen increased endothelial nitric oxide synthase (eNOS) phosphorylation at Ser-1177 and ICI 182,780 prevented this effect. CONCLUSIONS AND IMPLICATIONS: The present results suggest that tamoxifen mainly induces endothelium-dependent relaxation and that endothelial nitric oxide (NO) is the primary mediator of this effect. NO-dependent responses may result from elevated [Ca2+]i in endothelial cells; an effect abolished by ICI 182,780. NO activates Na+/K+ -ATPase in vascular smooth muscle, leading to relaxation. These results suggest that tamoxifen is able to modulate eNOS phosphorylation directly.


Subject(s)
Coronary Vessels/drug effects , Nitric Oxide/physiology , Ouabain/pharmacology , Tamoxifen/pharmacology , Animals , Calcium/metabolism , Coronary Vessels/enzymology , Coronary Vessels/physiology , Cycloheximide/pharmacology , Dactinomycin/pharmacology , Estradiol/pharmacology , Free Radical Scavengers/pharmacology , Nitric Oxide Synthase Type III/metabolism , Nitroprusside/pharmacology , Phosphorylation , Potassium Channel Blockers/pharmacology , Swine
19.
Br J Pharmacol ; 149(1): 43-55, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16880767

ABSTRACT

BACKGROUND AND PURPOSE: Absorptive epithelia express apical receptors that allow nucleotides to inhibit Na(+) transport but ATP unexpectedly stimulated this process in an absorptive cell line derived from human bronchiolar epithelium (H441 cells) whilst UTP consistently caused inhibition. We have therefore examined the pharmacological basis of this anomalous effect of ATP. EXPERIMENTAL APPROACH: H441 cells were grown on membranes and the short circuit current (I(SC)) measured in Ussing chambers. In some experiments, [Ca(2+)](i) was measured fluorimetrically using Fura -2. mRNAs for adenosine receptors were determined by the polymerase chain reaction (PCR). KEY RESULTS: Cross desensitization experiments showed that the inhibitory response to UTP was abolished by prior exposure to ATP whilst the stimulatory response to ATP persisted in UTP-pre-stimulated cells. Apical adenosine evoked an increase in I(SC) and this response resembled the stimulatory component of the response to ATP, and could be mimicked by adenosine receptor agonists. Pre-stimulation with adenosine abolished the stimulatory component of the response to ATP. mRNA encoding A(1), A(2A) and A(2B) receptor subtypes, but not the A(3) subtype, was detected in H441 cells and adenosine receptor antagonists could abolish the ATP-evoked stimulation of Na(+) absorption. CONCLUSIONS AND IMPLICATIONS: The ATP-induced stimulation of Na(+) absorption seems to be mediated via A(2A/B) receptors activated by adenosine produced from the extracellular hydrolysis of ATP. The present data thus provide the first description of adenosine-evoked Na(+) transport in airway epithelial cells and reveal a previously undocumented aspect of the control of this physiologically important ion transport process.


Subject(s)
Adenosine/pharmacology , Respiratory Mucosa/metabolism , Sodium/metabolism , Adenosine Triphosphate/analogs & derivatives , Adenosine Triphosphate/pharmacology , Biological Transport, Active/drug effects , Calcium/metabolism , Cell Line , Data Interpretation, Statistical , Fluorescent Dyes , Fura-2 , Humans , Purinergic P1 Receptor Antagonists , RNA/biosynthesis , RNA/genetics , Receptors, Purinergic P2/drug effects , Receptors, Purinergic P2Y2 , Respiratory Mucosa/cytology , Respiratory Mucosa/drug effects , Reverse Transcriptase Polymerase Chain Reaction
20.
Plant Dis ; 90(7): 858-861, 2006 Jul.
Article in English | MEDLINE | ID: mdl-30781021

ABSTRACT

More than 21% of the Chinese herbs tested contained substances in their aqueous extracts inhibitory to conidial germination of the powdery mildew fungus Oidium murrayae. Extracts from Chinese rhubarb and Japanese knotweed were very effective in controlling powdery mildew on cucumber, pumpkin, and eggplant. The inhibitory substance in Chinese rhubarb was soluble in polar solvents and less soluble in nonpolar solvents. The inhibitor in the aqueous extract was not dialyzable in the membrane tubing with molecular weight cut-off of 14,000, but was exchangeable by anion but not cation exchange resins, indicating that the inhibitor has a molecular weight larger than 14,000 and negative charge on its molecule.

SELECTION OF CITATIONS
SEARCH DETAIL
...